Loading...
HomeMy WebLinkAboutWind Load Calculation St. Lucie County -- - ---- --_- ---.- =_= =- PUBLIC WORKS DEPARTMENT CODE COMPLUNCE DIN,ISIONRECEIVED o� 2300 Virginia Avenue DLJ Fort Pierce,FL 34982 MAR 3 12020 772-462-1553 Design Certification for Wind Lo d�IPT]Wi�t y, Permitting This Certification must be completed by the project design architect or engineer. This Certification must be submitted in duplicate with all applications for building permits involving the construction of new residence (single or multi-family),residential addition,any accessory structure requiring a building permit,and any nonresidential structure. This Certification shall not apply to interior renovations(provided that no exterior structural walls,columns or other components are being affected)and certain other minor building permits. For further assistance,please contact the Building Inspection Office at(772)462-2172. Project Name Missan Homes Office Use Only Street Address 12 Lake Vista Trail Permit Number Unit 203 Occupancy Type Port Saint Lucie,FL 34952 Construction Lee Certification Statement: I certify that,to the best of my knowledge and belief,these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St.Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the appropriate box.) 1 Florida Building Code 2017 Edition with 2010 Supplements and ASCE 7-10 2. Building Design is: Enclosed: Partially Enclosed: Open Building: X 3. Mean Roof Height: N/A Roof Pitch:N/A Internal Pressure Coefficient:NIA 4. Width of End Zone. Wind Speed:165 (3 sec.gust) 5. Building Classification Table 1-1.ASCE 710 FBC Table 1604.5 1 6. Wind Exposure Classification:C Adjustment Factor for Exposure&Height: 98 7. Components&Cladding Wind Pressure on Roof Zone 1 N/A 2 N/A 3 N/A PSF 2 5151 0. . 8. Components&Cladding Wind Pressure on Wall Zone 4 55 55.51-56.3 PSF � ® FOR 9. Components&Cladding wind Pressure on Overhead Garage Door N/A % rYY v��ELIANCE 10. Loads: Floor N/A PSF Roof/dead N/A PSF Roof ive N/A PS 0ODE DOM 11. Shear Walls Considered for Structure? Yes X No (if No,attach&Tnaho�}�M ®���� D 12. Continuous Load Path provided? Yes X No (if No,attach explanation) BOCC 13. Are Component and Cladding Details Provided?Yes X No—(if.No,attach explanation) LU14. Minimum Soil Bearing Pressure: .N/A Presumptive: By Test: PSF jAs witnessed by my seal,I hereby certify that the information-included with this certification is true and correct,to the best of my knowledge and belief. BOWDOING. HUTCHINSON PE#70878 ����urrrrrrrrur�'' Name: Cert#: �`��w Design Firm: BENCHMARK ENGINEERING TC Dam: 3/30/20 70878 : 0 SLCCDV Form#020-00 E�AF = Revised 5/18/09(CL) ONAL