HomeMy WebLinkAbout01) floor plan - signed, updated (2)BUILDING DEPARTMENT PRODUCT APPROVAL SUBMITTAL AFFIDAVIT OPENING SCHEDULE: SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS @ SKYLIGHTS: PRODUCT MODEL " MANUFACTURER ATTACHMENT METHOD TYPE, SIZE, SPACING 4 EMBEDMENT BUILDING DESIGN PRESSURE EXPIR, DATE APPROVALr EVALUATION AGENCY PRODUCT DESIGN PRESSURE BI -FOLD EXT, GLASS DRS, (OUTSWING) "EURO -C3" ALUM. (L.M,I, IMPACT) EURO -WALL SYSTEMS (SEE MANUFACTURERS SPECS.) +42,4 / -56,1 +100.0 / -100,0 N/A FL 11838,1 MIAMI /DADE FRENCH DOOR (FIBERGLASS) FD -150 (IMPACT) PGT+42,4 I/4" x 2 3/4" TAPCONS / 012 NEAR / -56,1 / +10,0 -50,0 02/24/2020 16-0629,16 MIAMI /DADE BUILDING DATA 4 DESIGN PRESSURE SCHEDULE PROJECT/NAME ZIVNEY RESIDENCE ARCHITECT M,A, CORSON 8 ADDRESS: 1 11 0o ASSOCIATES, INC, I ALL PRESSURES CALCULATED WITH THE FOLLOWING: I. WIND LOADS BASED ON F.B.C, 2011 (6TH ED.) 8, WALL ZONE (f -SF): 4) +42,4 / -46.0 t ASCE 1-10, AND N,E.G, 2014 5) +42.4 / -56,1 2. BUILDING DESIGNED AS: ENCLOSED OPEN 9, GARAGE DOOR (PSF): +36.8 / -40.4 3, MEAN BUILDING HEIGHT: 24 FT. ROOF PITCH: 6 /12 10. LOADS: FLOOR 60 PSF INTERNAL PRESSURE COEFICIENT +/- : 0.18 ROOF/DEAD 15 PSF ROOF LIVE 30 PSF 4, WIDTH OF END ZONE: 4' 11, SHEAR WALLS CONSIDERED FOR STRUCTURE? WIND SPEED: ALT, 110 MPH 3 SECOND GUST - YES X NO NOMINAL: 132 MPH 12, CONTINUOUS LOAD PATH PROVIDED? 5, BUILDING CLASSIFIGAT0 TABLE 1-I, ASCE 1_ YES X NO F.B.C. TABLE 1604,5 13, ARE COMPONENT 6 CLADDING DETAILS PROVIDED? 6, EXPOSURE CATEGORY: G ADJUSTMENT FACTOR: 1,45 YES X NO 1, COMPONENTS E CLADDING WIND PRESSURE ON: 14, SOIL BEARING CAPACITY: 2500 PSF ROOF ZONE (PSF): U +24.5 / -38,9 PRESUMPTIVE:_ BY TEST: X 2) +24.5 / -(b1.8 3) +24.5 / -132.8 15. TYPE CONSTRUCTION (TABLE 601) IIB ALL ZONES CALCULATED FOR WORST CASE SCENARIO. (10 S,F, EFFECTIVE WIND AREA) GENERAL ADDITION NOTES: *THE DETAILS CONTAINED PER THESE PLANS MAY NOT BE EXACT AND SHALL BE VERIFIED PRIOR TO ANY CONSTRUCTION BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR). *OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING CONSTRUCTION, *EXISTING CONDITIONS ON ADDITIONS/RENOVATIONS ARE TO BE VERIFIED BY OWNER AND/OR CONTRACTOR (SUB -CONTRACTOR) EXAMPLE: EXISTING SOFFIT MATERIALS, EXTERIOR FINISHES, TRIM MATERIALS, ROOFING MATERIALS, FASCIAS, ETC, *OWNER AND/OR CONTRACTOR (SUB-GONTRAGTOR) IS RESPONSIBLE FOR PROVIDING AND VERIFYING DESIGN GUIDELINES AND RESTRICTIONS PER SUBDIVISIONS ARCHITECTURAL REVIEW BOARD. *M,A, CORSON 4,4850C. INC, SHALL NOT BE LIABLE FOR ANY LOSS, DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES, SQUARE FOOTAGE CALCULATIONS TOTAL A/C AREA 4,945 SQ, FT, GARAGE 820 SQ, FT, NEW COVERED ENTRY 15 SQ, FT, TOTAL NON A/C AREA 995 SQ, FT, TOTAL AREA 5,940 SQ, FT, CONTRACTORS TO VERIFY ALL SQUARE FOOTAGES LOT AREA = 29,354 S.F. WALL LEGEND 18" LONG #3 DOWELS Q 24" O,G, on ea, SIDE STAGGERED x TRENCH WIDTH, DRILL 4 EPDXY 6" INTO EDGE OF EXIST, SLAB MID -DEPTH, *3 BAR GONT, 6 MIL, VAPOR BARRIER ON j� GRADE COMPACTED 6 TREATED FILL. -S� O GRADE PA �L �1.iH 3/411=1l 910"1 NOTE: SLAB PATCH FOR MECHANICAL TRENCHES - MATCH J� EXISTING THICKNESS BUT NOT LESS THAN 4" SLIDING GLASS DOOR ATTACHMENT lx3 F, 7' WOOD BUCK lNS 7ALLA7/0N 1/4" TAPCONS m 16" O.G. MAX. d WITHIN 6" OF CORNERS OR PER DOOR MANUF. ATTACH THRU FRAME AND BUGK INTO BLOCK W/ 1 1/4" MIN. PENETRATION INTO BLOCK WALL 2x4 P.T. U//OOD BUCK 70 CONC, I/ 'X2 3/4" TAPCONS w 12" O.C. t WITHIN 6" OF CORNERS DOOR FRAMP TO 2x F.T BUCK: SILL: 1 - "10 x 1 1/2" PH CP SMS CENTERED AT6" FROM JAMB, R HEADES: 8 - 1/4" x 1 1/2" LAG SCREWS CENTERED AT 6" FROM JAMS, JAMBS: 5 - 1/4" x 1 1/2" LAG SCREWS CENTERED AT 6" FROM HEAD AND SILL. HOLLOW 8 HATCHED = EXISTING WALL TO REMAIN SOLID = NEW WALLS DASHED = EXISTING WALL TO BE REMOVED IR 41- 6 () 6 0 U Z N Z N N Z > 0o 0 N 4 M M Q) z� 3: zL O- � N x Z -c c 0 ' O U�-c- I) (K T o Q) O I Q N o 1 Q 3 S N • z 0=4 Z aso 0-4V V PC M v ProrA o V1 I� cc N °0 4-1 PC 4 OO O IN rA rA � U O DATE : 03106120 DRAWN BY: pJ9 me CHECKED Mc REVISIONS