Loading...
HomeMy WebLinkAboutENCODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: FYC-PSL-Suchon Builder Name: Synergy Homes, LLC Street: Seminile Road Permit Office: City, State, Zip: Fort Pierce , FL, 34951 Permit Number: Owner: Synergy Homes, LLC Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2203.8 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=6.5 1866.70 ft2 b. Frame - Wood, Adjacent R=13.0 337.11 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2158.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2158.00 ft2 6. Conditioned floor area above grade (ft2) 2158.26708984 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(268.0 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 431.65 a. U-Factor: Dbl, U=0.32 268.00 ft2 SHGC: SHGC=0.19 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.8 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtumr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 31.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 7.433 ft. Area Weighted Average SHGC: 0.190 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2158.0 sgft.) Insulation Area EF: 0.930 a. Slab -On -Grade Edge Insulation R=0.0 2158.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.124 Total Proposed Modified Loads: 70.73 PASS Total Baseline Loads: 71.88 11 1 hereby certify that the plans and specifications covered by Review of the plans and S7.47_ this calculation are in compliance with the Florida Energy specifications covered by this 01'1118 t, Code. calculation indicates compliance`,,,{ _ with the Florida Energy Code. ti +trr . '-_.-;r`==j;:.,'�„ �i PREPARED BY: /1oJl��r2rl�4.Bl�l�- Before construction is completed DATE: 3127ZM20 this building will be inspected for compliance with Section 553.908 „ * 0 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy ode. �t7p WE OWNER/AG N : BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). W27/2020 4:00 PM EnergyGaugee USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: FYC-PSL-Suchon User Synergy Homes, LLC 1 Synergy Homes, LLC Single-family New (From Plans) Aston Model Bedrooms: 3 Conditioned Area: 2158 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: Seminile Road County: St. Lucie City, State, Zip: Fort Pierce, FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2158.267 21133.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Whole House 2158.267 21133.2 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Whole House 227 ft 0 2158 ft2 ---- 0.35 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2413 ft2 0 ft2 Medium N 0.85 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2158 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Whole House 0 Blown 2158 ft2 0.11 Wood 3/27/2020 4:00 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY GFIEGKLI51 KhPUK 1 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt TO Space Wall Type1 E Exterior Concrete Block - Int InsWhole House 6.5 15 0 9.33 0 139.9 f12 0 0 0.8 0 2 S Exterior Concrete Block - Int InsldWhole House 6.5 16.67 0 9.33 0 155.5 ft2 0 0 0.8 0 3 S Exterior Concrete Block Int InstdWhole House 6.5 9 0 9.33 0 84.0 ft2 0 0 0.8 0 4 W Exterior Concrete Block Int InsWWhole House 6.5 15 0 9.33 0 139.9 ft2 0 0 0.8 0 5 S Exterior Concrete Block - Int InsWhole House 6.5 15.5 0 9.33 0 144.6 ft2 0 0 0.8 0 6 N Exterior Concrete Block - Int InsWWhole House 6.5 9.5 0 9.33 0 88.6 ft2 0 0 0.8 0 7 S Exterior Concrete Block - Int InsWhole House 6.5 3 0 9.33 0 28.0 ft2 0 0 0.8 0 8 W Exterior Concrete Block - Int InsWhole House 6.5 7.5 0 11 0 82.5 ft2 0 0 0.8 0 -9 W Exterior Concrete Block - Int InsWhole House 6.5 12.33 0 11 0 135.6 ft2 0 0 0.8 0 10 N Garage Frame - Wood Whole House 13 11 0 11 0 121.0 ft2 0 0.23 0.8 0 _ 11 E Exterior Concrete Block - Int InsWhole House 6.5 14 0 11 0 154.0 ft2 0 0 0.8 0 12 W Garage Frame - Wood Whole House 13 6.5 0 11 0 71.5 ft2 0 0.23 0.8 0 13 E Exterior Concrete Block - Int InsWhole House 6.5 5.5 0 11 0 60.5 ft2 0 0 0.8 0 _ 14 SE Exterior Concrete Block - Int InsWhole House 6.5 4.4 0 11 0 48.4 ft2 0 0 0.8 0 15 S Exterior Concrete Block - Int InsWhole House 6.5 1 0 11 0 11.0 ft2 0 0 0.8 0 16 E Exterior Concrete Block - Int InsWhole House 6.5 8.67 0 9.33 0 80.9 ft2 0 0 0.8 0 17 S Exterior Concrete Block - Int InsWhole House 6.5 5.5 0 9.33 0 51.3 ft2 0 0 0.8 0 _ 18 E Exterior Concrete Block - Int InsWhole House 6.5 13 0 9.33 0 121.3 f12 0 0 0.8 0 _ 19 N Exterior Concrete Block - Int InsWhole House 6.5 15 0 9.33 0 139.9 ft2 0 0 0.8 0 _20 N Exterior Concrete Block - Int InsWhole House 6.5 12.5 0 9.33 0 116.6 ft2 0 0 0.8 0 _21 N Exterior Concrete Block - Int InsWhole House 6.5 9 0 9.33 0 84.0 ft2 0 0 0.8 0 _22 W Garage Frame - Wood Whole House 13 15.5 0 9.33 0 144.6 ft2 0 0.23 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Whole House None .29 3 6.7 20 ft2 2 W Insulated Whole House None .29 3 6.7 20 ft2 3 W Insulated Whole House None .29 2.7 8 21.4 ft2 4 S Insulated Whole House None .29 2.5 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wail Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.32 0.19 N 20.0 ft2 1 ft0 in 1 ft0 in Drapes/blinds Exterior 5 2 W 4 Vinyl Low-E Double Yes 0.32 0.19 N 10.0 ft2 1 ft 0 in 1 ft0 in None None 3 S 7 Vinyl Low-E Double Yes 0.32 0.19 N 4.0 ft2 1 ft 0 in 1 ft0 in None None 4 W 9 Vinyl Low-E Double Yes 0.32 0.19 N 40.0 ft2 1 ft0 in 1 ft0 in Drapes/blinds Exterior 5 5 E 11 Vinyl Low-E Double Yes 0.32 0.19 N 96.0 ft2 12 ft 0 in 4 ft 0 in None Interior 5 6 E 13 Vinyl Low-E Double Yes 0.32 0.19 N 30.0 ft2 12 ft 0 in 1 ft0 in None Exterior 5 7 SE 14 Vinyl Low-E Double Yes 0.32 0.19 N 30.0 ft2 12 ft 0 in 1 ft 0 in None Exterior 5 8 E 16 Vinyl Low-E Double Yes 0.32 0.19 N 4.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 9 E 18 Vinyl Low-E Double Yes 0.32 0.19 N 15.0 ft2 1 ft 0 in 1 ft 0 in None Exterior 5 3/2712020 4:00 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHFCKLIST RFPnRT WINDOWS Orientation shown is the entered, Proposed orientation. / v # Wall Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 10 11 N 20 Vinyl Low-E Double Yes 0.32 0.19 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapesrblinds N 21 Vinyl Low-E Double Yes 0.32 0.19 N 4.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 54 ft 9.33 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000311 1761.1 96.68 181.82 .1169 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 31 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Singl SEER: 16 34.8 kBtu/hr 1044 cfm 0.77 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS J # ---- Supply ---- Location R-Value Area ---- Return---- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 431.65 Attic 107.91 Default Leakage Attic (Default) (Default) 1 1 3t27r2020 4:00 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 F:nRM RA(1-S-9f)17 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJ jj Jan [ j Feb (j Mar Apr Ma X Jun JuXjAu E [Xj Se [ Oct Nov Dec HeatinEX]Jan [Xj Feb [X] Mar Jun JXJJul ]Aug Sep o« DeccVenting [( ]r Jan (j Feb [[Xj Mar Apr May !! Jun Jul [[ j Aug E) ] Sep t xl Nov Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System Runtime Vent 75 0 0 0 1 - Electric Strip Heat % 1 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default 8 lbsls .ft. 0 ft2 0 ft 0.3 Whole House 3127/2020 4:00 PM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level 2. Single-family or multiple -family 2. Sing leq family a) Supply ducts R 6.0 b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2158 d) Room unit/PTAC EER 7. Windows, type and area e) Other 16.0 a) U-factor:(weighted average) 7a. 0.320 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.190 14. Heating system: Capacity 31.0 c) Area 7c. 268.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.93 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 6.5 f) Heat recovery unit HeatRec°%o B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 13.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature:- Date. Address of New Home: Seminile Road City/FL Zip: Fort Pierce, FL 34951 3r27/2020 4:00:33 PM EnergyGaugee USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Job Information Builder: Synergy Homes,LLC Address: Seminile Road City: Fort Pierce Air leakage Test Results Community: Permit #: State: FL Lot: NA Zip: 34951 Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2, 0 PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, sub -section ACH50. ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): 1 5,000 60 _ 21133 - CFM(50) Building Volume ACH(50) F-1 PASS When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Method for calculating building volume: Q Retrieved from architectural plans Code software calculated O Field measured and calculated R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official, Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures_ 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Printed Name of Tester: License/Certification #: Date of Test. - Issuing Authority: 3/27/2020 4:00:44 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1