HomeMy WebLinkAboutEnvelopeCOMcheck Software Version 4.1.2.1
Envelope Compliance Certificate
Project Title:
2017 Florida Building Code, Energy Conservation
Project Type:New Construction
Vertical Glazing / Wall Area:19%
Location:Fort Pierce, Florida
Climate Zone:2a
Construction Site:
Orange Ave. & Kings Hwy.
Ft. Pierce, FL 34945
Owner/Agent:
Cuhaci & Peterson Architects
Engineers and Planners
1925 Prospect Ave.
Orlando, FL 32814
407-661-9100
Designer/Contractor:
Cuhaci & Peterson Architects
Engineers and Planners
1925 Prospect Ave.
Orlando, FL 32814
407-661-9100
Project Information
Energy Code:
Wawa - ORN - F85FB - 2180719
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.
Additional Efficiency Package(s)
Building Area Floor Area
1-Retail : Nonresidential 5831
Envelope Assemblies
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Roof 1: Insulation Entirely Above Deck: High Albedo Roof Required, 3-
Year-Aged Solar Reflectance = 0.68, Thermal Emittance = 0.83 (d),
[Bldg. Use 1 - Retail]
5836 ---40.0 0.025 0.039
Exterior Wall Front - Stone: Steel-Framed, 16" o.c., [Bldg. Use 1 -
Retail]
344 30.0 0.0 0.079 0.077
Storefront spandrel-front left: Metal Frame with Thermal Break:Fixed,
Perf. Specs.: Product ID N/A, SHGC 0.00, PF 0.55, [Bldg. Use 1 -
Retail] (b)
28 ------0.270 0.500
Storefront Entry Door: Glass (> 50% glazing):Metal Frame, Entrance
Door, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 0.55, [Bldg. Use 1 -
Retail] (b)
42 ------0.270 0.830
Exterior Wall Front - Lap Siding: Steel-Framed, 16" o.c., [Bldg. Use 1 -
Retail]
1064 30.0 0.0 0.079 0.077
Storefront windows-front clerestory 1,3: Metal Frame with Thermal
Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.11, [Bldg. Use 1 -
Retail] (b)
105 ------0.260 0.500
Storefront spandrel-front right: Metal Frame with Thermal Break:Fixed,
Perf. Specs.: Product ID N/A, SHGC 0.00, PF 0.55, [Bldg. Use 1 -
Retail] (b)
23 ------0.270 0.500
Storefront windows-front left: Metal Frame with Thermal Break:Fixed,
Perf. Specs.: Product ID N/A, SHGC 0.40, PF 0.55, [Bldg. Use 1 -
Retail] (b)
231 ------0.270 0.500
Storefront windows-front right: Metal Frame with Thermal Break:Fixed,
Perf. Specs.: Product ID N/A, SHGC 0.40, PF 1.98, [Bldg. Use 1 -
Retail] (b)
220 ------0.270 0.500
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
111 ofPage
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Exterior Wall Front - Stucco: Steel-Framed, 16" o.c., [Bldg. Use 1 -
Retail]
196 30.0 0.0 0.079 0.077
Storefront windows-front clerestory 2: Metal Frame with Thermal
Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.11, [Bldg. Use 1 -
Retail] (b)
36 ------0.260 0.500
Exterior Wall Left - Stone: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail]206 30.0 0.0 0.079 0.077
Exterior Wall Left - Lap Siding: Steel-Framed, 16" o.c., [Bldg. Use 1 -
Retail]
696 30.0 0.0 0.079 0.077
Storefront windows-left side: Metal Frame with Thermal Break:Fixed,
Perf. Specs.: Product ID N/A, SHGC 0.40, [Bldg. Use 1 - Retail] (b)
14 ------0.270 0.500
Exterior door type 3: Insulated Metal, Swinging, [Bldg. Use 1 - Retail]21 ------0.550 0.610
Exterior Wall Left - Stucco: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail]328 30.0 0.0 0.079 0.077
Exterior door type 1: Insulated Metal, Swinging, [Bldg. Use 1 - Retail]28 ------0.550 0.610
Exterior Wall Rear - Stone: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail]359 30.0 0.0 0.079 0.077
Storefront windows-rear: Metal Frame with Thermal Break:Fixed, Perf.
Specs.: Product ID N/A, SHGC 0.40, PF 0.36, [Bldg. Use 1 - Retail] (b)
57 ------0.270 0.500
Exterior Wall Rear - Lap Siding: Steel-Framed, 16" o.c., [Bldg. Use 1 -
Retail]
522 30.0 0.0 0.079 0.077
Exterior Wall Rear - Stucco: Steel-Framed, 16" o.c., [Bldg. Use 1 -
Retail]
639 30.0 0.0 0.079 0.077
Exterior Wall Right - Stone: Steel-Framed, 16" o.c., [Bldg. Use 1 -
Retail]
181 30.0 0.0 0.079 0.077
Exterior Wall Right - Lap Siding: Steel-Framed, 16" o.c., [Bldg. Use 1 -
Retail]
770 30.0 0.0 0.079 0.077
Storefront spandrel-right side-right: Metal Frame with Thermal
Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.00, PF 1.22, [Bldg.
Use 1 - Retail] (b)
52 ------0.270 0.500
Storefront windows-right side-right: Metal Frame with Thermal
Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 1.22, [Bldg.
Use 1 - Retail] (b)
134 ------0.270 0.500
Exterior door type 2: Insulated Metal, Swinging, [Bldg. Use 1 - Retail]24 ------0.550 0.610
Exterior Wall Right - Stucco: Steel-Framed, 16" o.c., [Bldg. Use 1 -
Retail]
229 30.0 0.0 0.079 0.077
Storefront windows-right side-left: Metal Frame with Thermal
Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 4.72, [Bldg.
Use 1 - Retail] (b)
99 ------0.270 0.500
Exterior Wall Angled front/right - Stone: Steel-Framed, 16" o.c., [Bldg.
Use 1 - Retail]
42 30.0 0.0 0.079 0.077
Storefront windows-Angled front/right: Metal Frame with Thermal
Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 1.80, [Bldg.
Use 1 - Retail] (b)
24 ------0.270 0.500
Exterior Wall Angled front/right - Lap Siding: Steel-Framed, 16" o.c.,
[Bldg. Use 1 - Retail]
40 30.0 0.0 0.079 0.077
Storefront spandrel-Angled front/right: Metal Frame with Thermal
Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.11, [Bldg. Use 1 -
Retail] (b)
10 ------0.260 0.500
Floor 1: Slab-On-Grade:Unheated, [Bldg. Use 1 - Retail] (c)324 ------0.730 0.730
(a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
(d)High albedo roof requirement options: 1) 3-year aged solar reflectance >= 0.55 thermal emittance >= 0.75, 2) 3-year aged solar reflectance
index >= 64.0, 3) Initial year aged solar reflectance >= 0.70 thermal emittance >= 0.75, 4) Initial year aged solar reflectance index >= 82.0.
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
112 ofPage
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.2.1 and to comply
with any applicable mandatory requirements listed in the Inspection Checklist.
Anthony D. Murphy, R.A.
Name - Title Signature Date
Envelope PASSES: Design 25% better than code
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
113 ofPage
04/17/2020
Inspection Checklist
Requirements: 0.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.1.2.1
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2017 Florida Building Code, Energy Conservation
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR1]1
Plans and/or specifications provide all
information with which compliance
can be determined for the building
envelope and document where
exceptions to the standard are
claimed.
Complies
Does Not
Not Observable
Not Applicable
C405.6
[PR17]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the electrical systems
and equipment and document where
exceptions are claimed. Provisions are
made for metering individual tenant
units. Feeder connectors (for feeder
and branch circuits) sized in
accordance with approved plans with
maximum drop of 5% voltage drop
total.
Complies
Does Not
Not Observable
Not Applicable
C402.4.1
[PR10]1
The vertical fenestration area <= 30
percent of the gross above-grade wall
area.
Complies
Does Not
Not Observable
Not Applicable
C402.4.1
[PR11]1
The skylight area <= 3 percent of the
gross roof area.
Complies
Does Not
Not Observable
Not Applicable
C402.4.2
[PR14]1
In enclosed spaces > 2,500 ft2
directly under a roof with ceiling
heights >15 ft. and used as an office,
lobby, atrium, concourse, corridor,
storage, gymnasium/exercise center,
convention center, automotive
service, manufacturing, non-
refrigerated warehouse, retail store,
distribution/sorting area,
transportation, or workshop, the
following requirements apply: (a) the
daylight zone under skylights is >=
half the floor area; (b) the skylight
area to daylight zone is >= 3 percent
with a skylight VT >= 0.40; or a
minimum skylight effective aperture
>= 1 percent.
Complies
Does Not
Not Observable
Not Applicable
C406
[PR9]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the additional energy
efficiency package options.
Complies
Does Not
Not Observable
Not Applicable
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
114 ofPage
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C402.5.9.(
1-4)
[PR16]1
Ceilings with vented dropped ceiling
cavities over conditioned spaces have
a continuous air barrier between the
conditioned space and the vented
unconditioned space and are sealed to
the air barrier of the walls. Unvented
dropped ceiling cavities over
conditioned spaces without air barrier
between the conditioned and
unconditioned space are sealed from
the exterior environment and adjacent
spaces by a continuous air barrier and
is sealed to the air barrier of the walls.
Unconditioned spaces above separate
tenancies contain dividing partitions
between the tenancies to form a
continuous air barrier that is sealed at
the ceiling and roof. Building cavities
designed to be air distribution system
components are sealed according to
the criteria for air ducts, plenums, etc.
in Section C403.2.7.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
115 ofPage
Section
#
& Req.ID
Footing / Foundation Inspection Complies?Comments/Assumptions
C303.2
[FO4]2
Slab edge insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C303.2.1
[FO6]1
Exterior insulation protected against
damage, sunlight, moisture, wind,
landscaping and equipment
maintenance activities.
Complies
Does Not
Not Observable
Not Applicable
C104
[FO3]2
Installed slab-on-grade insulation type
and R-value consistent with insulation
specifications reported in plans and
COMcheck reports.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.6
[FO12]3
Radiant heating systems panels
insulated to >=R-3.5 on face opposite
space being heated.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
116 ofPage
Section
#
& Req.ID
Framing / Rough-In Inspection Complies?Comments/Assumptions
C303.1.3
[FR12]2
Fenestration products rated in
accordance with NFRC.
Complies
Does Not
Not Observable
Not Applicable
C303.1.3
[FR13]1
Fenestration products are certified as
to performance labels or certificates
provided.
Complies
Does Not
Not Observable
Not Applicable
C402.4.3
[FR10]1
Vertical fenestration SHGC value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.3,
C402.4.3.
4
[FR8]1
Vertical fenestration U-Factor.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.4
[FR14]2
U-factor of opaque doors associated
with the building thermal envelope
meets requirements.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.5.1
[FR16]1
The building envelope contains a
continuous air barrier that is sealed in
an approved manner and either
constructed or tested in an approved
manner. Air barrier penetrations are
sealed in an approved manner.
Complies
Does Not
Not Observable
Not Applicable
C402.5.2,
C402.5.4
[FR18]3
Factory-built fenestration and doors
are labeled as meeting air leakage
requirements.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
117 ofPage
Section
#
& Req.ID
Mechanical Rough-In Inspection Complies?Comments/Assumptions
C402.5.5,
C403.2.4.
3
[ME3]3
Stair and elevator shaft vents have
motorized dampers that automatically
close.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
118 ofPage
Section
#
& Req.ID
Insulation Inspection Complies?Comments/Assumptions
C303.1
[IN3]1
Roof insulation installed per
manufacturer’s instructions. Blown or
poured loose-fill insulation is installed
only where the roof slope is <=3 in
12.
Complies
Does Not
Not Observable
Not Applicable
C303.1
[IN10]2
Building envelope insulation is labeled
with R-value or insulation certificate
providing R-value and other relevant
data.
Complies
Does Not
Not Observable
Not Applicable
C303.2
[IN7]1
Above-grade wall insulation installed
per manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C303.2.1
[IN14]2
Exterior insulation is protected from
damage with a protective material.
Verification for exposed foundation
insulation may need to occur during
Foundation Inspection.
Complies
Does Not
Not Observable
Not Applicable
C402.2.1
[IN17]3
Insulation intended to meet the roof
insulation requirements cannot be
installed on top of a suspended
ceiling. Mark this requirement
compliant if insulation is installed
accordingly.
Complies
Does Not
Not Observable
Not Applicable
C104
[IN6]1
Installed above-grade wall insulation
type and R-value consistent with
insulation specifications reported in
plans and COMcheck reports.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C104
[IN8]2
Installed floor insulation type and R-
value consistent with insulation
specifications reported in plans and
COMcheck reports.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.6
[IN18]3
Radiant panels and associated
components, designed for heat
transfer from the panel surfaces to the
occupants or indoor space are
insulated with a minimum of R-3.5.
Complies
Does Not
Not Observable
Not Applicable
C402.3
[IN5]3
High-albedo roofs satisfy one of the
following: 3-year-aged solar
reflectance >= 0.55 and thermal
emittance >= 0.75 or 3-year-aged
solar reflectance index >= 64.0.
Complies
Does Not
Not Observable
Not Applicable
C402.5.1.
1
[IN1]1
All sources of air leakage in the
building thermal envelope are sealed,
caulked, gasketed, weather stripped
or wrapped with moisture vapor-
permeable wrapping material to
minimize air leakage.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
119 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C402.5.3
[FI51]3
Where open combustion air ducts
provide combustion air to open
combustion fuel burning appliances,
the appliances and combustion air
opening are located outside the
building thermal envelope or enclosed
in a room, isolated from inside the
thermal envelope. Such rooms are
sealed and insulated.
Complies
Does Not
Not Observable
Not Applicable
C402.5.6
[FI37]1
Weatherseals installed on all loading
dock cargo doors.
Complies
Does Not
Not Observable
Not Applicable
C402.5.8
[FI26]3
Recessed luminaires in thermal
envelope to limit infiltration and be IC
rated and labeled. Seal between
interior finish and luminaire housing.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
1110 ofPage
Project Title:
Data filename:
Wawa - ORN - F85FB - 2180719
W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck
04/16/20Report date:
1111 ofPage