HomeMy WebLinkAboutProduct approvals, Integrity 5 V 2020Business :Professional Regulation
SCIS Home log In I User Registration I Hot Topic Submit Surcharge Stats & Facts Publications Contact Us ' BCIS Site Map Links Search
bproduct
Approval
USER: PubEic User .,,...r
Prod -I 1-d ,. Aimtlra r.• ____ y��l caxiun I-r.�r s Application Detail
FL # FI_29444
Application Type New
Code Version 2017
Application Status Approved
Comments L.+
Archived
Product Manufacturer Integrity Metals LLC
Address/Phone/Email 2604 B Piper Drive
Vero Beach, FL 32960
(772) 584-2654
Admirt@integritymetalsfi.com
Authorized Signature Joe Keene
Admin@integritymetalsfi.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Locke Bowden
the Evaluation Report
Florida License PE -49704
Quality Assurance Entity PRI Construction Materials Technologies, LLC.
Quality Assurance Contract Expiration Date 05/25/2023
Validated By Diane Marotta, P.E.
- Validation Checklist - Hardcopy Received
Certificate of Independence FL29444 RG COI Integrity Metals Integrk ok dM 100 Min 029 AL Nail
Ship - C,55.0d
Referenced Standard and Year (of Standard) Standard Year
LL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
04/17/2019
Date Validated
04/17/2019
Date Pending FBC Approval
04/26/2019
Date Approved
06/18/2019
5ummary of Products
FL # Model, Humber or Name
Description
29444.1 IntegriLok IM100 Min. .029" AL Nail
IntegriLok IMiOO Min. .029" AL Nail Strip
Strip
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL29444 RO II lnteui itv i1etals IntegriLok IM 100 Min .029
A.L_I 1. ii Strip - CSS.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -153.5
Created by Independent Third Party: Yes
Other: -153.5 psf @ 5-1/4" O.C. WITH adhesive -57.62 psf
Evaluation Reports
@ 5-1/4" O.C. WITHOUT adhesive Install per manufacturer'sF
? Jrity Met3fs InteciriLok IM 100 Min
instal} details and in accordance with FBC 2017.
_
Ozsi i) i1 "rn_ C S.pd_f
Created by Independent Third Party: Yes
29444.2
Min. 26GA Galvalume IM36 AG
Min. 26GA Galvaiume IM36 AG Panel over OSB & CDX
Panel
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
irpgrit)Metals Min. 26GA Galvalume IM36
Approved for use outside HVHZ: Yes
=
Impact Resistant: N/A
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -93.5
Created by Independent Third Party: Yes
Other: -93.5 psf @ 12" O.C. Fastening Pattern:
Evaluation Reports
9"x9"x9"x6.5"x2.5° -78.5 psf @ 18" O.C. Fastening Pattern:
FL29444 RG AE Integrity Metals Min. 26GA Galvalume
iM36 A.G Panel - CSS.ndf
9"x9"x9"x9" Install per manufacturer's details and in
accordance with FBC 2017.
Created by Independent Third Party: Yes
29444.3 Min. 26GA Steel 1.5" Snap Lock
Min. 26GA Steel 1.5" Snap Lock over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
h4 ui 75GA Steel 1.5 Snap
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -86
Created by Independent Third Party: Yes
Other: -86 psf @ 12" O.C. Install per manufactuer's install
Evaluation Reports
details and in accordance with FBC 2017.
FL29444 RA AE integrity Metals Min. 26GA Steel 1.5 Snap
I rrk rec�clf
Created b nt Third Party: Yes
29444.4 Min. 26GA Steel 5 V Crimp Panel
Min.26GA Steel 5 V Crimp Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
1-7.-4 ' - = ea iry Metals 5 V CrnTIU Pane€ - CSS.oclf
Verified By: Locke Bowden, RE. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressures +N/A/ -116
Evaluation Reports
Other: -116 psf @ 12" O.C. Install per manufacturer's
7 "` t ,,_MeLdis 5 V rrjn PaneCSS.hDdf
details and in accordance with FBC 2017,
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee Fl- 32399 Phone: 850-487-1824
The State of Florida is an AA/EEG employer. Copyright 2007-2,013 Stpte of Fio.rida.:: Privacy Statement :: Accessibility Statement :: Refund statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a publicrecordsrequest, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emalls provided may be used for official commun kation with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the bepartment with an email address which can be made available to the public. To determine if you are a licensee order Chapter
455, F.S., please click here .
Product Approval Accepts:
rT F VIA
Credit Card
Sate
INTEGPITYMETALs
Compliant with Florida Building Code 2017 (6t' ed.)
Compliant with Florida Product Approval Rule # 611320-3
Compliant Active Quality Assurance Program
Product: Min. 26GA 5V Crimp Roof Panel FBC Sec. 1507.4.2
2604 8 Piper Drive
Vero Beach, FL 32960
772-284-5613
Yield strength: 50ksi 24" Coverage (Max.) Rib Height 3/8"
Minimum 15/32" plywood over supports at maximum 24" O.C. Design of plywood
and plywood supports are outside the scope of this evaluation. Must be designed
in accordance w/ Florida Building Code 2017.
34" penetration thru plywood supports 24" max. o.c.
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener: #10-15 Woodtite fastener spaced @ 12" O.C.
Underlayment: To be compliant with FBC Sec. 1507, Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable
Loads
Method 1:
DESIGN PRESSURE*
-116 PSF
SPACING
12" O.C.
Reference Data:
Intertek Testing (TST 1527) REPORT # 17226.03-450-44 RO UI. S80-06
*0esign Pressure safety margin of 21
"This testis owned by Quality Metal fabricators, who has given permission to share resting.
Certificate of Independence:
Locke Bowden, P.E. does not have. nor will acquire a financial Interest in any company manufacturing ar distributing products
under this evaluation.
Locke Bowden, P.E. Is not owned, operated, or controlled by any company, manufacturer, or distributing` underi*/r)
report..i`•a`�-F' B
' �4 r_ • � �lll
`I 4970A
r U y • +
of
',�O • • FL4Rk'':. ci
Integrity Metals Min. 26GA 5V Crimp Roof Panel installation Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6 0 ed.. see Chart 1507.1.1
2. Minimum slope to be compliant with Florida Building Code 2017 a ed., and per with Manufacturer's installation reference.
3. Products are compliant with State of Florida product approval per Rule 61G20-3. Compliance Method: 1-i.7
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
S. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
241
E
3/8"
PROFILE
ZONE 2 GABLE ROOF
FADGE
ZONE t
ZONE 3 EAVt
FASTENER PATTERN @ 12" O.C.
a . 2OW 2 -- 21"t 3 k
a
a
a
RIDGE
ZONE ].
EAVE