Loading...
HomeMy WebLinkAbout5380-F85FB-v20.0 - Sheet - A2 - REFLECTED CEILING PLANOS OS M OS M OS M M M M M M OS M OS M M OS 1 2 3 7 7.8 8 F 3 A6.2 3 A6.1 1 A6 1 A6.2 2 A6 2 A6.1 1 A5 2 A5 E 1 A6.1 4 A6.2 LIGHTING @ TOWER SOFFIT ABOVE D A.F.F. 2' X 2' ACT2 10' - 0" A.F.F. INSULATED PANEL 9' - 0" A.F.F. 2' X 2' ACT2 10' - 0" A.F.F. INSULATED PANEL 9' - 0" A.F.F. INSULATED PANEL 9' - 0" 2' - 0"2' - 6"2' - 4 1/2"A.F.F. INSULATED PANEL 9' - 0" DS DS DS STUCCO FINISH WALL LIGHTS RE: ELECTRICAL LINE OF SOFFIT ABOVE RE: 2/A21' - 11"A.F.F. 5/8" MR GWB 10' - 0" A.F.F. 5/8" MR GWB 8' - 6" SEE NOTE 5 A.F.F. 5/8" MR GWB 10' - 0" SEE NOTE 5 A.F.F. 5/8" MR GWB 10' - 0" SEE NOTE 5 10' - 0 5/8" 5' - 6"5' - 6" DS DS DS TROUGH ABOVE. RE: ELECTRICAL DWGS PENDANT LIGHT, ALIGN W/ CABINET BELOW AS SHOWN. BOT, @ 8'-0" A.F.F. EXTERIOR EMERGENCY LIGHT CENTERED ABOVE DOORWAY EXTERIOR EMERGENCY LIGHT CENTERED ABOVE DOORWAY CREATE 2' X 3' ACCESS FOR WALK-INS 6" ABOVE THE CEILING IN THIS AREA. FROM BLDG CENTERLINE TO CENTERLINE OF SOFFIT 20' - 2" BUILDING CENTERLINES. RE: SHEET A1 M CENTER FIXTURE OVER LAVATORY (TYP) RECESSED DOWNLIGHT, TYP RE: ELECTRICAL CENTERLINE OF FOOD SERVICE COUNTER BELOW 2 A9.1 3' - 4"EQEQEX EX EX COMPLETELY SEAL PERIMETER OF CEILING CREATE 2' X 3' ACCESS FOR WALK-INS 6" ABOVE THE CEILING IN THIS AREA EF SECURITY CAMERA, TYP RE: ELECTRICALSECURITY CAMERA, TYP RE: ELECTRICAL DS DS 6' - 0"2' - 4"9' - 6"10' - 0"10' - 0"10' - 0"24"X30" ACCESS PANEL RE: DOOR SCHEDULE AP4 EVAPORATORS, TYP SECURITY CAMERAS RE: ELECTRICAL VESTIBULE 1 OFFICE 5 ASSOCIATE 19 WATER SERVICE ROOM 20 WOMEN'S RESTROOM 23 STAGING 16 9 3/4"4' - 10"10' - 1"9' - 9" ALL MUSIC SPEAKERS AND OCCUPANCY SENSORS CENTERED IN CEILING TILE U.N.O. (TYP.) 1' - 6"0"1' - 10"PROVIDE ARMSTRONG #7808 ANGLE MOLDING AT STONE. DS (RE: NOTE 5) 9 A9 6' - 4" DUPLEX OUTLET DUPLEX OUTLET 2' - 11" MR GWB ON 8" 16-GA. METAL STUDS AT 24" O.C. TYP AT MEN'S & WOMEN'S RESTOOMS AIR CURTAIN 1' - 6"16 A7 PROVIDE 3/4" PLYWOOD DECK OVER RESTROOM CEILING JOISTS. AT MEN'S & WOMEN'S RESTOOMS DOWNLIGHT, CENTERED IN PANEL. 4 A5 10' - 0"10' - 0"3' - 5"2' - 6"6' - 1" +/- 2' - 2" UN-VENTED SOFFIT THIS AREA A.F.F. 5/8" MR GWB 13' - 6" SEE NOTE 5 C B A 3.5 4 5 6 P1 P1 P1 P1 1' - 6" ACOUSTICAL CEILING CONTINUES ABOVE SOFFIT A2 4 LED STRIP LL2 10 A2 SEE 4/A2 AND 3/A2 FOR PLAN LAYOUT OF SOFFIT ABOVE 1 A9.1 1' - 0"1' - 7"1' - 9"1' - 9"1' - 0"9"P6 1' - 0" EQ EQ EQ EQRETAIL WALK-IN REFRIG. 37 SELF SERVICE WALK-IN REFRIG. 38 REAR VESTIBULE 34 P1 EF WALK-IN FREEZER 28 WALK-IN REFRIG. 29 3' - 4"2' - 0" 2' - 0" 5/8" MR GWB, 3-5/8" MTL. FRAMING 9'-0" A.F.F. RECESSED DOWN LIGHTING IN GWB SOFFIT. (TYP.)3' - 0"3' - 0"2' - 11 1/2"2' - 11 1/2" EQ EQ EQ EQ EF EF EQ EQCOFFEE COUNTER BELOW2' - 2"A2 3 4' - 0"4' - 0"2' - 11"1' - 7" 1' - 10"2' - 10"4' - 0"4' - 0"RETAIL AREA 35 DELIVERY VESTIBULE 36 MEN'S RESTROOM 24 ELECTRICAL ROOM 39 FOOD SERVICE 32 COFFEE 33 A.F.F. 2' X 2' ACT1 13' - 6" WASH ROOM 31 3' - 7"3' - 6 1/2"6' - 5"5' - 0 1/2"A.F.F. 2' X 2' ACT1 10' - 0" A.F.F. 2' X 2' ACT2 10' - 0" A.F.F. 2' X 2' ACT2 11' - 0" EXTERIOR EMERGENCY LIGHT CENTERED ABOVE DOORWAY EX 5 A2 WALL MTD SIGN RE: SHEET G1 6 A2 8 A2 3 A9.1 10 A2 A.F.F. 2' X 2' ACT1 10' - 6" 7 A2 7 A2 2' - 0" 2' - 0" A.F.F. 2' X 2' ACT1 10' - 6" A.F.F. 2' X 2' ACT1 10' - 6" A.F.F. 2' X 2' ACT1 10' - 6" A.F.F. 2' X 2' ACT1 10' - 6" A.F.F. 2' X 2' ACT1 10' - 6" 4' - 0"4' - 0"4' - 0"4' - 0"4' - 0"4' - 0" 3' - 8 1/2"10"A9.2 1 6' - 4"3' - 0"3' - 0"4' - 0"1' - 1 1/2"1' - 7 1/2"3' - 4" 1' - 0 1/2"3' - 9" 3' - 0"3' - 5"1' - 3"2' - 2"7 1/2"EX 1' - 2"1' - 2"4' - 0"4' - 0"EVAPORATORS, TYP EVAPORATORS, TYP 3' - 8 1/2" EVAPORATOR EX A.F.F. 2' X 2' ACT1 9' - 0" A.F.F. 2' X 2' ACT1 9' - 0" A.F.F. 2' X 2' ACT1 13' - 6" B.O. SOFFIT @ 8'-0" B.O. SOFFIT @ 9'-0"EQEQ3' - 2"3' - 2" 2' - 4"2' - 4"EQEQ1' - 0"1' - 6"3' - 1 1/2"3' - 1 1/2"A.F.F. 5/8" MR GWB 8' - 6" SEE NOTE 5 CENTER FIXTURES OVER LAVATORIES (TYP) P6 6' - 3"1' - 6"1' - 0"2' - 5"3' - 5"3' - 5"1' - 4 1/2"1' - 0"G 2' - 0"TO UNDERSIDE OF DECK ABOVE 1/2" M.R. GWB, FLUSH W/ FACE OF WALK-IN BOX CONTRUCTION ADHESIVE FRP EDGE MOLDING DELIVERYWALK-IN BOX FRP, RUN PAST JOINT @ TOP OF WALK-IN SEALANT 3-5/8" MTL STUDS AND CONTINUOUS BOTTOM TRACK CONT. LED LIGHTING @ TOWER SOFFIT. RE: ELECTRICAL INSIDE OF TOWERO.H.2' - 0"GUTTER, TYP DOWNSPOUT, TYP O.H. 2' - 0" PANEL SOFFIT (TYP.) OPEN STRUCTURE 1/2" M.R. GWB, BOTH SIDES 3-5/8" MTL STUDS AND CONTINUOUS BOTTOM TRACK FRP ACOUSTICAL CEILING TILE AS SCHEDULED ACOUSTICAL CEILING TILE AS SCHEDULED SCHLUTER QUADEC TILE AS SCHEDULED 6"BOTT. OF FINISH 9' -0"A.F.F. UNDER SOFFIT P1 4-WAY DIFFUSER 3-WAY DIFFUSER 2-WAY DIFFUSER 2-WAY DIFFUSER 1-WAY DIFFUSER VERIFY DIFFUSER TYPE WITH HVAC PLAN SHEET M1. REFER TO MECHANICAL SHEETS FOR MORE INFORMATION. RETURN LINEAR DIFFUSER EF EXHAUST INTERIOR FINISH TAG RE: SHEET A8 FOR FINISH SCHEDULE P1 2 X 4 LED FIXTURE 2 X 2 LED FIXTURE 2 X 2 EMERGENCY LED FIXTURE 2 X 4 EMERGENCY LED FIXTURE B.O. CHASE CLG HT. RE: RCP T.O. CHASE 4-SIDED 3/4" PLYWD CHASE FOR SODA LINES. 8"X8" MIN. CLEAR INSIDE DIMENSION. FASTEN TO WALL 8" FRP FINISH ALL EXPOSED SURFACES ACOUSTICAL CEILING TILE 1' - 0"6"P1 PROFILE AT WALK- IN REFRIGERATOR UNDER SOFFIT INTERIOR FASCIA FRAMING. RE: STRUCTURAL ACT CLG 13' -6"A.F.F. B.O. SOFFIT 7' -1"A.F.F. GWB CLG 9' -0"A.F.F. ACOUSTICAL CLG TILE 1' - 0"GLASS TILE OVER M.R. GWB ON 3-5/8" MTL STUDS @ 16" O.C. 1' - 4" 5/8" GWB ON 3-5/8" MTL STUDS @ 12" O.C. PAINTED GWB. RE: ELEVATIONS 1X4 WOOD CEILING TRIM. 6" LED STRIP LIGHT MOUNTED ON TILTABLE STAND. ADJUST ANGLE IN FIELD TO DIRECT LIGHT ONTO WALL. RE: ELECTRICAL 2"2X6 BLOCKING AT MOUNTING ANGLE LETTER LOGO SIGN IN SUPPORT TUBES BY SIGN VENDOR CO. A9 10 RECESSED DOWNLIGHTING IN GWB SOFFIT.10 1/2"4' - 0"4' - 0"4' - 0"8"4' - 0"4' - 0" 8" 10' - 5"14' - 3"8"10 A2 DL3 4-IN. DOWNLIGHT, TO BE LOCATED IN THE GWB SOFFIT, TYP. RE: ELECTRICAL LL2 LED STRIP LIGHT, TYP., TO BE MOUNTED ON TOP OF SOFFIT, ON TILTABLE STAND. DIRECT TOWARD WALL. RE: ELECTRICAL 6"6"DL3 4-IN. DOWNLIGHT, TO BE LOCATED IN THE GWB SOFFIT, TYP. RE: ELECTRICAL LL2 LED STRIP LIGHT, TYP., TO BE MOUNTED ON TOP OF SOFFIT, ON TILTABLE STAND. DIRECT TOWARD WALL. RE: ELECTRICAL NOTE:REF SHEET E2 FOR LIGHTING INFORMATION. 1 A9.11' - 9"1' - 9"4' - 0"4' - 0"2' - 7 1/2"3' - 6"10"CEILING HEIGHT B.O. SOFFIT 1" CORNER GUARD 1/2" LEVEL 5 GWB, BOTH SIDES 3-5/8" MTL STUDS AND CONTINUOUS BOTTOM TRACK SOFFIT AT EXPRESS CASE 7' - 4" 9' - 0" WOOD VENEER BY WAWA B.O. SOFFIT WALK-IN REFRIGERATOR INTERIOR FASCIA FRAMING. RE: STRUCTURAL HOLD 1/2" GAP BETWEEN STUDS AND WALK-IN UNIT UNDER SOFFIT P1 1/2" GWB ON 3-5/8" MTL STUDS 1/2" 7' - 1"SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © - All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service prepared by: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.4/16/2020 12:05:56 PMA2218071904-17-2020S.G.A.D.M.REFLECTED CEILING PLANORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA F85FB 2020.00 STORE #5380-ORN04/17/2020 1/4" = 1'-0"A2 1 REFLECTED CEILING PLAN 1 1/2" = 1'-0"A2 8 FASCIA AT WALK-IN REFRIGERATOR AT DELIVERY 1/8" = 1'-0"A2 2 UPPER TOWER REFL. CEILING PLAN 1 1/2" = 1'-0"A2 7 FASCIA/SOFFIT AT FOOD SERVICE 1. REFER TO SHEET "E2" FOR LIGHTING INFORMATION. 2. G.C. SHALL INSTALL 3/4" 1/4-ROUND MOLDING TO COMPLETELY SEAL THE GAP BETWEEN THE SOFFIT WALL AND WALK-IN REFRIGERATOR. PAINT MOULDING COLOR BLACK. MITER CUT AT RAW ENDS (TYP.) 3. NOT USED. 4. ANY EXPOSED GWB CEILINGS SHALL BE PAINTED COLOR MUSLIN. 5. GWB CEILING CONSTRUCTION : 8" , 16 GA. METAL STUDS @ 24" O.C., INSULATED, U.N.O. 6. REFER TO SHEET "M1" FOR AIR DIFFUSERS AND RETURN AIR GRILLES INFORMATION. 7. NO ACCESS PANELS IN FREEZERS. 8. REFER TO INTERIOR FINISH SCHEDULE, SHEET A8, FOR CEILING SPECIFICATIONS. 9. ALL SOFFIT CONDITIONS SHALL BE CONSTRUCTED WITH METAL STUDS @ 16" O.C. M MUSIC SYSTEM SPEAKER M WALL MOUNTED MUSIC SYSTEM SPEAKER GENERAL NOTES 1 1/2" = 1'-0"A2 9 SODA CHASE DETAIL 3/4" = 1'-0"A2 10 PERIMETER FASCIA DETAIL REFLECTED CEILING PLAN LEGEND 1/4" = 1'-0"A2 3 PLAN @ RETAIL SOFFIT 1/4" = 1'-0"A2 4 SOFFIT @ SELF-SERVE BEVERAGE AREA OS OCCUPANCY SENSOR 1/2" = 1'-0"A2 5 SOFFIT AT EXPRESS CASE ALCOVE 3/4" = 1'-0"A2 6 FASCIA/SOFFIT AT SELF-SERVE REF. 2 X 2 ATC CEILING GWB CEILING Revision ScheduleNo.DescriptionDatePERMIT SET04/17/2020