HomeMy WebLinkAboutCALLAHAN RES,-REVISED-ENERGY CALCEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 64/16/2020 9:45 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST. LUCIE COUNTY MATHEW CALLAHAN MATHEW CALLAHAN CALLAHAN RESIDENCE Street: City, State, Zip: PORT ST. LUCIE , FL , 504 E. MIDWAY RD. Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 2119 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.31 119.00 ft² SHGC=0.17 Sgl, U=0.31 81.00 ft² SHGC=0.19 N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2119.00 ft² R=f t ² R=f t ² 9. Wall Types a. Frame - Wood, Exterior R=19.0 1533.00 ft² b. Frame - Wood, Adjacent R=11.0 576.00 ft² c. Frame - Wood, Adjacent R=19.0 168.00 ft² 10. Ceiling Types a. Roof Deck (Unvented)R=20.0 2119.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: LAUNDRY 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:5.400 ft. Area Weighted Average SHGC:0.178 Description Area Insulation Area Insulation Area Insulation Area 15. Credits Pstat 3 (200.0 sqft.) (2277.0 sqft.) (2119.0 sqft.) (2119.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 33.4 SEER:21.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 225 EF: 0.950 Glass/Floor Area: 0.094 Total Proposed Modified Loads: Total Baseline Loads: 50.40 61.80 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 4-16-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST. LUCIE COUNTY MATHEW CALLAHAN 1 MATHEW CALLAHAN CALLAHAN RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 2119 3 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , PORT ST. LUCIE , St. Lucie 504 E. MIDWAY RD. Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2119 20703 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 BEDROOM 3 210 1890 No 1 1 Yes Yes1 Yes 2 BATH 3 50 450 No 0 Yes Yes1 Yes 3 BATH 2 55 495 No 0 Yes Yes1 Yes 4 BEDROOM 2 225 2025 No 1 1 Yes Yes1 Yes 5 HALL 40 360 No 0 Yes Yes1 No 6 GREAT ROOM 430 3870 No 4 Yes Yes1 Yes 7 DINING 168 1512 No 0 Yes Yes1 Yes 8 KITCHEN 182 1638 No 2 Yes Yes1 Yes 9 LAUNDRY 150 1350 No 0 Yes Yes1 Yes 10 1/2 BATH 25 225 No 0 Yes Yes1 No 11 WIC. 128 1536 No 0 Yes Yes1 No 12 TOILET 36 432 No 0 Yes Yes1 No 13 MASTER BEDROO 236 2832 No 0 1 Yes Yes1 Yes 14 WIC 36 432 No 0 Yes Yes1 Yes 15 MASTER BATH 108 1296 No 0 Yes Yes1 Yes 16 POWDER 40 360 No 0 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 210 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -029 ft BEDROOM 3 2 55 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 3 4/16/2020 9:45 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 3 50 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 2 4 225 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -035 ft BEDROOM 2 5 40 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 6 430 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -019 ft GREAT ROOM 7 168 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -012 ft DINING 8 182 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -013 ft KITCHEN 9 150 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -010 ft LAUNDRY 10 25 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -01 ft 1/2 BATH 11 128 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -01 ft WIC. 12 36 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -01 ft TOILET 13 236 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -016 ft MASTER BEDRO 14 36 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -06 ft WIC 15 108 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -06 ft MASTER BATH 16 40 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -05 ft POWDER # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 2233 ft² Light 0.6 20 18.4______ No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 2119 ft² N N0 4/16/2020 9:45 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented) 0 210 ft² 0.1 Wood______ BEDROOM 3 Blown 2 Under Attic (Unvented) 0 50 ft² 0.1 Wood______ BATH 3 Blown 3 Under Attic (Unvented) 0 55 ft² 0.1 Wood______ BATH 2 Blown 4 Under Attic (Unvented) 0 225 ft² 0.1 Wood______ BEDROOM 2 Blown 5 Under Attic (Unvented) 0 40 ft² 0.1 Wood______ HALL Blown 6 Under Attic (Unvented) 0 430 ft² 0.1 Wood______ GREAT ROOM Blown 7 Under Attic (Unvented) 0 168 ft² 0.1 Wood______ DINING Blown 8 Under Attic (Unvented) 0 182 ft² 0.1 Wood______ KITCHEN Blown 9 Under Attic (Unvented) 0 150 ft² 0.1 Wood______ LAUNDRY Blown 10 Under Attic (Unvented) 0 25 ft² 0.1 Wood______ 1/2 BATH Blown 11 Under Attic (Unvented) 0 128 ft² 0.1 Wood______ WIC. Blown 12 Under Attic (Unvented) 0 36 ft² 0.1 Wood______ TOILET Blown 13 Under Attic (Unvented) 0 236 ft² 0.1 Wood______ MASTER BEDRO Blown 14 Under Attic (Unvented) 0 36 ft² 0.1 Wood______ WIC Blown 15 Under Attic (Unvented) 0 108 ft² 0.1 Wood______ MASTER BATH Blown 16 Under Attic (Unvented) 0 40 ft² 0.1 Wood______ POWDER Blown WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 19 0BEDROOM 3 00014 9S Frame - Wood 0.50.25Exterior 126.0 ft² ____ 2 19 0BEDROOM 3 00015 9W Frame - Wood 0.50.25Exterior 135.0 ft² ____ 3 19 0BATH 3 0005 9S Frame - Wood 0.50.25Exterior 45.0 ft² ____ 4 19 0BATH 2 0005 9S Frame - Wood 0.50.25Exterior 45.0 ft² ____ 5 19 0BEDROOM 2 0005 9N Frame - Wood 0.50.25Exterior 45.0 ft² ____ 6 19 0BEDROOM 2 00015 9E Frame - Wood 0.50.25Exterior 135.0 ft² ____ 7 19 0BEDROOM 2 00015 9S Frame - Wood 0.50.25Exterior 135.0 ft² ____ 8 19 0GREAT ROO 00019 9E Frame - Wood 0.50.25Exterior 171.0 ft² ____ 9 19 0DINING 00012 9W Frame - Wood 0.50.25Exterior 108.0 ft² ____ 10 19 0KITCHEN 00013 9W Frame - Wood 0.50.25Exterior 117.0 ft² ____ 11 19 0LAUNDRY 00010 9E Frame - Wood 0.50.25Exterior 90.0 ft² ____ 12 19 0MASTER BE 00016 12W Frame - Wood 0.50.25Exterior 192.0 ft² ____ 13 19 0WIC 0006 12W Frame - Wood 0.50.25Exterior 72.0 ft² ____ 14 19 0MASTER BA 0006 12W Frame - Wood 0.50.25Exterior 72.0 ft² ____ 15 19 0POWDER 0005 9W Frame - Wood 0.50.25Exterior 45.0 ft² ____ 16 19 0WIC. 014 12N Frame - Wood 0.6000000.25Garage 168.0 ft² ____ 17 11 0POWDER 048 12N Frame - Wood 0.6000000.25Garage 576.0 ft² ____ 4/16/2020 9:45 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 W Low-E Single 0.31 0.17 15.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes2 Y 2 S Low-E Single 0.31 0.17 6.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes3 Y 3 S Low-E Single 0.31 0.17 6.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes4 Y 4 E Low-E Single 0.31 0.17 15.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes6 Y 5 E Low-E Single 0.31 0.19 40.0 ft² 5 ft 0 in 1 ft 4 in NoneVinyl None______ Yes8 Y 6 E Low-E Single 0.31 0.17 20.0 ft² 5 ft 0 in 1 ft 4 in NoneVinyl None______ Yes8 Y 7 W Low-E Single 0.31 0.19 41.0 ft² 12 ft 0 in 1 ft 4 in NoneVinyl None______ Yes9 Y 8 W Low-E Single 0.31 0.17 9.0 ft² 12 ft 0 in 1 ft 4 in NoneVinyl None______ Yes10 Y 9 E Low-E Single 0.31 0.17 9.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes11 Y 10 W Low-E Single 0.31 0.17 30.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes12 Y 11 W Low-E Single 0.31 0.17 9.0 ft² 2 ft 0 in 1 ft 4 in NoneVinyl None______ Yes14 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 1200 ft² 1200 ft² 64 ft 8 ft 1______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 2415.4 7132.6.000435Wholehouse .1631249.37Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/ COP:1 27 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/ SEER: 21 33.4 kBtu/hr 1002 cfm 0.7______ sys#1Split 1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.95 50 gal 60.9 gal 120 deg None______ None Garage FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume None None f t ² ______ 4/16/2020 9:45 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 225 ft² Attic 65 ft² Prop. Leak Free LAUNDRY 63.6 cfm 0.03 0.50______ 1 1 --- cfm TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. f t ² f t 0.3 BATH 3 Default(8 lbs/sq.ft. f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft. f t ² f t 0.3 HALL Default(8 lbs/sq.ft. f t ² f t 0.3 GREAT ROOM Default(8 lbs/sq.ft. f t ² f t 0.3 DINING Default(8 lbs/sq.ft. f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft. f t ² f t 0.3 LAUNDRY Default(8 lbs/sq.ft. f t ² f t 0.3 1/2 BATH Default(8 lbs/sq.ft. f t ² f t 0.3 WIC. Default(8 lbs/sq.ft. f t ² f t 0.3 TOILET Default(8 lbs/sq.ft. f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft. f t ² f t 0.3 WIC Default(8 lbs/sq.ft. f t ² f t 0.3 MASTER BATH Default(8 lbs/sq.ft. f t ² f t 0.3 POWDER 4/16/2020 9:45 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT