HomeMy WebLinkAboutPRODAPPM IAM I�DADE MIAMI-DADS COUNTY
PRODUCT CONTROL SECTION
00 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) T786 1�5-2 90 6 F 786Street,R315-2 99
BOARD AND CODE ADMINISTRATION DIVISION ( )3
NOTICE OF ACCEPTANCE (NOA) wwwmiamidade.gov/economv
WinDoor, Inc.
7500 Amsterdam Drive
Orlando, FL 32832
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High Velocity Hurricane Zone.
DESCRIPTION: Series "9020" Aluminum Fixed Window — S.M.I.
APPROVAL DOCUMENT: Drawing No. 08-01635, titled "9020 Picture Window — Small Missile
Impact" sheets 1, 2, 2A, 3, 4, 5, 6, 7, 7A, 8, 9, 10 and 11 of 11, dated 06/20/12, with revision F dated
10/25/17, prepared by manufacturer, signed and sealed by Luis R. Lomas, P.E., bearing the Miami -Dade
County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the
Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA# 15-0812.20 and consists of this page 1 and evidence pages E-1. E-2
and E-3, as well as approval document mentioned above.
The submitted documentation was reviewed by Jorge M. Plasencia, P.E.
1�
NOA No. 17-0821.12
�� Expiration Date: November 29, 2022
t ? Approval Date: November 16, 2017
0�
Page I
WinDoor, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under previous NOA No.12-0627.06)
2. Drawing No. 08-01635, titled "9020 Picture Window - Small Missile Impact", sheets
1, 2, 2A, 3, 4, 5, 6, 7, 7A, 8, 9, 10 and 11 of 11, dated 06/20/12, with revision E dated
07/30/15, prepared by manufacturer, signed and sealed by Luis R. Lomas, P.E.
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Small Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94
along with installation diagram of an aluminum fixed window, prepared by National
Certified Testing Laboratories, Test Report No. NCTL-210-3778-1, Specimens 1, 2,
3, 4, 5, 6, 7, 8 and 9, dated 04/17/12, revised on 07/22/13 and updated on 09/27/13,
signed and sealed by Gerald J. Ferrara, P.E.
(Submitted under NOA# 124627.06)
2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Small Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94
along with installation diagram of an aluminum fixed window, prepared by National
Certified Testing Laboratories, Test Report No. NCTL-210-3778-2, Specimens 1, 2,
3, 4, 5, 6 and 7, dated 04/17/12, signed and sealed by Gerald J. Ferrara, P.E.
(Submitted under NOA# 124627.06)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC-Srh
Edition (2014), dated 09/05/14, prepared by manufacturer, signed and sealed by Luis
R. Lomas, P.E.
2. Glazing complies with ASTM E1300-04
r"
Jorge M. Plasencia, P.E.
Product Control Unit Supervisor
NOA No. 17-0821.12
Expiration Date: November 29, 2022
Approval Date: November 16, 2017
E-1
WinDoor, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. fox their
"SentryGlasg (Clear and White) Glass Interlayers" dated 06/25/15, expiring on
07/04/18,
2. Test report No. ATI-60520406.18, prepared by Architectural Testing, Inc., dated
11/09/06, with Revision #1 dated 11/29/06, issued to ENSINGER, Inc., for their
Tecatherm® 66 GF Insulbar Thermal Barrier plastic material per ASTM D635-
98 "Standard Test Method for Rate of Burning and/orExtent and Time of Burning of
Plastics in a Horizontal Position" and ASTM D2843-99 "Standard Test Methodfor
the Density of Smoke from the Burning Decomposition of Plastics ", ASTM 1]11929-96
(2000)e01 "Standard TestMethod for Ignition Properties of Plastics", also per
ASTM G 155-00ael "Standard Practice for Operating Xenon Arc Light Apparatus
for Exposure ofNon-Metallic Materials" and ASTM D63843 "Standard Test
Method for Tensile Properties of Plastics", signed and sealed by Joseph A. Reeves,
P.E.
(Submitted under NOA# 14-0I07.12)
F. STATEMENTS
1. Statement letter of conformance, complying with FBC-5t' Edition (2014). and of no
financial interest, dated July 30, 2015, issued by manufacturer, signed and sealed by
Luis R. Lomas, P.E.
2. Laboratory compliance letter for Test Reports No. NCTL-210-3778-1, and
NCTL-210-3778-2, issued by National Certified Testing Laboratories, dated 04/17/12,
all signed and sealed by Gerald J. Ferrara, P.E.
(Submitted under NOA# 12-0627.06)
G. OTHERS
1. Notice of Acceptance No. 14-0916.13, issued to WinDoor, Inc. for their Series "9020"
Aluminum Fixed Window - S.M.I. approved on 11/06/14 and expiring on 11/29/17.
Jorge M. Plasencia, P.E.
Product Control Unit Supervisor
NOA No. 17-0821.12
Expiration Date: November 29, 2022
Approval Date: November 16, 2017
E-2
WinDoor, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. 08-01635, titled "9020 Picture Window - Small Missile Impact', sheets
1, 2, 2A, 3, 4, 5, 65 7, 7A, 8, 9, 10 and 11 of 11, dated 06/20/12, with revision F dated
10/25/17, prepared by manufacturer, signed and sealed by Luis R. Lomas, P.E.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their
"SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on
07/04/18.
F. STATEMENTS
1. Statement letter of conformance to FBC-5th Edition (2014) and FBC-6o Edition
(2017), and of no financial interest, dated 10/19/17, issued by manufacturer, signed
and sealed by Luis R. Lomas, P.E.
G. OTHERS
1. This NOA revises and renews NOA #15-0812.20, expiring on 11/29/17I
Jorge M. Plasencia, P.E.
Product Control Unit Supervisor
NOA No. 17-0821.12
Expiration Date: November 29, 2022
Approval Date: November 16, 2017
E-3
NOTES:
THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE 5th. EDITION (2014) AND 6TH. EDITION
(2017) INCLUDING THE HVIIZ,
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FP.AMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE
ANCHORED THROUGH THE FRAME iN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS, ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL.
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
6. WHERE 1X BUCK ?S NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
THE ARCHITECT OR ENGINEER OF RECORD,
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
8. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE
SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
91 SHIMS SHALL BE MADE FROM MATERIALS CAPABLE OF SUSTAINING APPLICABLE LOADS,
LOCATED AND APPLIED IN A THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS.
i0, WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
1. FRAME MATERIAL: ALUMINUM 6063—T6.
2. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 6 FOR GLASS DETAILS.
3. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
REV
DESCRIPTION
REVISIONS
F REVISED PER NEW REQUIREMENTS
DATE
G/25/17
BORNE DEBRIS REGIONS WHEN INSTALLED ABOVE 307 HEGHT.
14.FOR ANCHORING NTO WOOD FRAMING OR 2X BUCK USE #12 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 7/16" MINIMUM EMBEDMENT INTO SUBSTRATE, LOCATE
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
5, FOR ANCHORING INTO MASONRY/CONCRETE USE 1/4" TIN BUILDE TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2
1/2" MINIMUM EDGE DISTANCE_ LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND
NSTALLATION DETAILS,
6. FOR ANCHORING INTO METAL STRUCTURE USE #12 SM'S OR SELF DRILLING SCREWS GRADE
5 WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR
WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS,
17. ALL FASTENERS TO BE CORROSION RESISTANT.
18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A,. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI,
C, MASONRY — STRENGTH CONFORMANCE TO ,ASTMI C-90, GRADE N, TYPE 1 (OR GREATER),
D. METAL. STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—TS 1/8" THICK MINIMUM
9 APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED AN AREA OF 50 SQUARE
FEET AS TESTED. GEOMETRIC SHAPES ARE NOT LIMITED TO SHAPES SHOWN HEREIN.
TABLE OE CONTENTS
SHEET
N0.
DESCRIPTION
NOTES
i
2 -
5
ELEVATIONS AND CHARTS
6 -
7
B.O.M. AND CROSS SECTIONS
8 -
9
INSTALLATION DETAILS
10 -
11
COMPONENTS
APPROVED
R.L.
SIGNED: 10/25/2017
PRODUCT REVISED � �^1 y 7500AVISTERDAIYIDRIVE \\%k ��Qr[It
/T
as complying with the Florida v • inn oo1 ORLANDO, FL 32832 \�� �Nej. • , ;.... • il,,,. //
Duilaing Code IN(GORPORAZ'FD Pho^c, 4o7.aeLWO . y..• •V�GEPlSF S
NOA-No. 17-0821.12 F:,.: 1*7.481oDS05 w .wiudoorinc.com
Expiration Date 11/29/2022 No;D 6 1
9020 PICTURE WINDOW
SMALL MISSILE IMPACT
Cdiami-Da Product Control NOTES
DRAWN. DING NO. REV �Q�•,. STATE OF
AIR 08-01635 F %, S
SCALE NTS DATE 06/20/12 SH:=ET I OF 11 /i/�OlNALIO\ `\
L. ROBERTO LOADS P.E. LUI9 R. Lomas P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
434-688-0609 rllomaa@Irlomaspe.com FL No.: 02514
120"
MAX
FRAME
HEIGHT
6" I
6`
MA%
60" MAX FRAME WIDTH -
�� 12'3 MAX O.C.
9020 PICTURE WINDOW
MAX
EXTERIOR VIEW
REFER TO CHARTS #f AND #1 IN SHEET 3 FOR OTHER UNITS RATINGS
DESIGN PRESSURE RATING
� IMPACT RATING
±i00.OPSF
SMALL
MISSILE IMPACT
WITH GLAZING A
DESIGN PRESSUAE AATING
IMPACT RATING
±90.0PSF
SMALL
MISSILE IMPACT
WITH GLAZING BAND C
91, M,AX FRAME WIDTH
6" MAX --� �-- f---�-t- 12" MAX O.C.
EXTERIOR VIEW
REFER TO CHARTS #1 AND #21N SHEET 3 FOR OTHEA UNITS RATINGS
DESIGN PRESSURE RATING
IMPACT RATING
± f f O.OPSF
SMALL
MISSILE IMPACT
WITH GLAZING A
DESIGN PRESSURE RATING
IMPACT RATING
±100.OPSF
SMALL
MISSILE IMPACT
WITH GLAZING 8 AND C
PRODUCT REVISED
as complying with the Florida
Building Code
tJOA-No. 17-0821.12
Expiration Date 11 /29/2022
Miami-DadWProtluct Control
REVISIONS
REV DESCRIPTION DATE APPROVED
REVISED PER NEW REQUIREMENTS 110/25/17 I R.L
72"
MAX
FRAME
HEIGHT
SIGNED: 1012512017
w IIZDoor O'LANDO,RD 8 2 � 1L1� ll��
J� ....:.....Mq
SLVCORPORAI'E.D shoor:wv�s�.e400 . V,IGENgF'•._(j� i
Pac 4N,481.0505 W .Wlndooriac.Com
9020 PICTURE WINDOW - No. 62514
SMALL MISSILE IMPACT = 7�� �* =
ELEVATIONS AND CHARTS —"� •%L tY,
DRAWN: DWG No. REV �i dT •`° STATE OF
A•P 08-01635 F :FSS'F ORtD?,•y,G
sca_E NTS DATE 06�2D�12 SHEETZ" OF 11 ///�OVAI-
0
L. ROBERTO LOMAS P.E. Luis R. Lomas P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023 FL No.: 62514
434-588-0609 HlomaSLOWQmaspe.com
MAX
i
72" MAX F*—
3
MAX
60"
MAX
20"
MAX
72"
MAX
120" MAX
60° 60"
MAX MAX
L L
120°
MAX
072"
MAX
120" MAX
A
1AX
t
APPROVED SHAPES
SEE NOTE 19 SHEET i
60X _
MAX _
V 7
" 20
MAX
72"
MAX
60°
MAX
PRODUCT REVISED
as complying with the Florida
Building Gode
NOA-No. 17-0821.12
Expiration Date 1/2912022
Miami-DadeAProduct Control
REVISIONS
ftEv
DESCRIFION
DATE
APPROVED
F
REVISED PER NEW REQUIREMENTS
10/25/17
R.L.
WinDoor
INCORPORATED
7500 FVIQSTERD�VI DRIVE
ORLANDQ FL 32832
enoae; o-ozasLea�
aN, un,aetosos www.windoorinc.com
9020 PICTURE WINDOW
SMALL MISSILE IMPACT
ELEVATIONS
DRAWN:
A.P
sca,:-E
NTS DATE
U4VG N0, RED
08-01635
F
/20/12 '"EET2A OF 11
L. ROBERTO LOMAS P.E.
1432 WOODFORD AD LEWISVILLE, NC 27023
434-688-0809 rllomasC@lrlomaspe.ccm
SIGNED: 10/25/2017
No. 62514
��T •, STATE OF
bw
Luis R. Lomas P.E.
FL No.: 62514
PARTS LIST
NO..
PART NUMBER
DESCRIPTION
MANUFACTURER
MATERIAL
1
iS-9020Al-WDI
FRAME HEAD AND SILL ASSEMBLY
KEYMARK
ALJMINUM 6063-T6
2
IS-9020A2-WDI
FRAME JAMB ASSEMBLY
KEYMARK
ALUMINUM 6063-T6
3
S-9020A3-0I
MULL ASSEMBLY
,KEYMARK
ALJMINUM 6063-T6
4
FH-06559
MULL INTERIOR REINFORCEMENT
KEYMARK
ALUMINUM 6005-T6
5
FS-06558
MULL EXTERIOR REINFORCEMENT
KEYMARK
ALUMINUM 6005-T6
6
S-49328
SCREW COVER
KEYIJ!ARK
ALUMINUM 6063-T6
7
S-49330
FLUSH ADAPTOR
KEYMARK
ALUMINUM 6063-T6
8
S-49329
9/16" GLASS STOP
KEYMARK
ALUMINUM 6063-T6
9
S-46084
1" GLASS STOP
KEYMARK
ALUMINUM 6063-T6
10
S-46083
1 3/8" GLASS STOP
KEYMARK
ALUMINUM 6063-T6
11
GSVN-07A
GLAZING VINYL
TEAM PLASTICS
80 DUROMETER
12
131014
#8x1" SCREW
STAINLESS STEEL
13
}18x1 3/4" SCREW
STAINLESS STEEL
14
#120 pr SCREW
STAINLESS STEEL
15
121000-121DOE1
RUBBER SETTING BLOCK
85 DUROMETER
16
SIKA 552
URETHANE SEALANT
SIKA
17
S-9020A8-50
CA RAIL ASSEMBLY
KEYMARK
ALUMINUM 6063-T6
18
1S-9020A5-WDI
MEDIUM RAIL ASSEMBLY
KEYMARK
ALUMINUM 5063-T6
19
S-9020A6-WDI
TALL RAIL ASSEMBLY
KEYMARK
ALUMINUM 6063-T6
20 I2206
INSULBAR
ENSINGER
TECATHERM 66GF
21
902AO7-WDI
CA RAIL FLANGE
KEYMARK
ALUMINUM 6063-T61
22
902AO9-WDI
HEAD AND SILL FLANGE
KEYMARK
ALUMINUM 6063-T6
23
902A11-WDI
JAMB FLANGE
KEYMARKALUMINUM
6063-T6
EXTERIOR
.035" SENTRYGLAS 8Y KURARAY
3/16" TEMP
ALUMINUM
SPACER SYSTEM
15/16" BITE
-�INTERIDR EXTERIOR
GLAZING DETAIL A
R'eVI510NS
REV DESCRIPTION DATE APPROVED
F REVISED PER NEW REQUIREMENTS I0/26/l7 :1R.L.
_R10R
KTERIOR
HORIZONTAL SECTION
6
3/16" TEMP 3/16" HIS
SENTRYGLAS BY KURARAY
i
TEMP VI6" HS
ALUMINUM
SPACER SYSTEM 5/16" BITE
EXTERIOR
3,/16" HS
035" SENTRYGLAS BY KURARAY
3/16" HIS
fNTERIOR
15/16° BITE
I� �I IIJ I
GLAZING DETAIL 8
r �i � c l � /NTERlOR
GLAZWG DETAIL C
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 17-0821.12
Expiration Date 11129/2022
Miami -Dade �foduct Control
EXTERIOR
A VERTICAL SECTION
6 STANDARD/STANDARD RAILS
FORA PROVED RAILS COMBINATIONS SEE SHEET 7
W11 7500 AMSTERDAiVI DRIVE
1IIDOOY ORLANDO, FL 32832
INCORPORATED Fnon� 407.451,8APJ
F=4WASI 10503 W .windoorincxom
9020 PICTURE WINDOW
SMALL MISSILE IMPACT
B.O.M. AND CROSS SECTIONS
DRAWN: 7777
WG N0. REV
A.P OS-01635 F
scA�e NTS DATE 06/20/12 1SHEET6 OF 11
L.
ROBERTO LOMAS P. E.
1432 WDODFORD RD LEWISVtLLE, NC 27023
434-688-0609 rllomasQlrlomaspe.cnm
S/GNED: 10/25/2017
��tllll 111 F!!�/
LO
�,.�}GENSg ''•,S
No. 825144/�_
STATE OF
/�NAL lE
Luis R. Lomas P.E,
FL No-i 62514
FxrFRInR
„TERIOR
CA/TALL RAILS
IT
EXTERIOR Ti-r INTERIOR
FxTFRInR
„�TERIOR
CA/MED(UM RAILS
EXTERIOR INTERIOR
EXTERIOR
rwry_ni�lr�
„r,'ERIOR
JTERIOR
STANDARD/CA FiA/LS STANDARD/MEDIUM R,41LS �1EDIUM/MEDIUM RAILS
OWN
FOR OTHER ITEMS SEE VERTICAL
CROSS SECTION SHEET 6
`�11 Full
FYTRR INTERIOR
STANDARD/TALL RAILS
uJTERIOR
MEDIUM/TALL RAILS
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 17-0821.12
Expiration Date 11 /29/2022
Dad roduct Control
REVISIONS
REVS
DESGR PTION
h
REVISED
PER
NEW REQUIREMENTS
INTERIOR
TALUTALL RAILS
'(�% 7� 7500A.bISTERDAMDRIVE
VV �LOOY ORLA.NDO,PL32832
INCORPOATED rho= 407.481.8400
d
R
4m.4a1.0505 anxm,.w_n oonnacom
9020 PICTURE WINDOW
SMALL MISSILE IMPACT
APPROVED RAIL COMBINATIONS
A.P 08-01635 F
SCALE N-�S DATE 06 /20/12 SHEET? �F 1
L. ROBEATO LOMAS P.E.
f432 WOODFORD RD LEWISVILLE, NO 27023
434-688-0609 dlomas@Irlomaspe.com
GATE APPROVED
10/25/^:7 R.L.
FL
SIGNED: l0/25/2017
,\�If1il ll fAi l///
�..•' OCENS� tP
No. 62514441
=_
Qom•, STATE OF 44"
/ONAL E
Luis R. Lomas P.E.
No.: 62514
EXi
INTERIOR
HEAD AND SILL FLANGE
EXTERI
FOR OTHER ITEMS SEE VERTICAL AND HORIZONTAL
CROSS SECTIONS SHEET 6
CA RAIL FLANGE
INTERIOR
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-NO. 17-0821.12
ItItIbbItItt
Expiration Date 11/29/2022
Miami ad roduct Control
REVIS ONS
REV
JAMB FLANGE
7500 ANISTERDAM DRIVE
W1f1DOOY ORLANDO,FL32832
INCORPORATED Phom: C7.asts400
Pa 407.48 LR505 w .wmdoovnczom
9020 PICTURE WINDOW
SMALL MISSILE IMPACT
APPROVED RAIL COMBINATIONS
DWG
DRAWN:
N0, REV
A.P 08-01635 F
ALE NTS OATS 06/20/12 1
SHEEr7A OP 11
L. R06ERT0 LOMAS P.E.
9432 WDODFORD RD LEWlSVILLE, NC 27023
434688-0609 rllomasOo lrlomaspe.crom
GATE APPROVED
�0/25/17 R.L.
SIGNED: 10/25/2017
rr
Lp
\..•' L\GENSF '•.S i
No. 6251 4
STATE OF
' �rS�ONAL tea \
Luis R. Lomas P.E.
FL No.: 62514
REVISIONS
9/16" MIN. REV DESCRIPTION DATE APPROVED
EDGE DISTANCE
1/8" MiN. F I REVISED PER NEW REQUIREMENTS 10/25/17 R.L.
WOOD FRAMING METAL EDGE DISTANCE
OR 2X BUCK STRUCTURE
BY OTHERS 7/16" MIN. BY OTHERS
EMBEDMENT
APPROVED APPROVED
MAX7 MAX.
SEALANT . SEALANT , /4" 1 1 5/8" MIN, 1/1 MAX.
SHIMVI SPACE -- SHIM SPACE EMBEDMENT SHIM SPACE
INTERIOR
#12 WOOD 9/16" MIN.
SCREW EDGE DISIANCE
#12 SMS OR O
EXTERIOR SELF DRILLING
SCREW
#12 WOOD INTERIOR EXTERIOR INTERIOR #12 WOOD
SCREW #12 SMS OR SCREW
SELF DRILLING WOOD FRAMINGIIX
SCREW OR 2X BUCK '�
APPROVED APPROVED BY OTHERS APPROVED EXTERIOR
SEALANT, _ 1/4" MAX. SEALANT SEALANT
SHIM SPACE 1/4" MAX.
SHIM SPACE B
_ JAMB INSTALLATION DETAIL
WCOD FRAMING 1 7/16" MIN. METAL 8 WOOD FRAMING ORZXBUCK INSTALLATION
OR 2X BUCK EMBEDMENT STRUCTURE
BY OTHERS BY OTHERS
9/16° UI'N.
EDGE DISTANCE
A VERTICAL CROSS SECTION
8 WOOD FRAMING OR 2X BUCK INSTALLATION
VERTICAL CROSS SECTION
S METAL STRUCTURE INSTALLATION
7/8" MIN.
EDGE DISTANCE
SHIM SPACE
7/8" MIN.
EDGE DISTANCE INTERIOR
i
O,
PRODUCT REVISED
_ as complying with the Florida
Building Code
#12 SMS OR Ivoa-No. 17-0821.12
SELF DRILLING SCREWS 1 Expiration Date 11/2912022
By
METAL 1
STRUCT TA EXTERIOR Miami-D Product Control
BY OTHERS APPROVED NOTES:
SEALANT 1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS,
B JAMB INSTALLATION DETAILNOT SHOWN FOR CLARITY.
METAL STRUCTURE INSTALLATION • PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
�1riDO0Y
mcoxPoxArFn
A.P
7500 AMSTSRDAbi DRNE
ORLANDO, FL 32832
Phois: 40'l.J81.8400
Pam: unsrrs www.windoorinc.com
9020 PICTURE WINDOW
SMALL MISSILE IMPACT
NSTALLATION DETAILS
scA--
NTS � DATE
08-01635 IRF
20/12 IsI-.EFTS OF 11
L. RpBER70 LOMAS P.E.
1432 WOODFORD RD LEWISVKLE, NC 27023
A34-688-0608 rllomas@Idomaspe.com
SIGNED: 1 D/25/2017
``\lrin n rrlr�
�.•' �lGENSF''•,tq ,
No. 62514
��Q� •, STATE OF •' t(/411�
01111100,
Luis R. Lomas P.E.
FL No,: 62514
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1 X BUCK
S=E NOTES 3-7 SHEET 1
APPRO'JED
SEALANT
1/4" TAFCON
EXTERIOR
1/4" TAPCON
APPROVED
SEALANT
OPTIONAL 1X BOCK
SEE NOTES 3-7 SHEE7 1
CONCRETE/MASOPJRY
°a
4
8
t2 11/2" MIN.
EDGE DISTANCE
VERTICAL CROSS SECTION
9 CONCRETE/MASONRY INSTALLATION
2 1/2" MIN.
EDGE DISTANCE
a e
EMBEDMENT
f
1 1/4" MIN.
EMBEDMENT
4 CONCRETE/MASONRY
BY OTHERS
/4" MAX.
SHIM SPACE OPTIONAL 1X BUCK
SEE NOTES 3-7 SHEET 1
INTERIOR
1/4" MAX.
SHIM SPACE
1 1/4° MIN.
°°. EMBEDMENT
NOTES
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
1/4" T.APCON
MIN.
EDGE
DISTANCE
1
REVISIONS
REV
DESCRIPTION
I DATE
APPROVED
F
REVISED
PER
NEW REQUIREMENTS
110j 25/1.7
R.L.
1 >9 1/4" MAX.
SHIN SPACE
i
�a
INTERIOR
v � i
o`
a EE�
d o l
I EXTERIOR
APPROVED
SEALANT
JAMS JAMS INSTALLATION DETAIL
9 CONCRETE/MASONRY INSTALLATION
SIGNED: 10/25/2017
PRODUCT REVISED WinDOOY ORLANDO, 832�� �`�\\ , R ILO 1111%,
as complying with the Florida \ `�`Cj ,;-, , /��
Building Code INCORPORATED Ph6ne:407.491.8400 '\)GENSF''
NOA-No, 77-0821.12 Pax Q7 J.o505 Nw .windooxina.com
Expiration Datell/29/2022 9020 PICTURE WINDOW _ /j No. 625144 =
ey SMALL MISSILE IMPACT _ * ; //*
Miami- ad roductt:ontroi INSTALLATION DETAILS -� 22,
A111�
DRAWN: DWG NO. REVQ�,-. STATE OF (rw�
A.P OB-91 635 F OR4DP.-'\_
SCALE NTS DaTE 06/20/12 SPEET9 OF 11 II,Sr/ONA4-1�
L. ROBERTO LOMAS P.E. Luis R. Lomas P.E.
1432 WOODFORD RD LEWISVILLE, NO 27023 FL No.: 62514
434-688-0609 rllomw@irlomaspa.com
3 3/16"
FRAME
ALUMINUM 6063-T6.080" THICK
L'
5/8 1 1 /r1 6-F Hi --
I
)REINFORCEMENT
ALUMINUM 6005-T61 .100"THICK
q
FRAME
AL UMINUM 6063-T6.080" THICK
/
11/16" 1 1/16"
O5 REINFORCEMENT ALUMINUM 6005-T61.080"THICK
FLUSH ADAPTOR
ALUMINUM 6063-T6.065" THICK
T--A
1/4"
n 1 3/8"GLASS STOP
.063"THICK
3/8" --
T
5/8"
9/16"GLASS STOP
.063" THICK
INSULBAR
70 TECATHERM 66GF.0i5"THICK
3 7/8"
17 CA RAIL
ALUMINUM 6063-T6.100" THICK
3
OMULL ASSEMBLY
ALUMINUM 6063-T6.080" THICK
SCREW COVER
OALUMINUM 6063-T6.050"THICK
5/8"
1 "GLASS STOP
.063" THICK
23 JAMB FLANGE
ALUMWUM 6063-T6.080"THICK
4
REVISIONS
REV DESCRIPTION DOTE
— 3 3/16 F REVISED PER NEW REQUIREMENTS 10/25/17
2 3/16
z2 HEAD AND SILL FLANGE FRAME
ALUMINUM 6063-T6.080" THICK
z1 CA RAIL FLANGE
ALUMINUM 6063-T6 . i 00"THICK
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 17-0821 A 21/2 Expiration Date 912022
Miami -Dad roduct Control
18 MIDDLE RAIL
ALUMINUM 6063-T6.080" THICK
WinDoor
INCORPOATED
R
5 7/8„
APPROVED
R.L.
19 TALL RAIL
ALUMINUM 6063-T6.100" THICK
7500 AMSTERDAM DRIVE
ORLANDO, FL 32832
Phone: 90'/.J81.A400
F,=. w�.as�.asos www.windoorinc.com
9020 PICTURE 4VINCtOW
SMALL MISSILE IMPACT
COMPONENTS
DRAWN:
CWG N0
A.P 05-01 635
scA_E NTS I DATE 06/20/1 2 10 OF 11
L A08EAT0 LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
434-688-0609 rllomas@lrlomaspe.com
SIGNED: 10/25/2017
LO
vvvviiunllrr
�''OGEN
�No 66t2�5141
Q STATE. OF Gq
sS/ONAL 0 `N'
lrrr llfjiI 0 0
Luis R. Lomas P.E.
FL No.: 62514
C
� � HORIZONTAL INTEGRAL MULLION
SQUARE DRI
SCRE1
�M RAIL
PRODUCT REVISED
as complying with the Florida
Building Code
NOA-No. 17-0821.12
Expiration Date 1112912022
Miam ad ~oduct Control
REVISIONS
REV
DESCRIPTION
DATE
APPROVED
E
REVISED PER NEW REQUIREMENTS 110/25/17
R.L.
Wf11DO0Y
IN
7500 AMSTHRDAM DRIVE
ORLANDO, FL 32832
40?,40t.0400
Fa: 40?.491.D505 www.vrindoovnc.com
9020 PICTURE WINDOW
SMALL MISSILE IMPACT
COMPONENTS
oRA\roN,
A.P
Dwc No,
08-01635
Rev
F
SCALE NTS
NTS
DATE
DATE 06/20/12
SHEET 1 1 OF 1scALE
OF 1 1
L. R08ERT0 LOMAS P.E.
1432 WOOOFORD.RO LEWfSV1LLE, NC 27023
434-688-0609 rIlomasL�lrlomaspe.com
SIGNED: 70/25/2077
`\t\:1fl ll fll ll//
,. L:diLp,,
ENSF ' •. CP
STATE OF
sS� �\��•
�NAI- \E
Luis R. Lomas P.E.
EL No.: 62514