HomeMy WebLinkAboutGulfcoast Cover sheet3/24/2020 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsQFc5K%2fTrZeCSHgw99R5wgrf90EeqvkzBZ4cWkSTfwnA%3d%3d 1/5
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL11651-R3
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Gulf Coast Supply & Manufacturing, LLC.
Address/Phone/Email 4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-0778
info@gulfcoastsupply.com
Authorized Signature Eng David
info@gulfcoastsupply.com
Technical Representative David Eng
Address/Phone/Email 14429 SW 2nd Pl
Ste G30
Newberry, FL 32669
(352) 498-0778
info@gulfcoastsupply.com
Quality Assurance Representative David Eng
Address/Phone/Email 14429 SW 2nd Pl
Ste G30
Newberry, FL 32669
(352) 498-0778
david.eng@gulfcoastsupply.com
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Daniel S. Kuhn
Florida License PE-75519
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL11651_R3_COI_Cert of Independence_2017-10-09.pdf
Referenced Standard and Year (of Standard)Standard Year
FM 4471 1992
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL 1897 2012
UL 580 2006
3/24/2020 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsQFc5K%2fTrZeCSHgw99R5wgrf90EeqvkzBZ4cWkSTfwnA%3d%3d 2/5
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/10/2017
Date Validated 10/12/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/12/2017
Summary of Products
Go to Page Page 1 / 2
FL #Model, Number or Name Description
11651.1 0.032" Aluminum 5V Crimp Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32"
Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -108.5 psf @ 12" o.c. Install per manufacturers details.
Not for use in HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_1_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_1_R3_0325vCrimp_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.2 0.032" Aluminum Gulf Lok Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32"
Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.0PSF
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf
@ 5 3/16" o.c. fastener spacing. Install per manufacturers
details. Not for use in HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_2_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_2_R3_032GulfLok_16_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.3 1" 24ga. Gulf Snap 1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--131.0PS
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in HVHZ
Zones.
Installation Instructions
FL11651_R3_II_FL11651_3_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_3_R3_1_24GulfSnap_17_15-
32Plywood_HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.4 1" 24ga. VersaLoc 1" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-138.5PSF
Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in HVHZ
Zones.
Installation Instructions
FL11651_R3_II_FL11651_4_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_4_R3_24VersaLoc SR_16.5_15-
32Plywood_HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.5 1" VersaLoc .032" Aluminum 1" VersaLoc min .032" Aluminum over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-101.0PSF
Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6" o.c.
Installation Instructions
FL11651_R3_II_FL11651_5_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
3/24/2020 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsQFc5K%2fTrZeCSHgw99R5wgrf90EeqvkzBZ4cWkSTfwnA%3d%3d 3/5
clip spacing. Install per manufacturers details. For use in HVHZ
Zones.
FL11651_R3_AE_FL11651_5_R3_1in_032VersaLoc SR_16_15-
32Plywood_HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.6 1.5" 24ga. Gulf Snap 1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.0PSF
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c.
clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per
manufacturers detals. For use in HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_6_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_6_R3_1.5_24GulfSnap_16_15-
32Plywood_HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.7 1.5" 24ga. VersaLoc 1.5" VersaLoc min 24ga. 16" wide Roof Panel over 15/32"
Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.5PSF
Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_7_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_7_R3_1.5_24VersaLoc_16_15-
32Plywood_HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.8 2" 24ga. MegaLoc Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32"
Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c.
clip spacing. Install per manufacturers details. Not for use in
HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_8_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_8_R3_24VersaLoc_18_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.9 24 Ga. Gulf Lok Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76 psf
@ 5-1/8" o.c. fastener spacing. -121.75 psf @ 5-1/8" fastener
spacing. -161 psf @ 5-1/8" fastener spacing. Install per
manufacturers details. Not for use in HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_9_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_9_R3_24GulfLok_16_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.10 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood
Purlins over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-93.5PSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers details.
Not for use in HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_10_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_10_R3_24GulfSeam_16_1x4_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.11 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel
over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for use
in HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_11_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_11_R3_24GulfSeam_18_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.12 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Installation Instructions
FL11651_R3_II_FL11651_12_R3_Metal_Roof_Panel_Detail-
3/24/2020 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsQFc5K%2fTrZeCSHgw99R5wgrf90EeqvkzBZ4cWkSTfwnA%3d%3d 4/5
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @
6" o.c. fastener spacing. Install per manufacturers details. For
use in HVHZ Zones.
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_12_R3_265vCrimp_15-
32Plywood_HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.13 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @
16" o.c. fastener pattern. Install per manufacturers details. Not
for use in HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_13_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_13_R3_265vCrimp_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.14 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over
15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @
6" o.c. fastener spacing. Install per manufacturers details. For
use in HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_14_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_14_R3_265vCrimp_1x4_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.15 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-161.0PSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing. -121.75 psf
@ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener spacing.
Install per manufacturers details. For use in HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_15_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_15_R3_26GulfLok_16_15-
32Plywood_HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.16 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-63.5PSF
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing. -121.75 psf
@ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener
spacing. Install per manufacturers details. Not for use in HVHZ
Zones.
Installation Instructions
FL11651_R3_II_FL11651_16_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_16_R3_26GulfLok_16_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.17 26 Ga. GulfPBR Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-154.7PSF
Other: -59.25 psf @ 24" o.c. fastener pattern. -154.75 psf @
12" o.c. fastener pattern. Install per manufacturer details. Not
for use in HVHZ
Installation Instructions
FL11651_R3_II_FL11651_17_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_17_R3_26GulfPBR_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.18 26 Ga. GulfPBR Min 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over
15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-151.7PSF
Other: -100.5 psf @ 24" o.c. fastener spacing. -151.75 psf @
12" fastener spacing. Install per manufacturer's details. For use
in HVHZ Zones
Installation Instructions
FL11651_R3_II_FL11651_18_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_18_R3_26GulfPBR_1x4_15-
32Plywood_HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.19 26 Ga. GulfPBR Min 26 Ga. GulfPBR over 15/32" Plywood
3/24/2020 Florida Building Code Online
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsQFc5K%2fTrZeCSHgw99R5wgrf90EeqvkzBZ4cWkSTfwnA%3d%3d 5/5
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-154.7PSF
Other: -60.5 psf @ 24" o.c. fastener spacing. -154.75 psf @
12" o.c. fastener spacing. Install per manufacturer's details. For
use in HVHZ Zones.
Installation Instructions
FL11651_R3_II_FL11651_19_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_19_R3_26GulfPBR_15-
32Plywood_HVHZ-signed.pdf
Created by Independent Third Party: Yes
11651.20 26 Ga. GulfPBR Min 26 Ga. GulfPBR over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-151.7PSF
Other: -94.25 psf @ 24" o.c. fastener spacing. -151.75 psf @
12" fastener spacing. Install per manufacturer's details. Not for
use in HVHZ Zones
Installation Instructions
FL11651_R3_II_FL11651_20_R3_Metal_Roof_Panel_Detail-
signed.pdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651_R3_AE_FL11651_20_R3_26GulfPBR_1x4_15-
32Plywood_NonHVHZ-signed.pdf
Created by Independent Third Party: Yes
Go to Page Page 1 / 2
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts: