HomeMy WebLinkAboutENCODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: FYC-PSL-Suchon
Builder Name: Synergy Homes, LLC
Street: Seminile Road
Permit Office:
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner: Synergy Homes, LLC
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (2203.8 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=6.5 1866.70 ft2
b. Frame - Wood, Adjacent
R=13.0 337.11 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft2
10. Ceiling Types (2158.0 sqft.)
Insulation Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=20.0 2158.00 ft2
6. Conditioned floor area above grade (ft2)
2158.26708984
b. N/A
R= ft2
c. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
11. Ducts
R ft2
7. Windows(268.0 sgft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 431.65
a. U-Factor: Dbl, U=0.32
268.00 ft2
SHGC: SHGC=0.19
b. U-Factor: N/A
ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
34.8 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtumr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
31.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
7.433 ft.
Area Weighted Average SHGC:
0.190
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2158.0 sgft.)
Insulation Area
EF: 0.930
a. Slab -On -Grade Edge Insulation
R=0.0 2158.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.124
Total Proposed Modified Loads: 70.73
PASS
Total Baseline Loads: 71.88
11
1 hereby certify that the plans and specifications covered by
Review of the plans and
S7.47_
this calculation are in compliance with the
Florida Energy
specifications covered by this
01'1118
t,
Code.
calculation indicates compliance`,,,{
_
with the Florida Energy Code.
ti +trr . '-_.-;r`==j;:.,'�„
�i
PREPARED BY: /1oJl��r2rl�4.Bl�l�-
Before construction is completed
DATE: 3127ZM20
this building will be inspected for
compliance with Section 553.908
„
* 0
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy ode.
�t7p WE
OWNER/AG N :
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
W27/2020 4:00 PM EnergyGaugee USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
FYC-PSL-Suchon
User
Synergy Homes, LLC
1
Synergy Homes, LLC
Single-family
New (From Plans)
Aston Model
Bedrooms: 3
Conditioned Area: 2158
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: Seminile Road
County: St. Lucie
City, State, Zip: Fort Pierce,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70 75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2158.267 21133.2
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Whole House
2158.267 21133.2 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Whole House 227 ft 0
2158 ft2 ---- 0.35 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Hip Composition shingles 2413 ft2 0 ft2 Medium
N 0.85 No 0.9 No 20 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Unvented 0 2158 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Unvented)
Whole House 0 Blown
2158 ft2 0.11 Wood
3/27/2020 4:00 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017
INPUT SUMMARY GFIEGKLI51 KhPUK 1
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
#
Ornt
TO
Space
Wall Type1
E
Exterior
Concrete Block - Int InsWhole House
6.5
15
0
9.33 0
139.9 f12
0
0
0.8
0
2
S
Exterior
Concrete Block - Int InsldWhole House
6.5
16.67
0
9.33 0
155.5 ft2
0
0
0.8
0
3
S
Exterior
Concrete Block Int InstdWhole House
6.5
9
0
9.33 0
84.0 ft2
0
0
0.8
0
4
W
Exterior
Concrete Block Int InsWWhole House
6.5
15
0
9.33 0
139.9 ft2
0
0
0.8
0
5
S
Exterior
Concrete Block - Int InsWhole House
6.5
15.5
0
9.33 0
144.6 ft2
0
0
0.8
0
6
N
Exterior
Concrete Block - Int InsWWhole House
6.5
9.5
0
9.33 0
88.6 ft2
0
0
0.8
0
7
S
Exterior
Concrete Block - Int InsWhole House
6.5
3
0
9.33 0
28.0 ft2
0
0
0.8
0
8
W
Exterior
Concrete Block - Int InsWhole House
6.5
7.5
0
11 0
82.5 ft2
0
0
0.8
0
-9
W
Exterior
Concrete Block - Int InsWhole House
6.5
12.33
0
11 0
135.6 ft2
0
0
0.8
0
10
N
Garage
Frame - Wood Whole House
13
11
0
11 0
121.0 ft2
0
0.23
0.8
0
_ 11
E
Exterior
Concrete Block - Int InsWhole House
6.5
14
0
11 0
154.0 ft2
0
0
0.8
0
12
W
Garage
Frame - Wood Whole House
13
6.5
0
11 0
71.5 ft2
0
0.23
0.8
0
13
E
Exterior
Concrete Block - Int InsWhole House
6.5
5.5
0
11 0
60.5 ft2
0
0
0.8
0
_ 14
SE
Exterior
Concrete Block - Int InsWhole House
6.5
4.4
0
11 0
48.4 ft2
0
0
0.8
0
15
S
Exterior
Concrete Block - Int InsWhole House
6.5
1
0
11 0
11.0 ft2
0
0
0.8
0
16
E
Exterior
Concrete Block - Int InsWhole House
6.5
8.67
0
9.33 0
80.9 ft2
0
0
0.8
0
17
S
Exterior
Concrete Block - Int InsWhole House
6.5
5.5
0
9.33 0
51.3 ft2
0
0
0.8
0
_ 18
E
Exterior
Concrete Block - Int InsWhole House
6.5
13
0
9.33 0
121.3 f12
0
0
0.8
0
_ 19
N
Exterior
Concrete Block - Int InsWhole House
6.5
15
0
9.33 0
139.9 ft2
0
0
0.8
0
_20
N
Exterior
Concrete Block - Int InsWhole House
6.5
12.5
0
9.33 0
116.6 ft2
0
0
0.8
0
_21
N
Exterior
Concrete Block - Int InsWhole House
6.5
9
0
9.33 0
84.0 ft2
0
0
0.8
0
_22
W
Garage
Frame - Wood Whole House
13
15.5
0
9.33 0
144.6 ft2
0
0.23
0.8
0
DOORS
#
Ornt
Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated Whole House
None
.29
3
6.7
20 ft2
2
W
Insulated Whole House
None
.29
3
6.7
20 ft2
3
W
Insulated Whole House
None
.29
2.7
8
21.4 ft2
4
S
Insulated Whole House
None
.29
2.5
8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wail
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp Area
Depth
Separation
Int Shade
Screening
1
E 1
Vinyl Low-E Double Yes
0.32
0.19
N
20.0 ft2
1 ft0 in
1 ft0 in
Drapes/blinds
Exterior 5
2
W 4
Vinyl Low-E Double Yes
0.32
0.19
N
10.0 ft2
1 ft 0 in
1 ft0 in
None
None
3
S 7
Vinyl Low-E Double Yes
0.32
0.19
N
4.0 ft2
1 ft 0 in
1 ft0 in
None
None
4
W 9
Vinyl Low-E Double Yes
0.32
0.19
N
40.0 ft2
1 ft0 in
1 ft0 in
Drapes/blinds
Exterior 5
5
E 11
Vinyl Low-E Double Yes
0.32
0.19
N
96.0 ft2
12 ft 0 in
4 ft 0 in
None
Interior 5
6
E 13
Vinyl Low-E Double Yes
0.32
0.19
N
30.0 ft2
12 ft 0 in
1 ft0 in
None
Exterior 5
7
SE 14
Vinyl Low-E Double Yes
0.32
0.19
N
30.0 ft2
12 ft 0 in
1 ft 0 in
None
Exterior 5
8
E 16
Vinyl Low-E Double Yes
0.32
0.19
N
4.0 ft2
2 ft 0 in
2 ft 0 in
None
Exterior 5
9
E 18
Vinyl Low-E Double Yes
0.32
0.19
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
Exterior 5
3/2712020 4:00 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHFCKLIST RFPnRT
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
v #
Wall
Ornt ID Frame Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
10
11
N 20 Vinyl Low-E Double Yes 0.32 0.19 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapesrblinds
N 21 Vinyl Low-E Double Yes 0.32 0.19 N 4.0 ft2 2 ft 0 in 2 ft 0 in None
Exterior 5
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
440 ft2
440 ft2 54 ft 9.33 ft 0
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000311 1761.1 96.68 181.82 .1169 5
HEATING SYSTEM
#
System Type
Subtype Speed Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None COP:1 31 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
None Singl SEER: 16 34.8 kBtu/hr 1044 cfm 0.77 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use SetPnt Conservation
1
Electric None
Garage 0.93 50 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None None
ft2
DUCTS
J
#
---- Supply ----
Location R-Value Area
---- Return---- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 431.65
Attic 107.91 Default Leakage Attic (Default) (Default)
1 1
3t27r2020 4:00 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
F:nRM RA(1-S-9f)17 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJ jj Jan
[ j Feb
(j Mar
Apr
Ma
X Jun
JuXjAu
E
[Xj Se
[ Oct
Nov
Dec
HeatinEX]Jan
[Xj Feb
[X] Mar
Jun
JXJJul
]Aug
Sep
o«
DeccVenting
[( ]r Jan
(j Feb
[[Xj Mar
Apr
May
!! Jun
Jul
[[ j Aug
E)
] Sep
t xl
Nov
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM
Fan Watts HRV
Heating System
Run Time Cooling System
Runtime Vent
75
0
0
0
1 - Electric Strip Heat
%
1 - Central Unit
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 lbsls
.ft.
0 ft2
0 ft
0.3
Whole House
3127/2020 4:00 PM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
2. Single-family or multiple -family
2. Sing leq family
a) Supply ducts R 6.0
b) Return ducts R 6.0
c) AHU location Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity 34.8
a) Split system SEER
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2158
d) Room unit/PTAC EER
7. Windows, type and area
e) Other 16.0
a) U-factor:(weighted average)
7a. 0.320
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.190
14. Heating system: Capacity 31.0
c) Area
7c. 268.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP 1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 0.93
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 6.5
f) Heat recovery unit HeatRec°%o
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061. 13.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a. 0.0
b) Cross ventilation No
b) Single assembly
11b.
c) Whole house fan No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:-
Date.
Address of New Home: Seminile Road
City/FL Zip: Fort Pierce, FL 34951
3r27/2020 4:00:33 PM EnergyGaugee USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction:
Job Information
Builder: Synergy Homes,LLC
Address: Seminile Road
City: Fort Pierce
Air leakage Test Results
Community:
Permit #:
State: FL
Lot: NA
Zip: 34951
Passing results must meet either the Performance, Prescriptive, or ERI Method
O PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2,
0 PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration, sub -section ACH50.
ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): 1 5,000
60 _ 21133 -
CFM(50) Building Volume ACH(50)
F-1
PASS
When ACH(50) is less than 3, Mechanical Ventilation installation
must be verified by building department.
Method for calculating building volume:
Q Retrieved from architectural plans
Code software calculated
O Field measured and calculated
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official, Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures_
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester:
Printed Name of Tester:
License/Certification #:
Date of Test. -
Issuing Authority:
3/27/2020 4:00:44 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1