Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Design Pressure Report (Dennis or Edith Bryant) -
Property Information Owner:Dennis or Edith Bryant Address:6255 Arlington Way Fort Pierce, FL 34951 Building Information Wind Zone:170 MPH. Exposure Category:C Minimum Building Dimension:35 ft. Mean Roof Height:12 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 36 96 7 35.6 -38.8 2 Int 38 27 7 37.8 -41.0 3 Int 35 61 7 36.8 -40.0 4 Int 35 61 7 36.8 -40.0 5 Int 35 61 7 36.8 -40.0 6 Int 34 35 7 37.8 -41.0 7 Int 16 35 7 37.8 -41.0 8 Int 104 61 7 34.2 -37.4 9 Int 95 96 7 33.3 -36.5 10 Int 52 72 7 35.4 -38.7 11 Int 24 72 7 37.3 -40.6 12 Int 25 72 7 37.2 -40.5 13 Int 25 72 7 37.2 -40.5 14 Int 25 72 7 37.2 -40.5 15 Int 35 72 7 36.4 -39.6 16 Int 35 72 7 36.4 -39.6 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1