Loading...
HomeMy WebLinkAboutPRODAPP TIMBERLINEGENERAL CONTRACTORS GENTILE CORP. CSC 1521 508 'DprE) AT E: TO: WILMD-1w . REF: 'IrI019 Ci4y4m, -"-otb e)Lvv- 7 !A -4- q --J Lj FAX: 561.688. I 398 PHONE: 954.520.0548 954.553.0375 SENTILELLO�00MCAST. NET MIAM ML4,MI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Sheet, Roam 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) w-mv.ndamidade.eov1economv GAF 1 Campus Drive Parsippany, NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline RD®, Timberline' Natural Shadow®, Timberline® American Harvest', and FortitudeTM Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the' expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA # 14-1022.20 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. APPROVED NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category; Roofing Sub-Catesory: Asphalt Shingles Materials: Laminate Deck Type: Wood SCOPE This approves GAF Timberline HD®, Timberline® Natural Shadow', Timberline American® Harvest®, and FortitudeTM Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications GAF Timberline HD® 13 '/A" x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle, with a laminate profile Locations #1, 2, 3, 4, 5, 6, 7 GAF Timberline Natural 13 '/a' x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt Shadow® roof shingle, with a laminate profile Manufacturing Locations #1, 2, 3, 4, 5, 6, 7 GAF Timberline® American 13 '/a' x 39 3/s" TAS 110 Fiberglass reinforced heavy weight asphalt Harvest® roof shingle, with a laminate profile Manufacturing Locations #2, 4, 5, 6 GAF Fortitude TM 13 '/a" x 39 3l8' TAS 110 Fiberglass reinforced heavy weight asphalt Manufacturing roof shingle, with a laminate profile Location #4 MANUFACTURING LOCATION 1. Tampa, FL 2. Michigan City, IN 3. Baltimore, MD 4. Myerstown, PA 5. Ennis, TX 6. Tuscaloosa, AL 7. Dallas, TX NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 2 of 6 EVIDENCE SUBMITTED Test ALrencV Test Identifier Test Name/Report Date Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16 Underwriters Laboratories, Inc. ASTM D3462 11CA48924 10/24/11 Underwriters Laboratories, Inc ASTM D3462 I OCA21994 04/22/11 Underwriters Laboratories, Inc ASTM D3462 1 OCA28717 07/26/11 Underwriters Laboratories, Inc. ASTM D3462 05CA47541 11/10/06 'Underwriters Laboratories, Inc. ASTM D3462 06CA31580 11/30/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-101-02-02 11/02/05 Underwriters Laboratories, Inc. ASTM D3462 06NK05159 08/09/06 PRI Asphalt Technologies, Inc. ASTM D3462 GAF-098-02-02 11/08/05 Underwriters Laboratories, Inc. ASTM D3462 02NK41809 08/11/02 Underwriters Laboratories, Inc. ASTM D3462 03NK26444 10/17/03 Center for Applied .Engineering ASTM D3462 257989 05/13/97 Underwriters Laboratories, Inc. TAS 107 01NK45803 04/13/94 Underwriters Laboratories, Inc. TAS 107 06NK05159 08/09/06 Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04 Underwriters Laboratories, Inc. TAS 107 05CA42840 11/11/05 Underwriters Laboratories, Inc. TAS 107 02NK41811 11/11/02 Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03 Underwriters Laboratories, Inc. TAS 107 04CA13850 08/30/04 Center for Applied Engineering TAS 100 257989 04/01/97 PRI Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04 PRI Asphalt Technologies, Inc. TAS 100 GAF-098-02-01 11/08/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-101-02-01 11/09/05 PRI Asphalt Technologies, Inc. TAS 100 GAF-116-02-02 03/23/06 PRI Asphalt Technologies, Inc. TAS-100 ELK-083-02-01 10/16/02 ELK-084-02-01 10/15/02 ELK-085-02-01 10/14/02 ELK-08 6-02-01 10/24/02 ELK-087-02-01 10/21 /02 ELK-088-02-01 10/16/02 ELK-107-02-01 10/09/03 ELK-108-02-01 10/09/03 ELK-109-02-01 10/09/03 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. h11AM4DADE COUNTY NOA No.: 16-0811.11 I�� • • • Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 3 of 6 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Detail W, attached. LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 4 of 6 DETAIL A COURSE LAYOUT NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 5 of 6 DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN - -- 39-3/811 --� (1m) 14-1 /2" -17-1 /2" 14-1 /2" - 17-1 /2" — (368 - 445mm) (368 - 445mm) /4 6-71/2" - 9-1/2" 6-1/2" - 9-1/2" 13-1 (165- 241mm) (165-241mm) 33i mm If (13- 64 ENHANCED NAILING PATTERN - six nails per shingle* * required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. These shingles MUST be nailed a nominal 6" (152mm) from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. END OF THIS ACCEPTANCE AP.FROVED Mail guide line 5-314" - 6-114" (146mm - 159mm) from bottom of shingle Self seal adhesive on back NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 6 of 6 Paoe Bottom TFWZ.R21 Prepared Roof -covering Materials Prepared Roof -covering Materials See General Information for Prepared Roof -covering Materials GAF 1 CAMPUS DR PARSIPPANY, N7 07054 USA R21 Asphalt glass fiber mat shingles - "Royal Sovereign@", "Sentinel@", "Sentinel@ ASTM D3462", "Timberline® HD", "Timberline@ Natural Shadow", "Timberline@ Ultra HD", "Timberline@ Cool Series", "Timberline@ Majestic", "Timberline@ Majestic 30", "Timberline@ American Harvest'"", "Fortitude'"", "Timberline@ ArmorShield'" II", "Grand Timberline@% "Marquis@ WeatherMax@", "Grand Canyon'"^", "Grand Sequoia@", "Grand Sequoia@ IR", "Grand Sequoia@ ArmorShieid"", "Camelot@", "Camelot@ II", "Capstone@", "Country Mansion@", "Country Mansion@ II", "Grand Slate'"", "Grand Slate'^' II", "Slateline@", "Woodland@", "Monaco'"", "Sienna@" and "Glenwood—" for installation as Class A prepared roof covering. Suitable for installation on minimum 3/8-in. thick plywood roof decks in combination with minimum one ply "Shingle - Mate" or Type 15 or Type 30 underlayment. Also Classified in accordance with ASTM D3161, Class F. Also Classified in accordance with ASTM D3462/D3462M. Also Classified in accordance with ICC ES AC438. Asphalt glass fiber mat shingles - "WeatherBlocker Starter Strip Shingles", and "Pro -Start'"' Starter Strip Shingles" for installation as Class A roof covering. Suitable for installation on minimum 3/8-in. thick plywood in combination with minimum one ply "Shingle -Mate" or Type 15 or Type 30 underlayment. Also Classified in accordance with ASTM D3161/D3161M, Class A. Also Classified in accordance with ASTM D3462/D3462M. Asphalt glass fiber mat shingles- "Royal Sovereign@", "Sentinel@% "Timberline@ HD% "Timberline@ Natural Shadow", "Timberline@ Ultra HD", "Timberline@ Cool Series", "American Harvest", "Fortitude'"", "Marquis@ WeatherMax@% "Grand Canyon"", "Grand Sequoia@", "Grand Sequoia@ IR", and "Camelot@" for installation as Class A prepared roof covering when used with minimum Type 30 underlayment over existing wood shingle roof. Asphalt glass mat hip and ridge shingles- "Timbertex Hip and Ridge" for installation as Class A prepared roof covering. Also been evaluated in accordance with ASTM D3161/D3161M, Class F when Henkel "PL Roofing and Flashing Sealant" or Sonneborn "NPI Gun -Grade Polyurethane Sealant" is applied as specified in manufacturer's application instructions." Also Classified in accordance with ASTM D3462/D3462M. "Z-Ridge" for installation as Class A prepared roof coverings. "Seal -A -Ridge@ ArmorShield'"" and "Seal -A -Ridge@ IR" for installation as Class A prepared roof coverings. Also been evaluated in accordance with ASTM D3161/D3161M, Class A. Also Classified in accordance with ASTM D3462/D3462M. "Seal -A -Ridge@" for installation as Class A prepared roof coverings. Also been evaluated in accordance with ASTM D3161/D3161M, Class F when Henkel Corp. "Loctite PL S30 Roof & Flashing Sealant" is applied as specified in manufacturer's application instructions. Also Classified in accordance with ASTM D3462/D3462M. Last Undated on 2016-09-16 Questions? Print this page Terms of Use Page Top © 2017 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2017 UL LLC".