HomeMy WebLinkAbout01-Ceco Doors (FL10723.1-R6)BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL10723-R6
Application Type Revision
Code Version 2017
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer Ceco Door Products
Address/Phone/Email 9159 Telecom Drive
Milan, TN 38358
(731) 686-4370
jbadgett@cecodoor.com
Authorized Signature Jeff Badgett
jbadgett@cecodoor.com
Technical Representative Dwayne Charlton
Address/Phone/Email 9519 Telcom
Milan, TN 38358
(731) 686-4282
dcharlton@cecodoor.com
Quality Assurance Representative John Wilkinson
Address/Phone/Email 9159 Telcom Dri
Milan, TN 38358
(731) 686-4385
jwilkinson@cecodoor.com
Category Exterior Doors
Subcategory Exterior Door Components
Compliance Method Certification Mark or Listing
Certification Agency Intertek Testing Services NA, Inc.
Validated By Ted Berman, PE
Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard)Standard Year
ASTM E1886 2005
ASTM E1996 2009
ASTM E330 2002
TAS-201 1994
TAS-202 1994
TAS-203 1994
Equivalence of Product Standards
Certified By Approved Certification Agency
FL10723_R6_Equiv_2017-11-14 Assa Abloy 103303430COQ-001
Equivalency Letter.pdf
Page 1 of 2Florida Building Code Online
2/9/2018https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv1dAvIteOYO0...
Product Approval Method Method 1 Option A
Date Submitted 10/23/2017
Date Validated 11/21/2017
Date Pending FBC Approval
Date Approved 11/21/2017
Summary of Products
FL #Model, Number or Name Description
10723.1 Swinging Hollow Metal Doors and
Frame Products
Doors: Trio, Trio-E, Regent (Omega), Medallion, Legion
(Ultra), Imperial (Versadoor), Fuego & Mercury. Frame
Products: KD or Welded Three Piece Frames, Sidelight
Frames, Transom Frames & Window Frames.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Design Pressure: +100(Max)/-100(Max)
Other: Design pressure varies by size and application.
Inswing and Outswing, singles and pairs of hollow metal
doors and frames as listed with Intertek-ETL/Warnock
Hersey. See WH Frame Installation Instructions for water
infiltration requirements.
Certification Agency Certificate
FL10723_R6_C_CAC_2017-10-17 - Florida Product Approval
Letter - Ceco Door Products.pdf
FL10723_R6_C_CAC_SDReport_171018204013 IA Door
Mfg.pdf
FL10723_R6_C_CAC_SDReport_171018205350 IVA
Frame.pdf
Quality Assurance Contract Expiration Date
12/31/2022
Installation Instructions
FL10723_R6_II_WH Door Installation Instructions
10_18_17 (R1).pdf
FL10723_R6_II_WH Frame Installation Instructions
10_18_17.pdf
Verified By: Intertek Testing Services NA, Inc.
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
Page 2 of 2Florida Building Code Online
2/9/2018https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv1dAvIteOYO0...
545 East Algonquin Road
Arlington Heights, IL 60005
Telephone: +1 847 439 5667
Facsimile: +1 866 262 2753
www.intertek.com
October 17, 2017
RE Intertek QA Inspections for Ceco Door Products – FL10723
To Whom it May Concern,
This letter is in response to your request for verification on a QA contract between Ceco Door Products
and Intertek for the product covered by Florida Product Approval Number FL10723.
Inspections for FL10723 occur at the location below:
Assa Abloy Service Center – Garland, TX
Ceco Door Products – Milan, TN
Please note, the QA contract bears no expiration date and as such does not expire except upon its
termination.
Should you need anything further, please do not hesitate to contact Intertek.
Sincerely,
Michael Puls
Engineer/Intertek Inspection Manager
AUTHORIZATION TO MARK
This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section
when made in accordance with the conditions set forth in the Certification Agreement and Listing Report(s). This authorization also
applies to the Multiple Listee model(s) identified on the correlation page of the Listing Report.
This document is the property of Intertek Testing Services and is not transferable. The Certification Mark(s) may be applied only at
the location of the Party Authorized to Apply Mark.
Applicant: Ceco Door Products (Milan)
9159 Telecom Drive
Milan, TN 38358
Country:
Contact: Dwayne Charlton
Phone: 731-686-4282
Fax: 731-723-1310
Email: dcharlton@cecodoor.com
Party Authorized to Apply Mark: See following page(s)
Evaluation Center: Intertek (Middleton)
Control/Client Number: 242757
This document supersedes all previous Authorizations to Mark for the noted Report Number.
This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability
are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage
occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s
Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in
accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.
Testing Standard(s): ASTM E330 (2002), ASTM E331 (2000), ASTM E1886 (2002), ASTM
E1996 (2003), ANSI A250.13 (2003), TAS 203, ASTM E330 (2014),
ASTM E1996 (R2014), ASTM E1886 (R2013), ANSI A250.13 (R2014),
ASTM E331 (2016), TAS 201, TAS 202, ASTM E1886 (2005), ANSI
A250.13 (2005), ASTM E1996 (2008), ASTM E331 (2009),
Product: Ceco Volume IA Windstorm Doors - Manufacturing
ATM for Report: 3118505, 3126983, 3132419-001, 3159480, 3159865,
3163505, 3190362MID-002, Letter Report 100407338, 100407338MID-
003, Letter Report 100545411, 100545411MID-003, Letter Report
100859994, 100859994MID-003, 101343015MID-001, 101274930MID-
ATM Issue Date: 09/07/2017
Report prepared for: Justin Hendricks (Intertek) on 10/18/2017 8:40:16 PM
Ceco Door Products (Milan) | 28766 | Rev: Sep 7 2017 10:17AM | Uncontrolled Copy Page 1 of 4
003, 101274930MID-004, 102016058MID-001, 102349537MID-001,
102750916MID-003, 103009100MID-001
Report prepared for: Justin Hendricks (Intertek) on 10/18/2017 8:40:16 PM
Ceco Door Products (Milan) | 28766 | Rev: Sep 7 2017 10:17AM | Uncontrolled Copy Page 2 of 4
AUTHORIZATION TO MARK
This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section
when made in accordance with the conditions set forth in the Certification Agreement and Listing Report(s). This authorization also
applies to the Multiple Listee model(s) identified on the correlation page of the Listing Report.
This document is the property of Intertek Testing Services and is not transferable. The Certification Mark(s) may be applied only at
the location of the Party Authorized to Apply Mark.
Applicant: Ceco Door Products (Milan)
9159 Telecom Drive
Milan, TN 38358
Country:
Contact: Dwayne Charlton
Phone: 731-686-4282
Fax: 731-723-1310
Email: dcharlton@cecodoor.com
Party Authorized to Apply Mark: See following page(s)
Evaluation Center: Intertek (Middleton)
Control/Client Number: 242757
This document supersedes all previous Authorizations to Mark for the noted Report Number.
This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client. Intertek's responsibility and liability
are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage
occasioned by the use of this Authorization to Mark. Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety. Use of Intertek’s
Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark. Any further use of the Intertek name for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in
accordance with the agreement, they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect.
Testing Standard(s): ASTM E330 (2002), ASTM E331 (2000), ASTM E1886 (2002), ASTM
E1996 (2003), ANSI A250.13 (2003), TAS 203, TAS 201, TAS 202,
ASTM E1886 (2005), ASTM E1996 (2008), ASTM E331 (2009),
Product: Ceco Volume IVA - Windstorm Frame Specs
ATM for Report: 3118505, 3126983, 3159480, 3159865, 3163505,
3190362MID-002, Letter Report 100407338, 100407338MID-003, Letter
Report 100545411, 100545411MID-003, Letter Report 100859994,
100859994MID-003, 101343015MID-001, 101274930MID-003,
101274930MID-004, 102050876MID-001
ATM Issue Date: 07/25/2017
Report prepared for: Justin Hendricks (Intertek) on 10/18/2017 8:53:54 PM
Ceco Door Products (Milan) | 28767 | Rev: Jul 25 2017 3:43PM | Uncontrolled Copy Page 1 of 8
Windstorm Door Installation Instructions
For Use With FL10723
Page 1 of 20
*Glass lights may limit design loads. See details to follow for additional information.
**Louvers are excluded from use with Trio and Trio-E Doors.
Medallion
Legion
Ultra
Regent
Omega
Medallion
Legion
Ultra
Regent
Omega
Fuego
Legion
Ultra
Regent
Omega
Fuego
Medallion
Legion
Ultra
Regent
Omega
Fuego
Medallion
Legion
Ultra
Regent
Omega
Fuego
Medallion
Legion
Ultra
Regent
Omega
Fuego
Medallion
Inswing/
Outswing
Inswing/
Outswing
30 x 70
Single
30 x 70
Single
Mortise Lock (Latchbolt +
Deadbolt) - Active
+ Surface Bolts- Inactive
Mortise Lock (Latchbolt +
Deadbolt), Rim Exit Device,
Vertical Rod Exit Device
Mortise Lock (Latchbolt +
Deadbolt) - Active
+ Surface Bolts- Inactive
Rim Exit Devices +
Mullion
Cylindrical = ½”
Mortise = ¾” Latchbolt
Cylindrical = ½” + Deadbolt = 1”
Mortise = ¾” LatchBolt + 1”
Deadbolt
InterConnected Lock = ½”
LatchBolt + 1” Deadbolt
Mortise = ¾” Latchbolt + 1”
Deadbolt
Rim Exit Device, Vertical Rod Exit
Device= N/A
Cylindrical = ½”
Mortise = ¾” Latchbolt,
Mortise Exit Device, Rim Exit
Device, Vertical Rod
Exit Device = N/A
Mortise = ¾” Latchbolt + 1”
Deadbolt
Rim Exit Device, Vertical Rod Exit
Device= N/A
Mortise = ¾” Latchbolt + 1”
Deadbolt
Surface Bolt = 1¼”
Rim Exit Device = N/A
Mortise = ¾” Latchbolt + 1”
Deadbolt
Surface Bolt = 1¼”
1120
Outswing 16 +/- 70 1120
80 x 80
Pair
80 x 80
Pair
Outswing 16 +/- 70
Outswing 16 +/- 70 112040 x 80
Single
Mortise Lock (Latchbolt +
Deadbolt), Rim Exit Device,
Vertical Rod Exit Device
Outswing 18 +/- 60 630
Cylindrical Lock, Mortise
Lock (Latchbolt), Mortise
Exit Device, Rim Exit
Device, Vertical Rod Exit
Device
30 x 80
Single
30 x 70
Single
Outswing 18 +/- 60 720
18 +/- 70 735
Cylindrical Lock + Deadbolt,
Mortise Lock (LatchBolt +
DeadBolt), Interconnected
Lock
18 +/- 60 630 Cylindrical Lock, Mortise
Lock (Latchbolt)
Stiffness Class I Impact 350 ft-lbs
Door Type Configuration
Max.
Size Min. Latch Throw (in)
Lock Side - Min.
Latch Strength
(lbf)
Hardware TypeMin.
Gauge
*Max.
Design
Load (psf)
Windstorm Door Installation Instructions
For Use With FL10723
Page 2 of 20
Stiffness Class I
Impact 350 ft-lbs
Door
Type Configuration Max.
Size
Min.
Gauge
*Max.
Design
Load
(psf)
Min. Latch Throw
(in)
Lock Side -
Min. Latch
Strength (lbf)
Hardware Type
**Trio
Trio-E
Inswing/
Outswing
30x70
Single 18 ±100
½” cylindrical
¾”mortise lock
1050
Cylindrical Lock,
Mortise Lock w/
Deadbolt function
**Trio
Trio-E Outswing 30x70
Single 18 ±100 ¾” rim exit 1050
Rim Exit
**Trio
Trio-E
Inswing/
Outswing
60x70
Pair 18 ±70
½” cylindrical
1” deadlock
¾”mortise lock
735
Cylindrical x
Deadlock, Mortise
Lock w/
Deadbolt function
(active), Flush Bolt
or Surface Bolt(In-
Active)
**Trio
Trio-E
Inswing/
Outswing
40x80
Single 18 ±70
½” cylindrical
¾”mortise lock
1120
Cylindrical Lock,
Mortise Lock w/
Deadbolt function
**Trio
Trio-E Outswing 40x80
Single 18 ±70 ¾” rim exit 1120 Rim Exit
**Trio
Trio-E Outswing 80x80
Pair 18 ±70
¾” rim exit x ¾” rim exit
¾” Vertical Rod Exit x
¾” Vertical Rod Exit
1120
Rim Exit
x Hardware Mullion
Vertical Rod Exit x
Vertical Rod Exit
**Trio
Trio-E
Inswing/
Outswing
80x80
Pair 18 ±70
½” cylindrical
1” deadlock
¾”mortise lock
1120
Cylindrical Lock x
Deadlock,
Mortise Lock w/
Deadbolt function,
(Active)
Flush Bolt or
Surface Bolt(In-
Active)
*Glass lights may limit design loads. See details to follow for additional information.
**Louvers are excluded from use with Trio and Trio-E Doors.
Windstorm Door Installation Instructions
For Use With FL10723
Page 3 of 20
Stiffness Class II Impact 350 ft-lbs
Door
Type Configuration Max.
Size
Min.
Gauge
*Max.
Design
Load (psf)
Min. Latch Throw (in)
Lock Side -
Min. Latch
Strength (lbf)
Hardware Type
Imperial
Versadoor
Mercury
Inswing/
Outswing
30 x 70
Single 18 +/- 70
½” cylindrical, 1” deadlock
¾” mortise, 1” deadbolt
½” act latch, 1” deadbolt
(ICL)
735
Cylindrical Lock x
Deadlock, Mortise
Lock w/deadbolt,
Interconnected
lock
Imperial
Versadoor
Mercury
Outswing 30 x 70
Single 18 +/- 60
½” cylindrical
¾” mortise
n/a mortise/rim/vertical
rod exit
630
Cylindrical Lock,
Mortise Lock
(Deadbolt not
required), Mortise
Exit, Rim Exit,
Vertical Rod Exit
*Glass lights may limit design loads. See details to follow for additional information.
**Louvers are excluded from use with Trio and Trio-E Doors.
Windstorm Door Installation Instructions
For Use With FL10723
Page 4 of 20
Medallion Steel-Stiffened Core Door Details
Windstorm Door Installation Instructions
For Use With FL10723
Page 5 of 20
Trio Steel-Stiffened Core Door Details
Windstorm Door Installation Instructions
For Use With FL10723
Page 6 of 20
Trio-E Steel-Stiffened Core Door Details
Windstorm Door Installation Instructions
For Use With FL10723
Page 7 of 20
Glazed Trio/Trio-E Core Door Details
Windstorm Door Installation Instructions
For Use With FL10723
Page 8 of 20
Polystyrene Core Door Details
³
Windstorm Door Installation Instructions
For Use With FL10723
Page 9 of 20
Honeycomb Core Door Details
Windstorm Door Installation Instructions
For Use With FL10723
Page 10 of 20
Polyurethane Core Door Details
Windstorm Door Installation Instructions
For Use With FL10723
Page 11 of 20
Mineral Core Door Details
Windstorm Door Installation Instructions
For Use With FL10723
Page 12 of 20
Mercury Core Details
REF.0.590
18 GA. END CAP
NOTCHED FOR
SPINDLES
16 GA END CHANNEL
REF.0.590
LENGTH VARIES DEPENDING ON DOOR
DO366
HEIGHT AND CLOSER REINFORCEMENT.
"EMBOSSED SKINS OPTIONAL"
6 " (T Y P )REF.
6 " (T Y P )0.040
MIN.
6 " (T Y P )MIN."V a rie s " d e p e n d s
o n D o o r W id th
6 " (T Y P )REF.
6" (TYP)
0.042.640 DIAMOND
RELIEF SLOT FOR SPINDLE
1.469
0.681
VARIES
DEPENDS ON DOOR WIDTH.
APPLY 1
8" BEAD EPOXY
TO BOTTOM SPINDLE
CHANNEL PLACE IN SKIN.
TYPICAL TAB & SLOT CONSTRUCTION
.590" SQ TUBE x .040" THICKNESS
18 GA BOTTOM SKIN
POLYURETHANE FOAM
18 GA TOP SKIN
FIT SPINDLE INTO
DIAMOND SHAPE CUTOUT.
POSITION IN DOOR PER
DETAIL.
Windstorm Door Installation Instructions
For Use With FL10723
Page 13 of 20
End Channel Spot Weld Details
Windstorm Door Installation Instructions
For Use With FL10723
Page 14 of 20
TYPE 2 VISION LIGHT KIT
*SEE LIMITATIONS BELOW
VISION LIGHT KIT DETAILS
TYPE 1 VISION LIGHT KIT
**SEE LIMITATIONS BELOW
Applied Glass Kit Details
Windstorm Door Installation Instructions
For Use With FL10723
Page 15 of 20
TYPE 2 VISION LIGHT KIT
*SEE LIMITATIONS BELOW
VISION LIGHT KIT DETAILS
Applied Glass Kit Details Trio/Trio-E
Windstorm Door Installation Instructions
For Use With FL10723
Page 16 of 20
Flush Welded Glass Kit Details
Polycarbonate Glazing Instructions
Windstorm Door Installation Instructions
For Use With FL10723
Page 17 of 20
Polycarbonate Glazing Instructions
Windstorm Door Installation Instructions
For Use With FL10723
Page 18 of 20
Alternate Flush Welded Glass Kit Details
Windstorm Door Installation Instructions
For Use With FL10723
Page 19 of 20
Glasslam Safety Plus II Glazing Instructions
Windstorm Door Installation Instructions
For Use With FL10723
Page 20 of 20
Louver Details
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 1 of 14
THREE-SIDED FRAMES
@ ead (4) Total Req'd,
Total Req'd,
@ ead (4) Total Req'd,
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 2 of 14
TWO-PIECE THREE-SIDED FRAME
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 3 of 14
THREE SIDED FRAMES
2" MIN
3-3/8" MAX
2-5/8" MIN
4" MAX
VARIES
VARIES
2" MIN
4" MAX
2.125"
Door Rabbet
VARIES
1.9375"
Door Rabbet
VARIES
2" MIN
4" MAX
1.9375"
Door Rabbet
2-5/8" MIN
4" MAX2" MIN
3-3/8" MAX
2.125"
Door Rabbet
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 4 of 14
SIDE LITE AND TRANSOM FRAMES
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 5 of 14
BORROWED LITE FRAMES
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 6 of 14
HURRICANE RESISTANT FRAMES-GLASSLAM SAFETY PLUS II GLAZING INSTRUCTIONS
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 7 of 14
SEE NOTE 1
FRAME FACE
CONTINUOUSLY WELDED
3/4" LEG OF "C" CHANNELS
FULLY WELDED TO FRAME
10
70" MIN
118" MAX
0.75"
PROFILE WIDTH
- 1/4"
"C" CHANNEL10
CONTINUOUSLY WELDED ON
BOTH ENDS AT SEAMS
SEE NOTE 2
10
10
"I" BEAM CONSTRUCTION DETAILS
NOTE:
1. MULLIONS MUST RUN THROUGH HEADS, SILLS, OR JAMBS AND BE
REINFORCED WITH 10 GAUGE "C" CHANNELS (ITEM 10) IF EQUAL TO OR GREATER THAN
6' IN LENGTH.
2. 10 GA. "C" CHANNELS MUST BE INSTALLED BEFORE WELDING TOGETHER. OFFSET 3/4"
ON EACH END.
3. EQUALLY SPACED AT EACH END OF MULLION.
F0292
FRAME CONSTRUCTION AND MULLION DETAIL
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 8 of 14
ALTERNATE FRAME DESIGN
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 9 of 14
KD FRAME CORNERS
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 10 of 14
STUD WALL FRAME ANCHORS
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 11 of 14
MASONRY WALL FRAME ANCHORS
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 12 of 14
HURRICANE RESISTANT FRAMES – SHIM PLATE DETAIL
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 13 of 14
WATER INFILTRATION PREPARATIONS SINGLE SWING
Windstorm Frame Installation Instructions
For Use With FL 10723
Page 14 of 14
WATER INFILTRATION PREPARATIONS STANDARD SWING PAIR
WEATHER STRIP FOR WATER INFILTRATION
PAIRS OF DOORS PER TAS 202 DESIGN PRESSURE 60 PSF