Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
callahan res.-manual j
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-16 10:49:41 Right-Suite® Universal 2019 19.0.07 RSU08101 Page 1 ...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Project Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information CALLAHAN RESIDENCEFor:504 E. MIDWAY RD., PORT ST. LUCIE, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh16662 Structure Btuh19929 Ducts Btuh3717 Ducts Btuh2819Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh20379 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh21611 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh5311 Ducts Btuh2217Central vent (0 cfm) Btuh0 CoolingHeating (none)21242124Area (ft²) Equipment latent load Btuh7529 2074820748Volume (ft³)Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh29139 Equiv. AVF (cfm) 55111 Req. total capacity at 0.70 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make Make AmanaTrade Trade GOODMAN Model Cond AVXC200361AAHRI ref Coil AVPEC59D14A AHRI ref 9993615Efficiency 100 AFUE Efficiency 13.0 EER, 21 SEER Heating input kW3.6 Sensible cooling Btuh23380Heating output Btuh12144 Latent cooling Btuh10020 Temperature rise °F50 Total cooling Btuh33400Actual air flow cfm221 Actual air flow cfm1113 Air flow factor cfm/Btuh0.011 Air flow factor cfm/Btuh0.049Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-16 10:49:42Right-Suite® Universal 2019 19.0.07 RSU08101 Page 1...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 3 2 Exposed wall 161.0 ft 29.0 ft 3 Room height 9.8 ft 9.0 heat/coolft 4 Room dimensions ft14.0x15.0 5 Room area 2124.0 ft²210.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.901.90 1.181.18 45 45 86 53 0 0 0 0 .WW 12E-0sw12E-0sw 0.0680.068 ee 1.901.90 1.181.18 396 311 593 368 0 0 0 0 .GG 10B-v10B-v 0.6000.600 ee 16.8016.80 31.4531.45 41 2 685 1283 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 41.9541.95 15 1 235 629 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 34.0434.04 9 1 118 306 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 35.1635.16 20 1 263 703 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ss 1.901.90 1.181.18 351 339 645 401 126 126 240 149 GG 4A5-2ob4A5-2ob 0.5600.560 ss 15.6815.68 16.1616.16 12 12 188 194 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.901.90 1.181.18 741 637 1213 754 135 120 228 142 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 15 1 235 629 15 1 235 629 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 34.0434.04 18 2 237 613 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 35.1635.16 30 2 395 1055 0 0 0 0 GG 4A5-2ovd4A5-2ovd 0.4700.470 ww 13.1613.16 35.6135.61 41 2 537 1453 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 2124 2124 3368 2906 210 210 333 287 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 2124 161 4458 0 210 29 803 0 6 c) AED excursion 519 165 Envelope loss/gain 13257 11867 1840 1372 12 a) Infiltration 3405 912 580 155 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 15 3450 2 460 Appliances/other 3700 0 Subtotal (lines 6 to 13)16662 19929 2419 1987 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 9 7 14 Subtotal 16662 19929 2428 1995 15 Duct loads 22%14%3717 2819 22%14%542 282 Total room load 20379 22748 2970 2277 Air required (cfm)Air required (cfm)221 1113 32 111 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-16 10:49:42Right-Suite® Universal 2019 19.0.07 RSU08101 Page 2...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name BATH 3 BATH 2 2 Exposed wall 5.0 ft 5.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.0x11.0 ft5.0x11.0 5 Room area 55.0 ft²55.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.901.90 1.181.18 0 0 0 0 0 0 0 0 .WW 12E-0sw12E-0sw 0.0680.068 ee 1.901.90 1.181.18 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 ee 16.8016.80 31.4531.45 0 0 0 0 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ss 1.901.90 1.181.18 45 39 74 46 45 39 74 46 GG 4A5-2ob4A5-2ob 0.5600.560 ss 15.6815.68 16.1616.16 6 6 94 97 6 6 94 97 WW 12E-0sw12E-0sw 0.0680.068 ww 1.901.90 1.181.18 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 GG 4A5-2ovd4A5-2ovd 0.4700.470 ww 13.1613.16 35.6135.61 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 55 55 87 75 55 55 87 75 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 55 5 138 0 55 5 138 0 6 c) AED excursion -20 -20 Envelope loss/gain 394 199 394 199 12 a) Infiltration 100 27 100 27 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)494 225 494 225 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 11 9 11 9 14 Subtotal 505 234 505 234 15 Duct loads 22%14%113 33 22%14%113 33 Total room load 618 267 618 267 Air required (cfm)Air required (cfm)7 13 7 13 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-16 10:49:42Right-Suite® Universal 2019 19.0.07 RSU08101 Page 3...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 HALL 2 Exposed wall 35.0 ft 0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft15.0x15.0 ft10.0x4.0 5 Room area 225.0 ft²40.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.901.90 1.181.18 45 45 86 53 0 0 0 0 .WW 12E-0sw12E-0sw 0.0680.068 ee 1.901.90 1.181.18 135 120 228 142 0 0 0 0 .GG 10B-v10B-v 0.6000.600 ee 16.8016.80 31.4531.45 0 0 0 0 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 41.9541.95 15 1 235 629 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ss 1.901.90 1.181.18 135 135 257 160 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ss 15.6815.68 16.1616.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.901.90 1.181.18 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 GG 4A5-2ovd4A5-2ovd 0.4700.470 ww 13.1613.16 35.6135.61 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 225 225 357 308 40 40 63 55 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 225 35 969 0 40 0 0 0 6 c) AED excursion -108 -4 Envelope loss/gain 2132 1184 63 50 12 a) Infiltration 700 187 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2832 1831 63 50 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 9 7 -63 -50 14 Subtotal 2841 1838 0 0 15 Duct loads 22%14%634 260 22%14%0 0 Total room load 3475 2098 0 0 Air required (cfm)Air required (cfm)38 103 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-16 10:49:42Right-Suite® Universal 2019 19.0.07 RSU08101 Page 4...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name GREAT ROOM DINING 2 Exposed wall 19.0 ft 12.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft430.0x1.0 ft14.0x12.0 5 Room area 430.0 ft²168.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.901.90 1.181.18 0 0 0 0 0 0 0 0 .WW 12E-0sw12E-0sw 0.0680.068 ee 1.901.90 1.181.18 171 110 210 130 0 0 0 0 .GG 10B-v10B-v 0.6000.600 ee 16.8016.80 31.4531.45 41 2 685 1283 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 35.1635.16 20 1 263 703 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ss 1.901.90 1.181.18 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ss 15.6815.68 16.1616.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.901.90 1.181.18 0 0 0 0 108 67 128 80 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 GG 4A5-2ovd4A5-2ovd 0.4700.470 ww 13.1613.16 35.6135.61 0 0 0 0 41 2 537 1453 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 430 430 682 588 168 168 266 230 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 430 19 526 0 168 12 332 0 6 c) AED excursion -235 515 Envelope loss/gain 2366 2470 1264 2277 12 a) Infiltration 380 102 240 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 2 460 Appliances/other 1200 0 Subtotal (lines 6 to 13)2746 4692 1503 2801 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 23 18 0 0 14 Subtotal 2769 4710 1503 2801 15 Duct loads 22%14%618 666 22%14%335 396 Total room load 3387 5377 1839 3197 Air required (cfm)Air required (cfm)37 263 20 156 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-16 10:49:42Right-Suite® Universal 2019 19.0.07 RSU08101 Page 5...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN LAUNDRY 2 Exposed wall 13.0 ft 10.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft14.0x13.0 ft15.0x10.0 5 Room area 182.0 ft²150.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.901.90 1.181.18 0 0 0 0 0 0 0 0 .WW 12E-0sw12E-0sw 0.0680.068 ee 1.901.90 1.181.18 0 0 0 0 90 81 154 96 .GG 10B-v10B-v 0.6000.600 ee 16.8016.80 31.4531.45 0 0 0 0 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 34.0434.04 0 0 0 0 9 1 118 306 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ss 1.901.90 1.181.18 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ss 15.6815.68 16.1616.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.901.90 1.181.18 117 108 206 128 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 34.0434.04 9 1 118 306 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 GG 4A5-2ovd4A5-2ovd 0.4700.470 ww 13.1613.16 35.6135.61 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 182 182 289 249 150 150 238 205 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 182 13 360 0 150 10 277 0 6 c) AED excursion -97 -97 Envelope loss/gain 973 587 787 510 12 a) Infiltration 260 70 200 54 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 1 230 Appliances/other 2000 500 Subtotal (lines 6 to 13)1233 3116 987 1294 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1233 3116 987 1294 15 Duct loads 22%14%275 441 22%14%220 183 Total room load 1507 3557 1208 1477 Air required (cfm)Air required (cfm)16 174 13 72 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-16 10:49:42Right-Suite® Universal 2019 19.0.07 RSU08101 Page 6...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name 1/2 BATH WIC. 2 Exposed wall 0 ft 0 ft 3 Room height 9.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft5.0x5.0 ft128.0x1.0 5 Room area 25.0 ft²128.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.901.90 1.181.18 0 0 0 0 0 0 0 0 .WW 12E-0sw12E-0sw 0.0680.068 ee 1.901.90 1.181.18 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 ee 16.8016.80 31.4531.45 0 0 0 0 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ss 1.901.90 1.181.18 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ss 15.6815.68 16.1616.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.901.90 1.181.18 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 GG 4A5-2ovd4A5-2ovd 0.4700.470 ww 13.1613.16 35.6135.61 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 25 25 40 34 128 128 203 175 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 25 0 0 0 128 0 0 0 6 c) AED excursion -3 -14 Envelope loss/gain 40 31 203 161 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)40 31 203 161 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 40 31 203 161 15 Duct loads 22%14%9 4 22%14%45 23 Total room load 48 36 248 184 Air required (cfm)Air required (cfm)1 2 3 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-16 10:49:42Right-Suite® Universal 2019 19.0.07 RSU08101 Page 7...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name TOILET MASTER BEDROOM 2 Exposed wall 0 ft 16.0 ft 3 Room height 12.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft6.0x6.0 ft236.0x1.0 5 Room area 36.0 ft²236.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.901.90 1.181.18 0 0 0 0 0 0 0 0 .WW 12E-0sw12E-0sw 0.0680.068 ee 1.901.90 1.181.18 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 ee 16.8016.80 31.4531.45 0 0 0 0 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ss 1.901.90 1.181.18 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ss 15.6815.68 16.1616.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.901.90 1.181.18 0 0 0 0 192 162 308 192 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 35.1635.16 0 0 0 0 30 2 395 1055 GG 4A5-2ovd4A5-2ovd 0.4700.470 ww 13.1613.16 35.6135.61 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 36 36 57 49 236 236 374 323 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 36 0 0 0 236 16 443 0 6 c) AED excursion -4 349 Envelope loss/gain 57 45 1521 1919 12 a) Infiltration 0 0 426 114 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13)57 45 1947 2493 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 57 45 1947 2493 15 Duct loads 22%14%13 6 22%14%434 353 Total room load 70 52 2381 2846 Air required (cfm)Air required (cfm)1 3 26 139 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-16 10:49:42Right-Suite® Universal 2019 19.0.07 RSU08101 Page 8...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 Exposed wall 6.0 ft 6.0 ft 3 Room height 12.0 heat/coolft 12.0 heat/coolft 4 Room dimensions ft6.0x6.0 ft108.0x1.0 5 Room area 36.0 ft²108.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12E-0sw12E-0sw 0.0680.068 nn 1.901.90 1.181.18 0 0 0 0 0 0 0 0 .WW 12E-0sw12E-0sw 0.0680.068 ee 1.901.90 1.181.18 0 0 0 0 0 0 0 0 .GG 10B-v10B-v 0.6000.600 ee 16.8016.80 31.4531.45 0 0 0 0 0 0 0 0 .GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 11 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 34.0434.04 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ee 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ss 1.901.90 1.181.18 0 0 0 0 0 0 0 0 GG 4A5-2ob4A5-2ob 0.5600.560 ss 15.6815.68 16.1616.16 0 0 0 0 0 0 0 0 WW 12E-0sw12E-0sw 0.0680.068 ww 1.901.90 1.181.18 72 72 137 85 72 63 120 75 GG 4A5-2ob4A5-2ob 0.5600.560 ww 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 34.0434.04 0 0 0 0 9 1 118 306 GG 4A5-2ov4A5-2ov 0.4700.470 ww 13.1613.16 35.1635.16 0 0 0 0 0 0 0 0 GG 4A5-2ovd4A5-2ovd 0.4700.470 ww 13.1613.16 35.6135.61 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 36 36 57 49 108 108 171 148 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 36 6 166 0 108 6 166 0 6 c) AED excursion -14 117 Envelope loss/gain 360 120 576 645 12 a) Infiltration 160 43 160 43 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)520 163 736 688 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 520 163 736 688 15 Duct loads 22%14%116 23 22%14%164 97 Total room load 636 186 900 785 Air required (cfm)Air required (cfm)7 9 10 38 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Apr-16 10:49:42Right-Suite® Universal 2019 19.0.07 RSU08101 Page 9...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name POWDER 2 Exposed wall 5.0 ft 3 Room height 9.0 heat/coolft 4 Room dimensions ft8.0x5.0 5 Room area 40.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Load number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12E-0sw 0.068 n 1.90 1.18 0 0 0 0 .W 12E-0sw 0.068 e 1.90 1.18 0 0 0 0 .G 10B-v 0.600 e 16.80 31.45 0 0 0 0 .G 4A5-2ob 0.560 e 15.68 41.95 0 0 0 0 11 G 4A5-2ov 0.470 e 13.16 34.04 0 0 0 0 G 4A5-2ov 0.470 e 13.16 35.16 0 0 0 0 W 12E-0sw 0.068 s 1.90 1.18 0 0 0 0 G 4A5-2ob 0.560 s 15.68 16.16 0 0 0 0 W 12E-0sw 0.068 w 1.90 1.18 45 45 86 53 G 4A5-2ob 0.560 w 15.68 41.95 0 0 0 0 G 4A5-2ov 0.470 w 13.16 34.04 0 0 0 0 G 4A5-2ov 0.470 w 13.16 35.16 0 0 0 0 G 4A5-2ovd 0.470 w 13.16 35.61 0 0 0 0 C 16X19-0md 0.408 -1.59 1.37 40 40 63 55 F 22A-tpl 0.989 -27.69 0.00 40 5 138 0 6 c) AED excursion -11 Envelope loss/gain 288 97 12 a) Infiltration 100 27 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)388 124 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 388 124 15 Duct loads 22%14%86 18 Total room load 474 141 Air required (cfm)5 7 2020-Apr-16 10:49:43 Right-Suite® Universal 2019 19.0.07 RSU08101 Page 1 ...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Job:Duct System Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information CALLAHAN RESIDENCEFor: 504 E. MIDWAY RD., PORT ST. LUCIE, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0.28in H2O0.28 Available static pressure in H2O0.22in H2O0.22 Supply / return available pressure 0.110 / 0.110 in H2O in H2O0.110 / 0.110 Lowest friction rate in/100ft0.500in/100ft0.500 Actual air flow cfm1113cfm221 Total effective length (TEL) ft160 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 70.02.8VlFx0x04.00.5002136c1/2 BATH st3110.042.5VlFx0x04.00.500137267cBATH 2 st3110.038.6VlFx0x04.00.500137267cBATH 3 st3110.050.4VlFx0x06.00.500103382098cBEDROOM 2 st3110.039.4VlFx0x06.00.500111322277cBEDROOM 3 st290.024.6VlFx0x07.00.500156203197cDINING st290.031.2VlFx0x07.00.500132182688cGREAT ROOM st290.020.6VlFx0x07.00.500132182688cGREAT ROOM-A st290.025.4VlFx0x08.00.500174163557cKITCHEN 70.06.4VlFx0x05.00.50072131477cLAUNDRY st190.024.5VlFx0x05.00.5003810785cMASTER BATH st190.022.3VlFx0x07.00.500139262846cMASTER BEDROOM st190.028.7VlFx0x04.00.50075141cPOWDER st190.019.5VlFx0x04.00.5003152cTOILET st190.022.9VlFx0x04.00.50097186cWIC st190.025.5VlFx0x04.00.50093184cWIC. Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 83 240 0.500 544 9.0 0x0 VinlFlx st2 st2 Peak AVF 156 834 0.500 780 14.0 0x0 VinlFlx st1 Peak AVF 51 205 0.500 376 10.0 0x0 VinlFlx 2020-Apr-16 10:49:43 Right-Suite® Universal 2019 19.0.07 RSU08101 Page 2 ...ocuments\Wrightsoft HVAC\CALLAHAN RESIDENCE.rup Calc = MJ8 Front Door faces: S Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 2210 1113 0 0 0 0 x0 0 VlFx