HomeMy WebLinkAbout5380-F85FB-v20.0 - Sheet - E7 - SINGLE LINE DIAGRAMS, DETAILS AND NOTESSINGLE LINE NOTES: RTU 3 RTU 2 RTU 1 GENERAL ELECTRICAL NOTES M REFRIGERATION UNIT(RE: "MDP" PANEL SCHEDULE)GE SPECTRA SERIES PANELBOARD 3Ø, 4W, 120/208V, 42kAIC, 1200 AMP BUS -MAIN BREAKER COMBINED WITH THE BRANCH CIRCUIT BREAKERS, PROVIDES A SERIES RATING OF 65 KAIC. REMOTE 1. ELECTRICAL CONTRACTOR SHALL FURNISH ALL LICENSES, PERMITS, ETC. REQUIRED TO PERFORM THE WORK. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL REQUIREMENTS OF THE LANDLORD, LOCAL AUTHORITIES, THE UTILITY COMPANY, THE NATIONAL ELECTRICAL CODE AND ALL OTHER AUTHORITIES HAVING JURISDICTION. UPON COMPLETION OF WORK, ELECTRICAL CONTRACTOR SHALL FURNISH TO OWNER A CERTIFICATE OF APPROVAL ISSUED BY LOCAL AUTHORITIES OR BY AN ELECTRICAL INSPECTION AGENCY LICENSED BY LOCAL AUTHORITIES TO PERFORM SUCH INSPECTIONS, ALL ELECTRICAL ITEMS FURNISHED AND/OR INSTALLED BY ELECTRICAL CONTRACTOR SHALL BE UNCONDITIONALLY GUARANTEED FOR BOTH PARTS AND LABOR FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY OWNER. LIGHT BULBS AND LAMPS SHALL BE EXEMPT FROM THIS GUARANTEE; HOWEVER, ON THE DATE OF FINAL ACCEPTANCE BY OWNER, ALL LIGHT BULBS AND LAMPS SHALL BE IN WORKING ORDER. WHERE AN ITEM HAS BEEN FURNISHED BY OTHERS AND INSTALLED BY ELECTRICAL CONTRACTOR, ONLY THE INSTALLATION AND WIRING SHALL BE GUARANTEED BY ELECTRICAL CONTRACTOR; GUARANTEE ON THE ITEM SHALL BE PROVIDED BY THE PARTY FURNISHING THE ITEM. 2. GENERALLY, ALL WIRING SHALL BE INSTALLED IN ELECTRICAL METALLIC TUBING (EMT). SET SCREW FITTINGS MAY BE USED IN AREAS NOT SUBJECT TO MOISTURE; USE WEATHERPROOF COMPRESSION FITTINGS IN ALL LOCATIONS SUBJECT TO MOISTURE. FINAL CONNECTIONS TO RECESSED LIGHTING FIXTURES, VIBRATING EQUIPMENT, ETC. SHALL BE MADE WITH FLEXIBLE METALLIC CONDUIT ("GREENFIELD") IN LENGTHS NOT TO EXCEED 5 FEET; WHERE SUCH CONNECTIONS ARE MADE IN LOCATIONS SUBJECT TO MOISTURE, USE WEATHERPROOF FLEXIBLE METALLIC CONDUIT ("SEALTITE") IN LENGTHS NOT TO EXCEED 5 FEET. IF PERMITTED BY LANDLORD AND LOCAL AUTHORITIES, CONCEALED BRANCH CIRCUIT WIRING MAY BE INSTALLED IN METALLIC CABLE ("MC"). MC CABLE SHALL BE INSTALLED IN A WORKMANLIKE MANNER. NO SUCH CABLE SHALL BE INSTALLED IN FRONT OF WALL OR PARTITION FROM CEILING SPACE DOWN INTO PANEL. SUCH CABLES SHALL BE INSTALLED WITHIN WALL OR PARTITION IF POSSIBLE. IF SUCH CABLES ARE INSTALLED IN FRONT OF WALL OR PARTITION, USE CONDUIT SLEEVES OR ENTER CABLES INTO A JUNCTION BOX INSTALLED ABOVE CEILING AND SPLICE ONTO WIRING INSTALLED IN CONDUIT DOWN INTO PANEL. IF LATTER METHOD IS USED, INSTALLATION MUST BE IN COMPLIANCE WITH THE NATIONAL ELECTRICAL CODE AMPACITY TABLES. FOR THIS PURPOSE, #12 AWG TYPE THHN WIRE SHALL BE RATED AT NOT MORE THAN 25 AMPERES. ALL EXPOSED WIRING, PANEL FEEDERS, HVAC EQUIPMENT FEEDERS, ETC. SHALL BE INSTALLED IN ELECTRICAL METALLIC TUBING (EMT). NO EXPOSED NON-METTALIC CABLE SHALL BE PERMITTED. 3. WIRING IN EARTH OR CONCRETE SHALL BE INSTALLED IN GRC CONDUIT, IMC CONDUIT OR PVC CONDUIT (SCHEDULE 40). EACH CONDUIT RUNNING OUT TO OR THRU THE GAS CANOPY OR TANKS AREA SHALL BE GRC FOR THE ENTIRE RUN OF CONDUIT. WHERE PVC CONDUIT IS USED, AN ADDITIONAL GROUND WIRE SHALL BE INSTALLED AS REQUIRED BY THE NATIONAL ELECTRICAL CODE. THERE SHALL BE NO EXPOSED PVC CONDUITS. ALL STUB UPS, EXTENSIONS ABOVE GRADE, ETC. SHALL BE IN METAL RACEWAY. USE GRC CONDUIT, IMC CONDUIT OR EMT. (THERE SHALL BE NO EMT INSTALLED IN CONTACT WITH EARTH OR CONCRETE.) ALL UNDERGROUND CABLE SHALL BE INSTALLED IN RACEWAY. NO DIRECT BURIAL CABLE OF ANY KIND SHALL BE USED UNLESS SPECIFICALLY NOTED. ALL UNDERGROUND WIRING SHALL BE INSTALLED AT DEPTHS AS PRESCRIBED BY THE NATIONAL ELECTRICAL CODE. WHERE REQUIRED BY THE N.E.C., INSTALL A CONCRETE ENVELOPE AROUND CONDUITS. FOR UNDERGROUND WIRING IN EXCESS OF 600 VOLTS, A CONTINUOUS WARNING RIBBON SHALL BE INSTALLED 24" ABOVE CONDUITS STATING "CAUTION BURIED HIGH VOLTAGE LINE BELOW". RIBBON SHALL BE DETECTABLE TYPE AND SHALL BE LEM PRODUCTS #DET-609 OR EQUAL. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING OF FINISHED SURFACES, EXCAVATION, CONCRETE ENVELOPES, TAMPING, BACKFIELD, ETC. REQUIRED FOR INSTALLATION OF UNDERGROUND WIRING. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO DETERMINE THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES, FACILITIES, ETC. PRIOR TO STARTING ANY EXCAVATION. ELECTRICAL CONTRACTOR SHALL HAVE TOTAL RESPONSIBILITY FOR ANY DAMAGE DONE TO ANY EXISTING UNDERGROUND UTILITIES OR OTHER FACILITIES BY HIS WORK. COLORS AND FINISHES OF ALL SWITCHES, RECEPTACLES, DIMMERS, COVER PLATES, ETC. WILL BE SELECTED BY ARCHITECT. VERIFY ALL SUCH COLORS AND FINISHES PRIOR TO INSTALLING ANY WIRING DEVICES. 4. SWITCHES AND RECEPTACLES SHALL BE SPECIFICATION GRADE (NOT "COMMERCIAL GRADE"). ALL WIRING DEVICES SHALL BE RATED AT 20 AMPS AT THE VOLTAGE AT WHICH THEY WILL BE USED. WIRING DEVICES SHALL UTILIZE CLAMP TYPE TERMINALS; BACK WIRED "PRESSURE TYPE" INSERT TERMINALS ARE NOT ACCEPTABLE. SINGLE POLE SWITCHES SHALL BE HUBBELL #1221 SERIES (OR EQUAL); 3 WAY SWITCHES SHALL BE HUBBELL #1223 SERIES (OR EQUAL). FOUR WAY SWITCHES SHALL BE HUBBELL #1224 SERIES (OR EQUAL). DUPLEX RECEPTACLES SHALL BE HUBBELL #5362 SERIES (OR EQUAL). DIMMERS SHALL BE AS SPECIFIED ON DRAWINGS. WHERE SWITCHES AND DIMMERS ARE SHOWN ADJACENT TO EACH OTHER, DO NOT INSTALL IN COMMON "GANG BOXES". SWITCHES MAY BE IN COMMON BOXES AND DIMMERS MAY BE IN COMMON BOXES. HOWEVER, IF SWITCHES AND DIMMERS ARE INSTALLED IN SAME COMMON BOX, COVER PLATES WILL NOT ALIGN PROPERLY. ALLOW 1" SPACE BETWEEN SWITCH BOXES AND DIMMER BOXES. CAUTION: USE SEPARATE NEUTRALS FOR EACH DIMMER CIRCUIT. USE OF A COMMON NEUTRAL MAY CAUSE DIMMERS TO MALFUNCTION. WHERE SWITCHES ARE SHOWN GANGED TOGETHER, LOCATIONS ARE DIAGRAMMATIC ONLY. ARRANGE SWITCHES IN ROWS AS FIELD CONDITIONS DICTATE. 5. ISOLATED GROUND CIRCUITS SHALL CONTAIN FULL SIZE, INSULATED, ISOLATED GROUND WIRE WHICH SHALL RUN DIRECTLY FROM RECEPTACLE GROUND TERMINAL TO THE SERVICE ENTANCE EQUIPMENT GROUND BUS IT SHALL BE CONNECTED AT NO OTHER POINT. WIRING FOR SUCH CIRCUITS SHALL NOT SHARE A NEUTRAL WITH NOR BE IN THE SAME CABLE OR RACEWAY WITH WIRING FOR ANY OTHER CIRCUIT. AT EACH LOCATION SHOWN, FURNISH AND INSTALL A 20 AMP, DUPLEX, ISOLATED GROUND RECEPTACLE IN PRECISE LOCATION AS DIRECTED IN FIELD. ISOLATED GROUND RECEPTACLES SHALL BE HUBBELL #IG5362 OR EQUAL. WHERE SUCH CIRCUITS ARE IN CLOSE PROXIMITY, ONE COMMON ISOLATED GROUND WIRE MAY BE INSTALLED TO SERVE TWO SUCH RECEPTACLES. HOWEVER, EACH RECEPTACLE SHALL CONTINUE TO BE SERVED BY A SEPARATE CIRCUIT AS SHOWN. 6. ALL WIRE/CONDUCTORS FOR THIS PROJECT SHALL BE COPPER REGARDLESS OF WIRING METHOD. SFHA 250AF 225AT INSTALL 2 @ 6" PROTECTIVE BOLLARDS (TYP)50AT 150AF GROUND BUS SEHA 1 LIGHTING CONTACTOR PANEL 150AF SEHA 60AT 2 SEHA 150AF 50AT 3 4 (4)#4/0, (1)#4G(4)#4/0, (1)#4GRPALPA 5 SFHA 250AF 100AT 250AF 225AT SFHA 6 7 REMOTE CT METERING CABINET TO BE LOCATED AT TRANSFORMER NEAR UTILITY SERVICE 1200A., 3PH., 4 WIRE 120/208V INCOMING SERVICE COORDINATE WITH UTILITY CO. 250AF SFHA 60AT RPG EMERGENCY SHUT-OFF CONTACTOR PC-RPG EMERGENCY SHUT-OFF PC-RPD CONTACTOR 10 SEC.(4)#4/0, (1)#4G(2)#4/0, (1)#4G, & (1)#4 I.G.(4)#4/0, (1)#4GRPB RPC 1 SFHA 250AF 225AT 8 SFHA 250AF 225AT 9 (4)#6, (1)#10GSEC. 2 RPD 2 POLE SFHA 250AF 200AT 11 12 RPU 250AF 13131313 SPACE 250AF 14 POWERPLUS INTEGRATED ELECTRICAL DISTRIBUTION SYSTEM MDP BUS BAR CT METERS (1) PER PHASE LEG (4) 3" CONDUITS EACH CONTAINING (4) 350 KCMIL & (1) # 3/0 G & (2) SPARE 3" CONDUITS (1) 2" CONDUIT (WAWA METERING) (#4/0 G IS FOR BONDING OF CT CABINET . DO NOT RUN THIS IF UTILITY IS BONDING THE CABINET TO THEIR SYSTEM) SPACE PANEL MDP SHALL BE GE SPECTRA SERIES PANELBOARD SE LABEL, BOTTOM FEED, 3P4W, 120/208V, 42KAIC, 1175 AMP, 3 POLE TYPE SKHH8 MAIN CIRCUIT BREAKER. PANELS LPA, RPA, RPB, RPC AND RPH, SHALL BE GE TYPE AQ PANELBOARDS AS NOTED (TOP FEED, MAIN LUG ONLY). PANEL RPG SHALL BE GE TYPE AQ FEED THROUGH PANELBOARD WITH 100 AMP, MAIN LUGS (TOP FEED) AS NOTED. PC-RPG SHALL BE SQUARE D, 100 AMP, 3 POLE CONTACTOR, TYPE 8903SQO3V02. DISCONNECTING OF FUEL PUMPING EQUIPMENT SHALL COMPLY WITH NEC 514.11. PC-RPD SHALL BE SQUARE D, 200 AMP, 2 POLE ELECTRICALLY HELD CONTACTOR, TYPE 8903SVO1V02. DISCONNECTING OF FUEL PUMPING EQUIPMENT SHALL COMPLY WITH NEC 514.11. VERIFY ALL SHORT CIRCUIT RATINGS AND SERVICE REQUIREMENTS WITH UTILITY. ALL PANELS TO BE FULLY RATED. VERIFY ALL NAMEPLATE DATA AND INSTALL PER N.E.C. NOTIFY WAWA PROJECT MANAGER OF ANY DISCREPANCIES. COORDINATE CIRCUIT PROTECTION REQUIREMENTS WITH CONTRACTOR SUPPLYING EQUIPMENT. ALL EQUIPMENT FED FROM THIS PANEL SHALL BE SUPPLIED WITH AN INSULATED, ISOLATED EQUIPMENT SAFETY GROUND. THE INSULATED GROUND SHALL BE CONTINUOUS AND UNBROKEN FROM EQUIPMENT TO PANEL. PANEL RPD SHALL BE EQUIPPED WITH ISOLATED GROUND BUS BAR, PLUS AN EQUIPMENT GROUND BUS BAR. THE ISOLATED GROUND BUS WILL BE CONNECTED DIRECTLY TO MAIN DISTRIBUTION PANEL GROUND BUS WITH INSULATED GROUND WIRE. PANEL RPD SHALL BE GE TYPE, AQ FEED THROUGH SINGLE PHASE, 3 WIRE PANELBOARD (WIRED AS TWO WIRE), WITH 225A DUAL MAIN LUGS (TOP FEED) AS NOTED. ELECTRICAL CONTRACTOR SHALL INSTALL A JUMPER BETWEEN BOTH PHASE BUSES. PROVIDE SINGLE PHASE AND NEUTRAL FEEDER FROM MAIN DISTRIBUTION PANEL. ALL CIRCUITS FED FROM PANEL RPD SHALL BE DISCONNECTED BY EMERGENCY STOP EQUIPMENT PER METHOD GIVEN BY NEC 514.11.ELECTRICAL CONTRACTOR SHALL PROVIDE LAMINATED NAME PLATE INDICATING: BONDING AND GROUNDING OF NEUTRAL CONDUCTORS, EQUIPMENT GROUNDING CONDUCTORS, GROUNDING ELECTRODE AND BONDING JUMPERS SHALL PERFORM AT THE MAIN DISTRIBUTION PANEL AS REQUIRED FOR SERVICE EQUIPMENT BY ARTICLE 250 OF THE NEC. 200 AMP, 2 POLE BREAKER INSTALLED. ONLY 1 POLE OF THE 2 POLE BREAKER REQUIRED TO BE WIRED. RE: PANEL SCHEDULE SHEET E5 FOR WIRING CONFIGURATION OF PANEL RPD. ADD A LABEL TO PANEL RPG STATING “GASOLINE EQUIPMENT ONLY. DO NOT INSTALL ANY ADDITIONAL CIRCUITS” ADD A LEVEL TO PANEL RPU STATING “IT EQUIPMENT ONLY. DO NOT INSTALL ANY ADDITIONAL CIRCUITS” (1) #3/0 GND IN 1"C TO CONCRETE ENCASED ELECTRODE PER NEC 250-52A(3). RE: DETAIL 3/E7 (1) #3/0 GND IN 1"C TO EXTERIOR DRIVEN GROUND ROD PER N.E.C. #250-52A(3) (1) #3/0 GND IN 1"C TO BUILDING STEEL METALLIC CONDUITS MUST BE BONDED AT BOTH ENDS 12 11 10 8 9 7 6 5 3 4 2 1 12 9 3 9 45 10 1 POLE BREAKS NEUTRAL 1 POLE BREAKS ∅LEG 250AF SFHA 50AT EWH -(RE: "MDP" PANEL SCHEDULE)(RE: "MDP" PANEL SCHEDULE)2222 8 8 8 8 8 6 1 (RE: "MDP" PANEL SCHEDULE)(RE: "MDP" PANEL SCHEDULE)100% UL RATED 1175A UTILITY MAIN G 300 KW PORTABLE GENERATOR 120/208V 1000A RATED, 1000 AMP FULLY RATED MAIN BREAKER (PROVIDED BY WAWA) 100% UL RATED 1175A GENERATOR MAIN (3) 3-1/2" CONDUITS EACH CONTAINING (4) 500 KCMIL & (1) # 4/0 G NEMA 3R RATED PORTABLE GENERATOR CONNECTION BOX. SEE SHEET E1 AND DETAIL ON SHEET E6. SINGLE KEY OPERATION (REFER TO INTERLOCKING SEQUENCE OF OPERATION) PROVIDE DUAL MAIN BREAKERS WITH MANUAL TRANSFER SURFACE MOUNTED KIRK-KEY INTERLOCKS WITH TAMPERPROOF BOLTS "A" "B" SINGLE KEY OPERATION PROHIBITS THE TWO LOCKING DEVICES FROM BEING DISENGAGED AT THE SAME TIME. WITH THE KEY REMOVED BOTH DEVICES ARE IN THE LOCKED POSITION. TO CLOSE THE UTILITY MAIN CIRCUIT BREAKER, THE KEY MUST BE INSERTED INTO LOCK "A" AND ROTATED TO RETRACT THE INTERLOCK BOLT. THIS WILL ALLOW THE CIRCUIT BREAKER TO BE MOVED TO THE CLOSED POSITION. THE KEY IS CAPTIVE AND CANNOT BE REMOVED FROM THE LOCK UNTIL THE CIRCUIT BREAKER IS MOVED BACK TO THE OPEN POSITION AND THE KEY IS ROTATED TO EXTEND THE INTERLOCK BOLT. ONCE THE INTERLOCK BOLT HAS BEEN EXTENDED, THE KEY CAN BE RELOCATED TO LOCK "B". THE SAME PROCEDURE CAN THEN BE IMPLEMENTED TO CLOSE THE PORTABLE GENERATOR MAIN BREAKER. KIRK-KEY INTERLOCKING SEQUENCE OF OPERATION 11 "GASOLINE DISPENSING EQUIPMENT ONLY DO NOT INSTALL ANY ADDITIONAL CIRCUITS" TVSS TVSS TO BE PROVIDED AND INSTALLED BY PANEL BOARD PROVIDER/MANUFACTURER (4)#1, (1)#6GRPH 2 SEHA 150AF 125AT INTERSYSTEM TERMINATION GROUND BUS BAR PER NEC 250.94. TO PHONE, DATA, ETC BY OTHERS BONDING JUMPER INSULATED #6 AWG MINIMUM (3) #4 & (1) #8G 1-1/4"C.JUNCTION BOX FOR HARDWIRE CONNECTION SEE ELECTRICAL ROOM ELEVATIONS LOCATED IN COMPUTER SERVER RACK 208V, 1Ø, 3W INPUT TERMINALS. CONNECT PER EQUIPMENT INSTALLATION INSTRUCTIONS. (3) #4 (1) #7G (1) #8 IG 1-1/4"C. TO BUILDING STEEL TO COLD WATER PIPE (1) #8G UPS WITH BYPASS BY OTHERS INTERNAL CONNECTIONS BY OTHERS OUTPUT TERMINALS. CONNECT PER EQUIPMENT INSTALLATION INSTRUCTIONS JUNCTION BOX FOR HARDWIRE CONNECTION SEE ELECTRICAL ROOM ELEVATIONS LEAVE 8 FEET OF SLACK IN ALL CONDUCTORS AND FLEX TO AND FROM THE UPS RACK SO THAT THE RACK MAY BE ROLLED OUT TO BE WORKED ON. PROVIDE HOOK(S) ON WALL ABOVE J-BOXES TO COIL UP EXTRA CABLING. J J 208V, 1Ø, 3W GROUND PER NEC AND INSTALLATION INSTRUCTIONS LEGEND ELECTRICAL CONTRACTOR SHALL OBTAIN INTEGRATED POWER DISTRIBUTION SYSTEMS FROM CD CONTROLS. CONTACT ED RIOS FOR DELIVERY AND INSTALLATION REQUIREMENTS. OFFICE: 706-356-0325 CELL : 706-476-7303 EMAIL: WAWA@CDCONTROLS.COM INSTALLED BY ELECTRICAL CONTRACTOR PRE-WIRED BY PANEL MANUFACTURER PROVIDE MAIN AND SYSTEM BONDING JUMPER SIZED #4/0 AT MDP. FRONT OF MDP SHALL HAVE ARC FLASH HAZARD WARNING LABEL PER NEC 110.16. LABEL SHALL ALSO COMPLY WITH NEC 110.21(B). EACH PANELBOARD SHALL BE PERMANENTLY MARKED TO INDICATE SOURCE OF SUPPLY PER NEC 408.4(B) 13 14 14 13 LOCATED IN THE MANAGER'S OFFICE PANEL RPG CONTACTOR PANEL RPD CONTACTOR NORMALLY CLOSED MOMENTARY NC CONTACT. RECESSED HEAD CLASS 9001, TYPE KA3 OPERATOR WITH 1 N.C. CONTACT SQUARE D # KR1RH6 CLASS 9001, TYPE K60 COVER ATTACHMENT SQUARE D ADDITIONAL EMERGENCY SHUT-OFF PUSHBUTTONS AS SHOWN ON PLANS AND REQUIRED BY LOCAL CODES (2) GE CONTACT BLOCK P9B10VN RPC-41 2 POLE NORMALLY OPEN MOMENTARY CONTACT. RECESSED PUSH BUTTON MARKED 'RESET' GE OPERATOR # P9MPNRE ∅ LOCATED AT CHECKOUT COUNTER RESET RESET N INCLUDE EMERGENCY SHUT-OFF PUSHBUTTON TO BE LOCATED BEYOND THE FUEL COURT CANOPY AREA. (SEE SHEETS E4 AND E6) LOCATED ON CONTACTOR ENCLOSURE 2 IN. MIN. 3/0 AWG BARE COPPER CONDUCTOR, OR STEEL REINFORCING BAR, OR ROD NOT LESS THAN 1/2-IN. DIAMETER AT LEAST 20 FT. LONG CONNECTION LISTED FOR THE PURPOSE NONMETALLIC PROTECTIVE SLEEVE GROUNDING ELECTRODE CONDUCTOR FOUNDATION IN DIRECT CONTACT WITH EARTH SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © -All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service preparedby: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.4/16/2020 10:56:22 AME7218071904-17-2020MLBJPMSINGLE LINE DIAGRAMS, DETAILS AND NOTESORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA F85FB 2020.00 STORE #5380-ORN04/17/2020 NOT TO SCALEE7 3 SINGLE LINE DIAGRAM NOT TO SCALEE7 1 EMERGENCY SHUT-OFF (CHECKOUT/CANOPY COLUMN/KIOSK) NOT TO SCALEE7 2 CONCRETE ENCASED ELECTRODE DETAIL Revision ScheduleNo.DescriptionDatePERMIT SET04/17/2020