HomeMy WebLinkAboutEngineering Field Withdrawal TestDederal 4 ngineering gesting, Inc Dated: February 20, 2020 Paul Bange Roofing, Inc. 7000 SW 21stPlace Davie, FL 33317 Attn: Omar Velazquez RE: Field Withdrawal Resistance Test Publix #855 7576 South US Bay #22 Port St. Lucie FL, 34952 Dear: Sirs: Phone:954-784-2941 E-Fax: 954.784.7875 admin@fed-eng.com www.fedmeng.com Job Order# 20R121 Pursuant to your request, Federal Engineering &Testing, Inc. (FE&T) has performed a field withdrawal resistance test in compliance with Testing Application Standard TAS-105 and the Florida Building Code High Velocity Hurricane Zone at the above referenced site. The purpose of our test was to determine the uplift capacity of the mechanical fasteners at the above referenced project. FE&T is a Miami Dade Certified Testing Laboratory (Certification #18-1105.02). On 02/19/2020 our field representative visited the referenced site and conducted thirty-one (31) field withdrawal resistance tests on the OMG #12 screw fasteners into the metal roof deck. All tests were found in compliance with the Florida Building Code and TAS405. See attached copies of TAS-105 forms with test results. The test results presented reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof conditions are continuously changing one to exposure to the elements. All tests were conducted according to the Florida Building Code Test Protocol TAS405 using a calibrated Comten Industries Fastener Tester Model No.DFG 2W2000 (see attached calibration). FE&T is an independent third party providing un-biased testing information and results. FE&T is not affiliated with our client nor do we have any fmancial interest in the project or determination of the test results. Federal Engineering &Testing, Inc., appreciates the opportunity to be of service to you at this phase of your project. If you have am/; questions or comments, please give us a call. It has been a pleasure working with you and look forward to doing so in the near future. Sincerely, Keith LeBlanc, P.E. Z Lo yc Federal Engineering and Testing, nc. Florida Reg. Number 59394 Certificate of Authorization # 5471 Miami -Dade County Certification # 184105,02 Attachments include the following: Field Withdrawal Resistance Test Results Field Sketch Comten Calibration Florida Building Code Test Protocol TAS405 Building Code Compliance Office Testing Application Standard TAS 105-11 Field Withdrawal Resistance Test Results General Information: Job Name: Publix #855 Job Address: 7576 South USl Bay #22 Port St. Lucie FL, 34952 Contact Individual at jobsite (if any) Omar Velazquez Testing Agency /Equipment Information: Oederal QOngineering ®Oesting, Inc. Note: The undersigned acknowledges that all testing has been conducted and results have been reported in compliance with Florida Building Code Test Protocol TAS-105 Testing Agency Name: Federal Engineering &Testing lnc. Company Address: 3370 NE Sth Avenue, Oakland Park, FL 33334 Company Telephone: (954) 784-2941 Company Fax: (954) 784-7875 Representative Name: Mr. Keith LeBlanc P.E. Representative Title: Professional Engineer Signature: l /ez Z ���_ Testing Apparatus: Comten Industries Fastener Tester Model DFG2W2000 Field Withdrawal Resistance Recording Sheet Component to be secured: ❑ Insulation ❑ Membrane ❑ Anchor or Basesheet ❑ Woodblocking ❑ Metal Profiles 0 Resistance Verification Only Area Number I Q ederal Q ngineering 8OQ esting, Inc. (Refer to deck dimensions on Page No. 2) Fastener Type: #12 Screw Fastener Manufacturer: OMG Predrilled: Yes ❑ No ❑ If Yes, Drill Bit Size: N/A "diameter Hole Depth: N/A See Seotion 8 [o determine number of tests (If drill is high tolerance include range in 1/1000"tolerance) Sample Ix Plan Identifier Initial Failure Load (Ibf) Roof Area 1 615 C 2 547 C 3 519 C 4 634 C 5 921 C 6 613 C 7 584 C 8 615 P 9 619 P 10 563 P 11 629 P 12 617 P 13 612 P 14 625 P 15 546 P 16 522 P 17 577 F 18 608 F 19 669 F 20 554 F 21 672 F 22 677 F 23 572 F 24 609 F 25 673 F Fastener Installation Information: Sample P. Plan Identifier Initial Failure Load (Ibf) Roof Area 26 605 F 27 710 F 28 633 F 29 618 F 30 505 F 31 569 F 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Is the fastener a self driller? ❑� Yes ❑ No If yes, list the type of tool used for fastener installation: Cordless Drill Speed of tool: Variable rpm's Number of tests conducted: n= 30 * See Section 8 of Test Protocol TAS 105 * Note the locations of all tests on "Building Information" Detail 4I, attached) Mean Failure Load F= Sample Standard Deviation Sf= Minimum Characteristic Resistance Force F'= 634.40 lbf 79.29 lbf 616.15 lbf Oederal OQ ngineering ®Oesting, Inc. Notes: 1) Use of the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined in RAS 117, shall utilize the minimum characteristic resistance force (F), determined in compliance with Section 9 of TAS I05. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105, 2) A safety factor of 2 to I shall be applied to all results of laboratory testing. 3) The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Tes[ Recording Sheets. Roof Area 1 (If no parapet wall exists insert "N/A") N/A y 18 Feet Ground Level Building Information - Detail # 1 ,l Cardinal, ' ' Cardinal Scale Manufacturing Co. Products & Solutions for, the Weighing Industry Miami Branch Office • Sales, Service, Rentals OWNER OF ITEM: FEDERAL ENGIIJEERING REPORT Ntl.: 34074 SCALE TYPE: PUSH/PULL TESTER CALIBRATION DATE: 12/04/18 MANUFACTURER: COMTEN /ASHCROFT RECALIBRATION DUE: MARCH 2O20 MODEL NUMBER: DFG2W2000 TECHNICIAN: SCOTT SERIAL NUMBER: 21210010 / WT #2 _ CAPACITY: 21000 LB PROCEDURE USED: TEST WEIGHT DIVISIONS: 1 LB THIS DOCUMENT CERTIFIES THAT THE ABOVE INSTRUMENT HAS BEEN TESTED AND FOUND'I"O BE WITHIN 5 % OF THE FIRST 500 LB. OF A TEST LOAD AND WITHIN 10 % OF A TEST LOAD BETWEEN 501 LB AND 2,000 LB THE STANDARDS USED ARE NLSO TRACEABLE "f0 THE NATIONHL INSTITUTE OF STANDARDS AND TECHNOLOOY (NIST). STANDARDS CALIBRATION DATE: FLORIDA STATE CERTIFICATION NO.: 11/15/2U19 137 CARDINAL • DETECTO Miami Branch Office: 3215 NW 10th Terrace, Suite 203 Oakland Park, FL 33309 .�A Phone: (954) 563-4120 Fax: (954) 563-9920 miaml@cardet.com www.CardlnalScale.com �Vv