HomeMy WebLinkAboutDECO SpecsDECO Engineering Specs: Beamless Concept CRS Lifts-4 Motor Lifts
A B C D E
Lift Capacity Upper Drive Cable Motors I IP GEAR (lbs) Beams Shafts Winders Cabll:s Spn,;ad Voltage RATIO (TENV) 14" x 6" Uox 1.5" 2''
¾6" (4) ¾ HP4,000 ¼" Thick Sch.40 Sch. 80 S.S. 84" 250
240V/7A to I 29" Long Galv. Alum. I Part
4" x 6" Box 1.5''2" ¾6"
6.000 ¼" Thick Sch. 4l Sch. 80 S.S. 96" (4)¾ HP 250 240V/7A to I 29" Long Galv. Alum. 1 Part 4" x 6" Box 1.5" 2" ¾6" (4)¾11P 250 10,000 ¼" Thick Sch. 4C Sch. 80 S.S. 120" 240V/7A to 1 29" Long Galv. Alum. 2 Part
4" x 6" Uox 1.5" 2" Y.G" (4) ¾ HP13,000 ¼" Thick Sch.40 Sch. 80 S.S. 120" 300 240V/7A to I 29" Long Galv. Alum. 2 Part 4" x 6' Box 1.5" 2" Ji6" (4)I HP 30016.000 ¼" Thick Sch. 80 Sch. 80 S.S. 144" 240V/7A lo I 29" Long Galv. J\lum. 2 Part 14" x 8" Box 1.5" 2" li6" (4)1 HP 300 20.000 ¼" Thick Sch. 80 Sch. 80 S.S. 144" 240V/7A to I 34" Long Galv. Alum. 3 Part
f4" x 8" Box 1.::5" 2" ½" 16 (4)1 !IP 30024.000 ¼" Thick Sch. 8( Sch. 80 S.S. 144" 240V/7A to I 33" Long Galv. Alum. 3 Part
,,-�"';-
H� /�.l. ' _,L--jl A 1\ I \ D -/i'
F
Note: Structure is designed to withstand 160 mph winds provided boats are not
stored on !ills during high wind events and lifts arc in full up position.
F G
l.ower Spanner Beams Pipes
1.5" Alum 4"x4" Box½" Sch 40 Thick 10' 80" 1.5" Alum 4"x6" Box Y," Sch 40 Thick I I' 92"
1.5" Alum.4"x6" Box½' Sch 40Thick 11' 116''
1.5" Alum. 4"x8" Box½" Sch 40 Thick 12' 116"
4",S" Box½" 1.5" Alum.
Thick+ ½"x3" Sch 40 (I) FB-13' 140"
4"�8" Hox Y." 1.5" Alum.
Thick + Y,"x3" Sch 40 (2) FB-14' 140"
4 XI L' l:IOX 1.5" Alum ½" Thick Sch 40 t¾"x3" (2)
Fil.JS' 140"
Piling Mount lo
be through
bolted with (2) ½" or¾" bolts
with baekmg
plates
( 4 Locations )
Bottom penetration to be in conformance with local regulations/codes and a minimum or
10' into the subsurface. All structural components of DECO Lifts consist of(J061-T6
Marine Grade Aluminum. all faslt.:111.:rs and hardwan.: an.: 304 Stainlt:ss Steel.
DECO Power Lift, Inc., 1041 Harbor Lake Dr., Safety Harbor FL 34695
800-204-4178 www.dccoboatlift.com
H
Guide
Posts
80"
80"
80"
120"
120"
120"
120"
Bunk In. or PilingChocks (Qty) noards Lift/Min. Si7.C
Small-2"x811 48"/Min. (4)
I go 10' Lg. 8"
Small ur 2"xl0" (4) Med.-48"/Min. 10-12" J2'Lg. 1 go
Small or 2"xl0"(4) Med.-12' Lg.24"/Min. 10-12"]80
Large-I 8 ° 2"xl0"(4) 24"/Min. or 24° 14' Lg. 10-12"
Large-I 8° (4) 3"xl0"24"/Min. or 24° 10-12"16' Lg.
Largc-18 ° (4) 3"xl 0" or 24° 16' Lg. 16"/Min. 12"
3"xl0"Large-I 8° (4) or 24° 16' Lg. 16"/Min. 12"
Min. Recommemled Wire Size
1'4•hp
220.-
I-hp
220v
Main Panel
220
C FCI B,cak ·
100·
#12
1/10
200' 300' 400'
#10 dQ8 #06
,,os h06 ,104
Through
Bull (Qty)
Size
(8) ½"
(8)
½"
(8) ½"
(8)
¾"
(8)
¾"
(8)
¾"
(8 )
¾"
\ _ "'-:� -J/4t>j!1tt,J t1.1 fe
J/1/1g
...