Loading...
HomeMy WebLinkAbout5380-F85FB-v20.0 - Sheet - A6 - WALL SECTIONS AND DETAILST.O. FLOOR SLAB 0' -0" T.O. FLOOR SLAB 0' -0" B.O. OVERHANG 9' -0" TOWER BRG. 26' -10" TOWER PEAK 33' -4" T.O. CLERESTORY 13' -6" 2 A6 SIGN, BY SIGN CONTRACTOR STANDING SEAM METAL ROOF. RE: A4 EXTERIOR FINISH SCHEDULE GUTTER, PERIMETER OF FASCIA 5/8" EXTERIOR GRADE FIRE RESISTANT PLYWOOD SHEATHING AT ENTIRE WALL SURFACE BEHIND SIGN 7/8" STUCCO FINISH OVER 3.4# SELF-FURRING GALVANIZED METAL LATH OVER ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8" EXTERIOR GRADE PLYWOOD SHEATHING 8" METAL STUD, TYP RE: STRUCTURAL SINGLE PLY ROOFING SYSTEM OVER RIGID INSULATION (TYP.) RE: ROOF PLAN, SHEET A3 36" X 48" ACCESS HATCH. RE: DOOR SCHEDULE PRE-ENGINEERED ROOF TRUSS FRAMING. RE: STRUCTURAL 5/8" EXTERIOR GRADE PLYWOOD 7/8" STUCCO FINISH OVER 3.4# SELF-FURRING GALVANIZED METAL LATH OVER ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8" EXTERIOR GRADE PLYWOOD SHEATHING 8" METAL STUD. RE: STRUCTURAL BATT INSULATION RECESSED LIGHTING RE: ELECTRICAL 7/8" STUCCO FINISH OVER 3.4# SELF- FURRING GALVANIZED METAL LATH OVER ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8”EXTERIOR GRADE PLYWOOD SHEATHING, BEYOND. RE: EXTERIOR ELEVATIONS EXTERIOR LIGHT FIXTURE. FIXTURE SHALL BE SECURED AGAINST MOVEMENT/ ROTATION. RE: ELECTRICAL ADHERED MANUFACTURED STONE VENEER BEYOND PRE-CAST ADHERED MFD STONE WATERTABLE/SILL BEYOND SUSPENDED ACOUSTICAL TILE CEILING STOREFRONT SYSTEM STEEL JOIST. RE: STRUCTURAL CONCRETE SLAB, RE: STRUCTURAL TERRAZZO FLOOR FINISH STOREFRONT SYSTEM 1/2" EXPANSION JOINT W / SEALANT, TYP PREFINISHED BRAKE METAL OVER ONE LAYER HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER. BRAKE METAL TO MATCH STOREFRONT TUBE STEEL BEAM. RE: STRUCTURAL 5/8" PLYWOOD OVER RIGID INSULATION RE: ROOF PLAN, SHEET A3 WHITE STUCCO BAND BEYOND 5/8" EXTERIOR GRADE F.R.T. PLYWOOD. CONT. AT TOWER INTERIOR UP TO 48" ABOVE DECK T.O. MULLION & SILL 3' -0" 5/8" M.R. GWB CEILING AP5 RAINSHIELD 8"A6 3 25 A9 A6 5 6" 12" A3.1 1 8" 16-GA. MTL. STUDS@ 24" O.C. VESTIBULE 1 COORDINATE SIGNAGE BLOCKING PER MFR'S REQUIREMENTS INSULATE VOIDS AT BEAMS A5 5 CBA STEEL TUBE RE: STRUCTURAL HEADER RE: STRUCTURAL 8" MTL FRAMING HEADER RE: STRUCTURAL SPRAY-FOAM SEAL ALL STEEL PENETRATIONS THROUGH ROOF DECK (TYP.) EXIT SIGN KNOX BOX B.O. CLERESTORY 11' -0"1' - 6"T.O. FLOOR SLAB 0' -0" JST. BRG. FRONT 17' -10" B.O. OVERHANG 9' -0" TOWER BRG. 26' -10" TOWER PEAK 33' -4" 1 A6 36" X 48" ACCESS DOOR. RE: DOOR SCHEDULE V2 5/8" EXTERIOR GRADE F.R.T. PLYWOOD CONT AT TOWER INTERIOR UP TO 48" ABOVE DECK T.O. MULLION & SILL 3' -0" 5/8" M.R. GWB CEILING AP5 A9 25 6" 12" A4 8 29 A7 8" 16-GA. MTL. STUDS@ 24" O.C. 28 A7 VESTIBULE 1 A3.1 1 A5 6 STEEL BEAM RE: STRUCTURAL INSULATE VOIDS AT BEAM GWB TO UNDERSIDE OF DECK (TYP.) ALL EXT. WALLS SPRAY ALL VOIDS WITH FOAM SEALANT PORCH OVERHANGSTOREFRONT ADHERED MANUFACTURED STONE VENEER 1/2" EXPANSION JOINT W / SEALANT (TYP) 4 5 6 5/8" PLYWOOD OVER RIGID INSULATION RE: ROOF PLAN, SHEET A3 CONCRETE SLAB, RE: STRUCTURAL TERRAZZO FLOOR FINISH CONT. SEALANT PEMKO #346C DOOR-TOP WEATHERSTRIP, 40" LENGTH 10"1' - 8"CUT MIN. 4-1/2" DIA. HOLE FOR J- BOX 3 1/2" 4" OCTAGONAL J-BOX4"LIGHT FIXTURE WC1 MOUNT J-BOX FLUSH W/ FACE OF MOUNTING BLOCK LT FIXT. OUTLINE TOWER PIER LIGHT FIXT. WC1 MOUNTING BLOCK: MFR:BORAL MODEL:FLAT TEXTURED CAPSTONE, 10" W X 20" L COLOR:"TAUPE" NOTES:CUT OPENING FOR 4" OCTAGONAL J-BOX AS SHOWN. CENTER BLOCK ON LT. FIXT. SECTION FRONT VIEW 4' - 6" 2' - 3"2' - 3" VENTILATION OPENING IN SHEATHING 5/8" SHEATHING NEOPRENE BLOCK 2X WD. BLOCKING 2 LAYERS, 5/8" SHEATHING WRAP W/ ICE & WATER SHIELD CAP HIP COVER 8 " +/-8" +/- ICE & WATER SHIELD METAL ROOF PANEL VENTILATED Z- CLOSURE MIDPOINT BLOCKING 2X PLUS 5/8" PLWD. ALLOW GAPS IN BLOCKING FOR AIR FLOW ROOF CAP FIELD FABRICATED FROM FLAT SHEET PROVIDED BY MTL ROOF MFR 8" +/- WD. BLOCKING SET UP FROM BOTTOM EDGE OF CAP TO ALLOW FOR Z-CLOSURE SHEATHING VENTILATION OPENING IN SHEATHING LEAVE GAPS IN BLOCKING FOR AIR FLOW AREA OF ROOF CAP ROOF HIP 8 A6 ROOF CAP FIELD FABRICATED FROM FLAT SHEET CAP HIP COVER METAL ROOF PANEL HIP CAP EXTEND UNDER TOP CAP WIDER HIP COVER 8 A6 SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © - All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service prepared by: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.4/16/2020 12:07:07 PMA6218071904-17-2020S.G.A.D.M.WALL SECTIONS AND DETAILSORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA F85FB 2020.00 STORE #5380-ORN04/17/2020 1/2" = 1'-0"A6 1 TOWER SECTION 1/2" = 1'-0"A6 2 TOWER SECTION 6" = 1'-0"A6 3 RAIN SHIELD 1" = 1'-0"A6 5 TOWER LIGHT FIXTURE MOUNTING DETAIL 1 1/2" = 1'-0"A6 8 TOWER CAP HIP DETAIL 3/8" = 1'-0"A6 6 ROOF CAP PLAN VIEW 3/8" = 1'-0"A6 7 ROOF CAP PLAN VIEW Revision ScheduleNo.DescriptionDatePERMIT SET04/17/2020