5380-F85FB-v20.0 - Sheet - E6 - ELECTRICAL ROOM PLAN AND ELEVATIONS
FRPA RPC CONTACTORSLPARPB RPD-2 RPU RPD-1 CONT. GAS EQUIPMENT ONLY NO ADDITIONAL CIRCUITS PERMITTED RPHCONT.MDP RPG COMPUTER SERVER E6 5 6 4 MDPLPA CONT'S RPA RPC RPB RPU RPD-1 RPD-2 RPG RPH #6 AWG COPPER GROUND TO MAIN DISTRIBUTION PANEL GROUND BUS CONDUIT GROUND BUSHING TO ADDITIONAL CONDUIT GROUND BUSHINGS VERTICAL CONDUIT SEALING FITTING (FOR CLOSE TURNING RADIUS) CONDUIT STUB-UP ALL CONDUITS FROM HAZARDOUS AREA ELECTRICAL ROOM ELEVATION NOTES: 1. CONDUIT LAYOUT PLAN SHOWN ON PLAN HAS PROVISIONS FOR 12 DISPENSERS. THE ACTUAL NUMBER OF CONDUITS REQUIRED WILL BE DEPENDENT ON THE CANOPY CONFIGURATION, AND ACTUAL NUMBER OF DISPENSERS INSTALLED. IF FEWER DISPENSERS ARE INSTALLED, AND THEREFORE SUFFICIENT SPACE EXISTS, THE CONDUITS ARE TO BE INSTALLED IN A SINGLE ROW. 2. PROVIDE 2" UNDERGROUND CONDUIT FROM SPARES WIREWAY TO INTERCOM WIREWAY FOR COMMUNICATION/DATA WIRING. RE: SHEET E4. 3. ALL SPARE CONDUITS WHICH TRAVERSE THE HAZARDOUS AREA SHOULD BE PACKED WITH MINERAL FIBER FOLLOWED WITH DUCT SEAL, AND THEN SEALED WITH A THREADED PLUG OR CAP AS APPROPRIATE FOR THE SPECIFIC CONFIGURATION AT EACH END OF THE CONDUIT. 4. PANEL CC-3 AND REQUIRED CONDUIT SHALL BE PROVIDED BY BAS CONTRACTOR CONNECTED TO PANEL RPC-22:24:26 5. PANEL JACE/CC-4 AND REQUIRED CONDUIT SHALL BE PROVIDED BY BAS CONTRACTOR. 6. JUNCTION BOX, RECEPTACLES, AND ASSOCIATED CONDUIT TO MAIN DISTRIBUTION PANEL SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. JUNCTION BOX SHALL BE SURFACE MOUNTED. 7. RUN 1-2" CONDUIT TO MANAGER'S OFFICE. RUN CONDUIT DOWN INSIDE MANAGER'S OFFICE WALL AND STUB-OUT AT FUEL-TANK MONITOR EQUIPMENT LOCATION. ALSO, RUN 1" CONDUIT FROM MANAGER'S OFFICE FUEL TANK MONITOR ABOVE CEILING TO PANEL RPD IN ELECTRICAL ROOM. 8. ALL CONDUITS RUNNING OUT TO CLASS/DIV AREAS SUCH AS THE GAS CANOPY AND TANKS AREA SHALL BE GRC TYPE CONDUIT FOR ENTIRE RUN OF CONDUIT. CONDUITS TO OTHER AREAS SUCH AS MONUMENT SIGNS, AIR PUMP, SITE LIGHTING, ETC. MAY BE PVC. GASOLINE CONDUIT REQUIREMENTS: (1) 1" GRC SPARE TO COLUMN A OR C AS DICTATED BY FUEL COURT LAYOUT. (RE: SHEET CE1) (1) 1" GRC TO CANOPY COLUMN FOR LIGHTING. (COLUMN FURTHEST FROM STORE) -COLUMN B. (RE: SHEET CE1 FOR COUNT) (4) 3/4" GRC TO EACH DISPENSER. (1 POWER, 1 DATA, 1 MUSIC/INTERCOM, 1 FUEL-TANK MONITOR SENSOR) (2) 1" GRC TO EACH TANK STP CONTAINMENT SUMP. F.E. PETRO POWER (1 POWER, 1 SPARE) (1) 3/4" GRC TO EACH TANK STP COMPARTMENT SUMP. (FUEL-TANK MONITOR MAGNOSTRICTIVE PROBE AND FUEL-TANK MONITOR SENSOR) (1) 3/4" GRC TO EACH TANK MULTIPORT CONTAINMENT SUMP. (FUEL-TANK MONITOR MULTI-PORT FILL SUMP) (1) 3/4" GRC TO EACH TANK. (FUEL-TANK MONITOR BRINE INTERSTITIAL RESERVOIR) (1) 1" GRC TO OVERFILL ALARM. (ON VENT STACK) (1) 1" GRC TO VENT STACK (SPARE) (1) 1" GRC TO E-STOP AT STREET SIDE OF GAS CANOPY (RE: NOTE 15 ON SHEET E4) NOTE: VERIFY DIESEL FUEL REQUIREMENTS WITH WAWA PROJECT MANAGER. NOTE: ALL CONDUITS OUT TO OR THRU THE GAS CANOPY AND TANKS AREAS TO BE GRC. (1)-1" GRC TO EACH ISLAND FOR CANOPY LIGHTS (1 SHOWN, SEE NOTE #1) (1)-3/4" PVC FOR GROUND OF INCOMING TELEPHONE (2)-1" GRC TO EACH PYLON/MONUMENT SIGN. ONE FOR GENERAL DUTY RECEPTACLE AND LIGHTING,1 FOR PRICE SIGN DIGITS. (2)-1" PVC TO CHECKOUT POWER (2)-1" PVC TO SITE LIGHTS (1)-1" GRC SPARE RUN TO A POINT BEYOND CURB LINE, TERMINATE IN WATERPROOF PULLBOX (2)-1" PVC TO AIR MACHINE (2) 1" PVC TO CHECKOUT POWER (1)-3/4" GRC TO EACH DISPENSER FOR POWER (12 SHOWN, SEE NOTE #1) (2) 2" PVC TO CHECKOUT (1) 1" GRC TO OVERFILL ALARM (1)-1" GRC TO E-STOP AT STREET SIDE OF GAS CANOPY (SEE NOTE 15 SHEET E4) 12" X 12" WIREWAY CONDUITS FOR HVAC AND FRIDGE UNITS ON ROOF AND WATER HEATER, SIZED PER "MDP" SCHEDULE SHEET E5 BRANCH CIRCUIT CONDUITS, SIZES AND QUANTITY PER PLANS AND PANEL SCHEDULES 3" EXTENTION BELOW PANELS ENCLOSURE 11' - 8" 4" RPC -10 (1)-1" GRC TO SIMPLEX RECEPTACLE TO PRICE CHANGE CONTROLLER IN OFFICE AREA. SPARESVFCVFC VFCVFCVFCDHIDHIRPU-1 I.G. L5-30R TELEPHONE/ DATA OUTLET (3)-2" PVC, DATA TO CHECKOUT (2)-2" PVC, DATA TO FOOD SERVICE (1)-1" PVC, DATA TO FOOD SERVICE JUNCTION BOX IN WALL FOR POWER FEED TO UPS/BYPASS INPUT FROM PANEL RPC JUNCTION BOX IN WALL FOR UPS/BYPASS OUTPUT FEED TO PANEL RPU RPU-3 I.G. L5-30R (1)-1" GRC POWER TO EACH SUBMERSIBLE PUMP. FROM F.E. (5) PETRO VF CONTROLLERS. (1)-1" GRC TO EACH TANK COMPARTMENT (5 CONDUITS) (1)-1" SPARE TO COLUMN A OR C, AS DICTATED BY FUEL COURT LAYOUT (SEE SHEET CE1) (1)-1" GRC TO VENT STACK F.E. PETRO DHI RELAYS (TYP) (BY GASOLINE CONTRACTOR) F.E. PETRO VF CONTROLLERS (TYP) (BY GASOLINE CONTRACTOR) 1-1" POWER TO F.E. PETRO VF CONTROLLERS (FROM PANEL RPG) 1-1" POWER TO F.E. PETRO DHI RELAYS (FROM PANEL RPD) & SWITCH LEGS FROM DISPENSERS 2' - 0"2' - 6"5' - 0"4' - 0"4"NAC FACP PANTHER BOX BRCM PUMP DATAFUEL-TANK MONITOR DATAINTERCOM RPD-1 I.G. SIMPLEX RECEPT. MUSIC BY OTHERS MUSIC BY OTHERS NETWORK INTER- COMM PHONE (BY TELE. CO.) RPU-6 SECURITY (BY ALARM CON- TRACTOR)RPC-32RPU-13(1)2" DATA CONDUIT. SEE ELECTRICAL ROOM ELEVATION NOTE #7. DOOR CHIMES XFMR. (1) 3/4" GRC TO EACH DISPENSER FOR INTERCOM/CAMERAS/MUSIC (12 SHOWN, SEE NOTE #1) (1) 3/4" GRC TO EACH DISPENSER (12 SHOWN, SEE NOTE #1) FUEL-TANK MONITOR DATA (2) 3/4" GRC TO EACH TANK COMPARTMENT(10 CONDUITS) RPC-34 I.G. QUAD RECEPT. NOTE 6 RPD-4 MUSIC I.G. DUPLEX RECEPT. NOTE 6 (1)-3/4" PVC TO MDP FOR INCOMING PHONE GROUND (1)-1" PVC TO EACH CHECKOUT CORE (2)-2" PVC INTERCOM TO CHECKOUT (1) 3/4" GRC TO EACH DISPENSER (12 SHOWN, SEE NOTE #1) PUMP DATA 8" X 8" WIREWAYEC POVIDE CONDUITS TO AND FROM OVERHEAD WIREWAY AS REQUIRED (TYPICAL) DUPLEX RPD-4 QUAD RPC-30 DUPLEX RECPT RPU-12, I.G. BY PETROL CONTRACTOR AS REQUIRED (1) 3/4" GRC TO EACH TANK (3 CONDUITS) (3)-4" PVC PHONE/DATA/CABLE. (1) TO EACH SERVICE CC-3 NOTE #4 JACE/ CC-4 NOTE #5 RPC-34 RPC -10 5" PLASTIC BUSHING 5" METAL PUSH PENNY 5" METAL LOCKNUT 5" KNOCKOUT IN TMP3U12R 5" METAL CHASE BUSHING 7'-6" A BN C 32.35" 0'-6" 1 2 (3) 3-1/2" CONDUIT SLEEVES TO MDP GENERATOR MAIN GE CATALOG # TMP3U12R NEMA 3R RATED (METER-MOD 3 / MAIN PULL BOX MODULE) 1200 AMPERE MAX. - 3 PHASE / 4 WIRE (SHOWN WITH EXTERIOR FRONT COVER REMOVED) (3) 2-500 KCMIL MECHANICAL LUGS NEMA SPACED. (4) 1/2" 13 X 3" STUD SETS 1-3/4" APART. (3) TWO CONDUCTOR, TWO HOLE NEMA SPACED 2-500KCMIL MECHANICAL LUGS. PROVIDE PROFESSIONAL LABELS INDICATING PHASE LEGS. WAWA GENERATOR WIRING TO CONNECT HERE FROM PORTABLE GENERATOR 1 2 (1) TWO CONDUCTOR, TWO HOLE NEMA 2-600KCMIL MECHANICAL LUGS (2) TGL6 (3)#2-250. SAFETY SWITCH GROUND KIT 56.86" VERIFY THAT CONNECTION BOX MANUFACTURER HAS PROVIDED PER NEC 702.7(C) A SIGN INSIDE OR OUTSIDE COVER THAT STATES "WARNING: FOR CONNECTION OF A NONSEPARATELY DERIVED (FLOATING NEUTRAL) SYSTEM ONLY". PROVIDE SIGN IF REQUIRED. APC APPROXIMATE DIMENSIONS: 22"W X 29.5"D X 70"H SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © -All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service preparedby: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.4/16/2020 10:56:17 AME6218071904-17-2020MLBJPMELECTRICAL ROOM PLAN AND ELEVATIONSORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA F85FB 2020.00 STORE #5380-ORN04/17/2020 1/2" = 1'-0"E6 1 ELECTRICAL ROOM - PLAN 1/2" = 1'-0"E6 4 ELEVATION 1 - C 1/2" = 1'-0"E6 6 ELEVATION 1 - B 1/2" = 1'-0"E6 5 ELEVATION 1 - A 1 1/2" = 1'-0"E6 2 300KW CONNECTION BOX DETAIL BUILDING AUTOMATION SYSTEM (BAS) GENERAL CONTRACTOR TO INSTALL WATER METER(S) FOR B.A.S. PER PLUMBING DRAWINGS P4, AND PROVIDE UNDERGROUND CONDUIT TO EQUIPMENT #C3.2 SHOWN ON DRAWING EQ1. B.A.S. REFRIGERATOR COMPANY INSTALLERS SHALL SUPPLY AND INSTALL B.A.S. AND CENTRAL WIRING PER CURRENT EDITION OF “BUILDING AUTOMATION SYSTEM 2010 (LITE) MASTER-BILT NEW STORES B.A.S. MASTER SPECS”BY HVAC CONCEPTS INC. AND AVAILABLE IN PLAN EXPRESS PROJECT FOLDER. 1/2" = 1'-0"E6 7 DATA CABINET DETAIL Revision ScheduleNo.DescriptionDatePERMIT SET04/17/2020