HomeMy WebLinkAboutrevised page 5 canopy drawing.W1 8x35
ROOF FRAMING PLAN
SCALE: 1/8 = 1'-0
FOOTING SCHEDULE
MARK
DIMENSIONS:
LxWxD
#4 STEEL MAT #5 STEEL MAT
TOP AND BOTTOM TOP AND BOTTOM
#6 STEEL MAT
TOP AND BOTTOM
REMARKS
I-
0
UGENERAL NOTES
5'-0x5'-Ox5'-O
56'-0
#6@12o/c E.W
#4, #5, AND #6 OPTIONS
ALL STEEL SHOWN IS TO
BE PLACED EACH WAY.
DECK
-'
1 j
5L13/gx
1 1
L1 /2x1 /2x /g
15/gx 16GA
V)6'-0
46'-0
4'-0
3
FOUNDATIONS:
7
FASCIA BRACE
-0
,
54 -0
1 -0
CD4'-Oo/c w/
�-
�-
THE SOIL BEARING VALUE SHALL NOT BE LESS THAN 2000
7" GUTTER
TIE TRACK
PSF. THE BEARING VALUE SHALL BE VERIFIED BY THE G.C.
3mm ACM
FOOTINGS SHALL IN UNDISTURBED SOIL. ALL T/FOOT.
B
MAIN BEAM
FASCIA
ELEVATION ARE TO BE THE SAME UNLESS SHOWN OTHERWISE.
_
1/ » LIP
IF ELEVATIONS ARE NOT THE SAME CHAPMAN CANOPIES
L1x1x1/g
--'i (�---2-
MUST BE INSTRUCTED OF ELEV.'S IN WRITING WHEN CANOPY
W1 8x35
*EV
ORDER IS PLACED. FOOTINGS DESIGN COMPLIES W/ACI-318.
GUTTER
o
EI ® CING EL•
TYF.
ALL DEFORMED BARS SHALL COMPLY w/ASTM A615 FY=60 AND
1
/8
_
SHALL BE WIRE TIED AT ALL JOINTS. RUSTY, OILY, OR DIRTY
I
STEEL SHALL NOT BE USED.
f
I I I I
W1 8x35
1
I
I
STAGG. DECK
ANCHOR BOLTS:
FASCIA
3mm
TO BE
A.C.M.\//
CLIPS
PURLIN
3 5
L1 /8x1 /gx16GA
24 GA SCUPPER
TO MATCH GUTTER
ANCHOR BOLTS MUST BE INSTALLED WITH A TEMPLATE
AROUND ENTIRE CANOPY
RIVET TO GUTTER
AND WITHIN 1/8 -INCH OF MEASUREMENTS OF THE BASE
{
1
I I I I I
{
{
PLATE OR COLUMN WILL NOT FIT. CONCRETE CONTRACTOR
I I { I
!
{
1S RESPONSIBLE FOR RECESSING FOOTINGS 10 - INCHES
1
FLAT PAN DECK
L1 1/ x1 '/2x'/,,
BELOW FINISH GRADE AND FOR EXTENDING ANCHOR BOLTS
W1 8x351
2
SCUPPER
5 - INCHES ABOVE FOOTINGS IN ORDER FOR CANOPY TO
DECK
TO BE
T
GUTTER
ERECT PRO
PERLY. ANCHOR BOLTS SHALL BE ASTM F15547
22 GA
(PERIMETER)
.
GRADE 36.P-16
N
I
04x
I
X
co
SECTION
GOC
r.
B
FIN. DRIVE LEVEL
3
_
3
TYPIAL
RIDING
-
ALL CONCRETE SHALL BE 3000 PSI IN 28 DAYS. ALL CONC.
W1 8x35
L1 /2x1
/2x /8
SHALL BE PLACED IN ACCORDANCE WITH ACI -318.
I
I I I I I
I
I
1 1 1
L1 /x1 /x/
16x26
UC EL:
2 8
I
I I I I I
I
I
AT �CH PURLIN
5
4- /g
)��
DIA. A324N
ALL STRUCTURAL STEEL SHALL BE IN ACCORDANCE WITH
AISC SPECIFICATIONS. W -SHAPES SHALL BE ASTM A992.
MISCELLANEOUS STEEL, PLATES, ANGLES, AND CHANNELS ARE
TYP. 1
1 1 1
TO BE ASTM A36. HSS SHAPES SHALL BE ASTM A500 GR. C.
W1 8x35
ROOF FRAMING PLAN
SCALE: 1/8 = 1'-0
FOOTING SCHEDULE
MARK
DIMENSIONS:
LxWxD
#4 STEEL MAT #5 STEEL MAT
TOP AND BOTTOM TOP AND BOTTOM
#6 STEEL MAT
TOP AND BOTTOM
REMARKS
F5
5'-0x5'-Ox5'-O
#4@8o/c E.W #5@10o/c E.W
#6@12o/c E.W
#4, #5, AND #6 OPTIONS
ALL STEEL SHOWN IS TO
BE PLACED EACH WAY.
1/8 L1 /2x1 /2x /8 PROOF OF WELDERS CERTIFICATION SHALL BE AVAILABLE
1 BRIDGING TYP. ON REQUEST. AL BOLTS SHALL BE IN ACCORDANCE
w/ASTM A325.
OTHER CONCRETE S:
OTHER CONCRETE ITEMS SUCH AS DRIVE THRU SLAB,
BUILDING SLAB, PERIMETER FOOTING AND LOAD BEARING
FOOTINGS NOT USED FOR THE CANOPY ARE TO BE AT
THE SAME ELEVATION UNLESS SHOWN OTHERWISE. IF
W18x35 ELEVATIONS ARE TO VARY, CHAPMAN CANOPIES MUST BE
INSTRUCTED OF ELEVATIONS IN WRITING WHEN ORDER IS
46'-0 PLACED.
SECTIONE
FOUNDATION NOTE:
W _
5 _
FOOTINGS PROVIDED BY CUSTOMER. CHAPMAN CAN. IS NOT
_f5 RESPONSIBLE OR LIABLE FOR THE USE OF EXIST. FOOTINGS.
I 1
NOTE: THIS CANOPY IS DESIGNED PER ASCE 7-16 STRUCTURE LOADS
SEE FIG. 27.3-4, UNBALANCED WIND LOAD
HSS10x10x /16 HSS10x10x /16 3» ,' '' -- TOP MAT (SEE SCH.) CODE REFERENCE
�,.� 2017 FLORIDA CODE
u.. .., .......,.,.,
• ,..,. .....,..........,.......�1.20 53.03 6th EDITION
as
30
CASE A ( ) (13.26)
#3014
DEAD LOAD 4.0 PSF 1606.1
#4 EA. CORNER
CASE B
3'-0 BOTTOM MAT (SEE SCH.)
LIVE LOAD 20.0 PSF w APP. RED. 1607.12.2.1
SNOW LOAD 1.0 PSF + DRIFTS ASCE 7-16 PART 7.0
WIND SPEED 159.0 MPH 3 SEC. GUST 49.1 PSF ASCE 7 PART 26-29
CATEGORY 11 Iw 1.0 EXP. C
VERT. ROOF PRESSURE
Case A Cnw Cnl Case B Cnw Cm ASCE 7 FIG. 27.3-4
* CLEAR WIND FLOW 1.20 53.03
.30 13.26 -1.10(-48.61) -.10(-4.42)
F5 r _ _ �F5 SECTION A 14 * PLACE ANCHOR BOLTS NOTES: HORIZ. FASCIA PRESSURE EXP. C
I I I - ON 14 IN. C/C
1 1. THESE LOADS HAVE BEEN APPLIED TO STRUCTURE Case A & B Cfz Cfx ASCE 7 FIG. 29.3-1
{ C 3 IN 8 BASICCCOMB COMBINAORDANCE TIONS FOR ALLOWABLE16, STRESS TER ' 2.4.1 1.89 92,93 1.87 91.62
L--- - GUSSETS EACH ASCE _
SIDE OF COLUMNS SEISMIC DATA ASCE 7-16
HSS10x10x5/1g HSS10x10x5/1g T- 2. THESE STEEL MEMBERS HAVE BEEN SIZED BASED ON
STEEL TUBE w/ 30 ASD, AISC 14th EDITION. SEISMIC DESIGN 2 SEC. SPECTRUM RESPONSE Ss 0.0560 FIG. 22.1
FOUNDATION PLAN BASE1 i-1x18x1'-6 L CATEGORY 1 SEC. SP
4-1 /4 DIA. x 34 A.B 4 TAB. 11.6(1)(2) SPECTRUM RESPONSE S1 0.0290 FIG. 22.2
1 1�_p 11/2» NON -SHRINK GROUT 3. ANALYSIS OF THIS STRUCTURE HAS BEEN ACCOMPLISHED LONG PERIOD TRANSITION PERIOD TI 8 FIG. 22-14
SCALE: /g - 14 * UNDER BASE R USING THE LATEST GENERATION OF MATRIX BASED A G -
1
PLACE ANCHOR BOLTS (GROUT BY OTHERS) SOFTWARE. RISK CATEORY 11 TAB. 1.5
ON 14 IN. C/C
�P' 5 SEISMIC FACTOR le 1.00 TAB. 1.5-2
46'-0 /16 4. COLUMN SLENDERNESS FACTORS ARE BASED ON
PAVEMENT I I CHAPTER C, DIRECT ANALYSIS METHOD. SITE COEFFICIENT Fa 1.60 TAB. 11.4-1
,R36 Kx = 1.0 SITE COEFFICIENT Fv 2.40 TAB. 11.4-2
r
1 P-3/8 GUSSETS EACH 1 I Kz = 1.0 SITE CLASSIFICATION D TAB. 20.3-1
SIDE OF COLUMNS SEE PLAN 5. BASES ARE FIXED. SITE ADJUSTMENT COEFFICIENT, Sms 0.0896 EQ. 11.4-1
STEEL
TUBE w/ 30 I Q
BASE1 1x18x1 -6 L_ SITE ADJUSTMENT COEFFICENT Smi 0.0696 E 11.4-2
HSS10x10x5/16 LO
HSS10x10x5/16 4-1 /4 DIA. x 34 A.B 4 •
11/2" NON -SHRINK GROUT DESIGN SPECTRAL RESPONSE SDS 0.0598 EQ. 11.4-3
UNDER BASE z z #4 EACH CORNER
(GROUT BY OTHERS) g Q 63/ 63/ 3 DESIGN SPECTRAL RESPONSE SD1 0.0464 E!2. 11.4-4
TYP. 5 a f� /g STIFF. NS FS
/16 I I w w WELDED TO BEAM W Kips 10.30 12.8
PAVEMENT I I Li o
J Z X
M( SEISMIC RESPONSE COEFFICIENT Cs 0.0199 0.0478 12.8.1.1
Los
o- ---•
to f
SEE PLAN
TAIL C
o _ {�R36 _ I TYP.�--�-
1 5/16
H Pit/4 STI FF
- CTRD ON
ANGLE
C
16x26 Ga. = 23/4
i-1x11x1'-4
WELDED TO COLUMN
HSS10x10x5/16
DiHSS10x10x5/16 A I ON 4 SIDES
Digitally signed I i 4-1 DIA. A325 BOLTS
FOUNDATION P (ALTERNATE)
4 by Gregory R 2 -EACH SIDE
HSS10x10x /16
SCALE: 1/8 = 1'_01 Miller
36 Date.
2020.04.16 SECTION D
DETAIL rH 06:23:25 -05'00' -
(OFI-10NA1,,.} -
NO. I DAT :
4/15/2020
A2u
I'll/ v \ ,
CARTER MILLER SANSING: 0-024
DATE: 1/22/20
�:r:,���.��l:i��ty[.��r�1�.���1�1��0�'#afyt�t�•�:���tiy�I►t�y
METHOD • ANALYSIS
♦ R 1. LATERAL
Y.♦ FORCE
L 1 .
MANUFACTURER:
GREGORY (CA 31480)
CHAPMAN CANOPYINC.
FLORIDA R. MILLER 201 PATRICIA STREET/P.O. BOX 3527/HUEYTOWN, AL 35023
FL REG. 50338 PHONE: 1-(205) 491-4845
R
R}0.050338 *n
®..qq STATE OF o
19000-00,
00 OVAL °
°®0000000000
CUSTOMER:
NOTED DRAWN:
DATE: APPROVED BY: REVISED:
LOCATION:
3207 INDUSTRIAL 27TH ST.
FORT PIERCE, FL
DRAWING NO:
19317-014