HomeMy WebLinkAboutProduct Approval - underlayment 1/2/2020 Florida Building Code Online
mklmg
DCIS Home Log In User Registration Hot Topics Submit Surcharge Slats 5 Facts Publications. Contact Us SCIS Site I•lap Links Search
Ald D`x
duct Approval
AUSER:Public User
i
Product Attprnval Menu>Prndurt nr ApPliWtinn Starch>;_rnlicatinn Li,t>Application Detail
FL FL2569-R17
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US 00000
(819)478-2400
memathieu@soprema.ca
Authorized Signature Marc-Etienne Mathieu RECEIVED
memathieu@soprema.ca
Technical Representative Marc-Etienne Mathieu MAR 2.4 1020
Address/Phone/Email 1688 Jean-Berchmans-Michaud Per ���
Drummondville, NON-U
(819)473-2400 Ext 3 t ie C
memathieu@soprema.c
Quality Assurance Representative Jean-Francois Cote, Ph.D. '��L�N"'�D
Address/Phone/Email 1640 rue Haggarty
Drummondville r.
(888)311-3145 CODE C®lilpp��PLIA15NCL
jfcoteCsoprema.ca ST. 9 � 9CIE COUNTY
Category Rooring LUCIE
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich, PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R17 COI 20ig 01 COI NIEMINEN.pd
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTH D4798 2011
ASTM D6163 2008
FM 4474 2011.
.FRSA/TRI April 2012(04-12) 2012
UL 1897 2012
http,://lioridabLlilding.arg/pr/pr_app_dtl.aspx?param=wGEVXQvrtDgsKOFEnckB-108Erxl lJd3xYldirii5DlamBOirHHIZrZrrnt°.'.2b.4t%3d4Irl3d 1/2
1/2/2020 t Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/14/2019
Date Validated 08/14/2019
Date Pending FBC Approval 08/17/2019
Date Approved 10/15/2019
Summary_of Products.
---------------
FL
-- ------FL?k Model,Number or Name Description
2569.1 Soprema Roof Underlayments ;Self adhering roof underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No Ft 746,9 R17 11 2019 06 FINAL ER FL2569-RI7 pddf
Approved for use outside HVHZ:Yes Verified By:Robert Nleminen,P.E.PE-59166
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure:+N/A/-150 Evaluation Reports
Other:1.)Refer to ER Section S for Limits of Use.2.)The FI 2569 R17 AE 2019 06 FINAL ER FL2569-R17 Odf
design pressure noted herein pertains to underlayment systems i Created by Independent Third Party:Yes
used beneath adhesive-set tile systems.Refer to ER Section
5,6.4 for details.
0 a
contact us::26t))Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Fionda is an aA/E[O employer.Copyright 2007-2013 State of Florida.::Pnvacy Statemem::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not Leant your e-mail address released in response to a public records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. 'Pursuant to Section 4$5.275(1),
Florida Statutes,effective October 1,2032,licensees licensed undtr Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here.
Product Approval Accepts:
•i trrl
L—J Credit Card
Safe
haps://floridabuildino.org/))r/pr_app dtl.aspx^param=wGEVXQ+%,tDtIsKOFEnckSIOSErx1L1d3xYldini5DHmBOirHHIZrZrnit%2bA`Y�3d%Sd ?l�
` .
|
| NEMO8etc,
Certificate«yAxmouzamonu2r45s
! ]S3Christian Street, Unit#1]
Oxford,[TOG47O
(2O3)262'8245
EmG|wEsn Eu4Lu4Te TEST Cowsucr [ennpv
40N REPO T
Soprema,Inc. Evaluation Report S18010.06.09-1115
1640 rue Haggerty FL2569-R17
Drummondville, Qudbec.12C 5PS Canada Date of Issuance:06/15/2009
(819)478-2400 Revision IS:06/19/2019
Suupc:
This Evaluation Report is issued under Rule 61G20-9 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products
described herein have been evaluated for compliance with the 611 Edition(2017)Florida Building Code sections noted
herein.
DsScmpnom: 8opneomaRoof Undedaymnents
Luncums: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen,P.E.of any changes to the
product(s), the Quality Assurance or the production facility|ocation(s). N[K8OIetc. requires acomplete review ofthis
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEM0(etc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, acopy ofthis entire Evaluation Report shall beprovided tothe user bythe manufacturer or
|
its distributors and shall beavailable for inspection at the job site atthe request ofthe Building Oyficia|.
This Evaluation Report consists mfpages 1through Q.
�
Prepared by:
The facsimile seal appearing was authorized by Robert
Robert],80. Niem/ne� �� m�a=p�o"��m�e T���mx=ma�
| �
Ror�oRrgb���nmu�16�Ror�oDCA AwEz98s ��2. / electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. nEmosT[ LLC is not owned,operated or controlled by any company trianufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert wieminen.P.E.does not have,nor will acquire,a financial interest in any other entity involved in the eppnnm|process of tile
product.
5. This/,abuilding code evaluation. Neither wckxO|etc,nor Robert wicminpn'P.[.are,|nany way,the Designer nfRecord for any project
onwhich this Evaluation Report,o'previous versions thereof,is/was u,edh`rpe,mirongo,d,signnviuzvoevn/comtained specifically
hxthat purpose.
i
NNEMOletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the
following sections of the 61h Edition(2017)Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations J Conditions of Use set forth
herein.
-.2. STAN64RDS:
Section Property Standard Year
1504.3.1 Wind Resistance FM 4474 2011
1504.3.1 Wind Uplift UL 1897 2012
1507.1.1,1507.2.9.2,R905.1.1, Physical Properties ASTM D1970 2015
R905.2.8.2
1507.3.3,R905.3.3 Physical Properties FRSA/TRI April 2012 2012
FRSA/TRI April 2012(04-12) Physical Properties ASTM D6163 2008
TAS 110 Accelerated Weathering ASTM D4798 2011
Entity Examination Reference Date
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) 531370.03.10-1-R1 04/07/2010
ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) 537210.12.11 12/01/2011
ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRi 04-12(IVIS) 543530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTIVID1970(8C) 544870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) 544870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) 540540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-R1 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&IVIS) 4S-SOPC-18-002.05.19.A 05/31/2019
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 07/18/2017
NEILIO ETC,LLC Evaluation Report 518010.06.09-RIS
Cerrijicare o%Aurhorimion r.2455 G"'EDITION(2017)F6C NON-HVH2 EVALUATION FL2569-1117
Soprema Roof Underlayments Revision 15:06/19/2019
Page 2 of 8
— _-
^ .
fONEMOJetc.
Product Specification Plant(s) Description
4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,
FRSA/TRl April 2012 SBS modified bitumen roof underlayment
4.2 Lastobond Shield ASTM D1970 Drummondville,CLC self-adhering,woven polyethylene surfaced,SBS
Modified biturnen roof underlayinent available in
two widths;36 and 45 inch
4.3 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
40 1 modified bitumen roof underlayment
4.4
temperature,SBS modified bitumen roof
underlayment
4.5 Lastobond Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.6 Lastobond Pro HT-S ASTM 61970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.7 EnviroShlefd ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.P, Lastobond 195 ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-surf aced,
Wadsworth,OH SBS modified bitumen roof underlayment
4,9 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-surfaced,
Protection Sheet Wadsworth,OH SBS modified bitumen roof underlayment
4.10 Lastobond Eco ASTM 01970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.11 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,
HT Wadsworth,OH SBS modified bitumen roof underlayment
4.1] PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,
Smooth Seal HT Wadsworth,OH SBS modified bitumen roof underlayment
4.13 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Gulfport,MS SBS modified bitumen roof underlayment
I Wadsworth,OH
4.14 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Eave&Valley Protector Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH
4.15 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,
Gulfport,MS SBS modified bitumen roof underlayment
Wadsworth,OH I
4.16
FRSA/TRl April 2012 Wadsworth,OH surfaced,SBS modified bitumen roof underlayment
5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E.are,in any way, the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting
ordesign guidance Unless retained specifically for that purpose.
5] This Evaluation Report isnot for use|nFGCHVHZjurisdictions.
Nsmn ETC,Lc Evaluation nepamomnoe.09'ma
�n���m�us 01 EDITION nz5o+m,
a//��'��x.,'/ ' � '
Soprerna Roof uoo*nuvpewu Revision IS:u6/191zom
Page 3o/u
�
. .
ONEMO I etc.
6.3 Fire Classification isnot part of this report; refer mocurrent Approved Roofing Materials Directory for fire ratings of
this product.
5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBCapproval documents. |fnot listed,arequest may bemade tothe Authority Having Jurisdiction for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers.
TAOLE 1:,RoOF COVER OPTIONS
Wood or Slate or
r aymep Asphalt Nail-On Foam-On Metal Composite Composite
Shingles Tile Tile Shakes& Slate
Shingles
Yes
Lastobond TU HT Yes Yes See 5.5.1 Yes Yes Yes
Yes No No. No Yes Yes
R��'TeIA'SMOOTH PLY 40
Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes
C �x
EnviroShield Yes No No Yes Yes Yes
Lastobond Eaves Protection Sheet Yes No No No Yes Yes
Lastobond 195
Grip-Rite Eave&Valley Protector Yes No No No Yes Yes
RESISTO L61244
Lastobond Smooth Seal FIT/Grip- Yes No No Yes Yes Yes
Rite Smooth Seal HT I
No No Yes Yes
Colphene FR GR Yes Yes
5.5.1 "Foarn-On Tile"is limited to use of following Approved tile adhesives underlayment combinations.
Lastobond TU HT ICP Adhesives Polyset"AH-160 FL6332
5.6 Allowable Substrates:
Underlayment Primer Substrates
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA (Optional)ASTM D41, plywood,OSB,Southern Yellow
SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, Elastocol Stick,Elastocol Stick Pine(SYP)
Grip-Rite Eave&Valley Protector,RESISTO LB1244, ASTM D41 structural concrete
Lastobond Smooth Seat HT or Grip-Rite Smooth Seal HT
Colphene FR GR (Optional)ASTM D41 Plywood
ASTM D41 --rstructural concrete
/Refer toTile wmoufbcw, /'/o'Adhesive Manufacturer's Rh'idoProduct Anp, v*/fovo,ertvm/"«Moxcn/xrsismnccrr(fo'nnoce.
NEN10ETC,LLC Evaluation Report S1ooznos�9-ms
Cenwm,00f*/m^rizu'm"*sz45s a'"EDI nom(zvo)mcwom'xvxzEVALUATION posao'm/
svpemuRoof u"drlavm"mms Revision IS:ns/ 9/omy
Page 4urn
� . ^
NNEMOJetc.
Underlayment Primer Substrates
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA
SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, Dens Deck Prime;SECUROCK
EnviroShield,Lastobond TU HT,Lastobond Eaves Protection Zero Gypsum-Fiber Roof Board;
Sheet,Lastobond 195,Lastobond ECO,RESISTO LB1236, (Optional)Elastocol Stick ASTM D226,Type I or 11 felt;
Grip-Rite Eave&Valley Protector,RESISTO LB1244, Sopra-G;Modified Sopra-G
Lastobond Smooth Seat HT,Grip-Rite Smooth Seal HT or
Colphene FR GR
5.6.1 3oprema recommends priming with E|askoco| Stick or Elastoco/ 600c if the final roof cover is not slated for
installation within Z4hours.
5.6.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the
self-adheringundedayment
E.6.2 For installation under mechanically attached prepared roof coverings, insulation orcoxerboa,d shall be attached
per minimum requirements of the prepared roof covering manutacture/s Product Approval. For installations
under foam-on tile systems(Lastobond TU HT only),insulation attachment shall be designed by a qualified design
professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,
Appendix[\Testing Application Standard TAS 114,Appendix]o,UL1897.
5.6.4 For installations under mechanically attached prepared roof coverings,base sheet shall be attached per minimum
codified requirements. For installations under foam-on tile systems(Lastobond TU HT only), base sheet shall be
attached inaccordance with F8S4/TR|April IU12(O4'1Z)orSection 5.6.Sherein.
5.6.5 FRSA/TR|April 2O1Z(04'lI) does not
address wind uplift resistance of all underlayrnent systems beneath foam-on tile systems,where the underlayment
forms part of the load-path. The following wind uplift limitations apply to undedaymen, systems that are not
addressed in FR9A/TR|April ZOI2 (04'I2) and are used infoam-on tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to l margin of safety per F8[ 1504.9 has already been applied). Refer to FR5A/TR|
April 2O12(U4'1Z)urF8[1b09for determination ofdesign wind pressures.
Vl :
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optiona|)E|as¢/co(Stick,E|astoco|Stick Zero orR[3|STOEXTERIOR PRIMER
Under|ayment: Lostobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
#Z :
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: E\astoco|Stick Zero
Under|ayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprerna requirements to ensure no voids no bridging at side and end-laps.
NEW)ETC,LLC Evaluation Report muo1on6.u9-ms
/°^wic^mof Al^ho.umm^&3m»5 a"sonmmpozr}FAC muw'xvxzEVALUATION pu569-nn
svnrwnnRoof onae,|pvmwnts Revision IS:oa/1e/201s
Page so/n
OONERAO, etc.
#3 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered;thoroughly rolled using hand roller and/or weighted
roller in accordance with Soprema requirements to ensure no voids no bridging at side and end-
laps.
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
44 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All
sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood
projections shall be removed/sanded.
Primer: (Optional)RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps.
H5 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC
1517.5.2)spaced 6-inch o.c.at the 4-inch laps and 6-inch o.c, in three(3),equally spaced rows
in the center of the sheet.
Underlayment: Lastobond TU HT, self-adhered; thoroughly rolled using hand roller and/or- weighted roller in
accordance with Soprema requirements to ensure no voids no bridging at side and end-laps
5.6.5.1 All other direct-deck, adhered Soprema underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/TRI April 2012(04-12),Appendix A,Table IA.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case,Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies
marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29
(January 2016)for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, Grip-Rite Eave & Valley
Protector or RESISTO L81244 shall not be left exposed for longer than 30-days after installation.
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S,
Enviro5hield, Lastobond Smooth Seal HT or Grip-Rite Smooth Seal HT shall not be left exposed for longer than 90-
days after installation.
Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after•installation.
NIEK110 ETC,LLC Evaluation Report S18010.06.09-R15
Certificate of-Amhori2ation r<22,:55 G"`EDITION(2017)FBC NON-HVHZ EVALUATION F1.2569-Ri7
Soprema Roof Underlayrnents Revision 15:06/19/2019
Page 6 of 8
1
i
i
14NEMO I etc.
4 5.8 Tile Slippage Limitations(TAS 103 per FRSA/TRI April 2012(04-12)):
4 When loading roof tiles on the underlayment in direct-deck the assemblies,the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
ILF-SU PAdE LIMITATIONS FOR qtKcT-DEcKTitE INSTALLATIONS
i { Maximum
iI Underlayment j Tile Profile Staging Method St
ope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted, 6.12
followed by 8 tiles high on slope,as shown below)
Lastobond TU HT
Lugged '
Colphcne FR GR Flat Max.10-tile stack 5:12
Lugged Max.10-tile stack 6:12
6' INSTALLATIOW,
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements
Subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate with Elastocol Stick,Elastocol Stick Zero or RESISTO
EXTERIOR PRIMER(if applicable).
6.3 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S,EnviroShieid,Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,Lastobond
Smooth Seal HT,Grip-Rite Smooth Seal HT, RESISTO LB1236,Grip-Rite Eave&Valley Protector,RESISTO L81244
or Colphene FR GR:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 or
R905.1.1 for the type of prepared roof covering to be installed,and Soprema published requirements.
6.3.2 Tile Applications(Lastobond TU HT or Col hp ene FR GR onlyl:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self-Adhered Membrane, and Soprema
published requirements.
For mechanically fastened tile roofing over a 2-ply system,consisting of Base Sheet and Self-Adhered Membrane,
fastening of the ASTM D226,Type 11 base sheet shall be in accordance with Soprema requirements,but not less than
that the densities set forth in FRSA/TRI April 2012(04-12),Table 1.
For foam-on tile applications(Lastobond TU HT only),reference is made to Section 5.6.5 herein for wind resistance
limitations that fall outside the scope of FRSA/TRI April 2012(04-1.2).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See
Table 3 herein,and Soprema published requirements for tile staging.
NE MO[TC LLC Evaluation Report 518010.06.09-1115
renifirme of Awhori-ovon x:32455 6iP EDITiON(2017)FOC PJ,,N-HVHZ EV.1LUA1ION FL2559.1117
Soprema Roof underlayments Revision 15:06/19/2019
Page 7 of 8
OMEMO jetc.
------------
BUILDING PERMIT REQUIREMEN S:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
-7—MAR FAcTuRWd'fLANT5-.
Contact the noted QA agency for information on product locations covered for F.A.C.61G20-3 QA requirements.
Refer to Section 4 herein for product&production locations having met codified physical properties specifications.
QMLITY ASS'URANCE WITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
END OF EVALUATION REPORT-
INJEN10 ETC,LLC Evaluation Report 518010.06.09-R15
Cerlificale of Autisorizetion#32455 6"'WITION(2017)F6C NON-HVHZ EVALUATION FL2565-R17
Soprema Roof Undevlayments Revision 25:06/29/2019
Page 8 4018