Loading...
HomeMy WebLinkAboutGulfcoast Cover sheet3/24/2020 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsQFc5K%2fTrZeCSHgw99R5wgrf90EeqvkzBZ4cWkSTfwnA%3d%3d 1/5 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL11651-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Gulf Coast Supply & Manufacturing, LLC. Address/Phone/Email 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352) 498-0778 info@gulfcoastsupply.com Authorized Signature Eng David info@gulfcoastsupply.com Technical Representative David Eng Address/Phone/Email 14429 SW 2nd Pl Ste G30 Newberry, FL 32669 (352) 498-0778 info@gulfcoastsupply.com Quality Assurance Representative David Eng Address/Phone/Email 14429 SW 2nd Pl Ste G30 Newberry, FL 32669 (352) 498-0778 david.eng@gulfcoastsupply.com Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Daniel S. Kuhn Florida License PE-75519 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL11651_R3_COI_Cert of Independence_2017-10-09.pdf Referenced Standard and Year (of Standard)Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 580 2006 3/24/2020 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsQFc5K%2fTrZeCSHgw99R5wgrf90EeqvkzBZ4cWkSTfwnA%3d%3d 2/5 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/12/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products Go to Page Page 1 / 2 FL #Model, Number or Name Description 11651.1 0.032" Aluminum 5V Crimp Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -108.5 psf @ 12" o.c. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_1_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_1_R3_0325vCrimp_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.2 0.032" Aluminum Gulf Lok Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf @ 5 3/16" o.c. fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_2_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_2_R3_032GulfLok_16_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.3 1" 24ga. Gulf Snap 1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--131.0PS Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_3_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_3_R3_1_24GulfSnap_17_15- 32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes 11651.4 1" 24ga. VersaLoc 1" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5PSF Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_4_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_4_R3_24VersaLoc SR_16.5_15- 32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes 11651.5 1" VersaLoc .032" Aluminum 1" VersaLoc min .032" Aluminum over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-101.0PSF Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6" o.c. Installation Instructions FL11651_R3_II_FL11651_5_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports 3/24/2020 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsQFc5K%2fTrZeCSHgw99R5wgrf90EeqvkzBZ4cWkSTfwnA%3d%3d 3/5 clip spacing. Install per manufacturers details. For use in HVHZ Zones. FL11651_R3_AE_FL11651_5_R3_1in_032VersaLoc SR_16_15- 32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes 11651.6 1.5" 24ga. Gulf Snap 1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per manufacturers detals. For use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_6_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_6_R3_1.5_24GulfSnap_16_15- 32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes 11651.7 1.5" 24ga. VersaLoc 1.5" VersaLoc min 24ga. 16" wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_7_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_7_R3_1.5_24VersaLoc_16_15- 32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes 11651.8 2" 24ga. MegaLoc Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_8_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_8_R3_24VersaLoc_18_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.9 24 Ga. Gulf Lok Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-96.7PSF Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76 psf @ 5-1/8" o.c. fastener spacing. -121.75 psf @ 5-1/8" fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_9_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_9_R3_24GulfLok_16_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.10 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5PSF Other: -93.5 psf @ 18" o.c. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_10_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_10_R3_24GulfSeam_16_1x4_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.11 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_11_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_11_R3_24GulfSeam_18_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.12 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Installation Instructions FL11651_R3_II_FL11651_12_R3_Metal_Roof_Panel_Detail- 3/24/2020 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsQFc5K%2fTrZeCSHgw99R5wgrf90EeqvkzBZ4cWkSTfwnA%3d%3d 4/5 Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5PSF Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_12_R3_265vCrimp_15- 32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes 11651.13 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.PSF Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @ 16" o.c. fastener pattern. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_13_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_13_R3_265vCrimp_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.14 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5PSF Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_14_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_14_R3_265vCrimp_1x4_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.15 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161.0PSF Other: -63.5 psf @ 5 3/16" o.c. fastener spacing. -121.75 psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_15_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_15_R3_26GulfLok_16_15- 32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes 11651.16 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5PSF Other: -63.5 psf @ 5 3/16" o.c. fastener spacing. -121.75 psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_16_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_16_R3_26GulfLok_16_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.17 26 Ga. GulfPBR Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Other: -59.25 psf @ 24" o.c. fastener pattern. -154.75 psf @ 12" o.c. fastener pattern. Install per manufacturer details. Not for use in HVHZ Installation Instructions FL11651_R3_II_FL11651_17_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_17_R3_26GulfPBR_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.18 26 Ga. GulfPBR Min 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7PSF Other: -100.5 psf @ 24" o.c. fastener spacing. -151.75 psf @ 12" fastener spacing. Install per manufacturer's details. For use in HVHZ Zones Installation Instructions FL11651_R3_II_FL11651_18_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_18_R3_26GulfPBR_1x4_15- 32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes 11651.19 26 Ga. GulfPBR Min 26 Ga. GulfPBR over 15/32" Plywood 3/24/2020 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsQFc5K%2fTrZeCSHgw99R5wgrf90EeqvkzBZ4cWkSTfwnA%3d%3d 5/5 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Other: -60.5 psf @ 24" o.c. fastener spacing. -154.75 psf @ 12" o.c. fastener spacing. Install per manufacturer's details. For use in HVHZ Zones. Installation Instructions FL11651_R3_II_FL11651_19_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_19_R3_26GulfPBR_15- 32Plywood_HVHZ-signed.pdf Created by Independent Third Party: Yes 11651.20 26 Ga. GulfPBR Min 26 Ga. GulfPBR over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7PSF Other: -94.25 psf @ 24" o.c. fastener spacing. -151.75 psf @ 12" fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones Installation Instructions FL11651_R3_II_FL11651_20_R3_Metal_Roof_Panel_Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651_R3_AE_FL11651_20_R3_26GulfPBR_1x4_15- 32Plywood_NonHVHZ-signed.pdf Created by Independent Third Party: Yes Go to Page Page 1 / 2 Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: