HomeMy WebLinkAboutTamko 30# Felt
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL12328-R8
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerri Eden
kerri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin, MO 64802
(417) 624-6644 Ext 2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Zachary R. Priest
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/18/2021
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL12328_R8_COI_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4869 2016
ASTM D6380 2003
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/05/2017
Date Validated 10/19/2017
Date Pending FBC Approval 10/20/2017
Date Approved 12/12/2017
Summary of Products
FL #Model, Number or Name Description
12328.1 ASTM Slate Surfaced Roll Roofing Roll roofing surfaced with mineral granules
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.2 ASTM Tile Underlayment Coated organic underlayment
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.3 Master Smooth Asphalt saturated organic underlayment.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.4 Moisture Guard A self-adhering modified bitumen underlayment.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.5 No. 15 ASTM Asphalt saturated organic felt
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.6 No. 15 UL Asphalt saturated organic felt
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.7 No. 30 ASTM Asphalt saturated organic felt
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.8 No. 30 UL Asphalt saturated organic felt
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.9 TAM-FELT Alternate to ASTM D 226, Type II underlayment
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.10 TW Metal and Tile Underlayment self-adhering modified bitumen underlayment
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
12328.11 TW Underlayment self-adhering modified bitumen underlayment
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for limits of use.
Installation Instructions
FL12328_R8_II_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Verified By: Zachary R. Priest 74021
Created by Independent Third Party: Yes
Evaluation Reports
FL12328_R8_AE_TBP14001.4 2017 FBC Eval Report TAMKO
Underlayments final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
CREEK
Technical Services, LLC
TBP14001.4 FL12328-R8 Page 1 of 4 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20 -3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6TH EDITION (2017)
Manufacturer: TAMKO BUILDING PRODUCTS, INC. Issued October 19, 2017
P.O. Box 1404
Joplin, MO 64802
(417) 624-6644
http://www.tamko.com
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
PRODUCT DESCRIPTION
TAMKO® ASTM Slate
Surfaced Roll Roofing
ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated
with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO® ASTM Tile
Underlayment
ASTM D 6380, Class M, Type II underlayment constructed from an organic felt saturated
with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO® Master
Smooth
ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated
with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For
use in non-HVHZ only.
TAMKO® Moisture
Guard®
Self-adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
with a mineral surfacing and a removable release film on the adhesive side and
removable selvedge release tape.
TAMKO® No. 15 ASTM
Asphalt Saturated
Organic Felt
ASTM D 226, Type I underlayment constructed from a non-perforated organic felt that is
saturated with asphalt.
TAMKO® No. 15 UL
Asphalt Saturated
Organic Felt
ASTM D 226, Type I underlayment constructed from a non-perforated organic felt that is
saturated with asphalt.
TAMKO® No. 30 ASTM
Asphalt Saturated
Organic Felt
ASTM D 226, Type II underlayment constructed from a non-perforated organic felt that is
saturated with asphalt.
TAMKO® No. 30 UL
Asphalt Saturated
Organic Felt
ASTM D 226, Type II underlayment constructed from a non-perforated organic felt that is
saturated with asphalt.
TAMKO® TW Metal and
Tile Underlayment
Self-adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO® TW
Underlayment
Self-adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
polymer film on the surface and a removable release film on the adhesive side.
A CREEK
Technical Services, LLC
TBP14001.4 FL12328-R8 Page 2 of 4 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product at tributes that are not
specifically addressed herein.
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
TAMKO® TAM-FELT Alternate to ASTM D 226, Type I and Type II underlayment constructed from a non-
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer’s installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protrusion and corrected prior to underlayment application.
The roof deck shall be constructed of closely fitted plywood shea thing for new or existing construction. Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8” gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMKO® TW Metal and Tile Underlayment and TAMKO® TW
Underlayment shall be 40°F.
b) The minimum application temperature of TAMKO® Moisture Guard® shall be 35 °F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKO® ASTM Slate Surfaced Roll Roofing shall be 2:12.
Underlayments shall be exposed in accordance with the manufacturer’s recommendations, but in no case shall
exposure exceed 30 days.
Exception: TAMKO® TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self-adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Coverings:
Underlayment Asphalt
Shingles
Metal Roof
Panels and
Shingles
Mineral
Surfaced Roll
Roofing
Wood
Shingles and
Shakes
Slate
Shingles
Clay and
Concrete Tile
TAMKO® ASTM Slate
Surfaced Roll Roofing Y1 N N N N Y
TAMKO® ASTM Tile
Underlayment N N N N N Y
TAMKO® Master Smooth Y1 N N N N N
TAMKO® Moisture Guard® Y N N N N N
TAMKO® No. 15 ASTM
Asphalt Saturated Organic
Felt
Y Y Y Y2 N N
TAMKO® No. 15 UL Asphalt
Saturated Organic Felt Y Y Y Y2 Y N
TAMKO® No. 30 ASTM
Asphalt Saturated Organic
Felt
Y Y Y Y Y Y
TAMKO® No. 30 UL Asphalt
Saturated Organic Felt Y Y Y N Y N
TAMKO® TW Metal and Tile
Underlayment Y Y N N N Y
TAMKO® TW Underlayment Y Y N N N N
TAMKO® TAM-FELT Y N N N N N
Notes: 1) Open valley applications per 1507.2.9.2
2) Wood shingles only
A CREEK
Technical Services, LLC
TBP14001.4 FL12328-R8 Page 3 of 4 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product at tributes that are not
specifically addressed herein.
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer’s published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the mini mum application temperature.
5) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer’s application instructions.
7) The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a qualit y assurance program in compliance with
Rule 61G20-3.
REFERENCES
Entity Report No. Standard Year
PRI Construction Materials Technologies (TST6049) TAP-192-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-193-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-214-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies (TST6049) TAP-215-02-01 ASTM D 226 2009
PRI Construction Materials Technologies (TST6049) TAP-216-02-03 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies (TST6049) TAP-217-02-01REV ASTM D 6380 2003(2013)
PRI Construction Materials Technologies (TST6049) TAP-218-02-01 ASTM D 226 2009
PRI Construction Materials Technologies (TST6049) TAP-219-02-01 ASTM D 226 2009
PRI Construction Materials Technologies (TST6049) TAP-220-02-01 ASTM D 6380 2003(2013)
PRI Construction Materials Technologies (TST6049) TAP-222-02-01 ASTM D 4869 2016
PRI Construction Materials Technologies (TST6049) TAP-245-02-01 TAS 103 1995
ASTM D 4798 2011
PRI Construction Materials Technologies (TST6049) TAP-311-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-319-02-01.1 ACC 188 2012
PRI Construction Materials Technologies (TST6049) TAP-387-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST6049) TAP-388-02-01 ASTM D 1970 2015a
UL LLC (TST9628) 13CA12269 ASTM D 226 2009
A CREEK
Technical Services, LLC
TBP14001.4 FL12328-R8 Page 4 of 4 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
2017.10.19
12:15:58
-04'00'