NOTICE OF ACCEPTANCE NOA RECEIVED www.miamidade.eov/economv
GAF MAR 12 '20.201 Campus Drive
Parsippany,NJ 07054 ST. Lucie County, Permitting
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County) and/ or the AHJ (in areas other than Miami-Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Master Flow®Static and Power Roof Ventilators
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No.16-0209.11 and consists of pages 1 through 5.
The submitted documentation was reviewed by Jorge L.Acebo.
NOA No.: 17-0201.08
MIAMI�DADE COUNTY
. , Expiration Date:09/24/20
Approval Date:09/20/18
Page 1 of 5
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Ventilation
Material: Galvanized Steel
Minimum Slope: 2:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Test Product
Product Dimensions Specification Description
GAF Master Flow®Power Attic Height=8.00" TAS 100(A) Powered Roof Vent,with fan and
Vent—ERV4 Roof Mount Length&Width=25" thermostat with a galvanized hood.
0.020" Thick Gavlanized Steel
GAF Master Flow®Power Attic Height=8.00" TAS 100(A) Powered Roof Vent,with fan and
Vent—ERV5 Roof Mount Length&Width=25" thermostat with a galvanized hood.
0.020" Thick Gavlanized Steel
GAF Master Flowm Power Attic Height=8.00" TAS 100(A) Powered Roof Vent,with fan and
Vent—ERV6 Roof Mount Length&Width=25" thermostat with a galvanized hood.
0.020" Thick Gavlanized Steel
GAF Master Flow®Green Height= 17.50" TAS 100 (A) Solar-Powered Roof Vent,with fan
Machine'Solar-Powered Length& Width=25" and a galvanized hood.
EcoSmart Roof Vent— 0.020"thick Gavlanized Steel
ERVSOLARI
GAF Master Flow®Green Height= 17.50" TAS 100(A) Solar/Electric Powered Roof Vent,
Machine'Dual-Powered Length&Width=25" with fan and a galvanized hood.
EcoSmart Roof Vent— 0.020"thick Gavlanized Steel
ERVHYBRID1
GAF Master Flow®Power Attic Height=8.00" TAS 100(A) Powered Roof Vent,with fan and
Vent—ERV5SMT Roof Mount Length&Width=25" thermostat and humidistat with a
Wi-Fi AtticVent 0.020"thick Gavlanized Steel galvanized hood.
GAF Master Flow® Height=8.00" TAS 100(A) Static Roof Vent,with a
Attic Exhaust Vent Length&Width=25" galvanized hood.
High-Capacity Dome 0.020" Thick Gavlanized Steel
Vent HCD144
MANUFACTURING LOCATION
1. Burgaw,NC
EVIDENCE SUBMITTED
Test Agency Name Test Report Date
PRI Construction Materials Technologies TAS 100(A) LLB-027-02-01 01/23/15
TAS 100(A) LLB-019-02-01 07/12/13
TAS 100 (A) LLB-029-02-01 07/16/15
TAS 100(A) GAF-739-02-01 09/29/16
Intertek UL 1703 SH11040516-001 08/07/14
NOA No.: 17-0201.08
r�tuuM Uilidae CouNn Expiration Date:09/24/20
Approval Date: 09/20/18
Page 2 of 5
APPROVED APPLICATIONS
Tradename: GAF Master Flow Power Attic Vent ERV4 Roof Mount, Power Attic Vent ERV5 Roof Mount,
Power Attic Vent ERV6 Roof Mount, GAF Master Flow Green Machine`' Solar-Powered
EcoSmart Roof Vent ERVSOLARI,GAF Master Flow Green Machine'Dual-Powered EcoSmart
Roof Vent ERVHYBRIDI, GAF Master Flow Power Attic Vent—ERV5SMT Roof Mount Wi-Fi
Attic Vent and GAF Master Flow Attic Exhaust Vent High-Capacity Dome Vent HCD144.
System Type: Mechanical attachment of powered or static vent under asphalt shingle roofs stems.
Cutout: Vent must be located 18-inches from ridgellne. At chosen location and centered between two roof
rafters, cut a 15-inch diameter hole through shingles and sheathing boards.
Using marked position as center point, scribe a circle that is the same diameter as the vent throat
opening. Starting with the drill hole, cut vent hole.
Installation: Vents should be evenly spaced on the rear slope of the roof.
Remove roofing nails from top row of shingles so the flashing of the roof vent will slide under
shingles. Apply approved roof cement around the edge of the hole and approved roof sealant on
underside of the base unit flange, with two 'h-inch beads of approved sealant; with the first bead
%-inch from the throat and the second placed %-inch from outside perimeter. Carefully slide base
of vent under shingles with arrow facing up. Make sure the throat of the vent is centered over vent
hole. Fasten the base to roof decking at corners, and approx. 5_35-inch on center 1-inch from the
outside edge of the flange and 1-inch from stack every 90° with approved roofing nails, keeping
heads of nails under shingles where possible. Use a minimum of 20 nails that shall be of sufficient
length to penetrate through roof sheathing a minimum of/z". See detail drawings herein. Seal all
seams and nails with roofing cement.
Net Free Area: Refer to manufacturers published literature.
GENERAL LIMITATIONS
1. Refer to applicable Building Code required ventilation.
2. For GAF Master Flow Power Attic Vent — ERV4 Roof Mount, Power Attic Vent — ERV5 Roof Mount, and
Power Attic Vent — ERV6 Roof Mount, GAF Master Flow® Green Machine Solar-Powered EcoSmart Roof
Vent — ERVSOLAR1, GAF Master Flow® Green Machine Dual-Powered EcoSmart Roof Vent —
ERVHYBRIDI, GAF Master Flow Power Attic Vent — ERV5SMT Roof Mount Wi-Fi Attic Vent and GAF
Master Flow®Attic Exhaust Vent High-Capacity Dome Vent HCD144 thermostat and wiring shall be installed
in compliance with GAF's published instructions,and in accordance with applicable Building Codes.
3. This acceptance is for installations under asphaltic shingle roof systems only.
4. GAF Master Flow Power Attic Vent—ERV4 Roof Mount, Power Attic Vent—ERV5 Roof Mount, Power Attic
Vent ERV6 Roof Mount, GAF Master Flow Green Machine Solar-Powered EcoSmart Roof Vent—
ERVSOLAR1, GAF Master Flow Green Machine Dual-Powered EcoSmart Roof Vent—ERVHYBRIDI, GAF
Master Flow Power Attic Vent—ERV5SMT Roof Mount Wi-Fi Attic Vent and GAF Master Flow Attic Exhaust
Vent High-Capacity Dome Vent HCD144 shall not be installed on roof mean heights greater than 33 feet.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
6. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the ma-
nufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the
Miami-Dade County Product Control Seal as shown below.
MIAMI-DADE COUNTY
,...• ,
NOA No.: 17-0201.08
MIAMI-DADE COUNTY
�Fg... , Expiration Date:09/24/20
Approval Date:09/20/18
Page 3 of 5
DETAIL DRAWINGS
(All dimensions in inches)
GAF MASTER FLow Power Attic Vent — ERV4 Roof Mount, Power Attic Vent — ERV5 Roof Mount,
Power Attic Vent—ERV6 Roof Mount, GAF Master Flow Power Attic Vent—ERV5SMT Roof Mount Wi-
Fi Attic Vent and GAF Master Flow Attic Exhaust Vent High-Capacity Dome Vent HCD144
25,00
L7—R
8.00
0
0 0 0
25,OD
5.75 V30
LOn
O O O
UP
5.75
'l O �LOU250n
'e0 NAILS
O n Q O
O O O O O
NOA No.: 17-0201.08
MIAMI•DAD,COUNTY Expiration Date:09/24/20
Approval Date:09/20/18
Page 4 of 5
GAF Master Flow®Green Machine'm Solar-Powered EcoSmart Roof Vent—ERVSOLAR1,
GAF Master Flow® Green Machine"Dual-Powered EcoSmart Roof Vent—ERVHYBRIDl
25.00
SOLAR PANEL FRAME
.070' ALUMINUM
SOLAR PANEL MOUNT
.047' G90 GALV
HOOD - .020'
G90 GALV
0
17,31
PANEL UP
10,00'
PANEL DOWN
e.00
0
0 0
HOOD SUPPORTS o
.030' G90 GALV
STACK - .020FLASHING - ,020' G90 GALV
G90 GALV
25.00'
25,00
s.�s ina
o a °
Lon
0
UP
�>5
° ° C 1. 0—
2500 �
e0 NAILS
O 0 O 0
O O O O O
END OF THIS ACCEPTANCE
NOA No.: 17-0201.08
Mut•naoe countTir Expiration Date: 09/24/20
Approval Date:09/20/18
Page 5 of 5