Loading...
HomeMy WebLinkAboutSURV (SCREEN). r ru 79". i. let. . Ti � �- Gj I Flo (1] U n) rt) v1>1 i CA) "D 199 I Pv �v cw rnTO Ps no ry GW • w iJ'u 6 -ph. 00 Z M _ f P �5 rM rim �ru nu Lfl M TFU AWLZIAZOOOO m ru c- AZTV ,L vi -� P � Z x r o � j no �,LfOOO .*F'Rop x GO Wi I ro ri ' z0 0 p w4_ _ r f, ru C�II Cfi Tvru! nm u CA �j IFUM ro n �.� I; r\i WPW f es i �� -n 4n es 3' x 3' x 0.050' MIN. 6063-T6 ALLOY PLATE OR STRONGER (ONE SIDE) WITH (3) - #12 x % S.M.S. EACH SIDE AS SHOWN (%' MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) 3' x 2' x 0.050' MIN. 6063-T6 ALLOY PLATE OR STRONGER (ONE SIDE) (3) - #12 x �'i S.M.S, EACH SIDE AS SHOWN (Y2' MIN. PLATE EDGE DISTANCE 8 C-C FASTENER SPACING) FOUNDATION (5) #12x3/4" S.M.S. 1x2 O.B. ATTACHED TO BEAM W/ (2)-#10X2" S.M.S. INTO SCREW BOSS (1)-1/4'4" S.S. THRU-BOLT AND ® EACH NUT DE OF BEAM WASHER #12z2" S.M.S. ® 24" O.C. ix2 O.D. TO SUPER GUTTER (4) #12x3/4" S.M.S. ROOF BEAM (FLAT OR SLOPED) . ( )-2x24" ANGLE, EACH 2 1 FOR 2x8 SMB OR LAS CORNER POST EAVE RAIL (11 TOTAL) - #12 x 44' 1' x 2' O.B. S.M.S AS SHOWN (Yz' MIN. PATIO SECTION PLATE EDGE DISTANCE & C-C FASTENER SPACING) C 6' x 5' x 0.050' C 6063-T6 ALLOY PLATE C 0 (ONE SIDE) OR STRONGER K-BRACE 2x3xO.070 CHAIR RAIL K-BRACE K-BRACE CORNER POST K-BRACE I' x 2' tOLE PLATE -Ya' 0 CONCRETE ANCHOR <2 PLACES) IN LIEU OF TYP. y' 0 CONCRETE SCREWS FOR CORNER COLUMN (4) #120/4" S.M.S.-/ EACH LEG. 5' or 7' SUPER GUTTER MIN. 0.090' THICK LATERAL "K" - BRACING CONNECTION DETAILS COLUMN GIRT (CHAIR RAIL) x SEE ELEVATIONS FOR 'K' BRACE SIZE 1x5xW ANGLE 6' LONG -(TYP. @ EACH BEAM) (2) )4'0x3' LG. @ EACH ANGLE NOTE: PRIMARY SCREEN ENCLOSURE BEAMS SHALL BE ATTACHED TO HOST STRUCTURE CONSISTING OF CONVENTIONAL TRUSS/RAFTER FRAMING WITH MAX. / FACIA TO BE 2x6 (MIN.) S.P.F. OVERHANG NO TO EXCEED 30' UNLESS OTHERWISE 1./ OR WESTER RED CEDAR NOTED ON PLAN DWG. \) STRUCTURAL GRADE 2 MIN. (D y'0x2' LG. LAG SCREW @ 24' O.C. ENTIRE LENGTH [IF GUTTER ROOF BEAM TO SUPER GUTTER CONNECTION DETAIL S�M�R�G BEAM STITCHING SCREWS (SEE TABLE) @ 24' O.C. SPACE SCREWS SPLICE PLATE (EACH SIDE OF BEAM) D K I M EQUALLY (TYP.) A ,({ 5052-H32 ALLOY OR EQUAL, 1/8' THICKNESS & ASSOCIATES, LLC CONSULTING A o= o STRUCTURAL osr�� 8W CoENGINEERS PO Box 10039 yy � #14x44' SCREWS Tel: (813) 374-0321 <xx) <xxx) <xxxx) Q- p A .�511 BEAM LINE LINE' SCREWS ' A B'&'CTOTAL PLATE WIDTH Rev./Dat Description 0 20 5 ISSUED y`.SLQ' HPD 31 Lt 2�P� 2x4 3 2 24 12' B QPG�z /0 C LtKPT M• VNE tOtN ' cR 2x5 3 3 32 14' Q 'Jar 2x6 4 3 40 14' Q B V��\Dj� �.•** 2x7 5 4 56 16' 2x8 5 5 64 16' 0 P�tE 2x9 5 6 72 18' MANSARD BEAM 2x9(HW) 6 7 88 18' CONNECTION DETAIL 2xIO 7 1 7 96 18' 1x1xvs" BY 2" LONG ANGLE, EACH SIDE (TYP 2x3xO.O70 GIRT/CHAIR RAIL (SEE PLAN) MIN. (4) #10x2" LONG (4) #14A' S.M.S.. S.M.S. INTO SCREW BOSSES 2 SCREWS (TYP. ALTERNATIVE) EACH LEG (TYP.) S.M.B. POST HOLLOW POST SECURE FASCIA TO EACH RAFTER TAIL x W/ (U y'0x4' LONG PAN HEAD LAG SCREWS (2) B10x4' S.M.S. THRU. 2x3 .--f. BEFORE ATTACHING SUPER GUTTER SAVE RAIL INTO PURUN SCREW BOSSES USE #10x%" S.M.S. ® 24" O.C. TO CONNECT TO 1x2 O.B. TO 2x3. 11) Y4 OX2' LG. LAG SCREWS ((TYP. @ EACH BEAM) 1x2 O.B. FASTENED TO COLUMN/POST f� l 11)#12x2' S.M.S @ 12' o.c. W/(2) #10OX" S.M.S. INTO SCREW BOSSES ,MAX) BETWEEN BEAMS (EACH END, TYP.) 2z� !{s' THICK CONTINUOUS ANGLE —SECURE FASCIA TO EACH RAFTER TAIL W/ (1) Yi 0x4' LONG PAN HEAD LAG SCREWS BEFORE ATTACHING SUPER GUTTER #100/4" S.M.S. Y,' CONTINUOUS BEAD OF CONSTRUCTION ® 2' O.C. ADHESIVE (3) 12x>4' S.M.S., EACH LEG AND MIN. (4) #10x3" LONG S.M.S. INTO SCREW BOSSES (TYP. ALTERNATIVE) (6) #12A' S.M.S. CHANNEL TO BEAM (9) SCREW TOTAL BEAM STITCHING ® 24` O.C. 0 (TYP. TOP AND BOTTOM OF SMB J PURDN 70 SEE TABLE FOR SIZES) — Q W U p W 7-7 U BRAKE -FORMED RECIEVING CHANNEL (MIN. 0.062" MATERIAL THICKNESS) 1" x 2 1/8" x 1" x 3" LG. (TYP. ALTERNATIVE) CHAIR RAIL / GIRT TO POST CONNECTION DETAIL 2x3XO.O45 EAVERAIL ATTACHED TO BEAMS WITH (3)-#10x2" S.M.S. 2x PURLIN INTO SCREW BOSS. (MAY BE SLOPED OR FLAT) 2x5x.125 ANGLE-2' WIDE WITH M-114.1" INTO BEAM & (2)-#14xl INTO USE #10x%" S.M.S. ® 24" O.C. � TO CONNECT TO 1x2 O.B. TO 2z3. PURDN FASTENED TO COLUMN/POST WITH (4) #12xl" S.M.S. (EACH LEG) (g) A72.%" S.M.S. EACH SIDE USING )fi" THICK FLAT BAR BEM OF BEAM (TYP.) OR (6) #12x34" S.M.S. EACH SIDE TO FIT (6063-T6 ALLOY) OF BEAM FOR 2x5 COLUMN TO 2x5 BEAM \ COLUMN/POST COLUMN/POST SIDEWALL POST / COLUMN TO PURLIN CONNECTION DETAIL PURLIN TO ROOF BEAM CONNECTION DETAIL U .. d U � 3' LONG vi ANGLE, EACH SIDE (TYP.) O J (3) #12,X" S.M.S., EACH U LEG (6) TOTAL (TYP.) z W U) z z � o O � Z Q z U U W (n a _I W } U � � DRAWN BY: DYK CHECKED BY: DYK S.M.B. BEAM SCALE: AS SHOWN MAY BE SLOPED OR FLAT (SEE PLAN FOR SIZE) DATE: 8/11/06 W MIN., 3 Yz' MAX. C-C SPACING OF FASTENERS (TYP.) Y2' MIN. BEAM EDGE DISTANCE (TYP.) MAIN POST / COLUMN TO ROOF BEAM CONNECTION DETAIL DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM AS IATES, LLC A# 268 P ox 1 9 Tamp , F 9 J.Z.e.t v Drawing No. - 060811 SHEET 1 OF 3 C� PURLIN SUPPORT COLUMN/POST )6' ANGLE, EACH SIDE (TYP.) 2x2x1/8" x 2" I.G. ANGLE S.M.S. WITH MIN. ' %"0 CONCRETE ANCHOR W/ (4) #12x3/4' S.M.S EDGE DISTANCE W/2%- EMBEDMENT INTO (EACH SIDE) STRUCTURAL CONCRETE (TYP., CONCRETE EE NOTE 10) 1 "x2' O.B. SOLE PLATE oC INOR W/2% EMBEDMENT 2"x PURUN STRUCTURAL CONCRETE (EACH SIDE) c BEAM MAY w a�- Y4"Ox2Y4" CONCRETE BE FLAT E.it SCREW ANCHOR ® 24' O.C. OR SLOPED uu *mo NV AND 9- FROM POST (TYP.) SIDEWALL COLUMN TO CONCRETE CONNECTION DETAIL SEE PLAN FOR SIZE 1x2 O.B. FASTENED TO CORNE SECTION WITH #14xU4" S.M.S.1 24' O.C. 2x24' ANGLE 2" LONG (EACH W/(2) #14x-" S.M.S. To POS & 3/8"0 H.D. GALV. EXP. BOL W/ 2 1/2' MIN. EMBEDMENT CORNER POST / COLUMN TO CONCRETE CONNECTION DETAIL S.M.S. WITH 1—ix!- IN." Ys" ANGLE, EACH SIDE (TYP.) EDGE DISTANCE %-0 CONCRETE ANCHOR W/2%- EMBEDMENT INTO STRUCTURAL CONCRETE (TYP., 5 SEE NOTE 10) x 1'x2' O.B. SOLE PLATE EDGE OF CONCRETE .4 J 3" MIN. (TYP.) z Y'Ox2Y" CONCRETE _ SCREW ANCHOR 0 24" O.C. = = AND 9" FROM POST (TYP.) �dO u H EDGE OF CONCRETE COLUMN/POST 1x2 O.B. SOLE PLATE I 1' (TYP.) . i N = PLAN VIEW MAIN COLUMN TO CONCRETE CONNECTION DETAIL PLAN VIEW COLUMN/POST >`� O.B. SOLE PLATE I 1' (TYP.) X r < 1\ PLAN - TYPICAL DIAGONAL ROOF BRACE CONNECTION 2x2A- ANGLE CUP, CUT AT A 45' (+/-) ANGLE AND ATTACHED TO THE SCREEN ROOF BEAM WITH ONE (1) Y,"O THRU- BOLT, FENDER WASHER. ATTACHEDEDBTO BEAM OR EAVE RAIL / DIAGONAL BRACING SHALL NOT BE ATTACHED TO ROOF PURLINS. 2x2xO.093 BRACE (SEE PLAN) 1+1 Ix3 O.B. FASTENED TO CORNER SECTION WITH #lOx2" S.M.S. W/ %" DIA WASHER ® 18" O.C. 2x5xYa' ANGLE (2' LONG) W/ (2)-#14 TEKS INTO TOP OF 2x3 EAVE RAIL AND (2)- #14 TEKS INTO THE FRONT OF THE CORNER POST L 1x2 O.B. TOP FRAME CORNER POST -1x O.B. SIDE WALL CORNER UPRIGHT ELEVATION VIEW CORNER POST / COLUMN UPRIGHT DETAIL 2500 PSI MIN. CONCRETE STRENGTH COLUMN d 2J4' MAX. THICK BRICK PAVERS APPROXIMATE11— ,,44LIN MORTARMORTAR ON TOP OF FOOTER * C' =I I ° I I I I I I d gj O.B. SOLE PLATE -III d d III N -I II III r�COMPACTED OR =1—III 4 4 III UNDISTURBED SOIL/SAND =1I ° d (1)-#5 REBAR, CONTINUOUS -III III —II 3" MIN. CONC. COVER, 36" MIN �I -II I� I I -I I I -I I =III= LAP SPLICE y.�` --III; I I-ITI-TIl I I \\ 12" MIN.t MIN. CONTINUOUS PERIMETER FOOTING (4) #12xY4' 2"x PURUN BEAM MAY BE FLAT OR SLOPED (2) #10x2Y2 TYP. EACH (2) Q10xA TYP. EACH PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 RNATE (1) j' ANGLE E 'x)6' ANGLE (BRACE) W/ '12x3'4 S.M.S. 0 EACH IER INTERSECTION e ANGLE 2' LONG ON RSIDEW/(4) #12x3j" S.M.S. LEG (BEAM & BRACE) 3RACE PLAN) ALTERNATE (2) 2x3 BRACE DO KI M & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 0 71271 2015 ISSUED 0 0 A J W ci � c W U W O J L- Z V W in Z 4) W N W c Z Of O CL F- U) J Z W 'U^U VJ n Lu >- U O DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 8/11/06 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM AS CIATES, LLC 7 ox 10039 Tampa, FL 33679 FOUNDATION/SLAB DETAIL Drawing No. - 060811 SHEET 2 OF 3 Genera! Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 9005-T53 Alloy, 6005-T5 Alloy; for secondary components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6 7 8. Unless otherwise noted, SMB shall be stitched with #100/4" SMS at 24"o.c., top and bottom. Connections using screw bosses shall have minimum (4)410x2" per connection unless shown otherwise. Unless otherwise shown, screws shall have minimum edge distance and center -to -center distances as shown in this table. 1-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 5/16" 1/z" #12 0,219 3/a" 9/16„ #14 (1/4") 0.250 +/2" 5/8" 9. Structure has been designed to meet the 611, Edition FBC (2017 FBC), Project is sited where the ultimate design wind speed, Vu11 is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure C. Design pressures are from Table 2002.4, 2013 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASO). 10. Concrete anchors may be "Large Diameter Tapcons" (LTDs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal, 11. Screen enclosure structure shall meet Section 454.2.17 Residential Swimming Barrier Requirements and the screen enclosure per 454.2.17.1.11. if enclosing a pool. D❑ KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 Rev atd Description Qp 2D 7 ISSUED 0 0 J Q w U � C _ U.1 U u O N U U z C/) LU (1)w C Z of a O = �U h J Q z U U w _I W } U 0 F- DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 8/11 /06 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DOLA ATES, LLC 7 039 Drawing No. - 060811 1 SHEET 3 OF 3