HomeMy WebLinkAbout05-Versico TPO (FL14207-R20) (Exp 12.21) NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Versico Roofing Systems P.O. Box 1289 Carlisle, PA 17013 (717) 245-7264 Evaluation Report C35230.11.10-R20 FL14207-R20 Date of Issuance: 11/02/2010 Revision 20: 02/19/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: VersiWeld TPO Single Ply Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO|etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words “NEMO|etc. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus a 65-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 02/19/2019. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO|etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NEMO|etc. NEMO ETC, LLC Evaluation Report C35230.11.10-R20 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14207-R20 VersiWeld TPO Single Ply Roof Systems Revision 20: 02/19/2019 Page 2 of 5 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Single Ply Roof Systems Compliance Statement: VersiWeld TPO Single Ply Roof Systems, as produced by Versico Roofing Systems, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.3.1 Wind UL 1897 2012 1504.7 Impact FM 4470 2012 1507.13.2 Physical Properties ASTM D6878 2011 TAS 110 Physical Properties TAS 131 1995 3. REFERENCES: Entity Exam Reference Date Entity Exam Reference Date ACRC (TST4671) Wind 07-051 08/29/2007 FM App (TST1867) FM 4474 3024593 07/27/2006 ACRC (TST4671) Wind 07-059 10/15/2007 FM App (TST1867) FM 4474 3022174 09/25/2006 ACRC (TST4671) Wind 10-009 05/19/2010 FM App (TST1867) FM 4474 3021235 06/01/2007 ACRC (TST4671) Wind 10-018 08/25/2010 FM App (TST1867) FM 4474 3026964 07/25/2007 ACRC(TST4671) Wind 10-019 08/25/2010 FM App (TST1867) FM 4474 3028438 08/22/2007 ACRC(TST4671) Wind 11-034 06/28/2011 FM App (TST1867) FM 4474 3031350 09/27/2007 ACRC(TST4671) Wind 11-035 06/28/2011 FM App (TST1867) FM 4474 3030536 10/09/2007 ACRC(TST4671) Wind 11-036 06/29/2011 FM App (TST1867) FM 4474 3028655 11/09/2007 ACRC(TST4671) Wind 11-037 06/29/2011 FM App (TST1867) FM 4474 3026951 01/21/2008 ACRC(TST4671) Wind 15-002 03/30/2015 FM App (TST1867) FM 4474 3031349 05/13/2008 ACRC(TST4671) Wind 15-008 04/02/2015 FM App (TST1867) FM 4474 3031765 07/21/2008 ACRC(TST4671) Wind 15-009 04/06/2015 FM App (TST1867) FM 4474 3029840 09/08/2008 ACRC(TST4671) Wind 15-011 07/07/2015 FM App (TST1867) FM 4474 3033217 12/08/2008 ACRC(TST4671) Wind 15-012 07/07/2015 FM App (TST1867) FM 4474 3034985 12/15/2008 ACRC(TST4671) Wind 15-015 07/09/2015 FM App (TST1867) FM 4474 3034066 04/14/2009 ACRC(TST4671) Wind 15-016 07/09/2015 FM App (TST1867) FM 4474 3034776 08/07/2009 ACRC(TST4671) Wind 15-018 07/10/2015 FM App (TST1867) FM 4474 3037400 09/02/2009 ACRC(TST4671) Wind 15-019 07/14/2015 FM App (TST1867) FM 4474 3033356 10/09/2009 ACRC(TST4671) Wind 15-020 07/14/2015 FM App (TST1867) FM 4474 3034297 11/13/2009 ACRC(TST4671) Wind 15-021 07/15/2015 FM App (TST1867) FM 4474 3040639 08/11/2010 ACRC(TST4671) Wind 15-037 12/28/2015 FM App (TST1867) FM 4474 3036762 03/08/2011 ACRC(TST4671) Wind 15-038 12/28/2015 FM App (TST1867) FM 4474 3041535 06/08/2011 ACRC(TST4671) Wind 15-041 12/30/2015 FM App (TST1867) FM 4474 3039340 06/24/2011 ACRC(TST4671) Wind 15-043 01/04/2016 FM App (TST1867) FM 4474 3043858 08/25/2011 ACRC(TST4671) Wind 15-045 01/11/2016 FM App (TST1867) FM 4474 3041797 10/13/2011 ACRC(TST4671) Wind 15-046 01/11/2016 FM App (TST1867) FM 4474 3039073 11/22/2011 ACRC(TST4671) Wind 15-047 01/12/2016 FM App (TST1867) FM 4470 1X9A4.AM 12/06/2011 ATI (TST1588) FM 4470 01-37050.01 03/13/2000 FM App (TST1867) FM 4470 3000919 12/06/2011 ATI (TST1588) FM 4470 01-39152.01 03/28/2001 FM App (TST1867) FM 4470 3041535 12/06/2011 ATI (TST1588) Physicals 01-37490.01 05/26/2004 FM App (TST1867) FM 4470 3044748 12/06/2011 ATI (TST1588) FM 4470 63524.01-111-47 03/16/2006 FM App (TST1867) FM 4474 3040260 02/27/2012 ATI (TST1588) FM 4470 76506.01-111-47 09/06/2007 FM App (TST1867) FM 4474 3041799 03/29/2012 ATI (TST1588) FM 4470 77891.01-111-47 10/26/2007 FM App (TST1867) FM 4474 3043824 04/06/2012 ATI (TST1588) FM 4474 C1141.01-109-18 09/13/2012 FM App (TST1867) FM 4474 3039762 09/07/2012 ATI (TST1588) TAS 114 D7772.01-109-18 07/09/2014 FM App (TST1867) FM 4474 3047327 09/13/2012 ATI (TST1588) TAS 114 D7772.02-109-18 07/14/2014 FM App (TST1867) FM 4474 3040639 09/18/2012 ATI (TST1588) TAS 114 E4981.01-109-18 02/26/2015 FM App (TST1867) FM 4474 3043858 09/25/2012 CTL (TST1577) FM 4474 CTLA-105R 10/13/2008 FM App (TST1867) FM 4474 3042075 10/23/2012 CTL (TST1577) FM 4474 CTLA-105R-1 10/13/2008 FM App (TST1867) FM 4474 3045953 02/13/2013 CTL (TST1577) FM 4474 CTLA-105R-2 10/13/2008 FM App (TST1867) FM 4451 3049232 09/11/2013 CTL (TST1577) FM 4474 CTLA-106R 10/16/2008 FM App (TST1867) FM 4474 3049189 03/11/2014 CTL (TST1577) FM 4474 CTLA-106R-1 10/16/2008 FM App (TST1867) FM 4474 3048753 09/16/2014 CTL (TST1577) FM 4474 CTLA-106R-2 10/16/2008 FM App (TST1867) FM 4474 3051392 (data) 10/15/2014 CTL (TST1577) FM 4474 CTLA-106R-3 10/16/2008 FM App (TST1867) FM 4474 3054838 02/13/2015 CTL (TST1577) FM 4474 CTLA-106R-4 10/16/2008 FM App (TST1867) FM 4474 3055462 04/01/2015 NEMO|etc. NEMO ETC, LLC Evaluation Report C35230.11.10-R20 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14207-R20 VersiWeld TPO Single Ply Roof Systems Revision 20: 02/19/2019 Page 3 of 5 Entity Exam Reference Date Entity Exam Reference Date CTL (TST1577) TAS 117 CTLA 111R 01/13/2009 FM App (TST1867) FM 4451 3054498 11/30/2015 ERD (TST 6049) Physicals U0215.05.06-1 05/30/2006 FM App (TST1867) FM 4474 3050229 01/25/2016 ERD (TST 6049) FM 4470 E9490.03.08 03/25/2008 FM App (TST1867) FM 4474 3058125 02/04/2016 ERD (TST 6049) Physicals C32760.01.11 01/19/2011 FM App (TST1867) FM 4474 3055167 02/10/2016 ERD (TST 6049) Physicals A35880.04.12-R1 10/26/2012 FM App (TST1867) FM 4474 3055824 05/31/2016 ERD (TST 6049) Physicals C46470.07.14-1A 07/16/2014 FM App (TST1867) FM 4474 RR206411 09/26/2018 ERD (TST 6049) Physicals C46470.07.14-1B 07/16/2014 FM App (TST1867) FM 4474 3056745 09/28/2016 ERD (TST 6049) Physicals C46470.07.14-4-R1 07/21/2014 FM App (TST1867) FM 4474 3058125 12/06/2016 ERD (TST 6049) Physicals C46470.07.14-2A 07/30/2014 FM App (TST1867) FM 4474 3062422 (data) 05/25/2017 ERD (TST 6049) Physicals C46470.07.14-2B 07/30/2014 FM App (TST1867) FM 4470 3063373 (data) 10/10/2017 ERD (TST 6049) FM 4474 SC10010.02.16 02/29/2016 FM App (TST1867) FM 4474 3063373 (data) 11/07/2017 ERD (TST 11294) FM 4474 13380.01.17 01/27/2017 FM App (TST1867) FM 4474 3062422 (data) 01/05/2018 ERD (TST 6049) FM 4474 CRL-SC13450.01.17 01/31/2017 FM App (TST1867) FM 4474 PR449852 (data) 03/29/2018 ERD (TST 6049) Physicals CRL-SC14240.17 03/21/2017 FM App (TST1867) FM 4474 3058463 05/22/2018 ERD (TST 11294) FM 4474 CLT16160.08.17-1 08/28/2017 FM App (TST1867) FM 4474 PR451012 (data) 10/11/2018 ERD (TST 11294) FM 4474 CLT16160.08.17-2 08/28/2017 FM App (TST1867) FM 4474 PR452297 (data) 12/05/2018 FM App (TST1867) FM 4470 3Z9A1.AM 10/15/1997 FM App (TST1867) FM 4474 PR452297 (data) 12/06/2018 FM App (TST1867) FM 4470 3001580 11/16/1998 FM App (TST1867) FM 4474 PR452773 (data) 01/30/2019 FM App (TST1867) FM 4470 3001522 03/26/1999 FM App (TST1867) FM 4474 PR452773 (data) 02/01/2019 FM App (TST1867) FM 4470 3003393 03/30/1999 M-D (CER1592) Wind Uplift 12-0216.01 03/08/2012 FM App (TST1867) FM 4470 3003337 06/11/1999 M-D (CER1592) Wind Uplift 13-0617.20 09/05/2013 FM App (TST1867) FM 4470 3006110 06/13/2001 M-D (CER1592) Wind Uplift 13-0307.02 09/26/2013 FM App (TST1867) FM 4470 3011329 06/10/2002 NEMO (TST 6049) Physicals 4-CRL-18-002.04.18-1 04/03/2018 FM App (TST1867) FM 4470 3012879 04/04/2003 NEMO (TST 6049) Physicals 4-CRL-18-002.04.18-2 04/03/2018 FM App (TST1867) FM 4470 3013584 06/27/2003 NEMO (TST 6049) Physicals 4-CRL-18-002.04.18-2A 04/03/2018 FM App (TST1867) FM 4470 3014692 08/05/2003 NEMO (TST 6049) FM 4474 4-CRL-18-003.05.18 05/15/2018 FM App (TST1867) FM 4470 3016355 09/15/2003 NEMO (TST 6049) FM 4474 CRL-SC16815.06.18 06/07/2018 FM App (TST1867) FM 4470 3019890 12/16/2004 NEMO (TST 6049) Criticality 4S-CRL-18-005.11.18 11/06/2018 FM App (TST1867) FM 4474 3017662 06/07/2005 NEMO (TST 6049) FM 4474 4L-CRL-18-003.12.18 12/01/2018 FM App (TST1867) FM 4474 3023032 07/20/2005 NEMO (TST 6049) FM 4474 4L-CEL-18-001.12.18 12/14/2018 FM App (TST1867) FM 4474 3018631 11/03/2005 NEMO (TST 11294) FM 4474 2-CRL-18-002.04.18 05/15/2018 FM App (TST1867) FM 4474 3023999 11/08/2005 PRI CMT(TST5878) FM 4474 CST-016-02-01 05/04/2011 FM App (TST1867) FM 4474 3020845 01/25/2006 PRI CMT(TST5878) FM 4474 CST-016-02-01 05/05/2011 FM App (TST1867) FM 4474 3021941 03/20/2006 UL, LLC. (TST9628) UL 1897 08CA15815 10/22/2008 FM App (TST1867) FM 4474 3023340 03/20/2006 UL, LLC. (QUA9625) QC Service Confirmation 12/14/2018 FM App (TST1867) FM 4474 3023458 07/18/2006 4. PRODUCT DESCRIPTION: The following roof covers are mechanically attached or adhered to Approved substrates using fasteners, stress plates and adhesives, as outlined in the Limitations / Conditions of Use herein. 4.1 VersiWeld Reinforced TPO Membrane are nominal 45-mil (1.1-mm) or 60-mil (1.5-mm) thick, polyester-scrim reinforced, thermoplastic olefin (TPO) single-ply roof membranes; meets ASTM D6878-11 & TAS 131. 4.2 VersiWeld Plus Reinforced TPO Membrane are nominal 72-mil (1.8-mm) or 80-mil (2.0-mm) thick, polyester-scrim reinforced, thermoplastic olefin (TPO), single-ply roof membranes; meets ASTM D6878-11 & TAS 131. 4.3 VersiWeld HS/ES Reinforced TPO Membrane are nominal 60-mil (1.5-mm) thick, polyester-scrim reinforced, thermoplastic olefin (TPO) single-ply roof membranes; meets TAS 131. 4.4 VersiFleece FR TPO membrane is a variation of VersiWeld Reinforced TPO Membrane 60-mil (1.5 mm), but with a carbon-fiber fleece on the back side for fire-rating considerations over wood deck; meets ASTM D6878-11 & TAS 131. 4.5 VersiFleece TPO 100, TPO 115 or TPO 135 membranes are nominal 45-mil (1.1-mm), 60-mil (1.5-mm) or 80-mil (2.0- mm) thick, respectively, polyester-scrim reinforced, thermoplastic olefin (TPO) single-ply roof membranes with a polyester fleece backing; meets ASTM D6878-11 & TAS 131. 4.6 VersiFleece AC TPO 120, AC TPO 135 or AC TPO 155 membranes are nominal 45-mil (1.1-mm), 60-mil (1.5-mm) or 80-mil (2.0-mm) thick, respectively, polyester-scrim reinforced, thermoplastic olefin (TPO) single-ply roof membranes with a polyester fleece backing formulated for hot asphalt application; meets ASTM D6878-11 & TAS 131. 4.7 VersiWeld QA TPO membrane is a nominal 60-mil (1.5-mm) thick, polyester-scrim reinforced, thermoplastic olefin (TPO) single-ply roof membrane laminated to an elastomeric pressure-sensitive adhesive; meets TAS 131. NEMO|etc. NEMO ETC, LLC Evaluation Report C35230.11.10-R20 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14207-R20 VersiWeld TPO Single Ply Roof Systems Revision 20: 02/19/2019 Page 4 of 5 4.8 VersiFleece RL™ with RapidLock Technology membranes are a variation of VersiWeld membranes, but with VELCRO® Brand Securable Solutions fleece on the back side for use with VersiCore RL or SecurShield HD RL substrates; meets ASTM D6878-11 & TAS 131. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO|etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current UL Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. NEMO|etc. NEMO ETC, LLC Evaluation Report C35230.11.10-R20 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL14207-R20 VersiWeld TPO Single Ply Roof Systems Revision 20: 02/19/2019 Page 5 of 5 6. INSTALLATION: 6.1 VersiWeld TPO Single Ply Roof Systems shall be installed in accordance with Versico Roofing Systems published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 6.2 For mechanically fastened membrane systems (Type D) over profiled steel deck, membrane shall be installed running perpendicular to steel deck flutes. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered by QA procedures in accordance with FAC Rule 61G20-3. 9. QUALITY ASSURANCE ENTITY: UL, LLC – QUA9625; (414) 248-6409; karen.buchmann@ul.com - THE 65-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO|etc. NEMO ETC, LLC Evaluation Report C35230.11.10-R20 for FL14207-R20 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 02/19/2019 Prepared by: Robert Nieminen, PE-59166 VersiWeld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 32 of 64 TABLE 2H: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-1: INSULATED, MECHANICALLY ATTACHED ROOF COVER System No. Deck (Note 1) Insulation Layer (Note 14) Roof Cover MDP (psf) Type Attach (Note 5) Membrane Fasteners Fastener Spacing Lap Width Lap Spacing Seam Weld SC-210 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete Min. 1.5-inch, one or more layers, any combination Prelim. attach VersiWeld or VersiWeld Plus HPV-X Fastener (steel only), MP 14-10 (concrete only) or CD- 10 (concrete only) Fasteners and HPV-X Plate or #15 Roofgrip (steel only) with 2-3/8” Eyehook Seam Plates (AccuSeam) 9-inch o.c. 5.5- inch 54.5-inch o.c. 1.5-inch outside -75.0 SC-211 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structural concrete Min. 1.5-inch, one or more layers, any combination Prelim. attach VersiWeld or VersiWeld Plus HPV-X Fastener (steel only), MP 14-10 (concrete only) or CD- 10 (concrete only) Fasteners and HPV-X Plate or #15 Roofgrip (steel only) with 2-3/8” Eyehook Seam Plates (AccuSeam) 6-inch o.c. 5.5- inch 42.5-inch o.c. 1.5-inch outside -82.5 SC-212 Min. 22 ga., type B, Grade 33 steel Min. 1.5-inch, one or more layers, any combination Prelim. attach VersiWeld or VersiWeld Plus Trufast #15 EHD Fastener with Trufast 2.4” Barbed Metal Seam Plates 12-inch o.c. 5.5- inch 42.5-inch o.c. 1.5-inch outside -82.5 SC-213 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete Min. 1.5-inch, one or more layers, any combination Prelim. attach VersiWeld or VersiWeld Plus HPV-X Fastener (steel only), MP 14-10 (concrete only) or CD- 10 (concrete only) Fasteners and HPV-X Plate or #15 Roofgrip (steel only) with 2-3/8” Eyehook Seam Plates (AccuSeam) 6-inch o.c. 5.5- inch 54.5-inch o.c. 1.5-inch outside -90.0 SC-214 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete Min. 1.5-inch, one or more layers, any combination Prelim. attach VersiWeld or VersiWeld Plus Trufast #15 EHD Fastener with Trufast 2.4” Barbed Metal Seam Plates 6-inch o.c. 5.5- inch 42.5-inch o.c. 1.5-inch outside -112.5 VERSIFLEECE APPLICATIONS: SC-215 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete Min. 1.5-inch, one or more layers, any combination Prelim. attach VersiFleece HPV-X Fasteners (steel only), MP 14-10 (concrete only) or CD- 10 (concrete only) Fasteners and HPV-X Plates or #15 Roofgrip (steel only) with 2-3/8” Eyehook Seam Plates (AccuSeam) 12-inch o.c. 5.5- inch 138.5-inch o.c. 1.5-inch outside -30.0 SC-216 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete Min. 1.5-inch, one or more layers, any combination Prelim. attach VersiFleece HPV-XL Fasteners and HPV-XL Plates (steel only) or MP 14-10 (concrete only) or CD-10 (concrete only) Fasteners and HPV-X Plates or #15 Roofgrip (steel only) with 2-3/8” Eyehook Seam Plates (AccuSeam) 12-inch o.c. 5.5- inch 114.5-inch o.c. 1.5-inch outside -37.5 SC-217 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete Min. 1.5-inch, one or more layers, any combination Prelim. attach VersiFleece HPV-X Fasteners (steel only), MP 14-10 (concrete only) or CD- 10 (concrete only) Fasteners and HPV-X Plates or #15 Roofgrip (steel only) with 2-3/8” Eyehook Seam Plates (AccuSeam) 6-inch o.c. 5.5- inch 138.5-inch o.c. 1.5-inch outside -37.5 SC-218 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structural concrete Min. 1.5-inch, one or more layers, any combination Prelim. attach VersiFleece HPV-X Fasteners (steel only), MP 14-10 (concrete only) or CD- 10 (concrete only) Fasteners and HPV-X Plates or #15 Roofgrip (steel only) with 2-3/8” Eyehook Seam Plates (AccuSeam) 6-inch o.c. 5.5- inch 90.5-inch o.c. 1.5-inch outside -60.0