5380-F85FB-v20.0 - Sheet - P4 - RISER DIAGRAMS
4" SANITARY I.E. = -3.25 @ 5'-0" OUTSIDE BUILDING 4" GREASE I.E. = -3.25 @ 5'-0" OUTSIDE BUILDING 4" SANITARY I.E. = -3.25 @ 5'-0" OUTSIDE BUILDING 2" VENT TO BE CONNECTED WITH GREASE INTERCEPTOR AT THE INLET AND OUTLET. 6 "ø S T 6 "ø S T ECO ECO 6 "ø S T 6 "ø S T ECO ECO 6"ø ST ECO 6"ø ST ECO 6"ø ST ECO 6 "ø S T ECO 6 "ø S T ECO ROOF AREA = 30 SF WALL AREA = 186/2 SF TOTAL AREA = 123 SF ROOF AREA = 29 SF WALL AREA = 32/2 SF WALL AREA =178/2 SF TOTAL AREA = 134 SF ROOF AREA = 156 SF WALL AREA =188/2 SF WALL AREA =160/2 SF TOTAL AREA = 330 SF ROOF AREA = 201 SF WALL AREA =178/2 SF TOTAL AREA = 280 SF ROOF AREA = 198 SF WALL AREA =170/2 SF TOTAL AREA = 283 SF ROOF AREA = 194 SF WALL AREA =228/2 SF TOTAL AREA = 308 SF ROOF AREA = 121 SF WALL AREA =142/2 SF TOTAL AREA = 192 SF 6 "ø S T ECO2"ø V2 "ø V 2 "ø V 2"ø V2"ø VFD-1 HUB-1 FD-3 HUB-1 3"ø S2"ø S3"ø SFCO 4 "ø S HUB-1 HUB-1 4 "ø S FCO 3"ø S 1 1/2"ø V2 1 /2 "ø V 2 "ø V 6 "ø S T 2"ø V2 "ø V2 1/2"ø V 2 1/2"ø V2"ø V2 1/2"ø V 2 1/2"ø V 2 1/2"ø V2 1/2"ø V 2 "ø V 2 "ø V 2"ø V2"ø V4 "ø S FCO 4 "ø S FD-1 3"ø S4 "ø S 4"ø S 4"ø S 3"ø S3"ø S3"ø S3"ø S4"ø S 2"ø V FCO FD-1 3"ø S3"ø S3"ø S4 "ø S 3"ø S 3"ø S HUB-1 HUB-1 3 "ø S 2 1/2"ø V1 1/2"ø V3"ø GR 3 "ø S3"ø S3 "ø S 3"ø S 3 "ø S 3"ø SFCO HUB-1 HUB-1 3"ø S HUB-1 HUB-1 HUB-1 HUB-1 HUB-1 3"ø S 3"ø S3"ø S4 "ø G R ECO 3"ø GR 3"ø GR3"ø GR 3"ø GR 1 1/2"ø V1 1/2"ø V3 "ø G R 3"ø GR2"ø VFS-1 FD-1 3"ø GR FS-1 3"ø GR4 "ø G R 4 "ø G R HUB-1 3"ø GR 3 "ø G R FS-1 FD-12"ø GR3"ø GR3"ø GRFS-1 3"ø GR 3"ø GR 3"ø GR3"ø GR1 1/2"ø V1 1/2"ø VFCO 4 "ø G R FS-5 FS-5 FS-5 HUB-1 3"ø GR3"ø GR2 1/2"ø V1 1/2"ø V2"ø V 2 "ø V2"ø V3"ø GR3"ø GRWC-1 LAV-2 WC-1 LAV-1 WC-1 UR-1 1 1/2"ø V LAV-2 EWC-1 MR-1 F5 F3 F5 F5 F5 F5 F5 2" VTR MIN. OF 36" ABOVE ROOF 2 1/2" VTR MIN. OF 36" ABOVE ROOF 2 1/2" VTR MIN. OF 36" ABOVE ROOF 3 "ø S4"ø GRROOF AREA = 115 SF WALL AREA = 42/2 SF TOTAL ROOF AREA = 136 SF TOTAL ROOF AREA = 3686 SF TOTAL ROOF AREA = 1235 SF TOTAL ROOF AREA = 2365 SF 1 1/2" PVC FOR 1/2" HW 2" PVC FOR 3/4" CSRX (3) 2" PVC FOR 3/4" CSRX, 3/4" HW, & 3/4" CW (2) 1 1/2" PVC FOR 1/2" HWR, & 1/2" CSR AAV AAV AAV AAV3"ø S3"ø S 4"ø S4"ø S3"ø S ECO ECO ECO 1 1/2"ø V3"ø S3"ø S3"ø GR1 1/2"ø V 3"ø GR3"ø GR2 1/2"ø V2"ø V2 "ø V 3"ø GR 3"ø GR3"ø GR MW4 MW4 MW9.1 3"ø GR1 1/2"ø V4"ø S LAV-1 MW5.4 4"ø S(2) 2" PVC FOR 1/2" HW & 1/2" CW AAV FS-5 3"ø GR 2" DOMESTIC WATER SERVICE. METER LOCATED IN EXTERIOR PIT. SEE CIVIL PLAN FOR CONTINUATION BOOSTER PUMP CONTROLLER ACI PRESSURE TRANSDUCER, PART # A/GP-100-20 2" DOMESTIC WATER MANIFOLD 1/2" UNSOFTENED CW TO FREESTYLE FILTER 3/4" CW TO WALL WCH 3/4" CW TO ROOF WCH 1 1/2" CW TO STORE 1" CW TO CSR SYSTEM 2" CW TO TOILET ROOMS 3/4" CW TO CANOPY WCH 2"ø CW WCH WATER PRESSURE GAUGE FOR 2" MAIN WATER, USE 1-1/2" WATER SUB-METER WITH 10 GALLON DRY CONTACT PULSE FOR INTERLINK TO BAS SYSTEM. WATER SUB-METER: MANUFACTURER: MASTER METER MODEL M22-A00-A04-0412A-1, 1-1/2" MAIN WATER SUB-METER DOMESTIC WATER PIPING: USE FLOWGUARD GOLD CTS CPVC PIPING AND FITTINGS. CSR SURGE TANK (MOUNT @ 7'-10" A.F.F.) WCH 3/4" COLD WATER LINE RUN DOWN IN WALL AND THEN UNDERGROUND. CONTINUE COLD WATER LINE UNDERGROUND TO WALL HYDRANT (WCH) LOCATED IN TRASH COMPOUND WALL. REFER TO TRASH COMPOUND SHEET A10. USE BLACK POLY. 1/2" CW UNSOFTENED WATER FOR FREESTYLE SYSTEM 2" CW BY-PASS NORMALLY CLOSED WCH PROVIDE WATER TANKER HOOK UP INSIDE WATER SERVICE ROOM. TIE IN BEFORE SOFTENER. 3/4"ø C W EWH-1 WATER SERVICE SHALL COME DIRECTLY INTO BUILDING WITH NO FITTING PER SITE ENGINEERING PLAN SE-1. (DEEP LONG SWEEP IS REQUIRED TO GET INTO BUILDING) 1 /2 "ø C W 3 /4 "ø C W 3 /4 "ø C W 1 "ø C W 1 1/2"ø CW 2"ø C W 1 /2 "ø C W 2 "ø C W 1 "ø H W 1"ø CW1"ø CWSA SA 1/2"ø TW1"ø CW1/2"ø TW3/4"ø CWSA SA 1/2"ø TW1/2"ø TW MX-1MX-1 3/4"ø CSRX3/4"ø CSR1/2"ø FW 1/2"ø FW1/2"ø CSRX1/2"ø FW1/2"ø CSRX1 /2 "ø F W 1 /2 "ø C S R X 1 /2 "ø C S R 1/2"ø CSR1/2"ø CSR3/4"ø CSRX1/2"ø CSR MX-1MX-1 3 /4 "ø C W MX-2 MX-2 MX-2 MX-2 MX-2 MX-2 BELOW SINK MX-2 BELOW SINK MX-2 BELOW SINK MX-2 MX-2 INSTALL SWINGING CHECK VALVE BEFORE MIXING VALVE ON THE HOT WATER PIPING (TYP.)1/2"ø HWR3/4"ø HW3/4"ø CW1/2"ø CSR1/2"ø HW 1/2"ø TW1/2"ø CW3/4"ø CSRX 3/4"ø CSRX1/2"ø TW1/2"ø CW3/4"ø CW3/4"ø HW3/4"ø CW1 1/2"ø HW3/4"ø HW1 /2 "ø C W 1/2"ø TW1/2"ø CW1 1/4"ø H W 1 /2 "ø H W 1 /2 "ø C W 1/2"ø HW3/4"ø CSR1/2"ø FW1/2"ø TW1/2"ø CW1 /2 "ø H W R 1/2"ø TW1/2"ø CW1/2"ø CW 1/2"ø TW 4" PVC SLEEVE PIPE FOR WATER HOOK UP. CAP BOTH ENDS. WC-1 WC-1 LAV-2 LAV-1 WC-1 LAV-2 UR-1 EWC-1 SRX FREESTYLE BOOSTER PUMP ON BIB RACK FREESTYLE FILTER MOUNTED TO WALL F5 F5 MR-1 F5 F3 F5 F5 F5 RP-1 CSR SYSTEM EQ C22 (FREESTYLE) 1/2" BALL VALVE 3/8" WATTS SD-3 EQ C28 (ICE MAKER) 1/2" BALL VALVE 3/8" WATTS SD-3 EQ C21 (ICED TEA) 1/2" BALL VALVE 3/8" WATTS SD-3 EQ C23 (FCB) 1/2" BALL VALVE 3/8" WATTS SD-3 EQ B40 (ESPRESSO) W/ FILTER 1/2" BALL VALVE 3/8" WATTS SD-3 EQ B37.1 (ICE MACHINE) 1/2" BALL VALVE 3/8" WATTS SD-3 EQ B29.1 (CAPPUCCINO) 1/2" BALL VALVE 3/8" WATTS SD-3 W/ 3/8" DRAIN TUBE (ROUTE VENT PORTS TO FS-5) EQ B26.2 (BREWER) 1/2" BALL VALVE 3/8" WATTS SD-3 W/ 3/8" DRAIN TUBE (ROUTE VENT PORTS TO FS-5) 1/2" CSR TO COLD BREW 1/2" CW TO SANITIZING EQUIPMENT (54" A.F.F.) B12.2 B9.1 1/2" CW AND CSRX WITH 3/4" MALE OUTLET TO EQ B42.2 BREAD OVEN3/4"ø CW1 1/2"ø CW 1"ø HW 3/4"ø HW 3/4"ø CW 1/2"ø CSRX 3/4"ø CSRX1/2"ø CSR 1 1 /2 "ø C W 1 1 /2 "ø C W3/4 "ø C W1/2 "ø H W R 3/4"ø HW 3/4"ø CW 1"ø CW 1 1/2"ø CW 1"ø H W 1/2"ø TW1/2"ø CW1 /2 "ø H W1/2 "ø C W1/2 "ø H W 1 /2 "ø H W 1 /2 "ø C W MW4 MW9.1 MW4 1/2"ø C W 1/2"ø CSRX 1/2"ø HW 1/2" HWR, 3/4" CSRX, 3/4" HW, 3/4" CW, & 1/2" CSR BELOW SLAB3/4"ø CSRXLAV-1 MW5.4 MX-2 BELOW SINK 1/2" HW & 1/2'' CW BELOW SLAB SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDDRAWNDATEPROJECT NO.COPYRIGHT © -All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service preparedby: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.4/16/2020 1:07:05 PMP4218071904-17-2020DJSJJDRISER DIAGRAMSORANGE AVE. & KINGS HWY, FT. PIERCE, FLWAWA260 WEST BALTIMORE PIKEWAWA, PENNSYLVANIA 19063WAWA F85FB 2020.00 STORE #5380-ORN04/17/2020 P4 1 SANITARY RISER P4 2 WATER RISER Revision ScheduleNo.DescriptionDatePERMIT SET04/17/2020