5380-F85FB-v20.0 - Sheet - M1 - HVAC FLOOR PLAN
1 2 3 7 7.8 8 F E D ASSOCIATE VESTIBULE OFFICE STAGING C TH TH WOMEN'S RESTROOM TH 6"ø 12x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x20 10"ø 28x2024x27 AC-1 A. MECHANICAL CONTRACTOR SHALL ADJUST ALL LINEAR SLOT DIFFUSERS TO A GENERALLY VERTICAL FLOW. ADJUSTMENT SHALL BE MADE SO AS TO AVOID AIRFLOWS ON SENSORS, REFRIGERATION CASES, OR OPEN FOOD REFRIGERATION EQUIPMENT. C B A 3.5 4 5 6 KEY NOTES: SHEET GENERAL NOTE: 12 WATER SERVICE ROOM 24x27 DN. FROM RTU-2 28x20 27x24 AC-2 UP TO EF-3 WALK-IN FREEZER WALK-IN REFRIG. COFFEE RETAIL AREA RETAIL AREASELF SERVICE WALK-IN REFRIG. RETAIL WALK-IN REFRIG. REAR VESTIBULE MEN'S RESTROOM ELECTRICAL ROOM WASH ROOM FOOD SERVICE DELIVERY VESTIBULE CD-4 70 CFM CD-4 70 CFM CD-3 100 CFM CD-3 40 CFM CD-3 40 CFM CD-1 200 CFM LD-1 315 CFM LD-1 325 CFM LD-1 315 CFM LD-1 325 CFM LD-1 315 CFM LD-1 315 CFM 8"ø 20x1610"ø 10"ø 10"ø14x16 12x1212"ø 6"ø 6"ø 8"ø6"ø 6"ø 6"ø 8"ø 6"ø8"ø18x1616"ø12"ø10"ø14"ø 12"ø 10"ø 12"ø 10"ø 10"ø 10"ø 10"ø 10x1210"ø18x1812"ø14"ø 12"ø 12"ø 14"ø 12"ø 12"ø 12"ø12"ø24x2210"ø 10"ø10"ø 10"ø 10"ø 10"ø 8"ø LD-1 315 CFM LD-1 315 CFM 8"ø 14"ø14"ø10"ø10"ø10"ø 14"ø 14"ø 22x2014"ø 14"ø 14"ø 14"ø LD-1 315 CFM 12"ø 12"øG-1 720 CFM G-1 720 CFM G-1 720 CFM G-1 720 CFM LD-2 440 CFM LD-2 440 CFM LD-2 440 CFM LD-2 440 CFM LD-2 440 CFM16"øLD-2 445 CFM LD-2 445 CFM LD-2 445 CFM LD-2 445 CFM 16"ø 12"ø 12"ø LD-1 270 CFM CD-1 550 CFM 12"ø14"ø18"ø 10"ø 10"ø 12"ø DROP 10 10 1010 9 6 6 12"ø 12"ø12"ø10"ø 9 18"ø 14"ø 14"ø 10 10 G-1 770 CFM G-1 770 CFM G-1 770 CFM 10 14"ø 28x2414"ø 6 6 14"ø G-1 770 CFM 14"ø G-1 765 CFM (2 TYP.)14"ø 14"ø G-1 550 CFM G-1 550 CFM LD-1 270 CFM LD-1 300 CFM CD-3 45 CFM LD-1 365 CFM LD-1 365 CFM LD-1 365 CFM LD-1 200 CFM LD-1 200 CFM 6"ø 6"øDROP 10"ø 6"ø 10"ø 10"ø 6 66 6 14"øDROPDROPCD-2 590 CFM 14"ø 14"øG-1 765 CFM (3 TYP.) 14"ø (3 TYP.) 14"ø G-2 590 CFM G-1 590 CFM 6"ø10"ø 10"ø 14"ø 14"ø14"ø 14"ø14x1214"ø 1 8"ø8"ø 8"ø 8"øG-1 70 CFM G-1 70 CFM G-1 140 CFM 2 2 2 3 3 4 4 4 5 5 6 6 6 6 6 6 6 6 6 6 6 6 10 7 8 8 8 8 8 9 9 9 9 9 9 20x1828x20 13 14 12 G-3 60 CFM G-4 100 CFM G-4 100 CFM 8"ø 10"ø8"ø DN. TO GRILLE 8 8"øG-4 100 CFM 11 6"ø8 8 10 G-1 60 CFM G-5 60 CFM 8"ø 15 15 15 15 15 G 20x18HVAC LEGEND SYMBOL DESCRIPTION NEW RECTANGULAR OR ROUND DUCT FLEXIBLE DUCT SUPPLY AIR DUCTWORK UP THROUGH PLAN RETURN AIR DUCTWORK UP THROUGH PLAN EXHAUST AIR DUCTWORK UP THROUGH PLAN 90° ELBOW WITH TURNING VANES MANUAL AIR VOLUME CONTROL DAMPER 4 WAY SUPPLY DIFFUSER 3 WAY SUPPLY DIFFUSER 2 WAY OPPOSED SUPPLY DIFFUSER RETURN AIR DEVICE EXHAUST AIR DEVICE CO2 SENSOR MECHANICAL EQUIPMENT TAG CONDENSATE PIPING XXX CFM A C RTU-10 COMBINATION TEMPERATURE/HUMIDITY SENSORTH LINEAR SLOT DIFFUSER WITH PLENUM AIR CURTAINAC-X LD-X 10x8 8"ø 12"ø PACKAGED ROOFTOP AIR CONDITIONERRTU-X ROOF MOUNTED EXHAUST FAN EF-X INLINE EXHAUST FAN 2 WAY CORNER SUPPLY DIFFUSER EF-X CFM TYPE MARK TEMPERATURE SENSORT SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © -All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service preparedby: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.4/16/2020 1:06:40 PMM1218071904-17-2020PAKJJDHVAC FLOOR PLANORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA F85FB 2020.00 STORE #5380-ORN04/17/2020 1/4" = 1'-0"M1 1 HVAC FLOOR PLAN Revision ScheduleNo.DescriptionDatePERMIT SET04/17/2020