Loading...
HomeMy WebLinkAboutEnvelopeCOMcheck Software Version 4.1.2.1 Envelope Compliance Certificate Project Title: 2017 Florida Building Code, Energy Conservation Project Type:New Construction Vertical Glazing / Wall Area:19% Location:Fort Pierce, Florida Climate Zone:2a Construction Site: Orange Ave. & Kings Hwy. Ft. Pierce, FL 34945 Owner/Agent: Cuhaci & Peterson Architects Engineers and Planners 1925 Prospect Ave. Orlando, FL 32814 407-661-9100 Designer/Contractor: Cuhaci & Peterson Architects Engineers and Planners 1925 Prospect Ave. Orlando, FL 32814 407-661-9100 Project Information Energy Code: Wawa - ORN - F85FB - 2180719 Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Building Area Floor Area 1-Retail : Nonresidential 5831 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof 1: Insulation Entirely Above Deck: High Albedo Roof Required, 3- Year-Aged Solar Reflectance = 0.68, Thermal Emittance = 0.83 (d), [Bldg. Use 1 - Retail] 5836 ---40.0 0.025 0.039 Exterior Wall Front - Stone: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 344 30.0 0.0 0.079 0.077 Storefront spandrel-front left: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.00, PF 0.55, [Bldg. Use 1 - Retail] (b) 28 ------0.270 0.500 Storefront Entry Door: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 0.55, [Bldg. Use 1 - Retail] (b) 42 ------0.270 0.830 Exterior Wall Front - Lap Siding: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 1064 30.0 0.0 0.079 0.077 Storefront windows-front clerestory 1,3: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.11, [Bldg. Use 1 - Retail] (b) 105 ------0.260 0.500 Storefront spandrel-front right: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.00, PF 0.55, [Bldg. Use 1 - Retail] (b) 23 ------0.270 0.500 Storefront windows-front left: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 0.55, [Bldg. Use 1 - Retail] (b) 231 ------0.270 0.500 Storefront windows-front right: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 1.98, [Bldg. Use 1 - Retail] (b) 220 ------0.270 0.500 Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 111 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Exterior Wall Front - Stucco: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 196 30.0 0.0 0.079 0.077 Storefront windows-front clerestory 2: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.11, [Bldg. Use 1 - Retail] (b) 36 ------0.260 0.500 Exterior Wall Left - Stone: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail]206 30.0 0.0 0.079 0.077 Exterior Wall Left - Lap Siding: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 696 30.0 0.0 0.079 0.077 Storefront windows-left side: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.40, [Bldg. Use 1 - Retail] (b) 14 ------0.270 0.500 Exterior door type 3: Insulated Metal, Swinging, [Bldg. Use 1 - Retail]21 ------0.550 0.610 Exterior Wall Left - Stucco: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail]328 30.0 0.0 0.079 0.077 Exterior door type 1: Insulated Metal, Swinging, [Bldg. Use 1 - Retail]28 ------0.550 0.610 Exterior Wall Rear - Stone: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail]359 30.0 0.0 0.079 0.077 Storefront windows-rear: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 0.36, [Bldg. Use 1 - Retail] (b) 57 ------0.270 0.500 Exterior Wall Rear - Lap Siding: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 522 30.0 0.0 0.079 0.077 Exterior Wall Rear - Stucco: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 639 30.0 0.0 0.079 0.077 Exterior Wall Right - Stone: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 181 30.0 0.0 0.079 0.077 Exterior Wall Right - Lap Siding: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 770 30.0 0.0 0.079 0.077 Storefront spandrel-right side-right: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.00, PF 1.22, [Bldg. Use 1 - Retail] (b) 52 ------0.270 0.500 Storefront windows-right side-right: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 1.22, [Bldg. Use 1 - Retail] (b) 134 ------0.270 0.500 Exterior door type 2: Insulated Metal, Swinging, [Bldg. Use 1 - Retail]24 ------0.550 0.610 Exterior Wall Right - Stucco: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 229 30.0 0.0 0.079 0.077 Storefront windows-right side-left: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 4.72, [Bldg. Use 1 - Retail] (b) 99 ------0.270 0.500 Exterior Wall Angled front/right - Stone: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 42 30.0 0.0 0.079 0.077 Storefront windows-Angled front/right: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.40, PF 1.80, [Bldg. Use 1 - Retail] (b) 24 ------0.270 0.500 Exterior Wall Angled front/right - Lap Siding: Steel-Framed, 16" o.c., [Bldg. Use 1 - Retail] 40 30.0 0.0 0.079 0.077 Storefront spandrel-Angled front/right: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID N/A, SHGC 0.11, [Bldg. Use 1 - Retail] (b) 10 ------0.260 0.500 Floor 1: Slab-On-Grade:Unheated, [Bldg. Use 1 - Retail] (c)324 ------0.730 0.730 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. (d)High albedo roof requirement options: 1) 3-year aged solar reflectance >= 0.55 thermal emittance >= 0.75, 2) 3-year aged solar reflectance index >= 64.0, 3) Initial year aged solar reflectance >= 0.70 thermal emittance >= 0.75, 4) Initial year aged solar reflectance index >= 82.0. Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 112 ofPage Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.2.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Anthony D. Murphy, R.A. Name - Title Signature Date Envelope PASSES: Design 25% better than code Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 113 ofPage 04/17/2020 Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.2.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2017 Florida Building Code, Energy Conservation Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable C405.6 [PR17]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Provisions are made for metering individual tenant units. Feeder connectors (for feeder and branch circuits) sized in accordance with approved plans with maximum drop of 5% voltage drop total. Complies Does Not Not Observable Not Applicable C402.4.1 [PR10]1 The vertical fenestration area <= 30 percent of the gross above-grade wall area. Complies Does Not Not Observable Not Applicable C402.4.1 [PR11]1 The skylight area <= 3 percent of the gross roof area. Complies Does Not Not Observable Not Applicable C402.4.2 [PR14]1 In enclosed spaces > 2,500 ft2 directly under a roof with ceiling heights >15 ft. and used as an office, lobby, atrium, concourse, corridor, storage, gymnasium/exercise center, convention center, automotive service, manufacturing, non- refrigerated warehouse, retail store, distribution/sorting area, transportation, or workshop, the following requirements apply: (a) the daylight zone under skylights is >= half the floor area; (b) the skylight area to daylight zone is >= 3 percent with a skylight VT >= 0.40; or a minimum skylight effective aperture >= 1 percent. Complies Does Not Not Observable Not Applicable C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 114 ofPage Section # & Req.ID Plan Review Complies?Comments/Assumptions C402.5.9.( 1-4) [PR16]1 Ceilings with vented dropped ceiling cavities over conditioned spaces have a continuous air barrier between the conditioned space and the vented unconditioned space and are sealed to the air barrier of the walls. Unvented dropped ceiling cavities over conditioned spaces without air barrier between the conditioned and unconditioned space are sealed from the exterior environment and adjacent spaces by a continuous air barrier and is sealed to the air barrier of the walls. Unconditioned spaces above separate tenancies contain dividing partitions between the tenancies to form a continuous air barrier that is sealed at the ceiling and roof. Building cavities designed to be air distribution system components are sealed according to the criteria for air ducts, plenums, etc. in Section C403.2.7. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 115 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C303.2 [FO4]2 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.2.1 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable C104 [FO3]2 Installed slab-on-grade insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [FO12]3 Radiant heating systems panels insulated to >=R-3.5 on face opposite space being heated. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 116 ofPage Section # & Req.ID Framing / Rough-In Inspection Complies?Comments/Assumptions C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable C303.1.3 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable C402.4.3 [FR10]1 Vertical fenestration SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3, C402.4.3. 4 [FR8]1 Vertical fenestration U-Factor.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.4 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1 [FR16]1 The building envelope contains a continuous air barrier that is sealed in an approved manner and either constructed or tested in an approved manner. Air barrier penetrations are sealed in an approved manner. Complies Does Not Not Observable Not Applicable C402.5.2, C402.5.4 [FR18]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 117 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.5.5, C403.2.4. 3 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 118 ofPage Section # & Req.ID Insulation Inspection Complies?Comments/Assumptions C303.1 [IN3]1 Roof insulation installed per manufacturer’s instructions. Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. Complies Does Not Not Observable Not Applicable C303.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.2.1 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable C402.2.1 [IN17]3 Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Complies Does Not Not Observable Not Applicable C104 [IN6]1 Installed above-grade wall insulation type and R-value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C104 [IN8]2 Installed floor insulation type and R- value consistent with insulation specifications reported in plans and COMcheck reports. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [IN18]3 Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Complies Does Not Not Observable Not Applicable C402.3 [IN5]3 High-albedo roofs satisfy one of the following: 3-year-aged solar reflectance >= 0.55 and thermal emittance >= 0.75 or 3-year-aged solar reflectance index >= 64.0. Complies Does Not Not Observable Not Applicable C402.5.1. 1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor- permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 119 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C402.5.3 [FI51]3 Where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening are located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms are sealed and insulated. Complies Does Not Not Observable Not Applicable C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo doors. Complies Does Not Not Observable Not Applicable C402.5.8 [FI26]3 Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 1110 ofPage Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 1111 ofPage