HomeMy WebLinkAboutHribar (SS) Sheet 07 dated 24 Mar 20 (7)FLAT CONCRETE TILE ROOF ON PEEL 4 STICK MEMBRANE ON 5/8" CDX, PLYWOOD ON PRE-ENG'D WOOD TRUSSES 6 2 4" 0/C COPPER DRIP EDGE ON I" X 3" P.T. WOOD DRIP ON 2" X 8" SMOOTH SAWN GEGAR FASCIA ON 2" X 4" SUB -FASCIA SIMPSON HETA20 TYPICAL EACH TRUSS END 6" X 6" P.T. EAVE BRACKETS W/ 3/4" BEVELED END° V v G�nrl\l..i 3 6" HT, E.S.P. BRONZE ALUMINUM RAILING FORMED 4 POURED CONCRETE SLAB SEE DETAIL SHEET # 10 COACH LIGHT FIXTURE VERIFY SELECTION BY OWNER INSTALLED BY CONTRACTOR SMOOTH STUCCO WATER -MARK BAND 3 6" SQUARE X 14"D THICKENED - COLUMN FTG. W/ #5 BARS aQ 8" 0/C EACH WAY Z(`3 2,-b OVERHANG FLASH 4 COUNTER - FLASH 0 ROOF ! WALL JUNCTION 12 5 n 0 01 1" X 6" T 4 G STAINED WOOD CEILING 2 4" W X i b"D FORMED r1a POURED CONCRETE BEAM W/ 6 - #5 BARS 4 #3 HOOPS aQ 16" O/C 5/8" SMOOTH STUCCO SLOPE E NON-SKID TRAVERTINE FLOOR MATERIAL 4" STEP DOWN I" X 6" T 4 G STAINED WOOD CEILING 5/8" SMOOTH STUCCO SLOPE NON-SKID TRAVERTINE FLOOR MATERIAL 4" STEP DOWN o- -o- o o- a " I" ICYNENE FOAM INSUL, R-20 5/8" DRYWALL CEILING 8" X 14" CONC. BEAM W/ II 4 - #5 BARS CONTINUOUS 1/2" DRYWALL WALLS ON I" X 2" P.T. FURRING ON 3/4" RIGID FOAM FOIL FACED INSULATION R - 5.4 WOOD BASE 3/4" T.G. PLYWOOD GLUE 4 NAIL ON 3 1/2" WIDE X 2 4"DEEP FLOOR TRUSSES 0 1132" O/C 5/8" DRYWALL CEILING 8" X 14" CONIC, BEAM W/ 4 - #5 BARS CONTINUOUS 1/2" DRYWALL WALLS ON I" X 2" P.T. FURRING ON 3/4" RIGID FOAM FOIL FACED INSULATION R - 5.4 8" X 1160" C.M U. W/ POURED BLOCK CELLS aQ 4'-0" MAX. SPACING 4 aQ EACH SIDE OF DOORS OR WINDOWS 4 ALL CORNERS WOOD BASE 3/4" TG, PLYWOOD GLUE 4 NAIL ON 3 1/2" WIDE X 2 4"DEEP FLOOR TRUSSES Q 192" 0/C 5/8" DRYWALL CEILING 2" X 4" P.T. NAILER W/ 1/4" X 4" TAP CON aQ 32" O/C 1/2" DRYWALL WALLS ON I" X 2" P.T. FURRING ON 3/4" RIGID FOAM FOIL FACED INSULATION R - 5.4 4" CONCRETE SLAB W/ 6 X 6 10/10 WWF, ON 6 MIL VAPOR BARRIER ON TERMOTE TREATED SOIL 3000 P.S,I. CONCRETE 2500 PS F. SOIL BEARINr 0 ' 0 0 2 4" X 14" THICKENED EDGE W/ 3 45 BARS CONTINUOUS 3 it -411 THR.FLR 22'-0" THR. FLR. ' 0 r 20'-O"" SEC. FLR, G� 0 n 10' - BEG, JL 34 V.TIR. i i WASHER J L3" V.T.R. 1 1TUB 2" 1 I 1 1 I SHR, I LAY. 2" , - i' � .L TOIL 3" 3" 2" - LAY. z" OWNERS BATH 3"LAY.i I 2'1SHR .I , LAV. ILAV. I BATH # TWO 43" " I i SHR. t TOIL{ i I IWASHER I SINK ' 2" LAUNDRY LOOP VENT 9 KIT. ISL q SINK 2" " KITCHEN TOIL 3;, v 2" 3" BATH # THREE _ THIRD FLOOR SECOND FLOOR SINK 4" 'I TOIL. LAV, Y' 3" PDR, RM. SECOND FLOOR FIRST FLOOR 4" I LAV. 2" TOIL tf 3" 4" CA. CABANA BATH PI UMBING WASTE RISER DIAGRAM NO SCALE 4" SANITARY WASTE LINE TO COMMUNITY SEWER SYSTEM IN ROAD RIGHT-OF-WAY BEGIN 9 RAIL WALL CENTERLINE W/ IST 2" X 6" STUD 4 WORK OUT FROM THERE b" O.C. BOTH DIRECTIONS, STUDS TO BE IN-LINE BOTTOM TO TOP OF WALL/ USE PLUMB BOB OR LASER FOR ALIGNMENT 3/4" PLYWOOD DIRECTLY ON WOOD STUDS FROM BOTTOM TO TOP OF RAIL WALL ONLY/ NAILED OR SCREWED EVERY b" TO 8" O.G. 3/4" PLYWOOD FULL WIDTH OF RAIL WALL OPTIONAL ELEVATOR RAIL WALL FRAMING DETAIL 1/2" = 110" VERIFY ALL ELEVATOR INSTALLATION DETAILS 4 CONDITIONS W/ SOUTHEAST ELEVATOR, INC. z 18150 24 MAR 20 OF NINETEEN RM SW