Loading...
HomeMy WebLinkAboutProduct Approval K � �.'3 r� "t. K'0 ,.�1���'�•rJSrrr.��� �S .moi 1 i „ F�� r r'i a!' :i,-,.mss'n . ''��S,�x� `5���'�.r�a i�_"r�`3`a�i�`.c iE' ��.,,�l.�S-i�Yaa._.Y�ivf�f �4 .s����� 1 c'x'k¢.�u'.ti-'•k,�i ��� r ,.d � �+ �''4'•.%,�;��L c;7� ��` 4�a P�'f° ?* �Ra 4 &ttf ��` .w� ey'7 SCIS Home Log In ; User Registration Hot Topic Submit Surcharge Stats Facts Publications Contact Us BQS Site Map Links Search I db a r f`j q�j;��Product Approval ` "USER:Public User Product Approval Menu>Product or Application Search>ADy ation UsC>Application Detail FL# FL30304 RFC 96' FIV .Application Type New Code Version 2017 Application Status Approved P X41® erfiittiA St LUe a Couh y en1 ` Comments Archived Product Manufacturer Drexel Metals InFILECORY Address/Phone/Email 204 Railroad Drive Ivyland,PA 18974 (502)303-1511 (502)3 3-15LImet.com 0 Py Authorized Signature ]shun Shumate -� l/�t�33 jshumate@drexmet.com Technical Representative fEWE® FOR Address/Phone/Email CODE COMPLIANCE Quality Assurance Representative ST. L U C I E COUNTY Address/Phone/Email B O C C Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R.Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity Architectural Testing,Inc.,an Intertek Company Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden P.E. v Validation Checklist-Hardcopy Received Certificate of Independence FL30304 RO COI EIRX19002 2017 FBC Evaluation Rgoort NonHVHZ Metal Roofing 092719.pdf Referenced Standard and Year(of Standard) Standard Year ASTM B 117 2016 ASTM G 155 2005 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 560 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/15/2019 Date Validated 08/28/2019 Date Pending FBC Approval 08/29/2019 Date Approved 10/15/2019 SummarV of Products FL# Model,Number or Name Description 30304.1 HVHZ Metal Roofing Non-structural metal roof panels for use Inside the HVHZ Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL36304 RO n DRX19003 2017 FBG Evaluation Ref ant HVHZ Approved for use outside HVHZ:No Metal Roofing 082719.pdf Impact Resistant.N/A Verified By:Zachary R.Priest PE-74021 Design Pressure: +0/-161 Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL30304 RO AE DRX19003 201 FB_C Evaluation Report HV Metal Roofing 082719.pd Created by independent Third Party:Yes 30304.2 non-HVHZ Metal Roofing Non-structural metal roof panels for use outside the HVHZ Limits of Use Installation Instructions Approved for use In HVHZ:No FL30304 RO II DRX19002 2017 FBG Evaluation Rgpp Approved for use outside HVHZ:Yes Non HVHZ Metal Roofing OB2719.odf Impact Resistant:N/A Verified By: Zachary R.Priest PE-74021 Design Pressure: +A/-161 Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL30304 RO AE DRX190Q2.2017 FBC Evaluation Re= NonHVHZ Metal Roofing OB2719.Ddf Created by Independent Third Party:Yes Contact Us::2601 Blair Stone Road.Tallahassee Fl.32399 Fhone:-8So-48 -1824 The State of Florida is an AA/EEO employer. itate of Florida.::PriVBtY statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by tradltlonal mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address i1 they have one.The emalts provided may be used for official communicatlon with the licensee.However emall addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click lig-. Product ApprovalAemptst M®EH M Credit Card . Safe • • f ; Certificate of Authorization No.29824 17520 Edinburgh Dr CREEK Tampa,FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,67"EDITION(2017) Manufacturer: DREXEL METALS,INC. Issued August 27, 2019 1234 Gardiner Lane Louisville, KY 40213 (502)716-7143 www.drexmet.com Manufacturing: Port St.Lucie,FL Quality Assurance: Architectural Testing,Inc.(QUA1844) SCOPE Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Enti Report No. Standard Year Architectural Testing,Inc(an Intertek Company)(TST1527) F8542.01-450-44 UL 580 2006 UL 1897 2012 Architectural Testing,Inc(an Intertek Company)(TST1527) G1899.01-450-18 UL 580 2006 UL 1897 2012 Architectural Testing,Inc(an Intekek Company)(TST1527) F0755.01-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) F9156.01-450.18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) F9156.02-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) 0412-1012-06 TAS 125 2003 Architectural Testing(TST1558) C6413.02-450-18 TAS 125 2003 Architectural Testing(TST1558) D6207-01-450-18 TAS 125 2003 Architectural Testing(TST1558) C6413.01-450-18 TAS 125 2003 Force Engineering&Testing(TST5328) 72-019TOT-07 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 72-0314T-06A-C UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 72-0313T-06A-C UL 580 2006 UL 1897 2012 Hurricane Test Laboratory(TST1527) 0412-1203.07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0412-1017-05 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0412.01012-06 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0412-0305-07 TAS 125 2003 DRX19002 FL30304 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Motal Roofing TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION 1.5" 1 Profile: 1.5-inch mechanical seam;Max.20-inch coverage Mechanical Description: Non-structural,min. 180°mechanical lock standing seam roof panel; Lock Material: Min.16o�ASTM 8370 copper,Shall conform with FBC Section 150_7.4.3 Min.24 ga. Fiuropon®coated ASTM A792 AZ50,or ASTM A653 G90 steel(Fy min.50 ksl); Shall conform with FBC Section_1507.4.3 Min.0,032-inch Fluropon®coated ASTM B209 aluminum(Fy=min.24 ksi); Shall conform with FBC Section 1507.4.3 16..-20,. 1.5"Nall Strip Profile: 1.5-inch snap lock seam;Max 15.5-inch coverage Description: Non-structural,snap lock standing seam roof panel;slotted nail strip; _ Material: Min.24 ga.Fluropon®coated ASTM A792 A7_50,or ASTM A653 G90 steel(Fy= min.50 ksi); Shall conform with FBC Section 1507.4.3 15 1/2 1c 4: PBR and Profile: _ '/-inch rib; Max.36-inch coverage Econ Line Descriptionuctural,through fastened roof anel PBR - : Non-structural,— — Material: Min.26ga.Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90(Fy=min.40 ksi); Shall conform with FBC Section 1507.4.3 36 Cr DRX19002 FL30304 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,I . Metal Roofing TE RVICEs,LLC Econo Line V Profile: 1-inch snap look seam;Max.16-Inch coverage _ Clipless Description: Non-structural,snap lock standing seam roof panel_slotted nail strip;IShall Material: Min.26 ga.Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90min.40 ksi); Shall conform with FBC Section 1507.4.3 Min.0.032-inch Fluropon®coated ASTM B209 aluminum(Fy=min.2 conform with FBC Section 1507.4.3 T 1" Striations Optional (Flat Shawn) Jacksonville Profile: -Inc snap0c seam, Beach Series Description: Non-sVuetural,snap lock standing seam roof panel;slotted nail strip; 1.5"Ciipless Material: Min.24 ga.Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90 steel(Fy= min.50 ksi); Shall conform with FBC Section 1507.4.3 Min.0.032-Inch Fluropon@ coated ASTM B209 aluminum(Fy=min.21 ksi); Shall conform'with FBC Section 1507.4.3 15"-19"Coverage T_ - I _1 (Opfipnel5ta`lc�ung Ri�cAtndaN�e} Miami Series Profile: _ 1.75-inch snap lock seam;Max. 18-inch coverage 1.75 Snap Description: Non-structural,snap lock standing seam roof panel; Lock Material: Min.24 ga.Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90 steel(Fy= min.50 ksi); Shall conform with FBC Section 1507.4.3 _ Min.0.032-inch Fluropon@ coated ASTM 8209 aluminum(Fy=min.24 ksi); Shall conform with FBC Section 1507.4.3 Palm Beach Profile; 1.5-inch mechanical seam;Max.20-inch coverage Series 1.5 Description: Non-structural,min.90°mechanical lock standing seam raofpanel;_�� Mechanical Material: i Min.24 ga.Fluropon@ coated ASTM A792 AZ50,or ASTM A653 G90 steel(Fy= Seam _min.50 ksi); Shall conform with FBC Section 1507.4.3 ^Min.0.032 inch Fluropon@ coated ASTM 8209 aluminum(Fy=min.24 ksi); Shall conform with FBC Section 1507.4.3 �..... ---__...._ . 12" - 20" Widths Available 1`= Slilfening Fibs Optional ;F131 rs."Giip Relief Shtnvni DRX19002 FL30304 Page 3 of 5 This evaluation report Is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,installation,recommended use,or other product attributes that are hot specifically addressed herein. a• CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC Key West Profile: %ranch ribs; Max.24-inch coverage Series 5-V Description: Non-structural,through fastened roof panel Crimp Material: Min.26 ga.Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90 steel(Fy= min.50 ksi); Shall conform with FBC Section 1507.4.3 '24"Max n v.j Net Gavera{jb r r nl r Stuart Line Profile: 1-inch snap lock seam;Max.16-Inch coverage _ Series 1"Nail Description:_ _Non-structural,snap lock standing seam roof panel;slotted nail strip; ~_ Strip Material:u� Min.24 ga.Fluropon®coated ASTM A792 AZ50,or ASTM.A653 G90 steel(Fy min.50 ksi); Shall conform with FBC Section 1507.4.3��r .i.. DRX19002 FL30304 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall!notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not speciflcally addressed herein. CRDEEK DREXEL METALS,INC. 1 Metal Roofing TECHNICAL SERVICES,U.0 LiMiTATIONS I 1. Fire classification Is not within the scope of this evaluation. 2. This report is not for use in the HVHZ. 3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2. 5. Reroofing shall be In accordance with FBC Section 1511. 6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,6c'Edition(2017)as evidenced In the referenced documents submitted by the named manufacturer. ,`,11111`I 111 ft�,I O 4 a 'G�PY'•p-•p'9� 2019.08.27 F . • No 74021 *: 16:04:42 -04'00' •'-:13 /STATE OF ;�4J` .00'i;<% '•. 0 AN N Zachary R.Priest,P.E. ONA,1 Organi Floridaegi Notl n No.E964740211 CERTIFICATION OF INDEPENDENCE- CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributIng products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest,P.E.does not have, nor will,acquire, a financial Interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A—Installation(1 pages) 2) APPENDIX B—Approved Roof Systems(5 pages) 3) APPENDIX C—Design Wind Loads(4 pages) DRX19002 FL30304 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duretion for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX A INSTAI-I-ATION Note-Refer to the APPROVE!)RooF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specked in this report the following installation details shall be met for the named products: Component 'Product.. Installation Detall #9-15 HWH wood screw with sealing washer #10 HWH wood screw with sealing washer #10 PH wood screw #10-11 Eclipse Head Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion wood screw with sealing resistant in accordance with FBC section 1507.4.4. Fasteners washer #10-13 PH wood screw #12-41 PH wood screw #14 WoodZACO HWH screws #14-13 TH wood screw #14 PH self-drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be corrosion resistant in accordance with FBC section 1507.4.4. 1500SC 1.54nch Sliding' 26 ga.top with 22 ga.base galvanized steel,in-seam clip Clip 0.050-inch galvanized steel In-seam clip 43 Miami Series 1.75 Snap 1 .875 - Lock .87CJ .Lock Clip Lj Clips �---3.5'0—�--I —J 2.08 L 24 ga.galvanized steel in-seam clips Palm Beach Series 1.5 Mechanical Seam Clip I Bostik Chem Calk 915 Sealants Bostik 70-05A Shall be applied In%-Inch wide continuous beads along the seam DRX19002 FL30304 Page 1 of 1 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notity CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. f r CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX B APPROVED ROOF SYSTEMS The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure(MDA)was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s)below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system. 5. The panel thicknesses stated in the tables below are the minimum thicknesses required. 6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga(F,,=min.33 ksi)Wide Rib Deck(Type WR) conforming to ANSYSDI-RD1.0 iii FBC. 7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/324nch thick APA Span-Rated plywood sheathing at maximum 24-inch span. Roof System Numbers and Definitions 1.5ML-W 1.5 Mechanical tock over Wood Deck(New or Existin i 1.5NS-W# 1.5 Nail Strip over WoodDeck(New or Existing) PBR-W# PBR or Econo Line PBR over Wood Deck New or Existing) ELiC-W# Econo Line 1"Cli less over Wood Deck New or Existing) J1.5C-W# Johnsonville Beach Series 1.5'Cli less over Wood Deck New or Existing) M1.75-W# Miami Series 1.75 Snap Lock over Wood Deck New or Existing) P1.5M-W# Palm Beach Series 1.5 Mechanical Seam over Wood Deck New or Existing) K5VC W# Ke West Series 5-V Crimp over Wood Deck New or Existing) SINS-W# Stuart Line Series 1"Nail Strip over Wood Deck New or Existing) Approved Systems for 1.5 Mechanical Lock over Wood_Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP No. (pso j Min.15132 OPTIONAL 24 ga.1.5 Mechanical Lock 1600SC 1.5-Inch Sliding Clip with j 1.5ML-W 1 CDX plywood Versashield Solo As required per FBC Max.16-inch wide two(2)#12-11 PH wood screws -69.75 spaced 244nch o.c. } Mtn.15132 OPTIONAL 24 ga.1.5 Mechanical Lock 1500SC 1.54nch Sliding Clip with 1.5ML--W2 CDX plywood Versashleld Solo As required per FBC Max. Winch wide �(2)#12-11 PH wood screws -123.5 spaced 64nch o.c. DRX19002 FL30304 Page 1 of 5 This evaluation report Is provided for State of Florida product approval under Rule 616203. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i METALS,INC. ACREEK DftEXEL Metall Roofing TECHNICAL SERVICES,LLC APPENDIX B Appi roved Systems for 1.5 Nail Strip over Wood Deck New or Existing) System Deck Fire Barrier Undertayment Roof Panel Panel Attachment MDP No: (Psf) Min.15/32 OPTIONAL 24 ga.1.5 Nail Strip One(1)#12-11 PH wood screws -78.5 1.SNSafV1 CDX plywood Versashield Solo As required per FBC Max.15.54nch wide spaced 11-inch o.c.along the nail strip i i Approved Systems for P13R or Econo Line PBR over Wood Deck(New or Existing) System Deck Fire Barrier Underlayment Roof Panel •Panel Attachment MDP No. (Pso i ! One(1)#9-15 HWH wood screw with sealing li washer placed 1.5-inches from each side of Min.15/32 OPTIONAL 26 ga.PBR panel lap and one(1)#9-15 HWH wood screw PBR-W1 CDX plywood Versashield Solo As required per FBC Max 36 inch wide and sealing washer placed 1.5-inches to one -76.75 side of the each Intermediate rib(5 fasteners pattern); Fastener rows spa o.c. Approved Systems for Econo Line 1"Clipless over Wood Dock New or Existing) System. Fire Barrier/ MDP No. Deck Insulation Underlayment Roof Panel Panel Attachment (Psf) ELIC-W1 Min.15132 OPTIONAL As required per FBC 26 ga,Econo Line 1"Cliplass One(1)#10 PH wood screws -71 CDX plywood Versashield Solo Max.164nch coverage spaced 64nch o.c.along the nail strip One(1)#10 PH wood screws Min. OPTIONAL .032 AI Econo Line l"Clipless spaced 64nch o.c.along the nail strip; 78.5 ELICW2 CDX plywood Versashieid Solo required per FBC Max 164nch coverage Bostik 70-05A applied to both sides of the male rib prior to seam engagement i E - DRX19002 FL30304 Page 2 of 5 This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other 1 product attributes that are not specifically addressed herein. I _ GREEK DREXEL METALS,INC. Metal Roofing I TECHNICAL SERVICES,LLC APPENDIX B Approved Systems for Jacksonville Beach Series 1.5"Clipless over Wood Deck(New or Existing) System Fire Barrier/ MDP Deck Underlayment Roof Panel Panel Attachment No. Insulation (pso OPTIONAL 032 AI Jacksonville Beach One(1)#10 PH wood screws Min.15132 spaced 6-inch o.c.along the nail strip; J1.5C-W1 CDX plywood Approved fire barrier As required per FBG Series 1.5"Clipless g k 70-05A applied to both sides of the male rib 76.75 or insulation Max 19 inch coverage prior to seam engagement; OPTIONAL 24 ga.Jacksonville Beach One(1)#10 PH wood screws Min.15/32 spaced 6-inch o.c.along the nail strip; J1.5C W2 CDX plywood Approved fire barrier As required per FBC. Series 1.5"Clipless Bostlk 70-05A applied to both sides of the male rib -97'25 or insulation Max 19-inch coverage prior to seam engagement; OPTIONAL .032 At Jacksonville Beach One(1)#10 PH wood screws J1.5Ca1V3 Min.15/32 Approved s requiper fire barrier As FBC Series 1.5"Clipless spaced 3-inch o.c.along the nail strip; -108.5 CDX plywood or insulation Max.19 inch coverage prior 70-05A applied to both sides of the male rib prior to seam engagement; OPTIONAL 24 ga.Jacksonville Beach One(1)#10 PH wood screws Min.15132 spaced 3-inch o.c.along the nail strip; J1.5C-W4 CDX plywood Approved fire barrier As required per FBC Series 1.5"Clipless Bostik 70-05A applied to both sides of the male rib -161 or insulation Max 19-inch coverage prior to seam engagement; Approved Systems for Miami Series 1.75.Snap Lock over Wood Deck(New or Existing) System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP No. Insulation (psf) Min.15132 OPTIONAL .032 AI Miami Series Miami Series 1.75 Snap Lock Clip with M1.75-W7 Approved fire barrier As required per FBC 1.75 Snap Lock two(2)#10 PH wood screws -110.5 CDX plywood or insulation Max 14-inch coverage spaced 12-inch o.c. Min.15132 OPTIONAL 24 ga.Miami Series Miami Series 1.75 Snap Lock Clip with M1'75-W2 CDX plywood Approved fire barrier As required per FBC 1.75 Snap Lock two(2)#10 PH wood screws -114.25 or insulation Max 18-inch coverage spaced 16-inch o.c. Min.15!32 OPTIONAL .032 At Miami Series Miami Series 1.75 Snap Lock Clip with M1.75-W3 Approved fire barrier As required per FBC 1.75 Snap Lock two(2)#10 PH wood screws 414.25 CDX plywood or insulation Max.14-Inch coverage spaced 64nch o.c. Min.15132 OPTIONAL 24 ga.Miami Series Miami Series 1.75 Snap Lock Gip with M1.75-W4 CDX plywood Approved fire barrier As required per FBC 1.75 Snap Lock two(2)#10 PH wood screws -156.75 or insulation Max 18-inch coverage spaced 8-inch o.c. DRX19002 FL30304 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. f �I i c CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES, LLC APPENDIX B Approved Systems for Palm Beach Series 1.5 Mechanical Seam over Wood Deck(New or Existing) System, Deck Fire Barrier Underlayment Roof Panel Panel Attachment s . :032 AI Palm Beach Series palm Beach Series 1.5 Mechanical Seam Clip P1.5M-W1 Min.15!32 OPTIONAL As required per FBC 1.5 Mechanical Seam with two(2)#10 PH wood screws -63.5 CDX plywood Versashield Soto Max.20-inch wide spaced 24-inch o.c. 90'seam 24 ga.Palm Beach Series Palm Beach Series 1.5 Mechanical Seam Up P1 5M W2 Min.15/32 OPTIONAL As required per FBC 1.5 Mechanical Seam _ with two(2)#10 PH wood screws 413.5 i CDX plywood Versashield Solo Max 20-inch wide spaced 24-inch o.c. 90 seam 24 ga.Palm Beach Series palm Beach Series 1.5 Mechanical Seam Clip PI-SM-W3 . Min.CDX plywood IS/S OPTIONALod Versashield Soto As required per FBC 1.Max.20-Inch wide 5 Mechanical Seam with two(2)#10 PH wood screws 401 90°seam spaced 6 inch o.c. 24 ga.Palm Beach Series Palm Beach Series 1.5 Mechanical Seam Clip P1.5M-W4 Min.15132 OPTIONAL As required per FBC 1.5 Mechanical Seam with two(2)#10 PH wood screws 423.5 CDX plywood Versashield Solo Max 20-inch wide spaced 6-inch o.c, 180,seam .032 Al Palm Beach Series palm Beach Series 1.5 Mechanical Seam Clip Min.15132 OPTIONAL 1.5 Mechanical Seam P1.5M W5 CDX plywood Versashield Solo As required per FBC Max 204nch wide with two(2)#10 PH wood screws -139 spaced 6-inch o.c. 1160°seam Approved S tems for Key West Series 5-V Crimp over Wood Deck New or Existing) SDP ystem Deck Fire Barrier Underleyment Roof Panel Panel Attachment P One(1)#10 HWH wood screw with sealing Min.15/32 OPTIONAL 26 ga.5-V-Crimp washer placed through the apex of the inside KSVC-W 1 CDX plywood Versashield Solo As required per FBC Max.24-inch wide rib at the panel lap and through the center rib -78.5 I of the panel(124nch o.c.across the panel); Fastener rows spaced 16-inch o.c. One(1)#14 WoodZAC®HWH wood screw Min.15132 OPTIONAL 26 ga.5-V Crimp with sealing washer placed through the apex of KSVC-W2 CDX plywood Versashield Solo As required per FBC Max 24-Inch wide the inside rib at the panel lap and through the -106.75 center rib of the panel(124nch o.c.across the panel);Fastener rows spaced 8-Inch o.c. DRX19002 FL30304 Page 4 of 5 This evaluation report Is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i CREEK DREXEL METALS,INC. � Metal Roofing TECHNICAL SERVICES,LLC APPENDIX B Approved Systems for Stuart Line Series 1"Nail Strip over Wood Deck(New or Existing) System Fire Barrier! MDA No. ick Insulation Underfayment Roof Panel Panel Attachment (Psf) OPTIONAL 24 ga.Stuart Line Series One(1)#10 PM wood screws Min.15132 spaced 12-inch o.c.along the nail strip; S1NS-W1 CDX plywood Approved fire barrier As required per FBC 1"Nail Strip X1.25 or insulation Max 164nch coverage $ostik Chem-Calk 915 applied along the fasteners prior to seam engagement; OPTIONAL 24 ga.Stuart Line Series One(1)#10 PH wood screws Min.15132 spaced 6-inch o.c.along the nail strip; S1 NS W2 plywood Approved fire barrier As required per FBC 1"Nail Strip -136.75 CDX 1 or insulation Max 16-inch coverage Bo58k Chem-Calk 915 applied to top of male rib on fastening side prior to seam engagement; i DRX19002 FL30304 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20.3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i METALS,INC. CREEK - DREXEL Metal Roofing TECHNICAL SERVICES,LLC APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-10 under the following provisions: 1. For Hip roofs between 2:12 and 5.6:12,Zone 3 shall be treated as Zone 2. Z Wind speeds for risk category I,ll,III,and IV buildings shall be as defined in Section 1609 of the FBC. 3. Exposure B.C,and D shall be as defined in section 1609 of the FBC. 4. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12 5. Ali calculations are based on an effective wind area of 10-ftz or less. 6. Topographic factors such as escarpments or hills have been excluded from the analysis 7. Overhangs have been excluded from the analysis. 8. Wind directionality factor,Kd=0.85 9. V„R is shown in the tables below.Design wind loads are calculated using Ve,d=V&40.6 per 1609.3.1. 10. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional i 11. Zones 1,2,and 3 shall be defined as shown below. Dimension"a"shall be 10%of the least horizontal dimension or(0.4 x Mean Roof Height),whichever is smaller,but not less than either 4%of the least horizontal dimension or 3ft Gable Hip 3 2 3 3 2 3 a 3 2 a } 2 1 2 2 1 2 2 1 2 2 1 2 3 2 1313 2 3 a 2 a Ial is a� al Ia) la ' I 1 DRX19002 FL30304 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 611G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i CREEK DREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIX C 4414 Roofs in E osure 6 Roof slo between 2:12 and 6.1:12 . Bulling Mean: Basic Wind S .ed mph) ` ! Type Zane Roof -190120 130 140. 150 160;` 170: 180 200 Height it 20 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 32.0 -35.6 -39.5 25 -14.2 -16.7 -19.3 -22.2 25.3 28.5 -32.0 -35.6 -39.5 I 1 30 -14.2 -16.7 -19.3 -22.2 -25.3 -28.5 32.0 -35.6 39.5 40 -15A -18.1 -21.0 -24.1 -27.4 X1.0 -34.7 -38.7 -42.9 50 -16.5 -19.3 -22.4 -25.7 -29.2 -33.0 -37.0 -41.2 -45.7 60 -17.3 -20.3 -23.5 -27.0 30.7 -34.6 -38.8 -43.3 -47.9 20 -24.7 -29.0 -33.7 -38.7 44.0 -49.7 -55.7 -62.0. -68.7 25 -24.7 -29.0 -33.7 -38.7 -04.0 -49.7 -55.7 -62.0 -68.7 Enclosed 2 30 -24.7 -29.0 -33.7 -38.7 44.0 -49.7 -55.7 -62.0 -68.7 40 -26.9 -31.5 -36.6 -42.0 47.8 -53.9 -60.4 -67.3 -74.6 50 -28.6 1 -33.6 39.0 -44.7 -50.9 -57.5 -64A -71.8 -79.5 60 30.0 35,3 40.9 -46.9 33A -60.3 -67.6 -75.3 -83.5 20 36.6 -42.9 49.8 -57.2 35.0 -73.4 -82.3 -91.7 -101.6 25 36.6 -42.9 149.8 -57.2 -65.0 -73.4 -82.3 -91.7 -101.6 3 30 -36.6 142.9 49.8 -57.2 -65.0 -73.4 32.3 -91.7 -101.6 40 -39.7 -46.6 -54.1 -62,1 -70.6 -79.7 -89.4 -99.6 -110.3 50 42.3 -49.7 -57.6 36.2 -75.3 -85.0 -95.3 -106.1 -117.6 60 -44.4 . -52.1 -60.5 -69.4 79,0 -89.2 -100.0 -111.4 -123A 20 -19.1 -22.4 -26.0 -29.8 -33.9 -38.3 .42.9 -47.8 33.0 25 -19.1 -22.4 -26.0 -29.8 33.9 -38.3 42.9 -47.8 33.0 1 30 -19.1 -22.4 -26,0 -29.8 -33.9 38.3 42.9 -47.8 -53.0 40 -20.7 -24.3 -28.2 -32.4 -36.8 -41.6 46.6 -51.9 57.6 50 -22.1 -25.9 -30.1 -34.5 -39.3 44.3 49.7 -55A -61.3 60 -23.2 -27.2 -31.5 -36.2 -41.2 -46.5 -52.1 -58.1 -64.4 20 -29.6 -34.8 40.3 46.3 -52.6 -59.4 56.6 -74.2 32.3 i 25 -29.6 -34.8 140.3 46.3 -52.6 -59.4 -66.6 -74.2 -82.3 Il Partially 2 30 -29.6 -34.8 40.3 46.3 -52.6 39.4 -66.6 -74.2 -82.3 ! Enclosed 40 32.2 -37.7 43.8 302 57.2 -64.5 -72.3 -80.6 -89.3 r 50 -34.3 -40.2 146.6 -53.5 -60.9 -68.8 -77.1 -85.9 -95.2 k 60 -36.0 142.2 -48.9 -562 -63.9 -722 -80.9 -90.1 -99.9 ! 20 -41.5 -48.7 56.4 -64.8 73.7 -83.2 -93.3 -103.9 -115.2 25 -41.5 -48.7 56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 30 -41.5 -48.7 -56A -64.8 -73.7 -83.2 -93.3 -103.9 A 15.2 3 40 45.0 -52.8 -61.3 -70.3 -80.0 -90.3 -101.3 -112.8 -125.0 50 -48.0 -56.3 -65.3 -75.0 -85.3 -96.3 1 -107.9 -120.3 -133.3 60 50.3 -59.1 -68.5 -78.7 -89.5 -101.0 -113.3 -126.2 -139.8 DRX19002 FL30304 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEK DREXEL METALS, 4 �„ Metal Roofing TECHNICAL SERVICES,LLC APPENDIX C Gable/Hip t2oofs.In Ex osure C Roof slo a between 2:12 and Budding Mean Basic Wind S�' m'h f Zone Roof Type Hei t ft 170 130. 140 150. 164 170. 180 190.. ~200 20 -18.3 -21.4 -24.9 -28.6 -32.5 -36-7 -41.1 -45.8 50.8 25 -19.1 -22.4 -26.0 -29.8 -3.9 -38.3 -42.9 -47.9 53.0 30 -19.9 -23A -27.1 -31.1 -35A -39.9 -44.8 -49.9 55.3 1 40 -21.1 -24.8 -28.7 -33.0 -37.5 -42.4 -47.5 -52.9 58.7 50 -22.1 -26.0 50.1 -34.6 59A -44.4 149.8 -55.5 51.5 60 -22.9 -26.9 51.2 55.9 -40.8 -46.1 -51.6 -57.5 -53.7 20 -31.8 -37.3 143.3 -49.7 -56.6 -63.8 -71.6 -79.8 -88.4 25 -33.2 -39.0 -45.2 51.9 -59.1 -66.7 -74.8 -83.3 -92.3 Enclosed 2 30 -34.6 -40.7 47.2 -54.1 -61.6 -69.5 -77.9 -86.8 -96.2 I 40 -36.8 -43.1 -50.0 . -57.4 -65.4 -73.8 -82.7 -92.2 -102.1 I 50 -38.5 -45.2 -52.4 -60.2 58.5 -77.3 -86.7 -96.6 -107.0 60 -39.9 -46.9 -54.4 52.4 -71.0 -80.2 -89.9 -100.1 -111.0 20 47.0 -55.2 -64.0 -73.5 -83.6 -94.4 -105.8 -117.9 -130.7 25 -49.1 -57.7 -66.9 -76.8 -87.3 -98.6 -110.5 -123.2 -136.5 3 30 -51.2-, -60.1 -69.7 -80.0 -91.1 -102.8 -115.3 -128A -142.3 40 -54.4 -63.8 -74.0 -84.9 -96.6 -109.1 -122.3 -136.3 -151.0 50 -57.0 56.9 -77.5 -89.0 -101.3 -114.3 -128.2 -142.8 -158.3 60 -59.1 -69.3 -80.4 -92.3 -105.0 -118.5 -132.9 -148.1 -164.1 20 -24.5 -28.8 -33.4 -38.3 143.6 -49.2 -55.2 -61.5 -68.2 25 -25.6 -30.1 -34.9 40.0 45.6 -51.4 -57.7 -64.2 -71.2 f 1 30 -26.7 -31 A -36A -41.7 47.5 -53.6 -60.1 -67.0 -74.2 I! 40 -28.4 -33.3 -38.6 -44.3 50.4 -56.9 -63.8 -71.1 -78.8 50 -29.7 -34.9 -40.5 -46.4 -52.8 -59.6 -66.9 -74.5 -825 60 -30.8 -362 -41.9 -48.1 -54.8 51.8 -69.3 -772 -85.6 20 -38.1 -44.7 -51.8 -59.5 -67.7 =76.4 -85.7 -95.4 -105.8 25 59.8 -46.7 -54.1 -62.1 70.7 -79.8 -89.5 -99.7 -110.5 Partially 30 -41.5 148.7 56.4 -64.8 -73.7 -83.2 -93.3 -103.9 -115.2 Enclosed 2 40 114.0 -51.6 -59.9 -68.7 -78.2 -88.3 -99.0 -110,3 -122.2 i 50 -46.1 -54.1 -62.8 -72.0 -82.0 -92.5 -103.8 -115.6 -128.1 60 -47.8 -56.1 -65.1 -74.7 -85.0 -95.9 -107.6 -119.8 -132.8 20 -53.3 -62.6 -72.6 -83.3 -94.8 -107.0 -119.9 -133.6 6148.1 25 55.7 -65.3 75.8 -87.0 -99.0 -111.7 -125.3 -139.6 -154.6 3 30 -58.0 -68.1 -79.0 -90.7 -103.2 -116.5 -130.6 -145.5 -161.2 40 -61.6 -72.3 -83.8 -96.2 -109.5 -123.6 -138.6 -154A -171.1 50 -64.6 75.8 -87.9 -100.9 -114.8 -129.6 -1452 -161.8 -179.3 60 -66.9 -78.5 -91.1 -104.6 -119.0 -134.3 -150.6 -167.8 -185.9 i DRX19002 FL30304 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services.LLC of any product changes or I quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. i CREEK OREXEL METALS,INC. Metal Roofing TECHNICAL SERVICES,LLC APPENDIXC j .Gable/Hi Roofs to E ;sure.D Roof slo betweeh 2:12 and 6.1:12 . t3udding Mean Basin Wind Speed mph) . T `Zone Roof. 120, 130 4.40 . 150 160. 170 180 : 190 .200 Height ft i 20 -21.9 -25.7 -29.9 -34.3 -39.0 -44.0 49.3 -55.0 -60.9 r 25 -22.7 -26.7 51.0 -35.5 -40.4 -45.6 -51.2 -57.0 -63.2 1 30 -23.6 -27.6- -32.1 -36.8 41.9 .-47.3 -53.0 -59.1 55.4 40 -24.8 -29.1 -33.7 -38.7 -44.0 -49.7 -55.7 -62.1 -68.8 j 50 -25.8 1 -30.3 -35.1 -40.3 45.9 -51.8 58.0 -64.6 1 -71.6 60 -26.6 1 -312 -36.2 111.6 47.3 -53.4 -59.9 -66.7 -73.9 20 -38.2 1 -44.8 52.0 -59.7 -67.9 -76.6 -85.9 -95.7 -106.0 25 -39.6 1 46.5 -53.9 -61.9 -70.4 -79.5 -89.1 -99.2 -110.0 Enclosed 2 30 -41.0 -48.1 -55.8 -64.1 -72.9 -82.3 -92.3 -102.8 -113.9 40 -43.1 -50.6 58.7 -67.4 -76.7 -86.5 -97.0 -108.1 -119.8 50 -44.9 52-7 -61.1 -70.1 79.8 -90.1 -101.0 -112.5 -124.7 60 -46.3 54.3 -63.0 -72.4 -82.3 -92.9 -104.2 -116.1 -128.6 20 56.5 -66.3 -76.8 -88.2 -100.4 -113.3 -127.0 -141.5 -156,8 25 -58.5 -68.7 -79.7 -91.5 -104.1 -117.5 -131.7 -146.8 -162.6 3 30 -60.6 -71.2 -82.5 -94.7 -107.8 -121.7 -136.4 -152.0 -168.4 40 -63.8 -74.8 -86.8 -99,6 -113.4 -128.0 -143.5 -159.9 -177.1 50 -66.4 -77.9 -90.4 -103.7 -118.0 -133.2 -149.4 -166A -184A 60 -68.5 -80A -93.2 -107.0 -121.7 -137.4 -154.1 -171.7 -190.2 20 -29.4 -34.6 40.1 46.0 -52.3 -59.1 56.3 -73.8 -81.8 25 -30.5 -35.8 41.6 -47.7 54.3 -61.3 -68.7 -76.5 54.8 1 30 -31.6 -37.1 43.0 49,4 -56.2 -63.5 -71.2 -79.3 -87.8 40 53.3 59.0 -45.3 -52.0 59.1 -66.8 -74.8 -83A -92.4 50 -34.6 -40.6 -47.1 -54.1 -61.6 -69.5 -77.9 -86.8 1 -96.2 60 -35.7 -41.9 -48.6 -55.8 53.5 -71.7 -80.4 -89.5 -99.2 20 45.7 -53.6 -62.2 -71.4 -81.2 -91.7 -102.8 -114.5 -126.9 25 117.4 55.6 -64.5 -74.0 =84.2 -95.1 -106.6 -118.8 -131.6 Partially 2 30 -49.1 -57.6 -66.8 -76.7 -87.2 -98.5 -110.4 -123.0 -136.3 Enclosed 40 -51.6 -60.6 702 -80.6 -91.8 -103.6 -116.1 -129.4 -143.4 50 53.7 -63.1 -73.1 -83.9 -95.5 -107.8 -120.9 1 -134.7 -149.2 60 -55A -65.0 75.4 -86.6 -98.5 -111.2 -124.7 -138.9 -153.9 20 -64.0 75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7 25 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.3 3 30 -68.7 -80.6 -93.5 -107.3 -122.1 -137.9 -154.6 -172.2 -190.8 40 -72.3 -84.8 -98.3 -112.9 -128.5 -145.0 -162.6 -181.1 -200.7 50 -75.2 -88.3 1 -102.4 -117.5 -133.7 -151.0 -169.2 -188.6 -208.9 60 -77.6 -91,1 -105.6 -121.2 -137.9 -155,7 -174.6 -194.5 -215.5 i DRX19002 FL30304 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G205, The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein.