HomeMy WebLinkAbout8B. HVAC Manual JBurton 12940 Mack Residence HVAC Load Calculations for Mack Residence 7840 Saddlebrook Drive Port Saint Lucie, FL 34986 t RHVAC. VAC Lm Prepared By; Kristin Kelly Florida Breeze 6928 Vickie Circle Suite B West Melbourne, FI 32904 3219518767 Monday, March 23, 2020 Rhvac is an ALGA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVAC Loads Florida Breeze West Melbourne, FL 32904 -Project Report Genera! Projec# Information Project Title: _ Burton 12940 Mack Residence Designed By: Kristin Kelly Project Date: Monday, March 23, 2020 Client Name: Mack Residence Client Address: 7840 Saddlebrook Drive Client City: Port Saint Lucie, FL 34986 Company Name: Florida Breeze Company Representative: Kristin Kelly Company Address: 6928 Vickie Circle Suite B Company City: West Melbourne, FI 32904 Company Phone: 3219518767 Design Data Reference City: Fort Pierce, Florida Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Elite Software Development, Inc. Burton 12940 Mack Residence Page 2 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rei.Hum Rel.Hum Dry Bulb Difference Winter: 42 39A nla nla 70 nla Summer: 90 78 59% 50% 75 61 Check Figures — _- Total Building Supply CFM: 8,003 CFM Per Square ft.: 0.618 Square ft. of Room Area: 12,940 Square ft. Per Ton: 619 Volume (ft')-. 183,799 Building Loads Total Heating Required Including Ventilation Air: 239,688 Btuh 239.688 MBH Total Sensible Gain: 210,067 Btuh 84 % Total Latent Gain: 40,688 Btuh 16 % Total Cooling Required Including Ventilation Air: 250,756 Btuh 20.90 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\Julia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Florida Breeze Elite Software Development, Inc. m West Metboue, FL 3290.4 Burton 12940 Mack Residence Page 3 Miscellaneous Report �- System 1 Guest Living Bed 7 And 8 (Blue) Input Data Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Different Winter: 42 39.4 80% e n/a 70 n/a Summer: 90 78 59% 50% 75 61.09 System 2 Living Dining Study Parlor (Green) Grains Input Data Outdoor Outdoor Outdoor Indoor Indoor Dry Bulb Wet Bulb Rel.Hum Different Rel.Hum Dry Bulb Inter: 42 39.4 80% n/a 70 - n/a Summer: 90 78 59% 50% 75 61.09 System 3 Flex Bed 9 Bed 10 (Yellow) Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Re1.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 80% n/a 70 n/a Summer.- 90 78 59% 60% 75 61.09 System 4 Kitchen Gym Game Bed 3 4 Theater In Law (Pink) Outdo Outdo Outdo i Input Data or or or Indoor Indoor Grains Dry Wet Rel.H ReI.H Dry Differe Bulb Bulb um um Bulb nce Winter: 42 39.4 80% n/a 70 n/a Slimmer: 90 78 59% 50% 75 61.09 System 5 Second Floor Outdoor - Outdoor Outdoor Indoor -_ indoor Grains 1 Input pata Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dr Bulb Difference] Winter: 42 39.4 80% n/a 70 Na Summer: 90 78 59% 50% 75 61.09 Duct Inputs Main Trunk Runouts - -- Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.01000 0.01000 Pressure Drop: 0.1000 in.wg.1100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 550 ft./min 450 ft./min Maximum Velocity: 600 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.250 AC/hr 0.130 AClhr 766 CFM 398 CFM Infiltration Actual: 0.250 AClhr 0.130 AClhr Above Grade Volume: X 183,799 Cu.ft. X_ 183,799 Cu.ft. 45,950 Cu.ft./hr 23,894 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 766 CFM 398 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.250 AC/hr (116 CFM), Construction: Semi -Tight Summer Infiltration Specified: 0.130 AC/hr (60 CFM), Construction: Semi -Tight ---System 2--- Infiltration & Ventilation Sensible Gain Multiplier. 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.250 AClhr (263 CFM), Construction: Semi -Tight C:lUserslJulialDropboxlRhvac 9 ProjectslBurtonlBurton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & LightCommercial HVAC Loads _ --- - -- - - -- -- Elite Software i0 Mack ment, Ine.' Florida Breeze Burton 12940 Mack Residence West Melbourne, FL 32904 page ¢ Miscellaneous Report (cont`d) f Outside Air Data Summer Infiltration Specified 0.130 AC/hr (137 CFM), Construction: Semi -Tight ---System 3--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 = (1,10 X 0.999 X 28.00 Winter Temp. Difference) Winter Infiltration Specified: 0.250 AClhr (100 CFM), Construction: Semi -Tight Summer Infiltration Specified: 0.130 AClhr (52 CFM), Construction: Semi -Tight ---System 4--- Infiltration & Ventilation Sensible Gain Multiplier: 16,49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.77 Winter Infiltration Specified: 0.250 AClhr (147 CFM), Construction: = (1.10 X 0.999 X 28.00 Winter Temp. Difference) Semi -Tight Summer Infiltration Specified: 0.130 AClhr (77 CFM), Construction: Semi -Tight ---System 5--- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) = Infiltration & Ventilation Sensible Loss Multiplier: 30.77 (0.68 X 0.999 X 61,09 Grains Difference) = 0-10 X 0.999 X 28 00 Winter Temp. Difference) Winter Infiltration Specified: 0.250 AC/hr (140 CFM), Construction: Semi -Tight Summer Infiltration Specified: 0.130 AC/hr (73 CFM), Construction: Semi -Tight C-.\Users\Julia\Dropbox\Rhvac 9 Projects\BurtonlBurton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads i Florida Breeze West Melbourne, FL 32904 Elite Software Development, Inc. Burton 12940 Mack Residence Page 5 r.-!uL.e .a1eU r r C;vlCyy Room or Duct Name Source Minimum Velocity Ma)dmum Velocity Rough. Factor Design $P Ll100 Loss Duct Duct Htg Gig Act putt -. System 1 Vebct Y � Flow Flow Flow Sias Supply Runouts; Zone 1 1-GuestLiving Bed 7And8(BIJe) Built-in 450 750 0.01 0.1 524.3 523 1338 1,338 13--6 OtherDucts in System 1 SupplyMainTru7k Bunt -In 550 600 0.01 0.1 506.9 523 1,338 1,338 22 System 2 Supply Runouts Zone 2-Living Dining Sludy Parlor (Green) Built -In 450 750 0.01 0.1 556 525 1,637 1,637 1" Other Ducts In System2 SuppiyMainTruik Built-in 550 600 0.01 0.1 5212 525 1,637 1,637 24 System 3 Supply Runouts Zone 1 3-Flex Bed 9 Bed 10 (Yellow) Built -In 450 750 0.01 0.1 518.8 474 1= 1,222 12-6 OtherDucts in System3 Supply MainTruik Built -In 550 600 0.01 0.1 560.3 474 1,222 1,222 20 System 4 Supply Runouts Zane 1 4-Kitchen Cyrn Game Bed 3 4 Theater In Law(Pink) guilt -In 450 750 0.01 0.1 543.7 580 1,708 1,708 16-6 OtherDucts in System4 Supply Main Trunk Built -In 550 600 0.01 0.1 543.7 580 1,708 1.708 24 System 5 Supply Runouts Zone 1 5-Second Floor Built-in 450 750 0.01 0.1 534 535 2W 2,097 Z)-6 Other Ducts in System 5 5upplyMainTruik Built -In 550 600 0.01 0.1 568.7 535 2,097 2,097 28 Summary System 1 - Heating Flow: 523 Cooling Flow: 133E System 2 Heating Flow: 525 Cooling Flow: 1637 System 3 Heating Flow: 474 Cooling Flow. 1222 System 4 Heating Flaw: 580 Cooling Flaw: 1708 System 5 Heating Flow: 535 Cooling Flow: 2097 CAUsers\Julia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac -Residential 8 Light Commercial HVAC Loads Florida Breeze Elite Software Development, Inc. West Melbourne, FL 32904 Burton 12940 Mack Residence rSystem 7 Guest Livin Bed 7 And 8 (Blue) Summary Loads Page 6 Component - - Description Area Gen Lat Sen Total _ 2B-m-o: Glazin -low-e (e = 0.60 Double Pane g p ) fixed Quan 84 Loss 918 Gain Gain Gain , sash, metal frame no break, U-value 0.39, SHGC 0 1,414 1,414 0.27 10C-m: Glazing -French door, double pane low-e glass (e 60 940 0 1,425 1,425 = 0.40), metal frame no break, U-value 0.56, SHGC 0.27 2A-m-o: Glazing -Double pane low-e (e = 0.60), operable 60 656 0 1,300 1,300 window, metal frame no break, U-value 0.39, SHGC 0.27 11J: Door -Metal -Fiberglass Core, U-value 0.6 102 1,713 0 1,591 1,591 13AB-Ofcs: Wall -Block, no blanket or board insulation, 1983.7 10,164 0 6,317 6,317 filled core, siding finish, U-value 0.183 18B1-21o: Roof/Ceiling-Roof Joists Between Roof Deck 2496.3 3,285 0 2,464 2,464 and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-21 open cell 1/2 lb. spray foam, 5.5 inches in 2 x 6 joist cavity, 1 inch on joist, U-value 0.047 22A-pm: Floor -Slab on grade, No edge insulation, no 196 6,476 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil, U-value 1.18 Subtotals for structure: 24,152 0 14,511 14,511 People: Equipment: 4 800 920 1,720 Lighting: 0 660 2,300 2,960 Ductwork: Infiltration: Winter CFM: 116, Summer CFM: 60 21,786 3,576 4,299 2,508 0 16,822 996 0 21,121 3,504 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 1,020 1,020 System 1 Guest Living Bed 7 And 8 (Blue) Load Totals: 49,514 8,267 36,569 44,836 Check Figures Supply CFM: 1,338 CFM Per Square ft,: 0.578 Square ft. of Room Area: 2,324 Square ft. Per Ton: 622 Volume (ft'): 27,888 System Loads Total Heating Required Including Ventilation Air: 49,514 Btuh 49.514 MBH Total Sensible Gain: 36,569 Btuh 82 % Total Latent Gain: 8,267 Btuh 18 % Total Cooling Required Including Ventilation Air: 44,836 Btuh 3.74 Tons (Based On Sensible + Latent) Notes -- - Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. CaUsers\Julia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Florida Breeze ddQh West Melbourne, FL 32904 Elite Software Development, Inc. Burton 12940 Mack Residence - -- - -- Rage 7 System 2 Living Dining Study Parlor (Green) Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain _Gain Gain 2B-m-o: Glazing -Double pane low-e (e = 0.60), fixed 291.E 3,184 0 8,281 8,281 sash, metal frame no break, U-value 0.39, SHGC 0.27 1OC-m: Glazing -French door, double pane low-e glass (e 48 752 0 1,164 1,164 = 0.40), metal frame no break, U-value 0.56, SHGC 0.27 11J: Door -Metal - Fiberglass Core, U-value 0.6 60 1,008 0 936 936 13AB-Ofcs: Wall -Block, no blanket or board insulation, 2115.6 10,840 0 6,735 6,735 filled core, siding finish, U-value 0.183 18131-21o: Roof/Ceiling-Roof Joists Between Roof Deck 2496.3 3,285 0 2,464 2,464 and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-21 open cell 1/2 lb. spray foam, 5.5 inches in 2 x 6 joist cavity, 1 inch on joist, I l-value 0.047 22A-pm: Floor -Slab on grade, No edge insulation, no 112 3,700 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil, U-value 1.18 Subtotals for structure: 22,769 0 19,580 19,580 People: 1 200 230 430 Equipment: Lighting: 680 2,500 3,180 Ductwork: 0 16,619 5,586 0 17,874 0 23,460 Infiltration: Winter CFM: 263, Summer CFM: 137 8,094 5,677 2,255 7,932 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 1,156 1,156 System 2 Living Dining Study Parlor (Green) Load Totals: 47,482 12,143 43,595 55,738 Check F Mures Supply CFM: 1,637 CFM Per Square ft.: 0.623 Square ft. of Room Area: 2,630 Square ft. Per Ton: 566 Volume (ft'): 63,130 System Loads Total Heating Required Including Ventilation Air: 47,482 Stuh 47.482 MBH Total Sensible Gain: 43,595 Btuh 78 % Total Latent Gain: 12,143 Btuh 22 % Total Cooling Required Including Ventilation Air: 55,738 Btuh 4.64 Tons (Based On Sensible + Latent) j Notes - - - - - -.- - Rhvac is an ACCA approved Manual J, D and S computer program. --- Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:IUsers\JulialDropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Florida Breeze West Melbourne, FL 32904 _ System 3 Flex Bed 9 Bed (Yellow) Summar Loads Component Description Area San 2A-m-o: Glazing -Double pane low-e (e = 0.60), operable Quan_ Loss 45 492 window, metal frame no break, U-value 0.39, SHGC 0.27 2A-m-d: Glazing -Double pane low-e (e = 0.60), sliding 160 2,419 glass door, metal frame no break, U-value 0.54, SHGC 0.27 2B-m-o: Glazing -Double pane low-e (e = 0.60), fixed 72 786 sash, metal frame no break, U-value 0.39, SHGC 0.27 1OC-m: Glazing -French door, double pane low-e glass (e 12 188 = 0.40), metal frame no break, U-value 0.56, SHGC 0.27 11D: Door -Wood - Solid Core, U-value 0.39 24 262 11J: Door -Metal - Fiberglass Core, U-value 0.6 24 403 13AB-Ofcs: Wall -Block, no blanket or board insulation, 1026.2 5,258 filled core, siding finish, U-value 0.183 12B-Osw: Wall -Frame, R-11 insulation in 2 x 4 stud 472.8 1,283 cavity, no board insulation, siding finish, wood studs, U-value 0.097 18B1-21o: Roof/Ceiling-Roof Joists Between Roof Deck 2496.3 3,285 and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-21 open cell 112 lb. spray foam, 5.5 inches in 2 x 6 joist cavity, 1 inch on joist, U-value 0,047 22A-pm: Floor -Slab on grade, No edge insulation, no 153 5,055 insulation below floor, any floor cover, passive, heavy dry or light wet soil, U-value 1.18 Subtotals for structure: 19,431 People: 2 Equipment: Lighting: 0 D t k Elite Software Development, Inc. Burton 12940 Mack Residence Lat San Total Gain Gain Gain 0 519 519 0 2,206 0 1,220 0 169 0 243 0 374 0 3,268 0 1,104 0 2,464 2,206 1,220 169 243 374 3,268 1,104 2,464 0 0 0 0 400 560 uc wor . 24,367 3,647 Infiltration: Winter CFM: 100, Summer CFM: 52 3,062 2,147 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 System 3 Flex Bed 9 Bed 10 (Yellow) Load Totals: 46,860 6,754 Check Figures 11,567 460 2,100 0 20,687 853 0 35,667 11,567 860 2,660 0 24,334 3,000 0 42,421 apply CFM: 1,222 CFM Per Square ft.: 0.614 Square ft. of Room Area: 1,990 Square ft. Per Ton: 563 Volume (ft')-. 23,880 System Loads Total Heating Required Including Ventilation Air: 46,860 Btuh 46.860 MBH Total Sensible Gain: 35,667 Btuh 84 % Total Latent Gain: 6,754 Btuh 16 % Total Cooling Required Including Ventilation Air: 42,421 Btuh 3.54 Tons (Based On Sensible + Latent) FNoteS Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:IUsers\Julia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Florida Breeze West Melbourne, FL 32904 Burton 12940 Mack Residence . - --- - - Page 9 System 4 Kitchen Gym Game Bed 3 4 Theater In Law (Pink) Summary Loads Component - T Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 2A-m-d: Glazing -Double pane low-e (e = 0.60), sliding 320 4,838 0 6,183 6,183 glass door, metal frame no break, U-value 0.54, SHGC 0.27 1OC-m: Glazing -French door, double pane low-e glass (e 24 376 0 338 338 = 0.40), metal frame no break, U-value 0.56, SHGC 0.27 2B-m-o: Glazing -Double pane low-e (e = 0.60), fixed 48 526 0 1,040 1,040 sash, metal frame no break, U-value 0.39, SHGC 0.27 2A-m-o: Glazing -Double pane low-e (e = 0,60), operable 60 656 0 1,908 1,908 window, metal frame no break, U-value 0.39, SHGC 0.27 11J: Door -Metal - Fiberglass Core, U-value 0.6 48 806 0 748 748 11 D: Door -Wood - Solid Core, U-value 0.39 48 524 0 486 486 13AB-Ofcs: Wall -Block, no blanket or board insulation, 1532 7,850 0 4,879 4,879 filled core, siding finish, U-value 0.183 12B-Osw: Wall -Frame, R-11 insulation in 2 x 4 stud 999.4 2,714 0 2,336 2,336 cavity, no board insulation, siding finish, wood studs, U-value 0.097 18B1-21o: Roof/Ceiling-Roof Joists Between Roof Deck 2496.3 3,285 0 2,464 2,464 and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-21 open cell 1/2 lb. spray foam, 5.5 inches in 2 x 6 joist cavity, 1 inch on joist, U-value 0.047 22A-pm: Floor -Slab on grade, No edge insulation, no 262 8,656 0 0 0 insulation below floor, any floor cover, passive, heavy dry or light wet soil, U-value 1.18 Subtotals for structure: 30,231 0 20,382 20,382 People: 3 600 690 1,290 Equipment: 804 2,850 3,654 Lighting: 0 0 0 Ductwork: 17,123 3,319 17,017 20,336 Infiltration: Winter CFM: 147, Summer CFM: 77 4,533 3,179 1,263 4,442 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 2,580 2,580 System 4 Kitchen Gym Game Bed 3 4 Theater In Law (Pink) Load Totals: Check Figures Supply CFM: 1,708 Square ft. of Room Area: 2,946 Volume (ft3): 35,351 System Loads Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: 51,887 44,782 7,902 52,684 51,887 7,902 44,782 52,684 CFM Per Square ft.: 0.580 Square ft. Per Ton: 671 Btuh 51.887 MBH Btuh 85 % Btuh 15 % Btuh 4.39 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:IUsers\Julia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Florida Breeze West Melbourne, FL 32904 _ System 5 Second Floor Summary Loads Component i Description 10C-m: Glazing -French door, double pane low-e glass (e = 0.40), metal frame no break, U-value 1.43, SHGC 0.43 2B-m-o: Glazing -Double pane low-e (e = 0.60), fixed sash, metal frame no break, U-value 0.39, SHGC 0.27 10C-m: Glazing -French door, double pane low-e glass (e = 0.40), metal frame no break, U-value 0.56, SHGC 0.27 2B-m-o: Glazing -Double pane low-e (e = 0.60), fixed sash, metal frame no break, U-value 0.67, SHGC 0.61 2A-m-o: Glazing -Double pane low-e (e = 0.60), operable window, metal frame no break, U-value 0.84, SHGC 0.61 2A-m-o: Glazing -Double pane low-e (e = 0.60), operable window, metal frame no break, U-value 0.39, SHGC 0.27 11J: Door -Metal - Fiberglass Core, U-value 0.6 1213-0sw: Wall -Frame, R-11 insulation in 2 x 4 stud cavity, no board insulation, siding finish, wood studs, U-value 0.097 18B1-21o: Roof/Ceiling-Roof Joists Between Roof Deck and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-21 open cell 112 lb. spray foam, 5.5 inches in 2 x 6 joist cavity, 1 inch on joist, U-value 0.047 22A-pm: Floor -Slab on grade, No edge insulation, no insulation below floor, any floor cover, passive, heavy dry or light wet soil, U-value 1.18 Subtotals for structure. - People: Equipment. - Lighting: Ductwork: Infiltration: Winter CFM: 140, Summer CFM: 73 Ventilation: Winter CFM: 0, Summer CFM: 0 AED Excursion: Elite Software Development, Inc. Burton 12940 Mack Residence Page 10 Area Sen Lat Sen Total - Q_uan _ Loss Gain Gain Gain 12 480 0 551 _ 5-51 97.2 1,062 0 2,402 2,402 36 564 0 855 855 316A 5,934 0 19,484 19,484 15 353 0 1,069 1,069 30 328 0 954 954 96 1,612 0 1,497 1,497 2982.5 8,100 0 6,975 6,975 2496.3 3,285 0 2,464 2,464 343 11,333 0 0 0 33,051 0 36,251 36,251 4 800 920 1,720 850 3,120 3,970 0 0 0 6,592 956 7,913 8,868 4,302 3,017 1,198 4,215 0 0 0 0 0 0 52 52 System 5 Second Floor Load Totals: 43,945 5,623 49,454 55,077 Check Figures Supply CFM: 2,097 CFM Per Square ft.: 0.687 Square ft. of Room Area: 3,050 Square ft. Per Ton: 665 Volume (ft'): 33,550 System Loads Total Heating Required Including Ventilation Air: 43,945 Btuh 43.945 M13H Total Sensible Gain: 49,454 Btuh 90 % Total Latent Gain: 5,623 Btuh 10 % Total Cooling Required Including Ventilation Air: 55,077 Btuh 4.59 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D All computed results are estimates as building use and weather may vary. C:IUserslJulia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM vac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Florida Breeze Burton 12940 Mack Residence WestMelbourne, FL 32904 Pale 11 System 5 Second Floor Summa Loads (cont`d) --- Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. CaUsers\Julia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Florida Breeze Burton 12940 Mack Residence West Melbourne, FL 32904 Page 12 Equipment Data - System i -- Guest Living Bed 7 and 8 (Blue) Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: Description: AHRI Reference No.: Capacity: Efficiency: Heating System Type: Model: Tradename: Manufacturer: Description: Capacity: Efficiency: Air Source Heat Pump DZ16TC0481C* CA*F4961 *6D*+MBVC2000**-1A*+TX DZ16TC DAIKIN Air Source Heat Pump 202148839 48,000 16 SEER Air Source Heat Pump DZ16TC0481C* DZ16TC DAIKIN Air Source Heat Bump 47,000 9 HSPF This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDE: 70F, Sen. gain: 36,569 Btuh, Lat. gain: 8,267 Btuh, Sen. loss: 49,514 Btuh, Entering clg. coil DB: 79.9F, Entering clg. coil WB: 642F, Entering htg. coil DB: 53.9F, Cig. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1338 CFM, Req. htg. airflow: 523 CFM C:IUsers\JulialDropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Florida Breeze Burton 12940 Mack Residence West Melbourne, FL 32904 Page 13 Equipment Data - System 2 - Living Dinin Study Parlor (Green) Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: Description: AHRI Reference No.: Capacity: Efficiency: Heating System Type: Model: Tradename: Manufacturer: Description: Capacity: Efficiency: Air Source Heat Pump DZ16TC0601C* CA*F4961 *6 D*+M BVC2000**-1 A"+TX DZ16TC DAIKIN Air Source Heat Pump 202148727 56,500 17 SEER Air Source Heat Pump DZ16TC0601 C* DZ16TC DAIKIN Air Source Heat Pump 59,600 9.5 HSPF This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODS: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 43,595 Btuh, Lat. gain: 12,143 Btuh, Sen. loss: 47,482 Btuh, Entering clg. coil DB: 79.2F, Entering clg. coil WB: 63.917, Entering htg. coil DB: 57.8F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1637 CFM, Req. htg. airflow: 525 CFM C:IUsers\Julia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software De�eiopment, Inc. Florida Breeze Burton 12940 Mack Residence West Melbourne, FL 32904 _ Page_ 14 Equipment Data - System 3 - Flex Bed-9 Bed 10 (Yellow) -- Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: Description: AHRI Reference No.. - Capacity: Efficiency: Heating System Type: Model: Tradename: Manufacturer: Description: Capacity: Efficiency: Air Source Heat Pump DZ16TC0481C* CA*F4961 *6 D*+M BVC2000**-1 A*+TX DZ16TC DAIKIN Air Source Heat Pump 202148839 48,000 16 SEER Air Source Heat Pump DZ16TC0481C* DZ16TC DAIKIN Air Source Heat Pump 47,000 9 HSPF This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SOD& 9017, SOWB: 7817, WODB: 42F, S1DB: 7517, SIRH: 50%, W1DB: 70F, Sen. gain: 35,667 Btuh, Lat. gain: 6,754 Btuh, Sen. loss: 46,860 Btuh, Entering clg. coil DB: 81.6F, Entering clg. coil WB: 64.7F, Entering htg. coil DB: 50.1F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1222 CFM, Req. htg. airflow: 474 CFM CaUsers\Julia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Florida Breeze Burton 12940 Mack Residence West Melbourne, FL 32904 _ Page 15 Equipment Data - S stem 4 - Kitchen gym Game Bed 3 4 Theater In Law (Pi *0 Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: Description: AHRI Reference No.: Capacity: Efficiency: Heating System Type: Model: Tradename: Manufacturer: Description: Capacity: Efficiency: Air Source Heat Pump DZ16TC0601 C* CA*F4961 *6D*+MBVC2000**-1A*+TX DZ16TC DAIKIN Air Source Heat Pump 202148727 56,500 17 SEER Air Source Heat Pump DZ16TC0601C* DZ16TC DAI KI N Air Source Heat Pump 59,500 9.5 HSPF This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDE: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 44,782 Btuh, Lat. gain: 7,902 Btuh, Sen. loss: 51,887 Btuh, Entering clg. coil DB: 78.9F, Entering cig. coil WB: 63.8F, Entering htg. coil DB: 58.61F, Clg. coil TD: 20F, Htg. coil TD: 7017, Req. clg. airflow: 1708 CFM, Req. htg. airflow: 580 CFM C:\Users\Julia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Florida Breeze West Melbourne, FL 32904 _ Equipment Data - S stem 5 - Second Floor Cooling System Type: Outdoor Model: Indoor Model: Tradename: Outdoor Manufacturer: Description: AHRI Reference No.: Capacity: Efficiency: Heating System Type: Model: Tradename: Manufacturer: Description: Capacity: Efficiency: Air Source Heat Pump DZ16TC0601C* CA*F4961 *6D*+M13VC2000**-1A*+TX DZ16TC DAIKIN Air Source Heat Pump 202148727 56,500 17 SEER Air Source Heat Pump DZ16TC0601 C* DZ16TC DAIKIN Air Source Heat Pump 59,500 9.5 HSPF Elite Software Development, Inc. Burton 12940 Mack Residence - Page 16 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDE: 75F, SIRH: 50%, WIDE: 70F, Sen. gain: 49,454 Btuh, Lat. gain: 5,623 Btuh, Sen. loss: 43,945 Btuh, Entering clg. coil DB: 76.51F, Entering clg. coil WB: 63F, Entering htg. coil DB: 65.21F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 2097 CFM, Req. htg. airflow: 535 CFM C:IUsers\JulialDropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Florida Breeze West Melbourne, FL 32904 System 9 Room Load Summary- ..------- — ..--- - -- ------ -- Htg Room Area Sens No Name SF Btuh ---Zo -_ ne1--_- - - -- — ___ 1 Guest Living Bed 2,324 40,247 7 And 8 (Blue) Duct Latent Return Duct 9,267 System 1 total 2,324 49,514 System 1 Main Trunk Size: 22 in. Velocity: 507 ft./min Loss per 100 ft.: 0.029 in.wg Cooling System Summa Elite Software Development, Inc. Burton 12940 Mack Residence Page-17 Min Run Run Clg Clg Min Act Htg Duct Duct Sens Lat Clg Sys CFM Size Vel Btuh Btuh CFM CFM 523 13-6 524 29,414 3,968 1,338 1,338 2,470 7,155 1,829 523 36,569 8,267 1,338 1,338 Cooling Sensible/Latent Tons Split Net Required: 3.74 82% / 18% Actual: 4.00 75% / 25% Equipment Data - _- Heating System Type: Air Source Heat Pump Model: DZ16TC0481 C* Indoor Model: Brand: DZ16TC Description: Air Source Heat Pump Efficiency: 9 HSPF Sound: 0 Capacity: 47,000 Btuh Sensible Capacity: n/a Latent Capacity: n/a AHRI Reference No.: n/a I Sensible Latent Total _Btuh - Btuh Btuh 36,669 8,267 44,836 -7 36,000 12,000 10 Y. 48,000 Cooling System Air Source Heat Pump DZ16TC0481C* CA*F4961 *6 D*+M BVC2000**-1 A*+TX DZ16TC Air Source Heat Pump 16 SEER 0 48,000 Btuh 36,000 Btuh 12,000 Btuh 202148839 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDE: 75F, SIRH: 50%, WIDE: 70F, Sen. gain: 36,569 Btuh, Lat. gain: 8,267 Btuh, Sen. loss: 49,514 Btuh, Entering clg. coil DB: 79.91F, Entering clg. coil WB: 64.2F, Entering htg. coil DB: 53.91F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 1338 CFM, Req, htg. airflow: 523 CFM C:IUserslJulia\DropboxlRhvac 9 Projects\BurtonlBurton 12940 Mack Residence.rh9 Monday, March 23, 2020, 149 PM Rhvac - Residential & Light Commercial HVAC Loads Florida Breeze Elite Software Development, Inca West Melbourne, FL 32504 Burton 12940 Mack Residence Page 18 S stem 2 Room Load Summary --,-----._. -_ ------ -._ - - ------ - Htg Min Run Run Clg Clg Min- _ -Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM --- Zone 1--- 2 Living Dining 2,630 40,413 525 15-6 556 35,992 6,557 1,637 1,637 Study Parlor (Green) Duct Latent 3,210 Return Duct 7,069 7,603 2,376 System 2 total 2,630 47,482 525 43,595 12,143 1,637 1,637 System 2 Main Trunk Size: 24 in. Velocity: 521 ft./min Loss per 100 ft.: 0.027 in.wg 0-0 1g, System Summary - - -, Cooling SensiblelLatent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 4.64 78% / 22% 43,595 12,143 55,738 Actual 4.71 75% / 25% 42,375 14,125 t �� 1 �� 56,500 Equipment Data -- - - - - - Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: DZ16TC0601C* DZ16TC0601C* Indoor Model: CA*F4961 *6D*+MBVC2000**-lA*+TX Brand: DZ16TC DZ16TC Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 9.5 HSPF 17 SEER Sound: 0 0 Capacity: 59,500 Btuh 56,500 Btuh Sensible Capacity: n/a 42,375 Stuh Latent Capacity: n/a 14,125 Btuh AHRI Reference No.: n/a 202143727 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODS: 90F, SOWS: 78F, WODB: 42F, SIDE: 75F, S1RH: 50%, WIDB: 70F, Sen. gain: 43,595 Btuh, Lat. gain: 12,143 Btuh, Sen. loss: 47,482 Btuh, Entering clg. coil DB: 792F, Entering cig. coil WB: 63.91F, Entering htg. coil DB: 57.817, Clg. coil TD: 20F, Htg. coil TD: 70F, Req, clg. airflow: 1637 CFM, Req. htg. airflow: 525 CFM C:1Users\Julia\Dropbox\Rhvac 9 ProjectslBurton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 31-49 PM Rhvac - Residential & Light Commercial HVAC Loads Florida Breeze West Melbourne, FL 32904 System 3 Room Load Summary Htg Min Room Area Sens Htg No Name ---Zone 1--- SF Btuh CFM 3 Flex Bed 9 Bed 1,990 36,495 474 10 (Yellow) Duct Latent Return Duct 10,365 System 3 total 1,990 46,860 474 System 3 Main Trunk Size: 20 in. Velocity: 560 ft./min Loss per 100 ft..- 0.040 in.wg Cooling System Summary -- Cooling Sensible/Latent Tons_ - Split Net Required: 3.54 84% / 16% Actual: 4.00 75% / 25% Etc uipment Data Type: Model, - Indoor Model: Brand: Description: Efficiency: Sound: Capacity: Sensible Capacity: Latent Capacity: AHRI Reference No.: Heating S stem Air Source Heat Pump DZ16TC0481C* DZ16TC Air Source Heat Pump 9 HSPF 0 47,000 Btuh nla nla n/a Elite Software Development, Inc.' Burton 12940 Mack Residence _—_..—Page 19 Run Run Clg Clg Duct Duct Sens Lat Size Vel Btuh Btuh 12-6 519 26,867 3,107 2,096 8,799 1,551 35,667 6,754 Min Act Clg Sys CFM-_ CFM 1,222 1,222 1,222 1,222 Sensible - Latent Total. Btuh Btuh Btuh'i 35,667 6,754 T 42,421 y 36,000 12,000 48,000 Cooling System Air Source Heat Pump DZ16TC0481C* CA*F4961 *6D*+MBVC2000**-1A*+TX DZ16TC Air Source Heat Pump 16 SEER 0 48,000 Btuh 36,000 Btuh 12,000 Btuh 202148839 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOW& 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDE: 70F, Sen. gain: 35,667 Btuh, Lat. gain: 6,754 Btuh, Sen. loss: 46,860 Btuh, Entering clg. coil DB: 81.6F, Entering clg. coil WB: 64.7F, Entering htg. coil DB: 50.1 F. Clg. coil TD: 20F, Htg. coil TD, 70F, Req. clg. airflow: 1222 CFM, Req. htg. airflow: 474 CFM C:\Users\Julia\Dropbox\Rhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvae - Residential & Light Commercial HVAC Loads Florida Breeze West Melbourne, FL 32904 System 4 Room Load Summary Htg Min Room Area Sens Htg No Name SF Btuh CFM ---Zone 1--- 4 Kitchen Gym 2,946 44,603 580 Game Bed 3 4 Theater In Law (Pink) Duct Latent Elite Software Development, Inc. Burton 12940 Mack Residence Page 20 Run Run Clg Clg Min Act Duct Duct Sens Lat Clg Sys Size Vel Btuh Btuh CFM CFM 16-6 544 37,544 4,583 1,708 1,708 Return Duct 7,283 7,239 System 4 total 2,946 51,887 580 44,782 System 4 Main Trunk Size: 24 in, Velocity: 544 ft./min Loss per 100 ft,: 0.029 in.wg 1,907 1,412 7,902 1,708 1,708 Coolm Cooling Sensible/Latent - Sensible Latent — - Total Net Required: Tons 4.39 Split 85% / 15% Btuh 44,782 Btuh 7,902 Btuh 52,684 Actual: 4.71 75% / 25% 42,375 14,125 0-7 `/, 56,500 - Equipment Data Heating System - Coolin S stem Type: Air Source Heat Pump Air Source Heat Pump Model: DZ16TC0601 C* DZ16TC0601 C* Indoor Model,- Brand: CA*F4961*6D*+MBVC2000**-W+TX DZ16TC DZ16TC Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 9.5 HSPF 17 SEER Sound: 0 0 Capacity: 59,500 Btuh 56,500 Btuh Sensible Capacity: n/a 42,375 Btuh Latent Capacity: nla 14,125 Btuh AHRI Reference No.: n/a 202148727 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWS: 78F, WODB: 42F, SIDE: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 44,782 Btuh, Lat. gain: 7,902 Btuh, Sen. loss: 51,887 Btuh, Entering cig, coil DB: 78.9F, Entering clg. coil WB: 63.8F, Entering htg. coil DB: 58.6F, Clg. coil TD: 20F, Htg, coif TD: 70F, Req. clg. airflow: 1708 CFM, Req. htg. airflow: 580 CFM C:IUsersWulia\DropboxlRhvac 9 Projects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:49 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Florida Breeze Burton 12940 Mack Residence West Melbourne, FL 32904 _ Page 21 System 5 Room Load Summary Htg Min Run Run Cig Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Cig Sys No Name SF - Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- - - - - - - 5 Second Floor 3,050 41,141 535 20-6 534 46,088 4,667 2,097 2,097 Duct Latent 549 Return Duct 2,804 3,366 407 System 5 total 3,050 43,945 535 49,454 5,623 2,097 2,097 System 5 Main Trunk Size: 26 in. Velocity: 569 ft./min Loss per 100 ft.: 0.029 in.wg Coolin System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Stuh Btuh Btuh Net Required: 4,59 90% / 10% 49,454 5,623 55,077 Actual: 4.71 75% / 25% 42,375 14,125 D�`l� 56,500 Equipment —Data- Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: DZ16TC0601 C* DZ16TC0601 C* Indoor Model: CA*F4961*6D*+MBVC2000**-1A*+TX Brand: DZ16TC DZ16TC Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 9.5 HSPF 17 SEER Sound: 0 0 Capacity: 59,500 Btuh 56,500 Btuh Sensible Capacity: n/a 42,375 Btuh Latent Capacity: n/a 14,125 Btuh AHRI Reference No.: n/a 202148727 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWS: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDE: 70F, Sen. gain: 49,454 Btuh, Lat. gain: 5,623 Btuh, Sen. loss: 43,945 Btuh, Entering clg. coil DB: 76.5F, Entering clg. coil WB: 63F, Entering htg. coil DB: 65.2F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 2097 CFM, Req. htg. airflow: 535 CFM C:IUsers\JulialDropbox\Rhvac 9 Prolects\Burton\Burton 12940 Mack Residence.rh9 Monday, March 23, 2020, 3:50 PM ACCK ® Arc«,doa Gamaa)rsdamac9 County, Town, Municipality, Jurisdiction Header Information Contractor Florida Breeze REQUIRED ATTACHMENTS' Manual Jt Form (and supporting worksheets): Mechanical License # CAC1814113 or MAAE Formz (and supporting worksheets): OEM performance data (heating, cooling, blower): Building Plan # MACK RESIDENCE Sys. 1 Manual D Friction Rate Worksheet: Duct distribution system sketch: Home Address (Street or Lot#, Block, Subdivision) 7840 SADDLEBROOK DRIVE, PSL FL 34986 Design Conditions Winter Design Conditions Outdoor temperature 42 OF Indoor temperature 70 OF Total heat loss 49514 Btu/h Summer Design Conditions Outdoor temperature 90 OF Indoor temperature 75 OF Grains difference 61 A Gr @ 50 % Rh Sensible heat gain 36569 Btu/h Latent heat gain 8267 Btu/h Total heat gain 44836 Btu/h Heating Equipment Data Equipment type Heat pump Furnace, Heat pump, Boiler, etc. Model n71 AYrrnn a1 rr* Form RPER 1.01 8 Mar 10 ATTACHED Yes ❑X No ❑ Yes ❑ Nog Yes ❑X No ❑ Yes ❑ No ❑X Yes ❑ Nolo Building Construction Information Building Orientation (Front door faces) East North, East, West, South, Northeast, Northwest, Southeast, Southwest Number of bedrooms 4 Conditioned floor area 2324 Sq Ft Number of occupants 4 Windows Roof Eave overhang depth 4 7 Ft E— Internal shade Eave Blinds, drapes, etc De th p Window Number of skylights 0 Cooling Equipment Data Equipment type Heat pump Air Conditioner, Heat pump, etc Model n71 ATrnd621 r* Heating output capacity 47000 Btu/h Sensible cooling capacity Heat pumps - capacity at winter design outdoor conditions Auxiliary heat output capacity Design airflow External Static Pressure (ESP) Component Pressure Losses (CPL) Available Static Pressure (ASP) ASP = ESP - CPL Latent cooling capacity Btu/h Total cooling capacity CFM Longest supply duct: IWC Longest return duct: Contractor's Printed Name Kristin Kell Contractor's Signature IWC Total Effective Length (TEL) IWC Friction Rate: Friction Rate = (ASP • 100) . TEL 36000 Btu/h 2000 Btu/h 48000 Btu/h Blower Data Heating CFM 1 998 CFM Cooling CFM 19$ CFM Ft Duct Materials Used (circle) Trunk Duct: Duct board, Flex, Sheet metal, Ft Lined sheet metal, Other (specify) - Ft Branch Duct: Duct board, Flex, Sheet metal, l WC Lined sheet metal, Other (specify) Date 3/23/2020 The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions, Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. ACCK AirCandtiorvv ccrlTaCi0rsdPnaO3 Contractor Florida Breeze Mechanical License # CAC1814113 Building Plan # MACK RESIDENCE County, Town, Municipality, Jurisdiction Header information Sys. 2 REQUIRED ATTACHMENTS' Manual A Form (and supporting worksheets): or MJ1AE Formz (and supporting worksheets): OEM performance data (heating, cooling, blower): Manual D Friction Rate Worksheet: Duct distribution system sketch: Home Address (Street or Lot#, Block, Subdivision) 7840 SADDLEBROOK DRIVE, PSL FL 34986 Desi n Conditions Building Construction Information Winter Design Conditions Outdoor temperature 42 OF Indoor temperature 70 OF Total heat loss 47482 Btu/h Summer Design Conditions Outdoor temperature 90 OF Indoor temperature 75 OF Form RIPER 1.01 8 Mar 10 ATTACHED Yes No ❑ Yes ❑ No ❑X Yes ❑X No ❑ Yes ❑ No ❑X Yes ❑ No Q Building Orientation (Front door faces) East North, East, West, South, Northeast, Northwest, Southeast, Southwest Number of bedrooms Conditioned floor area Number of occupants Windows 4 2630 Sq Ft 1 Grains difference 61 A Gr % Rh @ 50 Eave overhang depth Roof 8.5 Ft Sensible heat gain 43595 I31um Internal shade Latent heat gain 12143 Btulh Blinds, drapes, etc Eave Depth Window Total heat gain 55738 Btulh Number of skylights 0 " • r • '0 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type Fumace, Heat pump Equipment type Heat pump Heating CFM 1998 CFM Heat pump, Boiler, etc, Air Conditioner, Heat pump, etc Model DZ16TC0601C* Model DZ16TC0601C* Cooling CFM 1998 CFM Heating output capacity 59500 Btu/h Sensible cooling capacity 42375 Btulh Heat pumps -capacity at winter design outdoor conditions Latent cooling capacity Btulh 14125 Auxiliary heat output capacity Btu/h Total cooling capacity 56500 Btulh HVAC DUCT DISTRIBUTION•1 Design airflow CFM Longest supply duct: Ft Duct Materials Used (circle) External Static Pressure (ESP) Component Pressure Losses (CPL) Available Static Pressure (ASP) ASP = ESP - CPL Contractor's Printed Name Contractor's Signature Kell IWC Longest return duct: IWC Total Effective Length (TEL) IWC Friction Rate: Friction Rate = (ASP - 100) TEL Trunk Duct: Duct board, Flex, Sheet metal, Ft Lined sheet metal, Other (specify) Ft Branch Duct: Duct board, Flex, Sheet metal, l WC Lined sheet metal, Other (specify) Date 3/23/2020 The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. ' If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. 1� ACCK. Affmd" Ccrtoadns cfnrnai� Contractor Florida Breeze Mechanical License #x CAC1814113 Building Plan # MACK RESIDENCE County, Town, Municipality, Jurisdiction Header Information REQUIRED ATTACHMENTS' Manual J1 Form (and supporting worksheets): or MJ1AE Formz (and supporting worksheets): OEM performance data (heating, cooling, blower): Sys. 3 Manual D Friction Rate Worksheet: Duct distribution system sketch: Home Address (Street or Lot#, Block, Subdivision) 7840 SADDLEBROOK DRIVE, PSL FL 34986 Form RIPER 1.01 8 Mar 10 ATTACHED Yes ❑X No ❑ Yes ❑ No ❑X Yes ❑X No ❑ Yes ❑ No ❑X Yes ❑ No 0 Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature 42 OF Orientation (Front door faces) East Indoor temperature 70 OF North, East, West, South, Northeast, Northwest, Southeast, Southwest Total heat loss 46860 Number of bedrooms Btulh 4 Summer Design Conditions Conditioned floor area 1990 Sq Ft Outdoor temperature 90 OF Number of occupants 2 Indoor temperature 75 OF Windows Grains difference 61 A Gr @ 50 % Rh Eave overhang depth 7.3 Ft Roof Sensible heat gain 35667 Btulh Internal shade F— Latent heat gain 6754 Btulh Blinds, drapes, etc Eave Depth Window Total heat gain 42421 Btulh Number of skylights 0 SELECTIONHVAC EQUIPMENT 4! Heating Equipment Data Cooling Equipment Data Blower Data Equipment type Heat pump Equipment type Heat pump Heating 1998 CFM Furnace, Heat pump, Boiler, etc. Air Conditioner, Heat pump, etc CFM Model DZ16TC0481 C* Model DZ16TC0481 C* Cooling CFM 1998 CFM Heating output capacity 47000 Btu/h Sensible cooling capacity 36000 Btulh Heat pumps- capacity at winter design outdoor conditions Latent cooling capacity Btulh 2000 Auxiliary heat output capacity Btulh Total cooling capacity 48000 Btulh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601A) Design airflow CFM Longest supply duct: Ft Duct Materials Used (circle) Trunk Duct: Duct board, Flex, Sheet metal, External Static Pressure (ESP) IWC Longest return duct: Ft Lined sheet metal, Other (specify) Component Pressure Losses (CPL) Available Static Pressure (ASP) ASP = ESP - CPL Contractor's Printed Name Krl Contractor's Signature IWC Total Effective Length (TEL) IWC Friction Rate: Friction Rate = (ASP K 100) - TFL Ft Branch Duct: Duct board, Flex, Sheet metal, IWC Lined sheet metal, Other (specify) Date nwepr negwreu Hnacnmems prmtea rrom approved A(; ;A sottware vendors, see list on page 2 of instructions. ' if abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. ACCK�. A: cast A*Y8oF,ameim County, Town, Municipality, Jurisdiction Header Information Contractor Florida Breeze Mechanical License # CAC1814113 Building Plan # MACK RESIDENCE Home Address (Street or Lot#, Block, Subdivision) REQUIRED ATTACHMENTS' Manual A Form (and supporting worksheets): or MJ1AE Forme (and supporting worksheets): OEM performance data (heating, cooling, blower) Sys. 4 Manual D Friction Rate Worksheet: Duct distribution system sketch: 7840 SADDLEBROOK DRIVE, PSL FL 34986 HVAC LOAD CALCULATION.1 Design Conditions Buildina Construction Information Form RIPER 1.01 8 Mar 10 ATTACHED Yes 0 No ❑ Yes ❑ No 0 Yes ❑X No ❑ Yes ❑ No X❑ Yes ❑ No X❑ Winter Design Conditions Building Outdoor temperature 42 OF Orientation (Front door faces) East Indoor temperature 70 of North, East, West, South, Northeast, Northwest, Southeast, Southwest Total heat loss 51887 B#ulh Number of bedrooms 4 Summer Design Conditions Conditioned floor area 2946 Sq Ft Outdoor temperature 90 OF Number of occupants 3 Indoor temperature 75 of Windows Grains difference 61 A Gr % Rh � 50 Eave overhang depth Roof 5.8 Ft Sensible heat gain 44782 Btulh Internal shade Eave Latent heat gain 7902 Btulh Blinds, drapes, etc Depth Window Total heat gain 52684 Btu/h Number of skylights 0 HVAC EQUIPMENT SELECTIONfl .Heating Equipment Data Cooling Equipment Data Blower Data Equipment type Heat pump Equipment type Heat pump Heating CFM 1998 CFM Furnace, Heat pump, Boiler, etc. Air Conditioner, Heat pump, etc Model DZ16TC0601 C" Model DZ 16TC0601 C* Cooling CFM 1998 CFM Heating output capacity 59500 Btu/h Sensible cooling capacity 42375 Btulh Heat pumps - capacity at winter design outdoor conditions Latent cooling capacity 412 5 Btulh Auxiliary heat output capacity Btu/h Total cooling capacity 56500 Btulh HVAC DUCT DISTRIBUTION R •1 Design airflow CFM Longest supply duct: Ft Duct Materials Used (circle) Trunk Duct: Duct board, Flex, Sheet metal, External Static Pressure (ESP) IWC Longest return duct: Ft Lined sheet metal, Other (specify) Component Pressure Losses (CPL) IWC Total Effective Length (TEL) Ft Available Static Pressure (ASP) IWC Friction Rate: IWC ASP = ESP - CPL Friction Rate = (ASP x 100) - TEL Contractor's Printed Name Kristin Kelly Contractor's Signature 41, , Branch Duct: Duct board, Flex, Sheet metal, Lined sheet metal, Other (specify) Date 3/23/2020 The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. ' If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. //j�arr ACCK. AirCun*On gccu�,saa„ai� County, Town, Municipality, Jurisdiction Header Information Contractor Florida Breeze Mechanical License # CAC1814113 Building Plan # MACK RESIDENCE Home Address (Street or Lot#, Block, Subdivision) Design Conditions Winter Design Conditions Outdoor temperature 42 Indoor temperature 70 Total heat loss 43945 Summer Design Conditions Outdoor temperature 90 REQUIRED ATTACHMENTS' Manual J1 Form (and supporting worksheets): or MJ1AE Form' (and supporting worksheets): OEM performance data (heating, cooling, blower): Sys. 5 Manual D Friction Rate Worksheet: Duct distribution system sketch: 7840 SADDLEBROOK DRIVE, PSL FL 34986 Me Form RIPER 1.01 8 Mar 10 ATTACHED Yes ❑X No ❑ Yes ❑ No 0 Yes 0 No ❑ Yes ❑ No N Yes ❑ No ❑X Building Construction Information Building OF Orientation (Front door faces) East OF North, East, West, South, Northeast, Northwest, Southeast, Southwest Btulh Number of bedrooms 4 Conditioned floor area 3050 Sq Ft OF Number of occupants 4 Indoor temperature 75 aF Windows Grains difference 6 � 0 Gr % Rh @ 50 Eave overhang depth Roof 2.6 Ft Sensible heat gain 49454 Btu/h Internal shade Latent heat gain 5623 Btulh Blinds, drapes, etc Eave Depth Window Total heat gain 55077 Btulh Number of skylights 0 IHVAC• 41 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type Heat pump Equipment type Heat pump Heating CFM 1998 CFM Furnace, Heat pump, Boiler, etc. Air Conditioner, Heat pump, etc _ Model DZ16TC0601 C* Model DZ16TC0601 C* Cooling CFM 1998 CFM Heating output capacity 59500 Btulh Sensible cooling capacity 42375 l3tulh Heat pumps - capacity at winter design outdoor conditions Latent cooling capacity Btulh 1412 5 Auxiliary heat output capacity Btulh Total cooling capacity 56500 Btulh �HVAC DUCT DISTRIBUTION SYSTEM i .1 Design airflow CFM Longest supply duct: Ft Duct Materials Used (circle) Trunk Duct: Duct board, Flex, Sheet metal, External Static Pressure (ESP) IWC Longest return duct: Ft Lined sheet metal, Other (specify) Component Pressure Losses (CPL) IWC Total Effective Length (TEL) Available Static Pressure (ASP) IWC Friction Rate: ASP = ESP - CPL Friction Rate = (ASP x 100) W TEL Contractor's Printed Name Contractor's Signature Kristi — Ft Branch Duct: Duct board, Flex, Sheet metal, IWC Lined sheet metal, Other (specify) The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. ' If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program.