HomeMy WebLinkAboutBuilding Permit Applicationd
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Gate
•
Planning and Development Services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
PERMITTYPE: ROOF
PROPOSED IMPROVEMENT LOCATION:
Permit Number:
Building Permit Application
Commercial Residential X
Address: 6712 DICKINSON TERRACE PORT SAINT LUCIE FL 34953
Property Tax 10 #: 3415-706-0033-000-0
Site Plan Name: ONE
Project Name: ONE
DETAILED DESCRIPTION OF WORK:
REMOVE EXITING ROOF COVER I SHINGLE
INSTALL NEW TRI-BUILT UNDERLAYMENT 1 PEEL & STICK
INSTALL NEW SHINGLE ROOF
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit— check all that apply:
_Mechanical — Gas Tank _ Gas Piping _ Shutters
Electric _ Plumbing _ Sprinklers
Total Sq. Ft of Construction: 2200
Cost of Construction: $ 14,300
Generator
Sq- Ft. of First Floor: 2200
Lot No. 1
Block No. 2
Windows/Doors
Roof 5i12 Pitch
Utilities: —Sewer —Septic Building Height: 8
OWNER/LESSEE:
CONTRACTOR:
Name GARY COMSTOCK
Name: MAURICIO ORELLANA
Address: 6712 DICKINSON TERRACE
Company: ONE CONSTRUCTION & ROOFING
City: PORT SAINT LUCIE FL State: _
Zip Code: 34952 Fax:
Phone No.772-875-7732
Address: 2766 SW EDGARCE ST
City: FLORIDA State: FL
Zip Code: 34953 Fax: NIA
Phone No 772-240-9497
E-Mail: NIA
Fill in fee simple Title Holder on next page if different
from the Owner listed above)
E-Mail ONECONSTRUCTIONSERVICES a@YAHOO.COM
State or County License CCC-1330623
If value of construction is $2500 or more, a RECORDED Notice of Commencement is required.
if value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required.
T
DESIGNER/ENGINEER: Nat Applicable
MORTGAGE COMPANY: _ Not Applicable
Name:
Name:
Address:
Address:
City: State:
City: State:
Zip: Phone
Zip: Phone:
`FEE SIMPL TITLE HOLDER: t Applicable
BONDAG COMPANY: Not Applicable
Name:
Name:
Address: zf
Address:
City:
City:
Zip: hone:
Zip: Phone:
OWNER/
AFFIDVIT: Annlication is hereby made to obtain a permit to do the work and installation as indicated.
i certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie Countyy makes no representation that is granting a permit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply.
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The fallowing building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING
TWICE FOR IMPROYEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT,"
qw-L��- ro
Signature of Owner/ Lessee/Contractor as Agent for Owner Signature of Contractor/License Holder
STATE OF FLORIDA
CO U NTY OF sr LUCIE
Theoing instru ent was acknowledged before me
f rg
this day of , 1 20 2-3 by
GA- j C;0 lq"4�
Name of person making statement -
Personally Known OR Produced Identification
Type of identification
Produced U " Z
� `��1l11iilt4tfflllEE�j�
{Signature of Notary
ryP�ubli . r'tat_�of;l gs )
" G 17 65 1LA 5 � .040
Commission No.t51)gz6V45
2•
y pn,�drr,�0�dsd�C'tp�
REVIEWS FRONT ZON'
COUNTER 4, REVI
DATE
RECEIVED
DATE
COMPLETED
L/
STATE OF FLORIDA
COUNTY OF s� Lucie
The forgoing instrument was acknowledged before me
this $ day of n -, L _ �420� by
uu 6-0 QY('i[}T-)a
Name of person making statement.
Personally Known OR Produced Identification
Type of Ident3catio
Produce Y�
��111!!!i#1tllyll��.
` :7 �
� � Ua� USER i�O���s •.
ul
{Signature of Notary Pub is -State of FIofda j v
* s gF65a5
Commission No.
��: � sse 9,P •• F'ubl�c and �`
'Ev15�OR 1 RE EW PLANS � V REV EW GETATIoN SFREV EWLE I'MANGROVIEW
Florida Building Code Online
BC -Is Horne Log In User Rcgisuation Hot Topics - Submit Surcharge stats & Facts
=0?l r
4Product Approval
or
USER:
��USER: public user
Product A r Menu > Product or Rpj Iration „Search > ARp1[cation us t 7 Apptication Detail
FL # FL16048-R6
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Publications Contact Us BCLS Sete Map Links Search
Product Manufacturer Th-Built Materials Group, LLC
Address/Phone/Email PO Box 70
Rutherford, N1 07070
(600) 516-1485
david.ruizCoiltribui ttmg.com
Authorized Signature David Ruiz
david. ruizOtribui Itmg,com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, N] 07073
(201) 642-2449
david. ruiz@tribuiltmate ria Isg roup.com
Quality Assurance Representative
Address/Phone/Emai I
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Fiardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07/18/2020
Validated By John W. Knezevich, PE
' Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL16048 R6 COI 2017 01 COI Nieminen.pdf
Standard
ASTM D1970
ASTM G155
FM 4474
FRSA/TRI April 2012 (04-12)
UL 1897
Year
2015
2005
2011
2012
2012
https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgtFPmdYiNDWrwipm#AnRBjv9FiYFITk4FLCxcgVtRhfvMW%3d%3d 1/2
` 4/8120n
Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option ❑
Date Submitted
09/25/2017
Date Validated
10/01/2017
Date Pending FBC Approval
10/03/2017
Date Approved
12/12/2017
Su ma of products
FL #
Model, Number or Name nescription
16048A
TRI-BUILT Raof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16048 R6 II 2017 09 FINAL ER TRI-
Approved for use outside HVHZ: Yes
BUILT UNDEPLAYMENTS FL16048-R .pdf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design pressure: +N/A/-150
Created by IndependentThfrd Party; Yes
Other: 1.) The design pressure noted herein pertains to use of
Evaluation Reports
foam -on tile systems overtop the self -adhering underfayment
FL16048 R6 AE 2012 09 FINAL ER I- l
for one particular application. See ER Section 5.6.4 for details.
BUILT UNDERLAYMENTS FLi -R6. df
2.) Refer to ER Section 5 for other Limits of Use.
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road Tatlahat5ee FL 32399 Phone: 850-497-1824
The State of Florida is an AA/EEO employer. Cop r ght Z 07-2013 State of Florida.:: Pri_YdCY Statement ;; ,AccessibilitLtatement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entlty, Instead, conta[;L the office by phone or by traditlonal mail. If you have any questions, please contact SSp.487.1395. *Pursuant to Section 455.275(1),
Flortda Statutes, affective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have One. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an ernaI address which can be made available to the pubti c. To determine if you are a licensee under Cha pter 455, F, S,, please dick here .
Product Approval Accepts:
= Cl to b
Credit Card
Safe
hops:IANww.floridabuildirig.org/pr/pr app_dti.aspx?param=wc3EVXQWtDgtFPmdYiNDWrwipmtAnRBjv9FiYHTk4FLCxcgVtRhfvMw%3d%3d D2
TRINITY ERo
EVALUATION REPORT
TRI-BUILT Materials Group, LLC
PO Box 70
Rutherford, N] 07070
(800) 516-1485
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CH RISTIAN STREET, U NIT #13
OXFORD, CT 06478
(203)262-9245
Evaluation Report A42960.10.12-R6
FL16048-R6
Date of Issuance: 10/25/2012
Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume, The
products described herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity I ERA requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle,
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ER❑ Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official,
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No, 59156, Florida DCA ANE1983
. ram: .. - ❑=-r _�
The fwsimi le seal appearing Xmas auth orizod by Rohert:4fzm in en,
P.E. on 09i2512DI7- This does not serve as an eleC roni cal ly signed
document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylER❑ does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaivates-
2. Trinity I ERD is not awned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4- Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. ]Neither TrinityI ER❑ nor Robert Nieminen, P.E. are, -in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Categary: Underlayment
Compliance Statement: TRl-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6`' Edition (2017) Florida Building Code through testing
1n accordance with the following Standards. Compliance 1s subject to the Installation Requirements and Limitations'
Conditions of Use set forth herein.
2. STANDARDS:
Section
1504.3.1
1504.3.1
1504.6
1507.2.4 / 1507.1.1, 1507.2.9.2
1507.3.3
3. REFERENCES:
Entity
ERD (T5T6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD(TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERD (TST6049)
ERE)(TST6049)
ERD (TST6049)
UL,LLC_ (QUA9625)
UL, LLC. (QUA9625)
4. PRODUCT DESCRIPTION:
Property
Wind Resistance
Wind Uplift
Accelerated Weathering
Physical Properties
Physical Properties
Examination
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Accelerated Weathering
Wind Resistance
Quality Control
Quality Control
Standard Year
FM 4474 2011
L I L 1897 2012
ASTM G155 2005
ASTM D1970 2015
FRSA/TRI April 2012 (04-12) 2012
Reference
S40540.02.13-1
540540.11.13
540540.03.14
S44870.04.14-2
544870,04,14-3
544870.04.14-1
544870.04.14-4
S43530.02.14-1-R1
S43530.05.14
540540.10.14
SC7645.02.15
5C8S20.04.15
SC14045.05.17-RI
Multiple -Listing R16814
Service Confirmation
Date
02/19/2013
11/19/2013
03/26/2014
04/02/2014
04/02/2014
04/10/2014
04/10/2014
05/14/2014
05/28/2014
10/31/2014
02/13/2015
05/27/2015
06/07/2017
12/10/2015
Exp.07/18/2020
4,1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, 5B5
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, 5B5 modified
bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, filth -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, LLC, Evaluation Report A42960.10.12-R6
Certificate of Authorization #95D3 6T" EDITION (2017) FBC NON-HVHI EVALUATION FL16048-116
TR1-QUILT Roof Underlaymerns; (800) 516.1485 Revision S. 09/25/2017
Page 2 of 6
TRINITY ER.D
SA TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC
approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
TABLE $: ROOF COVER OPTIONS
Underlayment Asphalt
Shingles
Nail -On Tile
Foam -On Tile
Metal
Woad Shakes Slate
& Shingles
Tri-Built Sand-R SA Shingle
Underlayment Yes
No
No
No
Yes
Yes
Tri-Built S/A HT TU
Yes
Underlayment Yes
Yes
See 5.5.1
Yes
Yes
Yes
i-Built Smooth HT S/A
I
Yes
rU'nd,,Iayment
No
No Yes
I
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlavment combinations.
TABLE 1A: ALLOWABLE TILE At)HESiVE UNDERLAYMENT COMBINATIONSI
Adhesive
Florida Product Approval
Underlayments
ICP Adhesives Polyset"I AH-160
FL6332
Tri-Built S/A HT TU Underlayment
Dow TIIeBond'"
FL22525
Tri-Built 5/A HT TU Underlayment
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck;
Tri-Built Sand-R SA 5hingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT 5/A
Underlayment applied to:
Plywood; ASTM D41 primed plywood; Q5B; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine, ASTM D41 primed structural concrete.
While not required over plywood, 05B or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OS6 prior to installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A FIT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
Y Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on 'tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix J.
Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, LLL. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6'" EDITION (2017) F B C NON- HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1495 Revision 6: 09/25/2017
Page 3 of 6
TRINITY ERa
5.6.3 Bond to Mechanically Attached Base Laver.
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT 5/A
Underlayment applied to:
� ASTM D225, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -an tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
5.6.4 Wind Resistance for Underla ment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2072 (04-12), Appendix A, Table 1A or
FBC 1609 for determination of design wind pressures.
41 Maximum Design Pressure = -45 0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A J4T TU Underlayment, self -adhered,
#2 Maximum Design Pressure = -67.5 sf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction,
Primer:
Soprema Elastocol 600c
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered.
#3 Maximum Desion
Pressure = -1S0 U psf:
Deck:
Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer:
(Optional) RESISTO EXTERIOR PRIMER
Underlayment:
Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps,
#4 Maximum Design
Pressure = -60.0 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet:
Soprema 5opra-G or Modified 5opra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 15173.2) spaced 6-inch ❑.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment:
Tri-Suitt S/A HT TU Underlayment, self -adhered.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certficate of Authorfaatlan #9503 e' EDITION (2017) F9c NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 5 16-248 5 Revision 6: 09/25/2017
Page 4 of 6
Tf INI- Y ERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRl Apri12012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FRC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk" carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HTTU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 per FRSA TRI April 2012 04-12 :
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE 2: TILE SLIPPAGE Lim rrATIONS FOR DIR€CT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum
I Slope
Flat Max. 10-tile stack 6:12
Lugged Max. 10-tile stack S:12
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high 6:12
on slope, as shown below)
Tri-Built 5/A HT Tit
Underlayment
Lugged
Exterior Research and Design, LLC. Evaluation Report A429W10.12-116
Certificate ofAuthorfsation #9503 O' ELATION (2017) FBC NON-HVH2 EVALUATAgN FLI6049-R6
TRJ-BUILT Roof UnderAayments; (800) 516-1485 Revision 6: 09125/2017
Page 5 of 6
TRINITY ERo
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
Published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below,
6-2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-built Sand-R SA Shingle Underfa men# Tri-Built S A HT TU Underfa men# or Tri-Built Smooth HT 5 A
Underfa ment:
6.3,1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1S07.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roil, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8.12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch ❑.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
63.3 Tile Applications Tri-Built 5 A HT TU Underla ment onl :
Reference is made to FR5A/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
Instructions noted above as a guideline.
Far foam -on the applications, reference is made to Section 5.6.4 herein far wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment, See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for the
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport, MS
9, QUALITY ASSURANCE ENTITY:
UL, LLC —QIJA9625; (314) 573-3406, k.chanceilor@us. uI -cc m
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certrfrcate of Authorization #9503 6" EDITION (2017) FBC NON-HVH7 EVALUATION FL16448-RS
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 6 of 6
312b/2420
6CIS Home Lag In Laser Registration Hot TiWics
dbprProduct Approval
USER: Public User
Florida Building Code Online
foI �x
F c
y
Submit Surcharge Stars & FacLs Publltab Dn5 Contact us BCLS Site Map Links Search
ProdUrt APrLMal Men-nU � Prnd A-P]catiQn Search > A_1213 -a iLU5t a Application Detail
EL #
FL18355-R4
Application Type
Revision
Code Version
2017
Application status
Approved
Comments
Archived
Product Manufacturer TAMKD Building Products LLC
Address/Phone/Email PC Sax 97
Galena, KS 66739
(417) 624-6544 Ext2305
kern edenCaltamko.col-n
Authorized Signature Kern Eden
ke rri_eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PC Box 1404
Joplin, MO 64802
{417}624-6644 Ext2305
kern eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License
PE-74021
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
10118/2021
Validated By
Locke Bowden P.E.
Certificate of Independence
Validation Checklist - Hardcopy Received
FL1 355 R4 C 1 TBP15 1..4 2017 F8C Evai Report Shingles final pdf
Referenced Standard and Year (of Standard) Standard
ASTM D 3161
ASTM D 3462
ASTMD D 71SS
TAS 100
Equivalence of Product Standards
Certified By
Year
2016
2010
2011
1995
Approved Testing Lab
FL1U55 R4 Eouiv UL letter for n ards for FBC 2017 df
httpsJAvwlw.flcridabuild ing"org/pr/pr_app_dtl.aspx?param=wGEVXQwt❑quvosrHazGXQW83MPT3uofKzi31M2Xu9wuWmY6PQIJIli W%3d9/o3d 112
3/29/2620
Sections from the Code
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Products
FL V
18355.1
Method 1 Option D
09/25/2017
09/27/2017
10/08/2017
12/12/2017
02/11/2020
Model, Number or Name
Glass -Seal, Elite Glass -Seal,
Heritage, Heritage Premium,
Heritage Woodgate, Heritage
Mintage, Hip and Ridge, and Vintage
Hip and Ridge Shingles
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ- Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See evaluation report for Jim its of use.
i
i
Description
ASTM D 3452 aspha€t shingles and hip and ridge shingles
I Installation Instructions
FL18355 R4 lI TBP15oo1.4 2217 F13C Val Rep4lrt ShirigLl�s
f7al.❑df
Verified By: Zachary R. Priest PE-74021
Created by Independent Third Party: Yes
Evaluation Reports
FLIS355 R4 AE TBP15 01.4 2017 FBC Eval Report Shiogles
final.pdf
Created by Independent Third Party: Yes
contact Us 2 1 $fair t rte Rva T hascee F 2399 Ph ne: 850-4 7- 824
The State of Florida is art AAIEE-0 employer. Cp_gyrlght 2 07-2i}1 ate of FI ri a.:: PtUV Statement Accessihiliry Staternani :; Rerund meat
Linder Florida law, email addresses are public records. if you do not want your c-mall address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.48.7.1395. -Pursuant to Section 455.275(i),
Florida Statutes, effective October 1, 20 12 , Ifcensees licensed under Chapter 455, F.S. must provide the Depa rtrnent with an email address if they babe one. The em ai Ls
provided may be used for official communication with the licensee. However email addresses are public retard. Ff you do not wish to 5u poly a personal address, please
provide the l7epartrnent with an email address which Can be made avaifabfe to the public_ % determine If you are a licensee under Chapter 455, F5., please click here .
Product Approval Accepts:
Credo Carts
Safe
h€tps:Ilwww.floridabuilding.org)prlpr_app_dtl.aspx?param=wGEVXQwtDquvasrHaxGXQW83MP73uofifzD1M2Xu9wuWmYfiPQIJ[ukQ%3d%3d 212
CREEK
r: e
` TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:
TAMKO BUILDING PRODUCTS
220 West 4"' Street
Joplin, MO 64801
(417) 624-6644
Manufacturing Plants:
Joplin, M❑
Phillipsburg, KS
Frederick, MD
Dallas, TX
Tuscaloosa, AL
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(8I3) 480-3421
FLORIDA BUILDING CODE, 6T" EDITION (2017)
Category: Rooting
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523,6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Issued September 25, 2017
E-ntity
Report No,
Standard
Year
Pill Construction Materials Technologies (TST5878)
TAP-043-02-01
TAS 100
1995
PRI Construction Materials Technologies [7ST5878]
TAP-051-02-01
TAS 100
1995
PRI Construction Materia€s Technologies {TST5878}
TAP-054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
7AP-114-02-01
TAS 100
1995
PRI Construction Materials Technologies {TST5878}
TAP-117-02-01
TAS 100
1995
PRE Construction Materials Technologies (TST5878)
TAP-130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-131-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-165-02-01
TAS 100
1995
PRI Construction Materials Technologies {TST5878}
TAP-280-02-01
TAS 100
1995
PRl Construction Materials Technologies (TST5878)
TAP-303-02-01
TAS 100
1995
PRi Construction Materials Technologies {TST5878)
TAP-307-02-01
TAS 100
1995
FRI Construction Materials Technologies (TST5878)
TAP-314-02-01 Rev 2
TAS 1 DO
1995
PRI Construction Materials Technologies (TST5878)
TAP-315-02-01
ASTM D 6381
2008(2013)e1
PRI Construction Materials Technologies (TST5878)
TAP-317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
A5TM D 3161
2016
UL LLC {TST9628}
UL LLC (TST9628)
04NK24366
ASTM D 3462
2010A
05NK28006
ASTM D 6381
2008(2013)e1
UL 2390
UL LLC (TST9628)
06NK03898
ASTM D 7158
ASTM D 3161
2011
2016
UL LLC (TST9628)
08CA59132
ASTM D 3462
ASTM D 3161
2010A
2016
UL LLC (TST9628)
09NK07896
ASTM ❑ 3161
2016
UL LLC (TST9628)
1 OCA50498
ASTM D 3452
ASTM D 3462
201 DA
2010A
UL LLC (TST9628)
UL LLC (TST9628)
1 OCA64882
ASTM D 3161
2016
11 NK14014
ASTM D 3161
2016
UL LLC (TST9628)
12CA24551
ASTM D 3462
ASTM D 3161
201 DA
2016
UL LLC (TST9628)
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)e1
UL LLC (TST9628)
4787043752
4787148748
ASTM D 3161
ASTM D 7158
2016
2011
ASTM D 3161
2D16
CREEK Technical Services LLC (AN EI1669)
T@P15001.3
ASTM D 3462
2010A
Calculations
2017
TBP15ool.4 FL18355-R4 Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3, The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which tNs report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
'i
Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass -Seal@ 12-114" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick, Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM ❑ 3462.
Glass -Seal
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick &
asphalt shingle with fiberglass mat coated on Both sides with asphalt and surfaced with
Tuscaloosa)
ceramic granules complying with ASTM D 3462,
Glass-5eai
12-14' x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass
(Joplin)
mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ on[ ,
Heritaget
13-114" x 35-318', ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Joplin, Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage] Premium
13-14' x 38-318', ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage@ Premium
12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@ Vintage@
17-112" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage@ Woodgate
13-1/4" x 39-318, ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick)
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462,
Heritage@ Woodgate
12" x 36-318", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick)
asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles
(Frederick & Joplin)
12-114" x 12", ASTM D 3161, Class F fiberglass reinforced; hip and ridge asphalt
shingle surfaced with mineral granules complying with ASTM D 3462,
Vintage] Hip and Ridge 12' x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FL18355-R4 Page 2 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, Or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
INSTALLATION
Elite Glass-SeaND Basic Wind Speed (Vu,t):
(Frederick, Joplin & Basic Wind Speed (Va�d)
Tuscaloosa) Deck (HVHZ);
Glass -Seal
(Frederick, Joplin (Non-
HVHZ) & Tuscaloosa) Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
Nci ft
Area
Nadiing
AMR
TUN
TANiKO BUILDING PRODUCTS
Asphalt Shingles
Max_ 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19i32 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15i32 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-118 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or `6 Nail Pattern' detailed below.
Edge
Figure 1. Elite Glass -Seat & Glass -Seal
4 Nall Pattern (Non-HVHZ only)
NAILS
Butt Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nail Pattern
,7f°
5-1I8"
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3, The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TEC14NICAL SERVICES, LLC
Heritage@ Basic Wind Speed (V„it):
{Dallas, Frederick, Joplin, Basic Wind Speed (Vasa) -
Phillipsburg & Tuscaloosa) Deck (HVHZ)_
Heritage@ Premium
Waifas, Frederick
Phillipsburg & Tuscaloosa} peck (Non-HVHZ):
Heritage® Woodgate
(Dallas & Frederick) Undedayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
M
TAMKO BUILDING PRODUCTS
Asphaft Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15132 in, plywood existing
construction,
In accordance with FBC requirements, -
Solidly sheathed min. 15132 in, plywood or woad plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2.12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using '6 Nail Pattern" detailed
below.
Installed with 5-518 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either A Nail
Pattern" or "6 Nail Pattern" detailed below.
FASTENERS
NAIL ZONE
COMMON
BOND
EXPOSURE 6-618"
12-1I211 --► - 12-3I8" -- -� L
Figure 3. Heritage@, Heritage@ Premium, and Heritage@ Woodgate (Dallas)
4 Nail Pattern (non-HllHZ only)
1 LLt �' - fl2' 1/2ai-p�— 7,-ar8,,►q- 7-1 N—1
Figure 4. Heritage@ & Heritage@ Premium
6 Nail Pattern
NAIL ZONr=
COMMON
BOND
TBP15001.4 FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule fit G20-3. The manufacturer shall notify CREEK
Technicaf Services, LLC of any product changes or quality assurance changes throughout the duration for which this report, is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
�. TECHNICAL SERVICES, LLC
NAIL ZONEI
CONWON BOND
! T
'1r}l8" FEX
StiRE 5 5/9"
i
Figure 5, Heritage@ Woodgate
6 Nail Pattern
11---12-1/2°----� tz-era'--�t^�°�w
4A
I ! 1
I4 t
t ! Common Bond
fJ� /FASTENERS-
7
'tip' .i.-� ;',:•. ::>;.R:: ,�•-.
m f
(O
T
Figure 6. Heritage@, Heritag0) Premium, & Heritage@ Woodgate
Alternate 6 Nail Pattern
PAINT
LINE.
7-718"_--------------- — - - --- - — —:, -- -- �- - _�-NAI L ZONE
i -EDGE OE
COMMON
BOND
EXPOSURE
5-5/8"
ACCEPTABLE
'FASTENER LOCATION
DO NOT FASTEN
ALONG EDGE OF
COMMON BOND
PREFERRED
FASTENER
LOCATION
Figure 7. Heritage4D (Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.4 FL18355-R4 Page 5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61620-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or ather product attributes that are not
specifcafly addressed herein.
-- _ CREEK
TECHNICAL SERVICES, LLC
Heritage® Premium Basic Wind Speed (V,R):
(Frederick) Basic Wind Speed (V,�d):
deck (HVHZ):
Deck (Non-HVHZ)
Underlayment:
Min. slope:
Installation (HVHZ):
Installation {Non-HVHZ):
TAMKC BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min, 19132 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements,
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturers published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "5 Nail Pattern" detailed below.
NAI L ZONFI
COMMON BON[)
W12" QEPOSLIRE
12
Figure 8. Heritage@ Premium tFrederick)
4 Nail Pattern (non-HVHZ only)
NAIL ZONEf
FASTENERS COMMON BOND
__[EXPOSURE 5"
Figure 9. Heritage@ Premium (Frederick)
6 Nail Pattem
TSP15001.4 FL18355-R4 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule fit G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes Or quality assurance changes throughout the duration for which this report is valid,
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKQ BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES. LLC
Heritageg Woodgate Basic Wind Speed (V,it): Max, 194 mph
(Frederick) Basic Wind Speed (Vesd): Max. 15o mph
Deck (Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
Underlayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation {Non-HVHZ}: Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
Instructions. Shingles shall be attached using either "4 Nail
Pattern" or `6 Nail Pattern" detailed below -
FASTENERS
yyamEPOS'' FF��� T
EY
Ai
1 1 l
Figure 10. Heritage® Woodgate (Frederick)
4 Alan Pattern (non-HVHZ only)
NAIL ZONEI
GOMON BOND
NAIL ZONE
COMMON BOND
1
51f '
FEPOSUITE"JL
1 9_1/2n 443+�9-M-43+ 9-1/2' -� �111-1 "
Figure 11. Heritage@ Woodgate (Frederick)
6 Nail Pattern
TBP15001-4 FL18355-R4 Page 7 a, 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or qualib7 assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES. LLC
Heritage® Vintage® Basic Wind Speed (V=,it):
(Phillipsburg) Basic Wind Speed (Vasa)
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Nora-HVHZ):
4d,
TAMIte BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or woad plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7116 in. CSS existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shaft be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall he attached using either "5 Nail
Pattern" or `6 Nail Pattern" detailed below.
Y flASpPon
A parnas x
" i•' ene�s
-- —_-— -- --9-- -----a •-- —
17-1rzI
- il. • 1..
��14'�+s� �7ii3N•—�
Figure 12. Heritage® Vintage@
5 Nail Pattern (non-HVHZ only)
Figure 13. Heritage® Vintage
6 Nail Pattern
EXpD9We
- %Vox
TBP15001.4 FL18355-R4 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use. or other product attributes that are not
specifically addressed herein.
-CREEK
TECHNICAL, SERVICES, LLC
Hip & Ridge Basic Wind Speed (Vujt):
(Frederick & Joplin) Basic Wind Speed (V��):
Deck (HVHZ):
Deck (Non-HVH7):
Underlayment:
Min. slope:
Installation:
TAMK❑ BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
in accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in- plywood or wood plank for
new construction* Min, 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5-118 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direr i n of prevailing wind
n
5-1I8" exposure
Figure 1
y1 7 r
Oft
Fae#ener
3xposure
k-1-5mig
Figure 2 \ I Figure 3
Figure 14. Hip & Ridge (Frederick & Joplin)
TBP 15001.4 FL18355-R4
9 0f 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services; LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or Other product attributes that are not
specifcally addressed herein.
CREEK
TECHNICAL SERVICES. LLC
Vintage& Hip & Ridge Basic Wind Speed (Vuit):
(Phillipsburg) Basic Wind Speed (Vasd):
Deck (HVHZ):
Deck (lion-HVHZ)-
Underlayment:
Min, slope:
Installation:
TRMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19132 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7/16 in. CSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturers published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction of Prevailing wind
rnl
exposure
Start
here
Figure 1
1"
1' I Fastener
Figure 2
5" exposure
"T Figure 3
Figure 15_ Vintage@ Hip & Ridge (Phillipsburg)
TBP15001,4 FL18355-R4 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, L L C of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
A
� CREEK
TECHNICAL SERVICES, LLC
LIMITATIONS
TAMKO BUILDING PRODUCTS
Asphalt Shingles
1) Fire Classification Is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less.
6) Deck substrates shall he clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
13) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7] Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8] All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest. P.E. have demonstrated compliance with the Florida Building
Code, 6`Edition {2017) as evidenced in the referenced documents submitted by the named manufacturer.
"O"VIwill k�rrrrr►
.
No 74021
:-33 STATE GF �:
.0•. :�.
O R l o P •' tom.
'oil IIIIIvtlt
CERTIFICATION OF INDEPENDENCE
2017.09.25
11:31:41
-04t00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE11669
CREEK Technical Services, LLC does not have, nor wilt it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
Linder this evaluation.
Zachary R. Priest: P.E. does not have, nor will acquire, a fnanciai interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.4 FL18355-R4 page 11 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whioh this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.