HomeMy WebLinkAboutTurner EngineeringCONTRACTOR: Master Craft Aluminum Products DESIGN CRITERIA: Applicable Codes, Regulations, and Standards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and AA ADMI Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association. and the AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-10. Loading Criteria 1. Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section 105.1 2. Dead Load: 2 PSF 3. Wind Load: 3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1. 3.2. Ultimate Design Wind Speed: VAT =150 MPH, Nominal Design Wind Speed: Vasa =116 MPH 3.3. Exposure Category, Section 1609.4.3: Exposm-e C 3.4. Screen Enclosure Section 2002.4 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1 - Patio Cover: Non -Habitable, Unconditioned Scope of Work: Does not include analysis of existing structure. Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.024" composite panel Elite 2000, 1.04 density foam, Florida Product Approval Number FL 7561-R4. Foundation Design Existing concrete. No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition free from structural cracking, spat ing, or other deterioration. Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Florida Aluminum Engineering, Inc. 3. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 4. Approved concrete screw anchors to be Simpson Titen-HD or equivalent. 5. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or #12 screws 6" from ends and 12" center to center. 6. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1% - ASTM C 260 iv.Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after hatching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 7. All flashing and weatherproofing shall be provided by the contractor. 8. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEED AND EXPOSURE HAVE BEEN DETERMINED USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. 3X3XO.093 POST 3X3XO.093 POST r` W ( U) O U 2 :D 3X3XO.093 I POST 00 3X3XO.093 POST HOST STRUCTURE I 2X67MI'j-, EDGBEA 3"X48"XO.024" 1.0# DENSITY FOAM COMPOSITE PANEL 2X6SMB EDGE BEAM 7'-6" 3" 3" 8' - O,1 3"X48"XO.024" 1.0# DENSITY FOAM COMPOSITE PANEL 3X3XO.O93 POST A-2 7'-0" 3X3XO.093 POST f 8'-6 f 3X3XO.093 POST 3X3XO.093 POST ,� '� . • ... v r0 .'� 4V coLL "r 6- • 2� 0 0 �: �'Z o a LLJU *uJ : �* Q 0 Z �v••i , W W W tl Z �m W Z Z¢ Z° UJ O a Ln N Z Ln W LL W O J W _ U =Z; Z M 0 0 Z Z J /y z�mm QIA - .- - W WQamz QW Z i M .... w OZ$ cc J W LL LL u9 W > 0 � J W Q O TZ `y ` = J W W f L 14 0 z ot, a?0o°-UJ- DRAWN BY TP DATE DRAWN 03/17/20 REVISION SHEET NO: A-1 iM ALUMINUM MEMBERS DIMENSIONS III/IIt����, HOLLOW SECTIONS�wo" `ttt111/11 �� 2x2: 2"x2"x0.046" .• •d •. ••,•�i��- 2x3:21x31x0.050" ,t��'�``��� ••• % 2 5: 2" 5" 0.050„ LL. A...:'Ly x x x �• c O ..Q:Z OPEN BACK SECTIONS p: W iIC W Q 1x2: 1"x2"x0.040" : (� d Q O Z 1x3: 1"x3"x0.045" iN (5) 1/4" x 4" LAGS W/ ♦ �� > O t— 4 • 1 1/4" DIA. NEOPRENE •. Z SNAP SECTIONS FACED WASHER PER PANE, O •• •�; 2 x 2 Snap: 2" x 2" x 0.045" '',r • • • • • 2 x 4 Snap: 2" x 4" x 0.045" c 11 P�O``,`` * t1 3" x 3" x 0.093" 1 t SELF MATING (SMB) POST 2x4SMB:2"x4"x0.044"x0.100"•' F 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" W W 2 x 6 SMB: 2" x 6" x 0.050" x 0.120" j 3" COMPOSITE W d 2 x 7 SMB: 2" x 7" x 0.057"x 0.120" 2 x 8 SMB: 2" x 8" 0.072" 0.124" 2" 2" 3" 1!8" ALUM ROOF PANEL 3" x 0.062" ALUM Z m t t7 x x x x x ANGLE 2 x 9 SMB: 2" x 9" x 0.072"x 0.124" i EACH SIDE OF UPRIGHT RECEIVING CHANNEL Z W to 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" W/ (1) 3/8" DIA. x 3" CONCRETE W/ #10 x 3/4" TOP AND (4) 3/8" DIA. BOTTOM AS END CAP W Z ANCHORS (2 1/4" EMBEDMENT) THRU BOLTS -i MINIMUM FASTENER EDGE DISTANCE: 1/2" INTO CONCRETE & (z) DIA. x 4" Q Q Z Z THRU BOLTS THROUGHH P POST MINIMUM FASTENER SPACING: 3/4" 2" x 6" SMB N N CONCRETE SCREW ANCHOR: x 0.093" I Z W O J SIMPSON TITEN HD OR EQUIVALENT POST LL SHEET METAL SCREWS (SMS): _ ITW / BUILDEX OR EQUIVALENT d ` n S U z g B COMPOSITE ROOF TO POST CONNECTION z 3" x 3" POST TO DECK CONNECTION DETAILS A_2 SCALE: NTS S d A-2 SCALE: NTS 0 y' _ ^C J Z M W wdaoo GO Z !U ~ a 0w in LL NOTE: HEADER ATTACHMENT TO FASCIA W/ 1/4" LAGS @ 24" O.C. W/ 1 3/4" EMBEDMENT (5) 1/4" x 4" LAGS W/ 1 1/4" DIA. NEOPRENE FLASHING FACED WASHER PER PANEL 3" COMPOSITE ROOF PANELI ` f rEXISTING HOST C/i LJ O LL! (4) 3/8" DIA. `d =� THRU BOLT 1 tWJ W r u) Lo i I O) F- Q ao I r (Z F- co O_ LL DRAWN BY z° x 6" SMB TP 3" x 3" x 0.093" i I DATE DRAWN POST ( _- 03/17/20 - - - - REVISION A - 0 - S-1 COMP. ROOF TO CORNER POST 4TH WALL DETAIL I& " 4 A-2 SCALE: NTS SHEET NO: A-2 z