HomeMy WebLinkAboutProduct Approvals (2)Florida Building Code Online
Page 1 of 3
Comments
Archived
i....
Product Manufacturer
Janus International Group, LLC.
Address/Phone/Email
135 Janus International Blvd.
Temple, GA 30179
(770) 562-6135 Ext 360
curts@janusintl.com
Authorized Signature Curtis Schroeder
curts@janusintl.com
Technical Representative Scott Robillard
Address/Phone/Email 135 Janus International Blvd
Temple, GA 30179
(770) 562-2850
scott.robillard@janusinti.com
Quality Assurance Representative Chris Meyer
Address/Phone/Email 135 Janus International Blvd
Temple, GA 30179
(770) 562-2850
chris.meyer@janusintl.com
Category Exterior Doors
Subcategory Roll -Up Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
I__, Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed John E. Scates
the Evaluation Report
Florida License PE -51737
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Gordon Thomas, P.E.
W Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL21450 R3 COI Cert of Ind 2019 s.pdf
Standard
ANSI/DASMA 108
ANSI/DASMA 115
ASTM E330
Year
2012
2012
2002
http://www.floridabuilding.org/pr/Pj _app_dtl.aspx?param=wGEVXQwtDgtgHSolOoKvo5... 4/14/2020
Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted
08/16/2019
Date Validated
08/16/2019
Date Pending FBC Approval
08/19/2019
Date Approved
10/15/2019
Date Revised
04/07/2020
Page 2 of 3
Summary of Products
FL # Model, Number or Name Description
21450.1 Series 1100 Series 1100 - 26 Gauge Door Assembly Max Size: 8'-8" x
14'-0"
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +24.4/-27.0
Other: Not for use in High Velocity Hurricane Zones
Installation Instructions
FL21450 R3 II 1100 T1012 RevC s.pdf
Verified By: John E. Scates PE -51737
Created by Independent Third Party: No
Evaluation Reports
FL21450 R3 AE EvalRept Model750 1100 rl s.pdF
Created by Independent Third Party: Yes
--j
21450.2
Series 1100
Series 1100 - 26 Gauge Door Assembly Max Size: 10'-0" x
14'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21450 R3 II 1100 T1013 RevC s..df
Approved for use outside HVHZ: Yes
Verified By: John E. Scates PE -51737
Impact Resistant: No
Created by Independent Third Party: No
Design Pressure: +19.4/-22.7
Evaluation Reports
Other:
FL21450 R3 AE EvalRept Modei750 1100 rl s.odf
Created by Independent Third Party: Yes
Other:
21450.3
Series 3100
Series 3100 - 26 Gauge Door Assembly Max Size: 20'-0" x
20'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21450 R3 II T1015 RevB s.pdf
Approved for use outside HVHZ: Yes
Verified By: John Scates FL -51737
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +40/-40
Evaluation Reports
Other:
FL21450 R3 AE EvalRept Model3100-IM r1 s.pdf
Created by Independent Third Party: Yes
21450.4
Series 3100
Series 3100 - 26 Gauge Door Assembly Max Size: 20'-0" x
20'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21450 R3 II T1016 Rev- s.odf
Approved for use outside HVHZ: Yes
Verified By: John Scates FL -51737
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +42.5/-45
Evaluation Reports
Other:
FL21450 R3 AE EvalReot Mode13100-IM rl s.odf
Created by Independent Third Party: Yes
21450.5
Series 3100 -IM
Series 3100 -IM - Impact Resistant 26 Gauge Door Assembly
Max Size: 16'-0" x 20'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21450 R3 II T1016 Rev- s.pdf
Approved for use outside HVHZ: Yes
Verified By: John Scates FL -51737
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +42.5/-45
Evaluation Reports
Other:
FL21450 R3 AE EvalRept Mode13100-IM rl s.odf
Created by Independent Third Party: Yes
21450.6
Series 3100 -IM
Series 3100 -IM - Impact Resistant 26 Gauge Door Assembly
Max Size: 14'-0" x 20'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL21450 R3 II T1015 RevB s.pdf
Approved for use outside HVHZ: Yes
Verified By: John Scates FL -51737
Impact Resistant: Yes
Created by Independent Third Party: Yes
Design Pressure: +40/-40
Evaluation Reports
Other:
FL21450_R3_AE EvaiRept Model3100-IM rl s.pdf
Created by Independent Third Party: Yes
21450.7 1 Series 750
http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgtgHSolOoKvoS... 4/14/2020