FL -a F121580-11I
Application Type Revision
Code Version 2012
Application Status Approved
Comments
Archived
product Manufacturer
Florida Metal Products Inc.
Address/Phone/Email
6940 Stuart Ave
Jacksonville, FL 32254
(909) 283-8400
clark@fiamm.com
Authorized Signature
FLPA Services
fipaserv@yahoo.com
Technical Representative
Garkjones
Address/Phone/Email
p e box 6310
jaclo onvills, FL 32236
(904) 783-8400
clarkllaflimp..cem
Quality Assurance Representative
clark Jones
Address/Phone/Email
p o box 6310
Jacksonville, FL 32236
(904) 283-8400
clark0flamco.com
Category
Roofing
Subcategory
Roofing Accessories that are an Integral Pert of the Roofing System
Compliance Method
Evaluation Report from a Florida Registered Architect or a licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Recelved
Florida Engineer or AnIhibect Name who developed the James L. Bucker, P.E.@ CBUCK Engineering
Evaluation Report
Florida license
PE-31242
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration pate
12/31/2020
Validated By
Michael John Rieme6 P.E.
Validation Checklist - Hanicopy Received
Certificate of Independence
F21569 RI CO[ ertiFl t Of1d 2pdf
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1208.2
Product Approval Method Method 2Option B
Date Submitted 10/05/2017
Date Validated 10/25/2017
Date Pending FBC Approval 10/27/2017
Data Approved 12/12/2017
Summary W Produats
FL #
Model, Number or Name
Description
21580.1
1 - P1AMCO "Off- idge Roof Vent'
Low profile, off -ridge roof vent for pitched mote falodamed from
26 gauge, G-90 primed, galvanized steel
Limits of Use
Approved for use In WHIZ: No
Approved for use outside HVHZ: Yes
Impact Resistant. No
Installation InstruNons
1 L 1580 R1 II 1 ONRIdgeRmoNent FVALREPORT df
Verified By: lames L. Buckner, P.E. @ CBUCK Engineering P.E.
#31242
Dealgn Pressure: +N/A/-46
Other: Refer to Evaluation Report for Limitations and
Conditions of Use. Refer to manufacturer's installation
instructions as a supplemental guide for attachment
Created by Independent Third Party: Yes
Evaluation Reports
'd1580 R1 AE EVAL0.EPORT pgf
Crossed by Independent Third Party: Yes
21580.2
2 - FLAMCO "Gooseneck Roof Vent'
Gooseneck style roof vents for sloped shingle or the roofs
fabricated from 26 gauge, G-90 primed, galvanized steel
Limits of Use
Itutallation InatruNons
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
FU1580 RI II 2 GoozeneckRn N t ve o[pORTp I�f
Verified By: lames L. Buckner, P.E. @ CBUCK Engineering P.E.
a31242
Design Pressure: +N/A/-90
Other: Refer to Evaluation Report for Limitations and
Condltlonz of Use. Refer to manufacturers installation
Instructions as a supplemental guitle for attachment.
Created by Intlependent Third Party: Yes
Evaluation Reports
FUIS80 R1 AE 2 Goos,mxkRom'ant\ PORTgdf
Created by Independent Third Party: Yes
21M0.3
3 - FLAMCO -RV 10 Ridge VeM"
Aluminum Ridge Vents for pitched roofs fabricated from 0.025-
Aluminum
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: N/A
Other: Refer to Evaluation Report for Limitations and
Conditions of Use. Refer to manufacturer's Installation
EL21580 Rf It 3 RVID Rltlg9Vent EVALRFPORT di
verified By: lames L. Buckner, P.E. @ CBUCK Engineering P.E.
#31242
Created by Independent Third Party: Yes
Evaluation Reports
F 31580 Rf AF 3 RV10 RdgeVent EVALREPORTodf
instructions as a supplemental guide for attachment.
Created by Indepentlent Third Party: Yes
Bert
SPpooD us::2601B�lf Stinenoatl Te aFL323"Pbene'650Y82-182q
l a State of PoHda Is an WEED employe[ (pp nn WR3013 SYete ni Fatl a :: Pirve &aaasdaUs .Sratemm ..
-o da laws small a44aa—are 11E1-11--. If yov Oo nIX mrtyour a -mall address released In moons. to a ou Elk-,vonn nonesL do nM xoM eY
avallame an me puoac Io oca—'re
Ir yu
Product Approval AosepW:
mc-J®Ftl®
Credit Card
Safe
CBUCK Engineering
Speclalti,l Structural Engineering
Evaluation Report
FLAMCO "RV10"
Ridge Vent
CBUCK, Inc. Certificate of Authorization #8064
Manufacturer:
Florida Metal Products, Inc.
6940 Stuart Avenue
Jacksonville, FL 32254
for
Florida Product Approval
# FL 21580.3
Florida Building Code 6th Edition (2017)
Method: 2 - B
Category: Roofing
Sub - Category: Roofing Accessories that are an Integral
Part of the Roofing System
Product Name: "Ridge Vent"
Product Description: Roof Vent
Attached To: Wood Deck
Prepared by:
James L. Buckner, P.E., SECB
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No. 17-185-RV10-ER
Date: 9/18/17
Contents:
Evaluation Report Pages 1-9
Facsimile of digital copy signed by
lames L Buckner, P.E.
Electronically signed and sealed documents' shall
comply with the provisions of FAC Rule 61G15-23
� Es it
*' No 31242 *'
* wL
:0 -
ice.(,'. STATE OF .u22"C
F<Oelol,,. G\\�
%,, ONl����
2017.10.25 12.01:30-01
CBUCK, Inc. dba CBUCK Engineering
Phone: (561) 491-9927 Email: cbuck@cbuckinc.net Website: www.cbuckirl
Business: 1374 Community Dr., Jupiter, FL 33458 - Corp/Mailing: 2637 C Atlantic Blvd, p34069, Pompano Beach, Fk 33062
CBUCK Engineering
SpreclalFtj Structural ErKVrieerlrtq
1.0 Manufacturer: Florida Metal Products, Inc. dba FLAMCO
6940 Stuart Avenue
Jacksonville, Florida 32254
(800)634-9400
htto://flamw.com
2.0 Manufacturing Plant: Jacksonville, Florida
3.0 Product:
3.1 Product Name: "RV10"
3.2 Product Description: Ridge Vent
4.0 Evaluation Scope:
4.1 Compliance with the following
Florida Building Code 6th Edition (2017)
4.2 Evaluation Method:
Florida Product Approval Rule 61G20-3.005 (2) (b)
FL FL 21580.3 R1
Date: 9/18/17
Report No.: 17-185-RV30-ER
Page 2 of 5
CBUCK, Inc. Certificate ofAuthorizution k8064
4.3 Evaluation Classification:
Category: Roofing
Sub Category: Roofing Accessories that are an Integral part of the Roofing System
4.4 Properties Evaluated
Structural (Wind Resistance) Properties
4.5 Limits of Evaluation:
This product assembly evaluation is limited to compliance with section 4.1 to section 4.4 of
this report.
5.0 Evaluated Uses:
FLAMCO "II ridge vent is used as a roof ventilator.
6.0 Product Assembly Description:
6.1 General:
The FLAMCO "RV10" are ridge vents for pitched roofs fabricated from nominal 0.025" coated
aluminum mechanically attached to Plywood Deck.
7.0 General Assembly as Evaluated:
Refer to section 15.0 of this report for product assembly components/materials & standards.
8.0 Support System:
(Design of support system is outside the scope of this evaluation.)
8.1 Type: Wood Deck
8.2 Description: 15/32" (min.) or greater plywood, or
Wood plank deck (based on minimum density/specific gravity of 0.42)
9.0 Slope:
Minimum slope shall be 2:12. (and in compliance with FBC Chapter 15 based on the type of roof covering,
applicable code sections and in accordance with manufacturers recommendations.)
FL 8:
CBUCK Engineering Date:
Report No.:
Page
SpeclalFy Structural EnQlrteprinQ
FL 21580.3 R1
9/18/17
17-185-RV10-ER
3 of 5
CBUCK, Ina Certificate cfAuthonzation #8064
10.0 Performance:
The following test protocols were performed to demonstrate compliance with the intent of the code:
10.1 TAS-100(A)-95 - Wind and Wind Driven Rain Resistance and/or Increased Windspeed Resistance of
Soffit Ventilation Strip and Continuous or Intermittent Ventilation System Installed at the Ridge Area.
MOCode Compliance:
11.1 The product assembly described herein has demonstrated compliance with the Florida Building Code
6th Edition (2017) Section 1708.2.
12.0 Limitations and Conditions of Use:
12.1 Design of support system is outside the scope of this report. Support shall be structural framing
members complying with the code and shall be designed by others.
12.2 Scope of "Limitations and Conditions of Use" for this evaluation:
This evaluation report for "State Approval" contains technical documentation, specifications and
installation method(s) which include "Limitations and Conditions of Use" throughout the report in
accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the
authority to approve products under "State Approval".
12.3 Option for application outside "Limitations and Conditions of Use"
Rule 61G20-3.005(l)(e) allows engineering analysis for "project specific approval by the local
authorities having jurisdiction in accordance with the alternate methods and materials authorized in
the Code". Any modification of the product as evaluated in this report and approved by the Florida
Building Commission is outside the scope of this evaluation and will be the responsibility of others.
12.4This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with
Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building
Commission approval for the listed code related criteria. This report by James Buckner, P.E. and
CBUCK Engineering is not a design certification of code compliance construction submittal
documentation, per FBC section 107, for any individual structure, site specific or permit design.
12.5 This product has been evaluated to a maximum height of 33 feet.
12.6 Referto applicable building code forventilation requirements.
12.7 All metal components and fasteners shall be corrosion resistant in accordance with FBC.
12.8 Fire Classification is outside the scope of Rule 61G20-3, and Is therefore not included in this
evaluation.
12.9 This report does not evaluate the use of this product assembly as described in this report for use in
the High Velocity Hurricane Zone code section. (Dade & Broward Counties)
13.OQuality Assurance:
The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code
and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved
quality assurance entity through Keystone Certifications, Inc., (FBC Organization #QUA ID:1824).
FL #: FL 21580.3 R1
CBUCK
Report No.: 17-185-RV30-ER
Engineering Date: 17-1857
Page 4 of 5
SppaalhJ S}'fUCfLXdI &nQIrlpPFhlQ [BUCK Inc. Certocate ojauthorkation#8064
14.0 System/Components
14.1 "RV 30 Ridge Vent"
14.1.1 Material:
Aluminum
14.1.2 Thickness:
0.025" (nominal, with coating)
14.1.3 Corrosion Resistance:
In compliance with FBC Section 1507.4.3;
ASTM B209
14.1.4 Overall Product Dimensions (nominal):
14.1.4.1 Length(s):
10 ft. (max.)
14.1.4.2 Width:
8-3/8 in. (±Y" nominal)
14.1.4.3 Height:
2-1/4 in. (±Y." nominal)
14.2 Fastener:
14.2.1 Base Fastener:
Attaches Roof Vent to Deck
14.2.1.1 Type:
Smooth or Ring Shank Roofing Nails
14.2.1.2 Size:
6d x 2" (Long)
14.2.1.3 Material:
Aluminum
14.2.1.4 Corrosion Resistance: Per FBC Section 1506.5
14.2.1.5 Standard:
Per ASTM F 1667
14.3 Roof Adhesive:
14.3.1 Type:
Standard Heavy bodied Flashing Cement
14.3.2 Description:
Asbestos -free asphalt based roof cement
14.3.3 Application Size:
1/4" thick (min.)
14.3.4 Standard:
Per ASTM D 4586 Type I
15.0 Installation Method:
(Refer to installation method at the end of this evaluation report.)
Prepare deck opening by trimming any shingles or tiles & existing nails that may interfere with ridge vent
installation. Apply roof cement to the underside, back and side flanges of the ridge vent. Cement should
be a 1/4" thick and extend 2" onto roof underlayment. (Install cement in compliance with manufacturers
installation guidelines.) Position vent base flange beneath loosened shingles and align with deck opening.
Attach the unit side flanges to deck with fasteners per Section 14.2 spaced 6" o.c. and 1-1/2"- 2" from
each end. Apply Roofing Cement to exposed fastener heads. Minimum fastener penetration thru bottom
of support, 3/16".
The FLAMCO "RV 10 Ridge Vent" shall be installed in compliance with the installation method listed in
this report and applicable code sections of FBC 6th Edition (2017). The installation method described
herein is in accordance with the scope of this evaluation report. Refer to manufacturers installation
instructions as a supplemental guide for attachment.
16.0 Evaluation Reference Data:
16.1 TAS 100 (A) Wind Driven Rain Test
By Fenestration Testing Laboratory, Inc. (FTL) (FBC Organization #TST ID: 1657)
Project #16-6647, Lab #9124, Dated: 11/09/16
16.2 Quality Assurance
By Keystone Certifications, Inc. (FBC Organization #: QUA 1824)
Licensee #440
16.3 Engineering Analysis
By lames L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
16.4 Certification of Independence
By lames L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
FL #:
FL 21580.3 RI
Date:
CSUCK Engineering Rrt No
9/18/17
17-
epo
55-RVID-ER
SpeCldlty StructurdI Er1QIrwL-rlr1Q CBUCK, Inc Canifrote ofAuthoo,.tioo#8064
Florida Metal Products, Inc.
FLAMCO
"RV 10" Ridge Vent
2-1/4"
8-3/8" It 114 ]
"RV 10 Ridge Vent"
Profile View