Loading...
HomeMy WebLinkAboutMechanicalCOMcheck Software Version 4.1.2.1 Mechanical Compliance Certificate Project Title: 2017 Florida Building Code, Energy Conservation Project Type:New Construction Location:Fort Pierce, Florida Climate Zone:2a Construction Site: Orange Ave. & Kings Hwy. Ft. Pierce, FL 34945 Owner/Agent: Cuhaci & Peterson Architects Engineers and Planners 1925 Prospect Ave. Orlando, FL 32814 407-661-9100 Designer/Contractor: Cuhaci & Peterson Architects Engineers and Planners 1925 Prospect Ave. Orlando, FL 32814 407-661-9100 Project Information Energy Code: Wawa - ORN - F85FB - 2180719 Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Mechanical Systems List Quantity System Type & Description Heating: 1 each - Central Furnace, Electric, Capacity = 25 kBtu/h No minimum efficiency requirement applies Cooling: 1 each - Single Package DX Unit, Capacity = 102 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: Humidity Requirements Proposed Efficiency = 12.40 EER, Required Efficiency: 11.20 EER + 12.8 IEER Fan System: FAN SYSTEM 1 | RTU-1 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 1 Supply, Constant Volume, 3375 CFM, 2.0 motor nameplate hp, 0.0 fan efficiency grade 1 HVAC System RTU-1 (Single Zone): Cooling: 1 each - Single Package DX Unit, Capacity = 120 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: Humidity Requirements Proposed Efficiency = 12.20 EER, Required Efficiency: 11.20 EER + 12.8 IEER Fan System: FAN SYSTEM 2 | RTU-2 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 2 Supply, Constant Volume, 4800 CFM, 5.0 motor nameplate hp, 0.0 fan efficiency grade EF 1 Exhaust, Constant Volume, 200 CFM, 0.1 motor nameplate hp, 0.0 fan efficiency grade EF 3 Exhaust, Constant Volume, 100 CFM, 0.1 motor nameplate hp, 0.0 fan efficiency grade 1 HVAC System RTU-2 (Single Zone): Heating: 1 each - Central Furnace, Electric, Capacity = 25 kBtu/h No minimum efficiency requirement applies Cooling: 1 each - Single Package DX Unit, Capacity = 92 kBtu/h, Air-Cooled Condenser, No Economizer, Economizer exception: Humidity Requirements Proposed Efficiency = 12.70 EER, Required Efficiency: 11.20 EER + 12.8 IEER Fan System: FAN SYSTEM 3 | RTU-3 -- Compliance (Motor nameplate HP method) : Passes Fans: FAN 3 Supply, Constant Volume, 2700 CFM, 2.0 motor nameplate hp, 0.0 fan efficiency grade EF 2 Exhaust, Constant Volume, 60 CFM, 0.0 motor nameplate hp, 0.0 fan efficiency grade 1 HVAC System RTU-3 (Single Zone): Electric Storage Water Heater, Capacity: 50 gallons w/ Circulation Pump Proposed Efficiency: 0.86 EF, Required Efficiency: 0.86 EF 1 Water Heater 1: Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 131 ofPage Quantity System Type & Description Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.2.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Jose J.Diaz-Velazquez, P.E. Name - Title Signature Date Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 132 ofPage 04/17/2020 Air System Sizing Summary for RTU-1 Project Name: 2180719-Wawa #ORN (F85-FB) v2020.00 04/06/2020 Prepared by: Cuhaci and Peterson Architects 12:30PM Air System Information Air System Name RTU-1 Equipment Class PKG ROOF Air System Type SZCAV Number of zones 1 Floor Area 2574.0 ft² Location Fort Pierce, Florida Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone CFM Sizing Peak zone sensible load Space CFM Sizing Coincident space loads Central Cooling Coil Sizing Data Total coil load 8.5 Tons Total coil load 102.5 MBH Sensible coil load 77.1 MBH Coil CFM at Oct 1400 3360 CFM Max block CFM 3360 CFM Sum of peak zone CFM 3360 CFM Sensible heat ratio 0.752 CFM/Ton 393.4 ft²/Ton 301.3 BTU/(hr·ft²) 39.8 Water flow @ 10.0 °F rise N/A Load occurs at Oct 1400 OA DB / WB 86.6 / 75.9 °F Entering DB / WB 76.4 / 64.5 °F Leaving DB / WB 55.1 / 54.1 °F Coil ADP 52.8 °F Bypass Factor 0.100 Resulting RH 50 % Design supply temp. 55.0 °F Zone T-stat Check 1 of 1 OK Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil load 21.0 MBH Coil CFM at Des Htg 3360 CFM Max coil CFM 3360 CFM Water flow @ 20.0 °F drop N/A Load occurs at Des Htg BTU/(hr·ft²) 8.1 Ent. DB / Lvg DB 66.1 / 71.9 °F Supply Fan Sizing Data Actual max CFM 3360 CFM Standard CFM 3358 CFM Actual max CFM/ft² 1.31 CFM/ft² Fan motor BHP 0.92 BHP Fan motor kW 0.73 kW Fan static 1.00 in wg Outdoor Ventilation Air Data Design airflow CFM 490 CFM CFM/ft² 0.19 CFM/ft² CFM/person 11.08 CFM/person Hourly Analysis Program 5.11 Page 1 of 3 Air System Sizing Summary for RTU-2 Project Name: 2180719-Wawa #ORN (F85-FB) v2020.00 04/06/2020 Prepared by: Cuhaci and Peterson Architects 12:30PM Air System Information Air System Name RTU-2 Equipment Class PKG ROOF Air System Type SZCAV Number of zones 1 Floor Area 930.0 ft² Location Fort Pierce, Florida Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone CFM Sizing Peak zone sensible load Space CFM Sizing Coincident space loads Central Cooling Coil Sizing Data Total coil load 10.1 Tons Total coil load 121.6 MBH Sensible coil load 107.9 MBH Coil CFM at Jul 1500 4934 CFM Max block CFM at Jul 1500 4934 CFM Sum of peak zone CFM 4934 CFM Sensible heat ratio 0.888 CFM/Ton 487.0 ft²/Ton 91.8 BTU/(hr·ft²) 130.7 Water flow @ 10.0 °F rise N/A Load occurs at Jul 1500 OA DB / WB 91.0 / 78.0 °F Entering DB / WB 75.9 / 63.0 °F Leaving DB / WB 55.7 / 54.5 °F Coil ADP 53.4 °F Bypass Factor 0.100 Resulting RH 48 % Design supply temp. 55.0 °F Zone T-stat Check 0 of 1 OK Max zone temperature deviation 0.3 °F Supply Fan Sizing Data Actual max CFM at Jul 1500 4934 CFM Standard CFM 4930 CFM Actual max CFM/ft² 5.30 CFM/ft² Fan motor BHP 1.35 BHP Fan motor kW 1.07 kW Fan static 1.00 in wg Outdoor Ventilation Air Data Design airflow CFM 183 CFM CFM/ft² 0.20 CFM/ft² CFM/person 36.67 CFM/person Hourly Analysis Program 5.11 Page 2 of 3 Air System Sizing Summary for RTU-3 Project Name: 2180719-Wawa #ORN (F85-FB) v2020.00 04/06/2020 Prepared by: Cuhaci and Peterson Architects 12:30PM Air System Information Air System Name RTU-3 Equipment Class PKG ROOF Air System Type SZCAV Number of zones 1 Floor Area 1295.0 ft² Location Fort Pierce, Florida Sizing Calculation Information Calculation Months Jan to Dec Sizing Data Calculated Zone CFM Sizing Peak zone sensible load Space CFM Sizing Coincident space loads Central Cooling Coil Sizing Data Total coil load 6.5 Tons Total coil load 78.3 MBH Sensible coil load 57.3 MBH Coil CFM at Nov 1400 2508 CFM Max block CFM 2508 CFM Sum of peak zone CFM 2508 CFM Sensible heat ratio 0.732 CFM/Ton 384.5 ft²/Ton 198.6 BTU/(hr·ft²) 60.4 Water flow @ 10.0 °F rise N/A Load occurs at Nov 1400 OA DB / WB 83.6 / 74.9 °F Entering DB / WB 76.0 / 64.5 °F Leaving DB / WB 54.8 / 53.8 °F Coil ADP 52.5 °F Bypass Factor 0.100 Resulting RH 50 % Design supply temp. 55.0 °F Zone T-stat Check 1 of 1 OK Max zone temperature deviation 0.0 °F Central Heating Coil Sizing Data Max coil load 18.7 MBH Coil CFM at Des Htg 2508 CFM Max coil CFM 2508 CFM Water flow @ 20.0 °F drop N/A Load occurs at Des Htg BTU/(hr·ft²) 14.4 Ent. DB / Lvg DB 65.8 / 72.7 °F Supply Fan Sizing Data Actual max CFM 2508 CFM Standard CFM 2506 CFM Actual max CFM/ft² 1.94 CFM/ft² Fan motor BHP 0.69 BHP Fan motor kW 0.54 kW Fan static 1.00 in wg Outdoor Ventilation Air Data Design airflow CFM 400 CFM CFM/ft² 0.31 CFM/ft² CFM/person 26.67 CFM/person Hourly Analysis Program 5.11 Page 3 of 3 Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.2.1 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2017 Florida Building Code, Energy Conservation Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR2]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. Complies Does Not Not Observable Not Applicable C103.2 [PR3]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. Complies Does Not Not Observable Not Applicable C405.6 [PR17]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Provisions are made for metering individual tenant units. Feeder connectors (for feeder and branch circuits) sized in accordance with approved plans with maximum drop of 5% voltage drop total. Complies Does Not Not Observable Not Applicable C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 133 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C402.2.6 [FO12]3 Radiant heating systems panels insulated to >=R-3.5 on face opposite space being heated. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C403.2.4. 5, C403.2.4. 6 [FO9]3 Snow/ice melting system sensors for future connection to controls. Freeze protection systems have automatic controls installed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 134 ofPage Section # & Req.ID Plumbing Rough-In Inspection Complies?Comments/Assumptions C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable C404.5, C404.5.1, C404.5.2 [PL6]3 Heated water supply piping conforms to pipe length and volume requirements. Refer to section details. Complies Does Not Not Observable Not Applicable C404.6.1, C404.6.2 [PL3]1 Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. Complies Does Not Not Observable Not Applicable C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable C404.6.3 [PL7]3 Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to <= 5 minutes after end of heating cycle. Complies Does Not Not Observable Not Applicable C404.7 [PL8]3 Water distribution system that pumps water from a heated-water supply pipe back to the heated-water source through a cold-water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 135 ofPage Section # & Req.ID Plumbing Rough-In Inspection Complies?Comments/Assumptions C404.7 [PL8]3 Water distribution system that pumps water from a heated-water supply pipe back to the heated-water source through a cold-water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable C404.7 [PL8]3 Water distribution system that pumps water from a heated-water supply pipe back to the heated-water source through a cold-water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable C404.7 [PL8]3 Water distribution system that pumps water from a heated-water supply pipe back to the heated-water source through a cold-water supply pipe is a demand recirculation water system. Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 136 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.2.6 [ME41]3 Thermally ineffective panel surfaces of sensible heating panels have insulation >= R-3.5. Complies Does Not Not Observable Not Applicable C403.2.9. 1.1 [ME60]2 HVAC ducts and plenums insulated and sealed according to Florida Section C403.2.9, Table C403.2.9.1. Complies Does Not Not Observable Not Applicable C403.2.9. 2 [ME79]2 All ducts, air handlers, filter boxes, building cavities, mechanical closets and enclosed support platforms that form the primary air containment passageways for air distribution systems are constructed and erected in accordance with Table C403.2.9.2 and with Chapter 6 of the Florida Building Code, Mechanical. Ducts are be constructed, braced, reinforced and installed to provide structural strength and durability. All transverse joints, longitudinal seams and fitting connections are securely fastened in accordance with the applicable standards of this section. Complies Does Not Not Observable Not Applicable C403.2.9. 1.2 [ME80]2 Duct insulation is protected from damage but not limited to the following: 1. Insulation exposed to weather is suitable for outdoor service. Cellular foam insulation is protected or painted with a coating that is water retardant and provides shielding from solar radiation. 2. Insulation covering cooling ducts located outside the conditioned space is vapor retardant located outside the insulation, all penetrations and joints of which shall be sealed. Complies Does Not Not Observable Not Applicable C403.2.9. 1.3 [ME81]2 Additional insulation with vapor barrier is provided where the minimum duct insulation requirements of Section C403.2.9.1.1 are determined to be insufficient to prevent condensation. Complies Does Not Not Observable Not Applicable C403.2.13 [ME71]2 Unenclosed spaces that are heated use only radiant heat. Complies Does Not Not Observable Not Applicable C403.2.3 [ME55]2 HVAC equipment efficiency verified.Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C403.2.9. 3 [ME10]2 Ducts, air handlers, filter boxes, building cavities, mechanical closets and enclosed support platforms that form the primary air containment passageways for air distribution systems are sealed in accordance with the applicable criteria of this section and Table C403.2.9.2. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 137 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C403.2.9. 4 [ME78]2 Cavities in framed spaces are not used to deliver air from or return air to the conditioning system unless they contain an air duct insert which is insulated in accordance with Section C403.2.9.1 and constructed and sealed in accordance with the requirements of Section C403.2.9.2 appropriate for the duct materials used. Complies Does Not Not Observable Not Applicable C403.2.9. 5 [ME76]2 Air distribution systems are sized and designed in accordance with recognized engineering standards. Refer to section details. Complies Does Not Not Observable Not Applicable C403.2.9. 6 [ME77]2 Air-handling units not installed in attics of commercial buildings. Complies Does Not Not Observable Not Applicable C408.2.2. 1 [ME53]3 Air system balancing accomplished in a manner to first minimize throttling losses, then for fans with fan system power greater than 1 hp, fan speeds shall be adjusted to meet design flow conditions. Balancing procedures shall be in accordance with NEBB Procedural Standards, the AABC, National Standards, or equivalent procedures. Complies Does Not Not Observable Not Applicable C403.2.6. 1 [ME59]1 Demand control ventilation provided for spaces >500 ft2 and >25 people/1000 ft2 occupant density and served by systems with air side economizer, auto modulating outside air damper control, or design airflow >3,000 cfm. Complies Does Not Not Observable Not Applicable C403.2.6. 2 [ME115]3 Enclosed parking garage ventilation has automatic contaminant detection and capacity to stage or modulate fans to 50% or less of design capacity. Complies Does Not Not Observable Not Applicable C403.2.7 [ME57]1 Exhaust air energy recovery on systems meeting Table C403.2.7(1) and C403.2.7(2). Complies Does Not Not Observable Not Applicable C403.2.8 [ME116]3 Kitchen exhaust systems comply with replacement air and conditioned supply air limitations, and satisfy hood rating requirements and maximum exhaust rate criteria. Complies Does Not Not Observable Not Applicable C403.4.4. 6 [ME110]3 Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C403.4.4. 6 [ME110]3 Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 138 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C403.4.4. 6 [ME110]3 Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. Complies Does Not Not Observable Not Applicable See the Mechanical Systems list for values. C408.2.2. 1 [ME53]3 Air outlets and zone terminal devices have means for air balancing. Complies Does Not Not Observable Not Applicable C403.5, C403.5.1, C403.5.2 [ME123]3 Refrigerated display cases, walk-in coolers or walk-in freezers served by remote compressors and remote condensers not located in a condensing unit, have fan-powered condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Complies Does Not Not Observable Not Applicable C403.5.3 [ME124]3 Condensing coils installed in cool air stream of another air-conditioning unit. The condensing coil of one air- conditioning unit shall not be installed in the cool air stream of another air- conditioning unit. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 139 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 3 [FI8]3 Furnished O&M manuals for HVAC systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C403.2.4. 2.4 [FI56]3 Minimum one humidity control device per installed humidification/dehumidification system. Controls prevent simultaneous operation of humidification and dehumidification equipment. Complies Does Not Not Observable Not Applicable C403.2.4. 2.4 [FI56]3 Minimum one humidity control device per installed humidification/dehumidification system. Controls prevent simultaneous operation of humidification and dehumidification equipment. Complies Does Not Not Observable Not Applicable C403.2.4. 2.4 [FI56]3 Minimum one humidity control device per installed humidification/dehumidification system. Controls prevent simultaneous operation of humidification and dehumidification equipment. Complies Does Not Not Observable Not Applicable C403.2.1 [FI50]3 HVAC systems and equipment design loads calculated in accordance with ANSI/ASHRAE/ACCA Standard 183 or ACCA Manual N or by an approved equivalent computational procedure. Design loads shall be attached to the code compliance form submitted to the building department when the building is permitted or, in the event the mechanical permit is obtained at a later time, the sizing calculation shall be submitted with the application for the mechanical permit. Complies Does Not Not Observable Not Applicable C403.2.2 [FI27]3 HVAC systems and equipment capacity does not exceed calculated loads. Complies Does Not Not Observable Not Applicable C403.2.4. 1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable C403.2.4. 1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable C403.2.4. 1 [FI47]3 Heating and cooling to each zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 1310 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C403.2.4. 1.2 [FI38]3 Thermostatic controls have a 5 °F deadband. Complies Does Not Not Observable Not Applicable C403.2.4. 1.3 [FI20]3 Temperature controls have setpoint overlap restrictions. Complies Does Not Not Observable Not Applicable C403.2.4. 2 [FI39]3 Each zone equipped with setback controls using automatic time clock or programmable control system. Complies Does Not Not Observable Not Applicable C404.12.2 [FI53]3 Public lavatory facilities equipped with outlet devices which limit the flow of hot water to a maximum of 0.5 gpm or are equipped with self-closing valves that limit delivery to a per cycle maximum of 0.25 gallons of hot water for recirculating systems and to a maximum of 0.50 gallons for non- recirculating systems. Complies Does Not Not Observable Not Applicable C404.12.2 [FI57]3 Public lavatory water temperature <=110°F. Complies Does Not Not Observable Not Applicable C404.12.1 [FI52]3 Showers used for non-safety reasons equipped with flow control devices to limit the water discharge to a maximum of 2.5 gpm per shower head. Flow restricting inserts used as a component part of a showerhead are mechanically retained at the point of manufacture Complies Does Not Not Observable Not Applicable C408.2.2 [FI54]3 Construction documents require that a written balance report be provided to the building owner or rep for HVAC systems serving zones with total condition area > 5,000 sqft. Air distribution systems shall be tested, adjusted, and balanced by a licensed engineer or certified company. Complies Does Not Not Observable Not Applicable C403.2.4. 2.1, C403.2.4. 2.2 [FI40]3 Automatic Controls: Setback to 55°F (heat) and 85°F (cool); 7-day clock, 2- hour occupant override, 10-hour backup Complies Does Not Not Observable Not Applicable C403.2.4. 2.3 [FI41]3 Systems include optimum start controls. Complies Does Not Not Observable Not Applicable C403.2.4. 2.3 [FI41]3 Systems include optimum start controls. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 1311 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C403.2.4. 2.3 [FI41]3 Systems include optimum start controls. Complies Does Not Not Observable Not Applicable C404.3 [FI11]3 Heat traps installed on supply and discharge piping of non-circulating systems. Complies Does Not Not Observable Not Applicable C404.4 [FI25]2 All piping insulated in accordance with section details and Table C403.2.10. Complies Does Not Not Observable Not Applicable C404.6.1 [FI12]3 Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank. System return pipe is a dedicated return pipe or a cold water supply pipe. Complies Does Not Not Observable Not Applicable C408.2.1 [FI28]1 Commissioning plan developed by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable C408.2.3. 1 [FI31]1 HVAC equipment has been tested to ensure proper operation. Complies Does Not Not Observable Not Applicable C408.2.3. 2 [FI10]1 HVAC control systems have been tested to ensure proper operation, calibration and adjustment of controls. Complies Does Not Not Observable Not Applicable C408.2.4 [FI29]1 Preliminary commissioning report completed and certified by registered design professional or approved agency. Complies Does Not Not Observable Not Applicable C408.2.5. 1 [FI7]3 Furnished HVAC as-built drawings submitted within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable C408.2.5. 3 [FI43]1 An air and/or hydronic system balancing report is provided for HVAC systems. Complies Does Not Not Observable Not Applicable C408.2.5. 4 [FI30]1 Final commissioning report due to building owner within 90 days of receipt of certificate of occupancy. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 1312 ofPage Project Title: Data filename: Wawa - ORN - F85FB - 2180719 W:\2018\2180719\HVAC Calcs\Energy Calcs\F85-FB-v2020.00-(FL)_2017 IECC.cck 04/16/20Report date: 1313 ofPage