Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Adams Documents
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: ' - • Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMITTYPE: SWrTTL'w PROPOSED IMPROVEMENT LOCATION: Building Permit Application Commercial Residential xx Address: 18600 TRANQUILITY BASE LN Property Tax ID #: 3215-801-0061-000-3 Lot No. 8 Site Plan Name: ADAMS Block No. 3 Project Name: ADAMS DETAILED DESCRIPTION OF WORK: C L 5 c 0, i pv�C5 viziz E,17 t>(rts�> e zc 63 Afdio cR, cd, CONSTRUCTION INFORMATION: Additional work to be performed under this permit — check all that apply Mechanical _ Gas Tank _ Gas Piping 1iShutters _ Windows/Doors Electric _ Plumbing _ Sprinklers _ Generator _ Roof Pitch Total Sq. Ft of Construction: �q Cost of Construction: $ Y3i 1y 7 Sq. Ft. of First Floor: _ Utilities: _ Sewer _ Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Steven & Leslie Adams Name: Edward J Heritage Address: 18600 Tranquility Base Ln Company: Folding Shutter Corporation City: Port St Lucie State: _ Zip Code: 34987 Fax: n/a Phone No. 772-812-6991 Address: 1862 Dr Martin Luther King Blvd City: West Palm Beach State: FL Zip Code: 33404 Fax: 531-820-8204 Phone No 561-683-4811 E-Mail: n/a Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail info@foldingshutters.com State or County License SCC131151041 If value of construction is $2500 or more, a RECORDED Notice of c.ommencemeni is requireu. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. 151 MRH EXP "C" n t•J 7 r. C 9❑ 9 - OPENINGS ACCORDION ©- OPENINGS ROLLING 10- OPENING STORM PANELS 3 2 1 oADAMS, STEVEN 18600 TRANQUILITY BASE LANE ' ' Castle N Impact Windows PORT SAINT LUCIE, FL 34987 yo _ C) m 1862 Dr Martin Lu[her qng Blvdo g FACTORY DIRECT SINCE 1969 pi —Bach. FL 33404 Castle Impact Windows FACTORY DIRECT SINCE 1969 COMPLETE HURRICANE PROTECTION SOLUTIONS 1862 Or Martin Luther King Blvd Riviera Beach, FL 33404 800.643.6371 Property Information Owner: ADAMS, STEVEN Address: 18600 TRANQUILITY BASE LANE PORT SAINT LUCIE, FL 34987 Building Information Wind Zone: 160 MPH. Exposure Category: C Minimum Building Dimension: 40 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive MNegative L_e'ssure Number Zone Width (in) Height (in)IF Elevation (8) Pressure (psf) (psf) 1 End 48 27.5 7 33.5 -44.8 2 Int 24.25 74.5 7 32.9 -35.8 3 Int 24 74.5 7 32.9 -35.8 4 Int 63.5 74.5 7 30.9 -33.7 5 Int 24 74.5 7 32.9 -35.8 6 Int 24 74.5 7 32.9 -35.8 7 Int 48 74.5 7 31.5 -34.3 8 Int 24 74.75 7 32.9 -35.8 9 Int 48 74.75 7 31.5 -34.3 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (1017) Florida Building Code. Page 1 of 1 Customer: ADAMS WorkOrder Number: 03022020018 N0301 Unit No. Wall Pressure Opening Width Opening Height Shutter Width Shutter Height Slat Length Anchor Spacing 1 -44.8 48 27.5 64.5 32.5 29.25 To.c. 9" o.c. 2 -35.8 24.25 74.5 35.125 79.5 76.25 9"o.c. 9" o.c. 3 -35.8 24 74.5 33.5 79.5 76.25 9"o.c. 9" o.c. 4 -33.7 63.5 74.5 82.125 79.5 76.25 9"o.c. 9" o.c. 5 -35.8 24 74.5 33.5 78.5 75.25 9" o.c. 9"o.c. 6 -35.8 24 74.5 27.625 79.5 76.25 9"o.c. 9" o.c. 7 -34.3 48 74.5 64.5 79.5 76.25 9"o.c. 9"o.c. 8 -35.8 24 74.75 33.5 79.75 76.5 9"o.c. 9"o.c. 9 -34.3 48 74.75 64.5 79.75 76.5 To.c. 9"o.c. Florida Building Code Online Page 1 of 2 i Regulation BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats & Facts Publications Contact Us i SOS Site Map I Links ! Search Product Approval USER: Public User i . drum Product Aooroval Menu > Produc[ or Aoolication Search > Aoollcation List > Application Detail FL # FL17080-R2 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Folding Shutter Corporation Address/Phone/Email 7089 Hemstreet Place West Palm Beach, FL 33413 (561) 683-4811 Ext 7675 edh@foldingshutters.com Authorized Signature Ed Heritage edh@foldingshutters.com Technical Representative Ed Heritage Address/Phone/Email 7089 Hemstreet Place West Palm Beach, FL 33413 (561) 683-4811 Ext 7675 edh@foldingshutters.com Quality Assurance Representative Ed Heritage Address/Phone/Email 7089 Hemstreet Place West Palm Beach, FL 33413 (561) 209-7675 edh@foldingshutters.com Category Impact Protective Systems Subcategory Operable Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Walter A. Tillit Jr., P.E. the Evaluation Report Florida License PE-44167 Quality Assurance Entity PFS Corporation Quality Assurance Contract Expiration Date 12/31/2028 Validated By Troy Bishop, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL17080 R2 COI FOLDING SHUTTER CORP. TITAN II FOLDING IMPACT PROT SYSTEM CERTIFICATION OF INDEPENDENCE 17-0725.0 O.PDF Referenced Standard and Year (of Standard) Standard Year TAS 201, 202, 203 1994 Equivalence of Product Standards Certified By Sections from the Code http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv2aBQpHpQQ... 2/ 12/2019 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Sr.ummary of Products Method 1 Option D 08/17/2017 08/18/2017 08/23/2017 10/10/2017 FL # Model, Number or Name Description 17080.1 Titan II Folding Impact Protective System/HVHZ & NHVHZ (Drawing Extruded aluminum blades folded together through knuckles and retained by tracks to provide Hurricane Protection #17-082) Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL17080 R2 II FOLDING SHUTTER CORP. DRW 17- 082.PDF Impact Resistant: Yes Verified By: Walter A. Tillit Jr., P.E. PE-44167 Design Pressure: +160/-160 Other: Max span is 12'-0" for +46, -46 p.s.f. A.S.D. design Created by Independent Third Party: Yes Evaluation Reports load and 5'-2" for +160, -160 p.s.f. A.S.D. design Ioad.See sheet 13 for additional spans and loads. FL17080 R2 AE FOLDING SHUTTER CORP. TITAN II FOLDING PROT SYSTEM Product Evaluation Report 17- 0725.01 DRWG 17 O.PDF Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M C) ® El E Credit Card Safe http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQ... 2/ 12/2019 'i� L Castle Impact Windows FACTORY DIRECT SINCE 1969 COMPLETE HURRICANE PROTECTION SOLUTIONS 1862 Dr MArtin Luther IGrg Blvd Riviera Beach, FL 334M 800.643.6371 Property Information Building Information Owner: ADAMS, STEVEN Wind Zone: 160 MPH. Address: 18600 TRANQUILITY BASE LANE Exposure Category: C PORT SAINT LUCIE, FL 34987 Minimum Building Dimension: 40 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations C+pening Location Device Device Device Max Positive Max Negative Number Zone Width (in)7[Height (in) Elevation (ft) Pressure (psf) Pressure (psf) 1 Int 65.25 64 7 31.2 -34.0 2 Int 67 75 7 30.8 -33.6 3 Int 71 115.75 7 29.7 -32.5 4 Int 64 75 7 30.9 -33.7 5 Int 153 97.5 7 28.4 -31.2 6 Int 153.5 97.5 7 28.4 -31.2 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads -Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1 Customer: ADAMS Unit No. Wall Pressure Opening Width Opening Height Shutter Width Shutter Height Anchor Spacing Storm Bars Inside Outside Qty. Length Qty. Length 1 -34.0 65.25 64 64 78 6 "o.c. 0 0 0 0 6 "o.c. 2 -33.6 67 75 65.75 89 6 "o.c. 0 0 0 0 6 "o.c. 3 -32.5 71.5 115.75 80.5 115.75 6 "o.c. 0 0 0 0 6 "o.c. 4 -33.7 64 75 62.75 89 6 "o.c. 0 0 0 0 6 "o.c. 5 -31.2 153 97.5 158.25 113 6 "o.c. 0 0 0 0 4 "o.c. 6 -31.2 153.5 97.5 158.75 113 4 "o.c. 0 0 D 0 6 "o.c. Business► Professional Reg1 r�' BCIS Home 1 Log In I User Registration 1 Hot Topics Submit Surcharge Stats & Facts Publications �I. Contact Us I BCIS site Map Links I Search I ' r Product Approval � USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail + . • FL # FL5790-R12 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer American Shutter Systems Association, Inc. Address/Phone/Email 4268 Westroads Drive West Palm Beach, FL 33407 (561)209-8263 bfeeley@easternmetal.com Authorized Signature Bill Feeley Irodriguez@easternmetal.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Shutters Subcategory Roll -up Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer . Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Trevor Johnson Evaluation Report Florida License PE-65624 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2020 Validated By John Henry Kampmann Jr. 4 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL5790 R12 COI CertificationOfIndeoendenceSS.pOf Standard Year ASTM E-1886 2002 ASTM E-1886 2005 ASTM E-1996 2005 ASTM E-1996 2002 ASTM E-330 2002 TAS 201 202 203 1994 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products FL# 5790.1 Method 1 Option D 10/09/2017 10/12/2017 10/17/2017 12/12/2017 Model, Number or Name Description 58mm Bertha End Retention / Non- Roll Shutter System (includes View Port Option) Retention Roll Shutter System (Non- HVHZ) Limits of Use Installation Instructions Approved for use in HVHZ: No FL5790 R12 II InstallationInstructions5 pdf Approved for use outside HVHZ: Yes Verified By: Trevor Johnson, P.E. PE-65624 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: This product shall not be installed within High Velocity FL57 0 R12 AE val ua ionR DortSS,p ld Hurricane Zone. For design loads and spans refer to engineered Created by Independent Third Party: Yes drawings (installation instructions). Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Qqyrlght 2007-2013 State of Florida :: Priv y Statement :: Accessibility Statement :: Refund Statemen Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(I), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe I Florida Building Code Online Page 1 of 2 t u s i ne s s : Professional Regulation c r® BCIS Home : Log In I User Registration I Hot Topic Submit Surcharge 1 Stats & Facts Publications I Contact Us ! BCIS Site Map Unks Search Product Approval USER: Public User pr t 3y Product Aoorc'aI Menu > Product or Application Search > Application List > Application Detail FL # FL28390 Application Type New Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Eastern Metal Supply Address/Phone/Email 4268 Westroads Drive West Palm Beach, FL 33407 (800)432-2204 Irodriguez@easternmetal.com Authorized Signature Frank Bennardo frank@engineeringexpress.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Shutters Subcategory Storm Panels Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Frank L. Bernardo the Evaluation Report Florida License PE-0046549 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2020 Validated By John Henry Kampmann Jr. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL28390 RO C01 Indeo.odf Standard Year ASTM E1886 2005 ASTM E1996 2005 ASTM E330 2014 TAS 201 1994 TAS 202 1994 TAS 203 1994 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqujObYx6FhH79... 9/4/2019 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 10/18/2018 12/17/2018 12/19/2018 02/19/2019 FL # Model, Number or Name Description 28390.1 2" Clear Bertha Storm Panel 2" Clear Bertha Storm Panel (HVHZ and Non-HVHZ) Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL28390 RO II Dwa l.Ddf Approved for use outside HVHZ: Yes Verified By: Frank L. Bernardo PE0046549 Impact Resistant: Yes Design Pressure: +60/-60 Created by Independent Third Party: Yes Evaluation Reports Other: See installation instructions for limitations FL28390 RO AE Evall.Ddf Created by Independent Third Party: Yes 28390.2 2" Clear Bertha Storm Panel - 2" Clear Bertha Storm Panel (HVHZ and Non-HVHZ) - SIMPLIFIED EDITION SIMPLIFIED EDITION Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL28390 RO II Dwo2.Ddf Approved for use outside HVHZ: Yes Verified By: Frank L. Bennardo PE0046549 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +60/-60 Evaluation Reports Other: See installation instructions for limitations and access FL28390 RO AE Eva12 u_df to simplified edition I Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacv Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: M C © eCngc. Credit Card Safe http://www.floridabui lding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDqujObYx6FhH79... 9/4/2019 ;..,.. -- Castle Impact Windows FACTORY DIRECT SINCE 1969 COMPLETE HURRICANE PROTECTION SOLUTIONS 1862 Dr Martin Luther IOng Blvd Riviera Basch. FL 33404 800.643.6371 Property Information Building Information Owner: ADAMS, STEVEN Wind Zone: 160 MPH. Address: 18600 TRANQUILITY BASE LANE Exposure Category: C PORT SAINT LUCIE, FL 34987 Minimum Building Dimension: 40 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number Zone Width (in) Height (in) Elevation (ft) Pressure (psf) Pressure (psf) 1 Int 21.25 21.25 7 33.5 -36.3 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1 Unit No. Wall pressure Opening Size W X H Shutter Width Shutter Height Shutter Span Storm Bars Req'd Anchor Spacing Top Bottom VERT / HORIZ Storm panel Bolted Y/N 1 -36.3 21.25" x 21.25" 26.375" 29.25" 29.25" N/A 12" o.c. VERT N 12" o.c.