Loading...
HomeMy WebLinkAboutEXTREME METAL 5V CRIMP APPROVAL NUMBER 17022.1160 SW Poma Drive Palm City, FL 34990 (772)872-8034 Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install Details: Table A Allowable"Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o.c. 16" O.C. 8" O.C. 6" ox. FASTENER SPACING (ALONG Panel width) 12" o.c. 12" o.c. 12" ox. 12" o.c. FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test Report EMS93.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897.1? *Design pressure margin of safety 2.-1..w1 ir�1r�.. Locke BowdenrP,E. does not have, not will acquire a financial inter} .10? rl�►rn lacturing or distributing products under this evaluation.® Locke Bowden, P.E. is not owned, operated, or controlled by air coin pariVpn— iiifasrturem, or distributing products under this report. a ;7Z7 / Ivry �. FL17O22.1 5V Crimp (26GA Steel), 24" Wide Roof Panel -Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 61t' ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference- 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wljurisdiction is allowed by other registered engineers- 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 1513T or greater Plymod, or - Wood plank .00 14- 3rs' 1r OPMNar. STREAMONS Panel Profile Nominal 12" E , Nominal 12" O.C. `i' O.C. Fasten f9 x 1-1/2" Min. or #10 x 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c, across the Panel V\Adth Panel Refer to Table "A" for Spacing Along Panel -Overlap Length Deck-15/32" or greater Plywood, or - V1bod plank