HomeMy WebLinkAboutEngineering-UPDATEDFLORIDA BUILDING CODE 2017, 6th EDITION DESIGN PRESSURE FOR OPENINGS Version 10.0 —-�-----�_-- _ ow DESIGN PRESSURES FOR WALL COMPONENTS & CLADDING Design Data Building Data Wind Velocity (mph) 160 Mean Roof Height 22 Risk Category 2 Building Width (ft) 70 Exposure Category D Building Length (ft) 138 Directionality Factor 0.85 Roof Slope (x:12) 5 Internal Pressure Coefficient +/- 0.18 5 Design pressures listed below are: Allowable Stress OPENING MARK OPENING DESCRIPTION LOCATION ZONE OPENING ELEVATION OPENING DIMENSIONS MAXIMUM POSITIVE WIDTH (INCHES) HEIGHT (INCHES) PERSSURE (PSF) MAXIMUM NEGATIVE PRESSURE (PSF) 1 BED 5 0 120 80 36.0 -47.4 2 BED 5 5 48 24 41.1 -58.2 3 BED 5 5 48 24 41.1 -58.2 4 BED 5 5 48 24 41.1 -58.2 5 BED 5 5 48 24 41.1 -58.2 6 FAM 5 5 48 60 39.2 -54.2 7 FAM 5 5 48 41.1 -58.2 Homeowner.- omeowner:Lee Hood Lee 4949 N HighwayA1A Fort Pierce, FL 34949 Contractor: The Home Depot 2455 Paces ferry Road Atlanta, GA 30339 ..S__ ---e, - (g�aA) STRUCTURES INTERNATIONAL, LLC pswdrq spa 2aM* to , Protce * Width of End Zone (a) in feet = 7 Lildon Engineering Company, Inc. r r .. 920 Sunsef Shores Dr. • •��.A;,B��c •• Minneola, Florida 34715 �•�P,.���GENSF''•.�i-'� (352) 394-2590 Ph.& FAX No. 52583 Cert. Ruth. #2898 STATE OF ••;AoF �20R��P'���� � • '•:SSIONA\-��.•' ••r.rr►rr March. 19, 2020 Wayn A. Block, PE#52583