Loading...
HomeMy WebLinkAbout2020-04-19 Mabel Ooms PRODUCT APPROVAL SUBMITTAL AFFIDAVIT BUILDING PERMIT: BUILDING ADDRESS: ST. LUCIE COUNTY, FLORIDA CONTRACTOR: GLENN DAVIS CBC1261228 PLAN REVIEW REVISIONS OPENING SCHEDULE SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS, & SKYLIGHTS: OPENING PRODUCT MODEL # MANUFACTURER GLASS ATTACHMENT METHOD PRODUCT DESIGN ID APPROVAL PRESSURES 3068 FIBER-CLASSIC HEAD: 1/4" X 3-3/4" TAPCONS SPACED 3" FROM CORNERS, 3" & 6" FROM MULLION. JAMBS: EXTERIOR SWING DOOR THERMA-TRU 3/16" TEMPERED 1/4" X 3-3/4" TAPCONS SPACED 3" FROM CORNERS, 14" O.C. MAX. SILL: 1/4" DIA. X 2-1/4" FL15225.5 +40.0 - 40.0 PSF W/ SDLT. SMOOTH STAR TAPCONS SPACED 3" FROM CORNERS, 3" & 6" FROM MULLION. MASTER PLAN REVISION STEEL TRACK BRACKET TO WOOD: 5/16" X 1-5/8" LAG SCREW(FULLY THREADED) HEX 2-3-19 16070 OVHD OVERHEAD DOOR MODEL 9100 WAYNE DALTON « >> WASHER HEAD ONE PER BRACKET- (5) BRACKETS TOTAL PER VERTICAL STEEL TRACK FL9174.6 +39.2 -43.7 PSF ALL ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) 8068 S.G.D. SLIDING GLASS DOOR SERIES 420 MI WINDOWS AND DOORS 3/16" TEMPERED HEAD: SPACED 6" FROM CORNERS, 17" O.C. MAX. JAMBS: SPACED 6" FROM CORNERS, 17" FL15332.6 +/- 40.0 PSF (MIN) O.C. MAX. SILL: SPACED 6" FROM CORNERS, 17" O.C. MAX. w ALL ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) 0 WINDOW 185 SH MI WINDOWS AND DOORS 1/8" ANNEALED ANCHORS 2" FROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX. FL17499.2 +/- 60.0 PSF (MIN) o W � � ALL ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) w q co 0 WINDOW 185 SH MI WINDOWS AND DOORS 1/8" ANNEALED ANCHORS 2" FROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX. FLi7499.2 +/- 60.0 PSF (MIN) Q; � qq PROVIDE LADDER REINFORCING & WALL TIES AT ALTERNATE LAYERS, PROVIDE (2) 1/4" DIA. 0 GLASS BLOCK 8"X8"x4" MULIA, INC. TAPCONS AT EACH WALL TIE WITH 1-1/4" MIN. EMBEDMENT NOA 18-0129.17 +/- 90.0 PSF (MIN) q 0 (.� \ � O ALL ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) N Q WINDOW 185 SH MI WINDOWS AND DOORS 1/8" ANNEALED ANCHORS 2" FROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX. FL17499.2 +/- 60.0 PSF (MIN) 44 MASONRY ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT), WOOD ANCHORS ^�I 0 FIXED GLASS FIXED 185 MI WINDOWS AND DOORS 1/8" ANNEALED ARE #10 WOOD SCREW (1-3/8" MIN. EMBEDMENT). MASONRY ANCHORS: 3" FROM CORNERS, FL15349.1 +/- 55.0 PSF (MIN) W N �-­I Q41 3 AT SILL. WOOD ANCHORS: 3" FROM CORNERS, 16"O.C. MAX. w W \ Q) � o 30# ASPHALT TAMCO BUILDING 30# FELT, APPLIED SINGLE FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2", FASTENED WITH 1" ROUND UNDERLAYMENT SATURATED PRODUCTS INC. « >> PLASTIC CAP, METAL CAP NAILS OR NAILS AND TIN TABS ATTACHED TO SHEATHING WITH 2 STAGGERED ROWS IN THE FIELD OF FL12328.7 CAI `I ORGANINC FELT THE SHEET WITH A MAXIMUM FASTENER SPACING OF 12" O.C., AND 1 ROW AT THE OVERLAPS FASTENED 6" O.C. C) ALV.ROOFING NAILS,11 OR 12 GA.,WITH AT LEAST 3/8"DIA.HEADS,LONG ENOUGH TO ASPHALT SHINGLES HERITAGE TAMCO BUILDING « >> ENETRATE THROUGH PLYWOOD. USE 4 NAILS PER SHINGLE PLACED 6-1/8"ABOVE BUTT FL18355.1 PRODUCTS, INC. DGE,APPROX.1 &13.1/2 FROM EACH END&1/2 ABOVE EACH CUTOUT. AMERICAN CONSTRUCTION PROVIDE T-NAILS AT 12" O.C. IN F-CHANNEL SLOT ON MASONRY, PROVIDE TRIM NAILS EXTERIOR SOFFIT ALUMINUM SOFFIT MATERIALS « » ATTACHED THROUGH FASCIA AT 16" O.C. FL12019 +/- 70.0 PSF (MIN) u7 LO rn LL ANCHORS ARE 1/4"DIA.TAPCONS(1-1/4"MIN.EMBEDMENT) FL 22270.1 PER MANUF. HURRICANE SHUTTERS 8"GAUGE GALV. EASTERN METAL SUPPLY >> PACING OF ANCHORS PER MANUFACTURER'S SPAN CHART SPAN CHARTS C) � ;TEEL STORM « ANELS �■.� co U 0 J M o (!) _ Q LL Op x Lu p O N TABLE R301.2(1) Z 0 Uj J O CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA LL J m Q N_ GROUND WIND DESIGN SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE BARRIER FLOOD AIR MEAN m Q IL � V SNOW Speed Topographic DESIGN r Weatheringe Frost lineb Termite DESIGN UNDERLAYMENT HAZARDS9 FREEZING ANNUAL 1 have reviewed the above product approval COMPONENTS AND CLADDING WIND PRESSURES PER LOAD (mph) eflectsk(NA) CATEGORY depth TEMP REQUIREDh INDEX TEMPI information and approved it. PROJECT & CODE DATA 2017 FLORIDA BUILDING CODE Q L) ¢ ti U N/A See Fig.R301.2(4) N/A Negligible WA Very N/A N/A N/A Z Heavy Name:�Z�u�,� /�t�5�t USING INTERIOR ZONE COEFFICIENTS � U - W For SI: 1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. U') O . *PLANS DESIGNED TO COMPLY WITH THE 2017 FLORIDA BUILDING CODE (6TH EDITION) AREA OF OPENINGS DESIGN ti = a. Weathering is"neglible"for concrete as determined from the Weathering Probability Map[Figure R301.2(3)]. The grade of masonry units shall be determined signature (SQ. �•) PRESSURE co a from ASTM C 34,C 55,C 62,C 73,C 90,C 129,C 145,C 216 or C 652. IJJ Reserved. � 2ov173, 0= TYPE OF CONSTRUCTION: CBS X FRAME -j c. Termite infestation per Figure basic win speed heavy" Certification Number: 0 to 19.9 27.7 PSF / -30.0 PSF IL d. Wind speed shall be from the basic wind speed map[Figure R301.2(4)]. Wind exposure category shall be determined on a site-specific basis in accordance with Section tdo1e des. L / /�y,� 20 TO 49.9 e, The outdocedesign dry-bulb temperature shall a selected pefrom the columns tl c 1/2-percent values eatherter from Appende rofthebythe Building Code, Date' "7 /I 9 l �tJ BUILDING DESIGN: ENCLOSED X OPEN PARTIALLY ENCLOSED 26.4 PSF / -28.0 PSF Plumbing. Deviations from the Appendix D temperatures shall be permitted to reflect local Gimates or local weather experience as determined by the building official. f. Reserved. g. The applicable governing body shall,by local ftoodplain floodpiain management ordinance,specify(a)the date of the jurisdiction's entry into the National Flood ULTIMATE DESIGN WIND SPEED•140 MPH 160 MPH X 170 MPH 50 TO 99.9 24.7 PSF / -27.0 PSF Insurance Program(date of adoption of the first code or ordinance for management of flood hazard areas),(b)the date(s)of the Flood Insurance Study and(c)the panel numbers and dates of all currently effective FIRM and FBFM,or other flood hazard map adopted by the authority having jurisdiction,as amended. 1 00 TO 499.9 h. Reserved. NOMINAL DESIGN WIND SPEED: 124 MPH 23.5 PSF / -25.0 PSF j. Reserved. DRAWING INDEX 500 AND ABOVE 20.6 PSF / -22.0 PSF PROJECT k. Reserved. BUILDING CATEGORY: II USING END ZONE COEFFICIENTS NO. 17-015-001 NOTE: THE CELLULOSE INSULATION TO BE USED COMPLIES EXPOSURE: B AREA OF OPENINGS DESIGN DATE DRAWN 3-22-20 WITH THE REQUIREMENTS OF SECTION R302.10 AND MEETS CVR INDEX / PROJECT INFORMATION THE FLAME SPREAD INDEX OF NOT MORE THAN 25 AND THE INTERNAL PRESSURE COEFFICIENT: +/- 0.18 (SO. FT.) PRESSURE DRAWN BY MCA SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450. A-1.0 FOUNDATION PLAN IMPORTANCE FACTOR: 1 0 to 19.9 27.7 PSF / -37.0 PSF CAYMAN 1560 B1 A-2.0 FLOOR PLAN MEAN BUILDING HEIGHT: 15' 20 TO 49.9 26.4 PSF / -34.0 PSF NOTE: THE WALL AND CEILING FINISHES COMPLIES WITH THE A-3.0 BUILDING ELEVATIONS 50 TO 99.9 24.7 PSF / -31.0 PSF LIVING 1560 SQFT REQUIREMENTS OF SECTION R302.9.1 AND MEETS THE OVERHANG: 1.33 FT ROOF PITCH: 6 /12 100 TO 499.9 23.5 PSF / -28.0 PSF FLAME SPREAD INDEX OF NOT MORE THAN 200 AND A-4.0 ROOF / FRAMING PLAN COMPONENTS AND CLADDING WIND PRESSURES: 500 AND ABOVE 20.6 PSF / -22.0 PSF GARAGE 372 SQFT COMPLIES WITH THE REQUIREMENTS OF SECTION R302.9.2 A-5.0 ELECTRICAL PLAN LANAI 144 SQFT AND MEETS THE SMOKE-DEVELOPED INDEX OF NOT MORE ROOF DEAD LOAD: (SHINGLES) 17 PSF (TILE) THAN 450. A-6.0 WALL SECTIONS / NOTES SHUTTERS: YES X NO ENTRY 86 SQFT A-6.1 WALL SECTIONS / NOTES ATTIC VENTILATION CALCULATION: IMPACT RESISTANT ASSEMBLY: YES NO X VENTILATION REQUIRED: A-6.2 WALL SECTIONS / NOTES TOTAL 2162 SQFT ATTIC AREA - 2,353.3 SQ. FT. ROOF LOAD: CUBIC VOLUME OF VENTILATION AREA REQUIRED = 1,918.0 SQ. FT. / 150 (F.B.C. R806.2) = 12.78 SO. FT. A-7.0 INTERIOR ELEVATIONS PARAMETERS: TOP CHORD: LIVE LOAD: 20 PSF DEAD LOAD: 10 PSF CONDITIONED SPACE - LINEAR FEET OF 16" WIDE SOFFIT = 165.5', 12" WIDE SOFFIT = 43.1', 8" WIDE SOFFIT = 49.0' - MICHAEL C. ANDERSON SQUARE FOOTAGE OF SOFFIT = (165.5' X 1.33') + x ,.N + (49.0' x .6T) = 296.0 HVAC PLAN - 12,480 CUBIC FEET NET FREE AREA OF VENTILATION FOR ACM TRIPLE 4 OR QUAD 4 FULL VENT NARROW RROW PATTERN SOFFIT = 11.7 S A8•0 BOTTOM CHORD: LIVE LOAD: 10 PSF DEAD LOAD: 7 PSF4 SQ. IN. / SQ. FT. VENTILATION PROVIDED: (NON-CONCURRENT) SOFFIT VENTILATION PROVIDED = 296.0 SQ. FT. X 11.74 SO. IN. / SQ. FT. X 1 SQ. FT. / 144 SO. IN. = 24.14 SQ. FT. CONCLUSION: = SHEET VENTILATION PROVIDED = 24.14 SQ. FT. > VENTILATION REQUIRED = 15.62 SQ. FT., THEREFORE SOFFIT VENTILATION IS ADEQUATE -- � MICHAEL C. ANDERSON, ARCHITECT OF RECORD -r ����� FL. LIC. AR0017305 1020 SW PROANCETOWN LANE, PORT ST. LUCIE, FL 34953 CVR (772)418-2118 ; . PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE-RESIDENTIAL (6TH EDITION) FL. LIC. AR0017305 N 6x6 - 1Ox10 WWF CONC. 6x6 - 1Ox10 WWF w OR FIBER MESH SLAB OR FIBER MESH Q CONC. 8" > SLAB PLAN REVIEW REVISIONS d VARIES --- 0 GRADE �- - 0 2 2-# _I 2 #5 BA S BADS 811 BARS 8"1 l-4 s 1'-4" 2'-0„ A DETAIL g DETAIL C DETAIL 1 1 1 MASTER PLAN REVISION 2-3-19 6x6 - 10x10 WWF CONC. w OR FIBER MESH SLAB Q CONC. 19_0» SLOPE ? SLAB o GRADE 2_ GRADE 2- 1 12"(MIN) 2 AAS 22'-0" 16'-0" BA S BELOW 89 -4' 1'-4" O q 6'-8" 3'-10" 6'-8" 3'-10" 1'-0" 36"X36'X16" DEEP D DETAIL F DETAIL cy) CONC. FTG. EACH WAY W/ (3) #5 1'-0" 1 1 C D 7, ,E q �1 ■ ■ ■ ■ ■ ■ - - - - - - - - - - - - - ■ ■ CONC. 1-#5 CONC. 1-#5 q O ~ I ■ SLAB BAR SLAB BAR \ O I I A I � W N 4 - ry HB 1 I of I G o W I I � 1 I00 � W I I °' G DETAIL H DETAIL A _ A 00 1 1 ~8'-8" 3'-8" ILoI I ti ■ I 1 I F 5 1/2" FRAME ■ ■ 7 5/8" ({BLOCK w \ I - `L O — — — — CONC. CONC. 2-#5 CONC. Of — -I 00 SLAB >ft SLAB BAR SLAB > CO i J RECESS SLAB I 14- — C� I i FOR S.G.D. I _I • • -I 0 I II I L 5 11 1 1'-4" BARS 4411 g" N i LAV I I ■ I I I J DETAIL - S.G.D. K DETAIL H1 DETAIL i� II of I 1 1 1 ao 0 11 I CONC. d `n LAV I I CONC. 8 8 N SHOWER SLAB Lo SLAB VARIES1. CONC. RECESS Lo I 0) / ■ 3 1 2 10'-10 5/8" o SLAB AT WALL w ni ---- ---- -- • ---- __--- GRADE It o0 0 m 0 7 5/8" 1 1/ o RE�ESS 2_�# �I 4„ 8» M I WC ® I I I I BAf� 3 ;mm4 � _ � 0) SINK W/ O ■ II I I 1 1 I _ G1 DETAIL _ J Um) �c ° 0 o�0DISP• DETAIL MDTAIL 4 � LL NSHWR. rh o' - 0 z W > 11'-7 5 8" LL a --Jl Q 0Q N -poI RECESS SLAB REFERENCE I I I A 1 z c j U I 3 1/2 FOR I I n PIPE SLEEVE (DIA. W F= cco Q a SHOWER FINISH FLOOR 1 LARGER THAN PIPING Q U � N U ■ I 4" 2500 PSI CONC. SLAB W/ I I THRU FTG.) I 1 2" V.T.R. w W W to ao I FIBER MESH, ON 6 MIL. POLY 3" MIN. r` JIL " '� co cn Z I VAPOR BARRIER OVER TERMITE ■ FTG. PER TREATED COMPACTED CLEAN DEPTH I �\\I\3 V.T.R. ri d FILL COMPACTED TO A MINIMUM 3" MIN. DETAIL i I I DENSITY OF 95% AS _ 3 MIN., I I �\\ I J DETERMINED BY ASTM D-1557 — 00 NOTE: ALL FOOTINGS DESIGNED FOR FOOTING & I I \ �� 2" I " 1 w. 1 1 2 500 PSF SOIL BEARING CAPACITY I » 12 V.T.R. rHl REBAR 2 1 SINK JII- r7 C° 1 -0 1 -0 TRANSITION LAV I » �i I C0 I INDICATES C.M.U. CELL FILLED 1 mq 1 I rA W/ CONCRETE AND (1) #5 VERT. �I I I LAV '' I cD I REBAR CONT. FROM FOOTING TO — — — — — — — — !AC — d- — — PIPE THRU 1 TIE BEAM (TYPICAL) r ■ PF FTG. DETAIL PROJECT ■ TUB/SHWR I " I 1 3 2 I I 3" WASHER NO. 17-015-001 rHl I a WC 61 1 I 7'-11 7/ _ 2„ I W.C. DATE i� DRAWN 3 LAV 1 CONC. TUB I 2" 3„ 3" V.T.R.I DRAWN BY MCA0 ■ '�!/ I I A/C PAD SHWR. �r I 3„ �- - - - - - - .� I � ' I i CAYMAN 1560B1 r I DIAGONAL I I I I I LIVING 1560 SQFT I ( I COND DISTANCE I 1 CLEAN 0 I 2'-10" 2'-6" W Lol 2»"1 r I o I W I DIMENSION FROM I I OUT GARAGE 372 SQFT I 0 I INSIDE CORNER I w»C. I 3" 3" MAIN 1'-1 5, 8" I p ao I A TO \ I I D N M I D OF FORMBOARDS I 1 LANAI 144 SQFT 1 d ( 1 0 1 ' AC 69 — 1 " 2" 1 OR SEPTIICSEWER TANK ■ I N ENTRY 86SQFT � I • . I I AD = 59' - 10" SHwR. SCHEMATIC PLUMBING RISER I I I I BE = 6 g'— 6" TOTAL 2162 SQFT s I I ■ 0 � _ i I BF = — 3 I A o ,- o CUBIC VOLUME OF I I I I I HB DIMENSIONS ARE MICHAEL C. ANDERSON CONDITIONED SPACE _ i po i- SLOPE DOWN 1 I I _ _ I F AT GAR. DOOR m00 I o ROUNDED TO THE �r�~�h'~'' �, 12,480 CUBIC FEET X'o I I CLOSEST INCH I- - - - - - - - - - - c'� - -j . ■ SHEET B G ti- 4'-4" 1 A FOUNDATION PLAN MICHAEL C. ANDERSON, ARCHITECT OF RECORD , ' l j[Z0 20" 16'-0" 20" FL. LIC. AR0017305 1/4" = 1'-0" 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 f = :`� �- loO 12'-4" 6'-4" 19'-4" (772)418-211$ 38'-0" PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE-RESIDENTIAL (6TH EDITION) FL. LIC. AR0017305 PLAN REVIEW REVISIONS MASTER PLAN REVISION 2-3-19 ti 22'-0" 16'-0" DOOR SCHEDULE � � 10'-6" 1'-4" O � Q4 d' 0 SIZE FRAME AREA U FACTOR SHGC Q REMARKS W C/) q CYJ Og +6'-8" g +6'-8" C.B. COLS.- `� 1 3068 W/ 64"X7"X2 1 g 05 1 EXT. DOOR HDR. HT. O HDR. HT. _I SIDE LIGHTS 6.2 S.F. MUNTINS IN SDLTS n TOP + 6'-8" A.F.F. O "� 96X80" .58 .25 1 EXT. DOOR q Q ■ ■ ■ ■ ■ ■ ■ ■ 2 8068 S.G.D. R/S �"�- P.C. HDR. ABV.- - ■ 53.3 S.F. \ 0 EGRESS - - BOT. + 6'-8" A.F.F. GARAGE DOOR W/ ® r $'=0" CLG. - - - - - 3 2868 SOLID CORE 1 SELF CLOSING 44 DEVICE � 44 ^� 4 / 8' 8" CLG. ^y o �' v 15'-s 3 4" 15 -0 COVERED PATIO HB , 0 4 2868 6 INT. DOOR W i 1 8 CLG. I - I2'-o" ■ 8 CLG. I , W O R/S 1 TYP. 8'-0" 4'-0" I 5 2068 POCKET 1 INT. DOOR W 0 _ R/S_ + I I w I I IN I 20 I 6 2068 1 INT. DOOR r CD (nW ■ ® 1 MASTER BEDROOM ■ ■ ■ ■ 0 a' 1 8' CLG. I COFFER 1 7 1668 1 INT. DOOR r zz L - - - - - - - - - J 15 -9 1/4" 0 - - ® 1 14 R/S . 8 4068 BIPASS 2 INT. DOOR 0 N "' DINING ROOM ■ �1 = 10 M.C.- VAULTED CLG. 9 2068 BIFOLD 1 INT. DOOR N 1 1 `O 7 8' CLG._011 1 B ■ 0 0 o O 10 2868 POCKET 2 INT. DOOR 04 1-1 1 „ +6'-8" HDR. HT. 00 15 2 1/4 10'-3" ■ HDR. HT. 0 1 11 16070 OVHD. DOOR 1 GARAGE DOOR in O r I FLAT 5'-0" I BARTOP T_ 0 "IQ T_ M N 00cn GREAT DOOM ---_-___ WINDOW SCHEDULE o CD I CATHEDRAL CLG. fl co - " 0 1 ; ; O SIZE FRAME AREA U FACTOR SHGC Q REMARKS c, J ti w J c x SINK W/ ■ Q 110DISP. A 35 SH 52.125"X62" .55 .22 ° Q CO ■ I IID o 1 MUNTINs = ir N co II 0 22i4 S.F. z 0 J o 0 B M I I I 0 36 X62 J CO 0 � cv w i 1 11 KITCHEN B 25 SH 15.5 S.F. .49 .24 4 Z -� ti +6'-8" II VAULTED CLG. HDR. HT. �`' N I 11 0 4'W. X 3'-4"H. 48"X40" W � cp U 0 - LI C DEFAULT DEFAULT ~ I ■ I GLASS BLOCK 13.3 S.F. 1 Z N Q � U r� - '� OBSC. TEMPERED x cn LO i BEDROOM N D LG.#3 I » ''� 6.6 5S.F 7.375" W �-- Lu 15 -8 1/4 I 10 -0 1/2 p 1/2 33 SH .54 .25 1 cA Z _ E .56 .25 1 15 LITE 64 W.x36 H. 63.0 X35 X60.0 RX27 M d 10 LEG ■ 7'-4 1/2" 1 4'_4'p 5'-11" EYEBROW (28" LEGS) 14.4 S.F. J 1 8 CLG. RO W I 5 SH. 1W. SHELF ~ H 00 ABV. 7'-9" 8' CLG. 1. WINDOWS, DOORS, AND GARAGE DOORS SHALL COMPLY 4 WITH STANDARD BUILDING CODE WINDLOAD AND EMERGENCY iv R/S O N AC D ■ DRYER EGRESS REQUIREMENTS. M.T. PROJECT �O -Ir 18' C � O V.T.W.■ L +6'-8" 7'_g�� ® 13'-7 1/2" 7'-1 3/4" 18'-3 1/2" NOTES: NO. 17-015-001 31 IN 1. WOOD STUD SPACING: (UNLESS DATE DRAWN 3-22-20 I HDR. ° VAULTED CLG. N10 OTHERWISE NOTED ON PLANS HT 2,_8�� z awl 1 `� -EXTERIOR FRAME WALLS AT 16" O.C. DRAWN BY MCA LO 0< irk O -INTERIOR FRAME BRG. WALLS M.T. _ _ _ -INTERIOR FRAME NON-BRG. WALLS CAYMAN 1560 B1 o R/S = I - - - �n cn ■ ■ I � i I 22"x54" ■ Ac AT 24" O.C. „ LIVING 1560 SQFT N \ i x ATTIC ACCESS COND -KITCHEN CABINET WALLS AT 16 O.C. E HDR. HT. - 2. FRAME WALLS ARE DRAWN 3 1/2" WIDE GARAGE 372 SQFT ® ® 10'-4" UNLESS OTHERWISE NOTED ABV. I GARAGE 3. CONC. BLOCK WALLS ARE DRAWN LANAI 144 SQFT N 8' CLG. 7 5/8" WIDE UNLESS OTHERWISE NOTED o_ I ■ » 4. TOOL CONC. BLOCK JOINTS INSIDE ENTRY 86 SQFT `n 6'-0" 1'-8 3'- 3/4' LG. H ■ GARAGE WALLS (BRUSH & CLEAN) CLG. HT. 0I ■ 5. DOOR & WINDOW ROUGH OPENINGS TOTAL 2162 SQFT SHALL BE PROVIDED BY BUILDER BEDROOM #2 8"W. ARCH ABV. 6. TOP OF TYP. BEARING WALL +8'-0" CUBIC VOLUME OF 8' CLG. SEE ELEV. HB UNLESS OTHERWISE NOTED MICHAEL C. ANDERSON CONDITIONED SPACE _ O TOP OF FOYER SCAR EGRESS x I 7 RED ABOVE HDR. HT. 1 12,480 CUBIC FEET 0 0 11 in ■ ■ ■ ■ Q 8. SEE STRUCTURAL NOTES FOR 00 ■ FLAT ARCH ■ oo m o ■ ■ ■ ■ ADDITIONAL INFORMATION _ SHEET 4'-4" SOFFIT ABV. 1'-4" 1'-4" N FLOOR PLAN MICHAEL C. ANDERSON, ARCHITECT OF RECORD 20» 16 -0 20 FL. LIC. AR0017305A 2mO „ 1/4" = 1'-0" 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 12 -4 6'-4 191-410 (772)418-2118 38'-0" PLANS DESIGNED' TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE-RESIDENTIAL (6TH EDITION) FL. LIC. AR0017305 i ATTACH 1-1/2' X 4-1/2' P.T. BUCK TO BLOCK WITH: CONC. OR MASONRY HEAD: 1/4' X 3-3/4' TAPCONS SPACED 4' FROM CORNERS, 3' & 6' FROM MULLION. JAMBS: 1/4' X 3-3/4' TAPCONS SPACED 4" FROM CORNERS, 18.94' O.C. MAX. 0 .. DRYWALL BOARD O a ° CEMEN7177OUS FINISH DOOR TRIM PERIMETER CAULKING PLAN REVIEW REVISIONS ATTACH DOOR FRAME TO 2X P.T. BUCK WITH: DOOR TRIM HEAD: #10 X 2-1/2' PFH WOOD SCREWS SPACED 4' FROM CORNERS, 3' & 6' FROM MULLION. JAMBS: #10 X 2-1/0 PFH WOOD SCREWS SPACED 4' FROM CORNERS, 18.94' O.C. MAX. 12 HEAD/JAMB DETAIL (2X BUCK) 16 EXT DOOR MASTER PLAN REVISION 3/4'x 4-1/2'P.T. BUCK SET IN DOOR THRESHOLD SET IN BEAD OF CAULK AND 2-3-19 CONC OR MASONRY SEALANT AND SECURED W/ FASTENED TO SILL WITH 1/4" DIA. X 2-1/4' TAPCONS CASE HARD NAILS 0 12'O.C. (MAX) SPACED Y FROM CORNERS, 3' & 6' FROM MUWON O TOP_OF_BLK. P - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - +8'-0" A.F.F. ERIMETER CAULKING FLOOR COVERING DRYWALL BOARD ° a o� CEMEN7I77OUS FINISH DOOR TRIM • •o O •° ° •o 0 PERIMETER CAULKING On°$' O 00° I� ATTACH DOOR FRAME TO BLOCK WITH. DOOR TRIM •O HEAD: 1/4' X 3-3/4" TAPCONS SPACED C CEMENTITIOUS COATING 3` & 6' FROM MULLION. PERIMETER CAULKING ON BLOCK ^y FROM CORNERS, '\I JAMBS: i/4" X 3-3/4" TAPCONS SPACED 4' CONCRETE SLAB co FROM CORNERS, 1&94' O.C. MAX. r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ TOP OF SLAB HEAD/JAMB DETAIL (IX BUCK) SILL DETAIL — — — — — — — +0'=bw_ . .r EXT DOOR EXT DOOR ~ (REF. ELEV.) 12 RIGHT SIDE ELEVATION �6 1/4" = 1'-0" W r W CEMENTITIOUS COATING � ►� STUCCO FINISH ON LATH PERIMETER CAULKING N W CONC. OR MASONRY Lo M ~ ^I 1xP.T. BUCK SET IN _ '�I TOP OF BLK. v1 I� - - - - - - - - - - - - - - - - - - - - - - SEALANT AND NAILED d r \ O ,� -I-8'-0" A.F.F. W/1-1/2" CASE HARDENED 11 -7 5/8 w w J Qo COIL NAILS AT 24" 0/C. 00 MAX. DOOR FRAME co 0 1 -2 7/8 b FASTEN TO SILL W/ „ \ I cfl r SCREWS CEMENTITIOUS COATING DRYWALL BOARD 0 2'-0" 0/C N BO 8" I- ON BLOCK CAULKING 0I DOOR FRAME E-FLOOR COVERING - to p FASTEN THRU BUCK W/ o o = W/3-1/4" x 1/4' (MIN) '�°�o 0. TAPCONS AT 24' 0/C. MAX IN PREDRILLED HOLES ^I TOP OF SLAB BY MANUFACTURER GROUT BED - - — - - - - - - - - - - - - - - - - - - - - - CONCRETE SLAB r 1'-2 7/8" (REF. EV.) JAMB/HEAD DETAIL SILL DETAIL L (SGD) (SGD) O �, REAR ELEVATION U) OVERHANG SEPARATIONS1 1/4" = 1'-0" 1/4" = 1'-0" co U _ rnti co Ix3 OR 1x4 P.T. BUCK SET IN O cl) = LL CD SEALANT AND NAILED ALUMINUM FRAME W/1-1/2'CASE HARDENED FAS7FN THRU BUCK W/ N of COIL NAILS AT 12'O/C 3/16 x3 1/4" TAPCON - 0 CO / � z W J � �O � MAX. SCREWS ®24 0 C J_ m Q co N CONE OR MASONRY MAX. IN PREDRILLED ALUMINUM FRAME HOLES BY MANUFACTURER Z u- N SECURE FRAME TO SILL PERIMETER CAULKING / W11H SILICONE W H Co ('� Qo' CEMEN7177OUS FINISH �G CAULKING 12 Q U N U CONC OR MASONRY 6 F_ Z Q DRYWALL BOARD 14 OR fx4 P.T. BUCK SET IN W W = CAULKING SEALANT AND NAILED �o°oob .Qo 4 F- Z W/1-1/2'CASE HARDENED ° ba ,�,4 N z ALUMINUM FRAME COIL NAILS AT 12'0 C L FASTEN THRU BUCK W/ / _ 3/16'x3 1/4' TAPCON MAX. PRECAST OR POURED O O M (- SCREWS®24'o/C SILL TOP OF BLK. W MAX. INPREDRILLED — — - - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — » — J HOLES BY MANUFACTURER PERIME7ER CAULKING +$ —0 A•F F W PERIMETER CAULKING DRYWALL BOARD F- CEMEN7171OUS FINISH CAULKING HEAD DETAIL JAMB DETAIL SILL DETAIL WINDOW WINDOW WINDOW CEMENTITIOUS COATING �_ ON BLOCK o PROJECT T NO. 17-015-001 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - — _TOP OF SLAB DATE DRAWN 3-22-20 RIDGE HEIGHT — — — — +0'-0" A.F.F. (REF. ELEV.) DRAWN BY MCA 6 SQ. RAISED +17'-10" A.F.F. LEFT SIDE ELEVATION CAYMAN 1560B1 BLOCKS (PROJ. 3/4") `r 12 1 4" = " NOTES W/2" SPACE BTWN. "I �6 CEMENTITIOUS COATING 1'-0 TOP OF ARCH ON LATH LIVING 1560 SQFT +10'-10" A.F.F. 1. WALL FENESTRATION PER FBCR 2017 703.4 GARAGE 372 SQFT DOD 6'-2" ATTACHMENT PER MFRS. 2. PROVIDE FLASHING BETWEEN SLOPED ROOF AND VERTICAL WALL INTERSECTIONS, ENTRY TRUSS BRG._ _ _ _ _ _ _ _ _ _ _ RAD. RECOMMENDATIONS FLASHING SHOULD BE CONTINUOUS OR STEP FLASHING IN CONTINUOUS BED OF LANAI 144 SQFT A.F.F. — — — — — — - 16 OVERHANG PRE-ENGINEERED ROOFING CEMENT. 6"W. RAISED TRIM WDW. HDR. HT. 8 TYPICAL UNLESS ROOF TRUSS (PROJ. 3/4") +10'-4" A.F.F. OTHERWISE NOTED L 1X2 NAILED TO TRUSS TAILS 3. PROVIDE SEALANT PAINTED ON WINDOW / DOOR BLOCK WALL OPENINGS WITH 1X ENTRY 86 SQFT W/ (2)-8d NAILS BUCKS ATTACHED WITH MASONRY NAILS, APPLY SEALANT OVER INSTALLED ,gkTOP OF BLOCK A _ TOP OF BLK. u P-i BUCKS - SEALANT TO BE SHERWIN WILLIAMS CONFLEX OR EQUIVALENT. — — — — — — — — — — — - — — — — — — "I FRAMED WINDOW OPENINGS SHALL HAVE TAPED WINDOW FLASHING - WINDOW TOTAL 2162 SQFT +8'-0" A.F.F. - - - - - - - - - - - - - - - +8'-0" A.F.F. CONCRETE "U" BLOCK WRAP BY WFM MANUFACTURING (SEE DTAIL ON SHEET A6.2). TIE-BEAM TOP COURSE �- ALIGN TOP OF WALL PROJECTION AT tO °0 ® ® TRIM W/ GARAGE MICHAEL C. ANDERSON CONDITIONED SPACE CUBIC VOLUME OF HALL BATH BEYOND r - DOOR HEADER HORIZ. 2X2 NAILED TO _ 0 c° °' VERT. 1X2'S W/ 12d x 12,480 CUBIC FEET CEMENTITIOUS COATING 3-1/4" NAIL ATTACHMENT PER MFRS. RECOMMENDATIONS ON BLOCK BLIG3 WOP OF BANDILL HW/ SEE PI SHEET STAPLES 0 8" O.C. PER MFRS. ,gkTOP SLAB_ RECOMMENDATIONS ; MICHAEL C. ANDERSON, ARCHITECT OF RECORD (REF. ELEV.) FL. LIC. AR0017305 r4 4"W. RAISED BAND (PROJ. RETURN BAND 24" CONTINUOUS VENTED SOFFIT 1-1/2") ALIGN TOP W/ ALONG SIDE WALL(S) SOFFIT DETAIL 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 3mO,.� WINDOW SILL N.T.S. PLANS DESIGNED TO MEET THE REQUIREMENTS OF FRONT ELEVATION THE 2017 FLORIDA BUILDING CODE-RESIDENTIAL (6TH EDITION) FL. LIC. AR0017305 1/41 = 1'-0" PRECAST HEADER SCHEDULE PLAN REVIEW REVISIONS ANCHOR SCHEDULE B-x (SIMPSON STRONG-TIE PRODUCTS MODEL NUMBER) LINTEL CAST CRETE ALLOWABLE ALLOWABLEMEMBER LENGTH TYPE LOAD UPLIFT DESIGNATION MODEL # ALLOWABLE LOADS NAIL PATTERN B-1 208" 8F16-18/1T 950 PLF 404 PLF SIMPSON HETA20 < 1810 > 10-10d x 1 1/2 USE SIMPSON HETA20 FOR ALL TRUSS TO BLOCK CONNECTIONS (U.N.O.) B-2 70" 8F8-1 B/i T 1459 PLF 1272 PLF MASTER PLAN REVISION SIMPSON MTS12 < 1000 > 14-1 Od x 1 1/2 g-3 42" 8F8-1 B/1 T 3166 PLF 2165 PLF USE SIMPSON MTS12 FOR ALL TRUSS TO FRAME CONNECTIONS (U.N.O.) 2-3-19 B-4 90" 8F8-1 B/1 T 1029 PLF 959 PLF B-5 54" 8F16-1 B/1 T 6039 PLF 2507 PLF B-6 70" 8F16-1 B/1 T 1459 PLF 1272 PLF B-7 112" 8F16-1B/1T 1818 PLF 980 PLF Fes• '� �• B-8 64" 8F16-1 B/1 T 5365 PLF 2290 PLF O ~ � co o B-5 g-5 _ B-9 112" 8F16-1 B/1 T 1843 PLF 1133 PLF B-10 208" 8F16-1 8/2T 950 PLF 500 PLF ram, O n q q � o 8' FL CLG. COFFER I I I :. •• .r. . (2) HETA20 GLG. L (2) HETA20 W 8F8-1B 8F16-111 #5 REBAR AT TOP '�j c 1'T---- W (2) HETA20 TYPE DESIGNATION MIN. (1) REQ D F = FILLED WITH GROUT / U = UNFILLED raj ' :• 1-iiz• CLEAR W o � OH 8' FLAT I I — ` ` — ` QUANTITY OF #5 REBAR AT ¢ = C.M.U.F n O CLG. L — — — — — — — — — J rBOTTOM ❑F LINTEL CAVITY Cfl 8F16-1B/1T 0) � o !� —GROUT C� �o #5 REBAR AT BOTTOM N❑MINAL WIDTH LQUANTITY OF #5 '" ❑F LINTEL CAVITY I I I B-5 NOMINAL HEIGHT REBAR AT TOP L7-5i8•acrua 8' NOMINAL WIDTH ( B-8 I I 8' FLAT I CLG. Lo Lo rn �— N W N ui ui J M VAULTED c Q LL. N CLG. FRAMING NOTES. B-5 om: LL _jM0CC) �� I I 1. DESIGN LOADS: _j ~ I I WIND: 160 M.P.H. AT 3 SECOND BURST ILL 04 ROOF: 37 PSF (20 L.L./17 D.L.) m W cp C� � 0 cm 2. #2 OR BETTER 2x4 BLOCKING AT 4'-0" O.C. Q WITH 2 EA. 16d TOE NAILED EACH SIDE Z O Lu(DIAPHRAM AREA w U Ill Z VAULTED CLG. 3• AT BLOCK/STRUCTURAL FRAME WALL N O CONNECTION, PROVIDE 1/2" DIA. COUNTERSUNK M 0- CATHEDRAL ANCHOR BOLTS W/ 2-1/4" MIN. EMBED. 0 24" J CLG. O.C. VERT 0 (2)2x4 P.T. VERT. W H 8' FLAT 4. SEE FRAMING PLAN FOR PRECAST LINTELS CLG. TYPICAL 5. PERMANENT OR TEMPORARY BRACING OF TRUSSES PER HIB91. ANY ADDITIONAL TRUSS PROJECT BRACING REQUIRED WILL BE DETERMINED BY TRUSS ENGINEER ON SIGNED AND SEALED NO 17-015-001 TRUSS DIAGRAMS. B-3 I I I 8' FLAT VAULTED 8' FLAT DATE DRAWN 3-22-20 CLG. CLG. CLG. 6. ALL HEIGHTS NOTED ON PLANS ARE DRAWN BY MCA MEASURED FROM TOP OF FINISH FLOOR (REF. ELEV. 0'-0") CAYMAN 1560 B1 _(L)2x3 H 7. ALL TRUSS TO TRUSS CONNECTORS TO BE OH 22"x54" 11-4" SUPPLIED BY TRUSS MANUFACTURER. LIVING 1560 SQFT >< ATTIC ACCESS OH 8. SEE STRUCTURAL NOTES FOR ADDITIONAL INFORMATION. GARAGE 372 SQFT 8' FLAT 2X4 ®16"O.C. CLG. KNEEWALL TOP ® 9. OVERHANG IS 1'-4" UNLESS NOTED OTHERWISE LANAI 144 SQFT 11 -4 A.F.F. ENTRY 86 SQFT (2) HETA20 (2) HETA20 TRUSS GIRDER I I II TOTAL 2162 SQFT I CUBIC VOLUME OF — MICHAEL C. ANDERSON CONDITIONED SPACE (11 H O H _ 12,480 CUBIC FEET .— O ;F� — — SHEET Trom: Io FRAMING PLAN -= - MICHAEL C. ANDERSON, ARCHITECT OF RECORD A --•- �'' g_2 P.G. HDR. g_1 FL. LIC. AR0017305 BOT. +6'-8" 2x4 "X" BRACING TYP. 1/4" = 1'-0" AFF 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953if,:-__„-" A 4mO (772)418-2118 �� 2x4 BOTTOM CHORD BLOCKING TYP.-SEE PLANS DESIGNED TO MEET THE REQUIREMENTS OF NOTE #2 THE 2017 FLORIDA BUILDING CODE-RESIDENTIAL (6TH EDITION) FL. LIC. AR0017305 PLAN REVIEW REVISIONS LEGEND -0- SURFACE MTD, CEILING FIXTURE 4- PENDANT FIXTURE MASTER PLAN REVISION RECESSED LIGHT 3 #1 CU TH H N OR K> WALL MTD. BRACKET @ 72' A.F.F. 2-3-19 AL. EQUIVALENTS FLUORESCENT FIXTURE 2" CONDUIT WALL MTD. VANITY LIGHT ELECTRICAL LOAD CALCULATION 150 ® EXHAUST FAN r, 30 CKT0 1560 S.F. AT 3 VA 4.7 kVA PANEL - EXHAUST FAN W/ LIGHT 2 SMALL APPLICANCE CIRCUITS 1500 VA EACH 3.0 kVA LAUNDRY CIRCUIT 1.5 kVA METER V EXTERIOR FLOODLIGHTS w RANGE 12.0 kVA 150 1 WATER HEATER 3.0 kVA /� CEILING PADDLE FAN DISHWASHER 1.5 kVA M . C. B• (PREWIRE OR W/ LIGHT AS NOTED) DISP❑SAL 1.5 kVA rTl ^ n q q DRYER 5.0 kVA �SUBTOTAL 32.2 kVA "q`I O WALL MTD, SMOKE DETECTOR f1> — — — — � CEILING MTD, SMOKE DETECTOR o — — — _ — — j FIRST 10 kVA AT loox 10.00 kVA 2" RIGID O.H. SERVICE F.P.L. �-4 I REMAINDER AT 40% 8.9 kVA O• CEILING MTD, CARBON MONOXIDE DETECTOR W PREWIRE ( TOTAL OF OTHER LOAD 18.9 kVA I I I 10 kVA OF AC AT 40% 4.00 kVA -� CHIMES ( I PREWIRE I ( I — — — — { TOTAL 22.9 kVA -[•] 'y I \ I I N 0. 4 C U. WI R E--� CHIMES PUSH BUTTON o I I I 22,900 VA DIVIDED BY 240 V 95.4 A TO U FER GRN D. w ��, � — — — — I WP POOL SUB PANEL 30.0 A / TELEPHONE JACK ,� M \ I GFI ( �I "`I I \ I TOTAL 125.4 A TV CABLE TELEVISION JACK rTl ~ I +5 A.F.F. \ I S p USE 15 0 AMP SERVICE 110 V. DUPLEX RECEPTACLE "ti o - - -�- J O SCHEMATIC ELECTRICAL RISER L - - - • f.._........_.._.. ..._ ._......_.;...................._...j.................. 1/2 SWITCHED 110 V. DUPLEX RECEPTACLE .......... I _____..._..___...!...__.___.__..____ i...____.._._. ...._.____...-____.__._ _...__.__ <...___. _ _� _ ACK TO BACK SERVIC g E 110 V GFI DUPLEX RECEPTACLE o O 0 220 V. RECEPTACLE C.M D. S.D. 3 t DEDICATED 220 V. OUTLET I E i I 110 V JUNCTION BOX .................s......_........_.a.........................?..... ................. 3 i 42' A.F.F.F SWITCH @ RHEOSTAT SWITCH @ 42' A.F.F. tLo ELECTRICAL NOTES GFI C=______= TP� TOUCH PAD FOR SECURITY SYSTEM 'r N I o O co __. i I I f l 1 GFI 1. ALL BEDROOMS SHALL HAVE AFCI CIRCUIT PROTECTION O CENTRAL VACUUM OUTLET LOCATION Ill cV EXH. I I I ``'� i l UNLESS NOTED OTHERWISE. m � PRE IRE II E FAN...._ ...... 1 i y±" ...................... .......... SHALL BE D H E ELECTRICAL DISCONNECT W J M SP.N.I .....W.. �. =ENI GFI 2 ALL COUNTERTOP KITCHEN AN BAT ROOM OUTL TS DISP. GFI CIRCUIT PROTECTION UNLESS NOTED OTHERWISE. o U) Q o 1 I I .....__..._.._ _ _.___._.. ac�rs CAT6 OUTLET W Of 0 n LL N I I _ 1 3. ALL EXTERIOR OUTLETS SHALL BE WATER PROOF GFI z W — O CIRCUIT PROTECTION UNLESS NOTED OTHERWISE. LL OUTLET FOR - � -� 0 � CN +5' A.F.F. I I I i J MICROWAVE _� m pJ I I 4. PROVIDE DISCONNECTS AT ALL APPLIANCES AND OTHER Z) Z IL EQUIPMENT TV 1 / I 11 a - ^h EQUIPMENT AS REQUIRED BY N.E.C. m Q o)W co U ___ _-1 _. . U N U PREWIRE -- FI _ TV I GFI 5. IF NE BRANCH CIRCUITS ARE ADDED: .............._......i..._...................................... ..>.._..............._........._.................._. A) ALL 120V, SINGLE PHASE, 15 & 20 A BRANCH CIRCUITS W W ~ \ SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY U) Z ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, to DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, 04 +5 A.F.F. / / I S.D HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED M d BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER COMBINATION / TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH J W S.D. I ? CIRCUIT (NEC 210.12 (B)). F- ................. W. B) TAMPER RESISTANT RECEPTACLES (NEC 406.11) ARE / I REQUIRED IN DWELLING UNITS IN ALL AREAS AS SPECIFIED IN D ........... 2008 NEC 210.52, ALL 125V, 15 & 20A RECEPTACLES. i IS p• 6. SMOKE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH 3 A MANNER THAT THE ACTUATION OF ONE ALARM WILL _....__...._... ACTIVATE ALL THE ALARMS. PHYSICAL INTERCONNECTION OF ......_ _�-_ _ __k_____ __ PROJECT � E E o SMOKE ALARMS SHALL NOT BE REQUIRED WHERE LISTED { WIRELESS ALARMS ARE INSTALLED AND ALL ALARMS SOUND E � GFI UPON ACTIVATION OF ONE ALARM. GFI NO, 17-015-001 E � EXH. � f � \ / 7. SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM FAN I DISC. THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A DATE DRAWN 3-22-20 ..... ...::-. -.....__ Y POWER IS _ ( / COMMERCIAL SOURCE AND, WHERE PRIMARY DRAWN BY MCA "" € INTERRUPTED, SHALL RECEIVE POWER FROM A BATTERY. 2FI S D / WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING - _-..-. �(�- WITCH OTHER THAN THOSE REQUIRED FOR OVERCURRENT CAYMAN 1560 B1 _._.__. _ ......_.._ -�._.._...... YYY _...E _.... DISC. �....... .... _ PROTECTION. — — — — C.M.D. \ �' ! EXTENT OF AREA i 22"x54" ACi i FOR VINYL OR TILE NOTE: ELECTRICAL PLAN IS SCHEMATIC. ELECTRICIAN SHALL LIVING 1560 SQFT I • / x ATTIC ACCESS COND -...... PER CONTRACT VERIFY THAT ALL ELECTRICAL INSTALLATIONS MEET APPLICABLE VERSION OF NATIONAL ELECTRICAL CODE AND W/ PULL CHAIN 2017 F.B.C. GFI LIGHT ABV. GARAGE 372 SQFT GFI GARAGE DOOR ELEC. I LANAI 144 SQFT OPENER PREWIRE PANEL / S.D. • - _ - - - - - METER ENTRY 86 SQFT � 1 / I Tv I I TOTAL 2162 SQFT PREWIRE � CUBIC VOLUME OF i I MICHAEL C. ANDERSON CONDITIONED SPACE _ CATS - - - - - _, _ 12,480 CUBIC FEET I I _ .......__..........--.... ....._.__........ F _� � r COACH LTS. SHEET _ — � �P � PREWIRE COACH LTS. ELECTRICAL PLAN MICHAEL C. ANDERSON, ARCHITECT OF RECORD PREWIRE _ / FL. LIC. AR0017305 �_ A 5m0 1 4 = 1 -0 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 �,��^_ _ ;����= (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE-RESIDENTIAL (6TH EDITION) FL. LIC. AR0017305 NOTE: ROOF UNDERLAYMENT SHALL COMPLY WITH SECTION PLAN REVIEW REVISIONS R905 OF THE 2017 FLORIDA BUILDING CODE (6TH EDITION) 2 ARCHITECTURAL FIBERGLASS SHINGLES OVER ____ ----- STRUCTURAL NOTES: WOOD STRUCTURAL NOTES: PER 30# FELT ON 15/32" CDX PLYWOOD SHEATHING ELEV. AND PRE-ENGINEERED WOOD ROOF II 1. WIND LOAD REQUIREMENTS AT 160 MPH PEAK WIND GUST FOR 1. ALL WOOD TO BE SPECIES, GROUP, AND GRADE AS SHOWN TRUSSES AT 24" O.C. (SEE ROOF'NAILING II LINTEL 3 SEC. BURST PER FBCR 2017 (6TH EDITION). ON DETAILS. DAMAGED WOOD NOT TO BE USED. GRUP 11PINE 2. PATTERN DETAIL) II2x4 STUDS 2. WINDOWS, DOORS, AND GARAGE DOORS SHALL BE DESIGNED TO 2 Fb=1 00 p I, 11,OOUOOORPSI, M CO.W19% MAX.,TYP. MASTER PLAN REVISION HURR. STRAP 0 EACH TRUSS II PER PLANS 0 SPACING �J THE 2017 FLORIDA BUILDING CODE. PINE GROUP III WOOD IS DOUGLAS FIR-LARCH, SOUTHERN YELLOW REFER TO CONNECTOR SCHED. 3. ALL FLOOR SLABS TO BE OF 2500 PSI CONCRETE PLANT MIX PINE, HEM-FIR, OR SPRUCE-PINE-FIR. 2-3-19 TYP. O.H. I o 4" THICK WITH FIBER MESH AND/OR 6 X 6-10/10 W.W.M. W/ MIN. 3. ROOF TRUSSES TO BE SET WITHIN 5" OF STUD LOCATED BELOW. R-30 INSULATION PER ROOF PLAN I VERTICAL FILLED CELL n 1 COVER ON 6 MIL POLY VAPOR BARRIER OVER I W/ 1-#5 BAR COMPACTED CLEAN FILL. 4. END JOINTS IN STRUCTURAL DOUBLE TOP PLATE SHALL BE I (2) 16d 4. FIBER MESH REINFORCEMENT: FIBERS SHALL BE 1/2" TO 3/4" OFFSET AT LEAST 4'. STRUCTURAL DOUBLE PLATES TO BE ® 12" O.C. -�� COLLATED POLYPROPYLENE FIBERS. REQUIRED DOSAGE RATE NAILED AT 6" O.C. MAX. 'y Y y Y y y _ -- -TOP_OF_BLOCK I CONC. BLOCK WALL SHALL BE AS SPECIFIED BY THE MANUFACTURER. FIBERS SHALL 5. EXT. SHEATHING ON WALLS TO BE MIN. 15/32" T REFER TO EXT. ELEV. I BE USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S CDX PLYWOOD. WALL NAIL PATTERN TO BE 6" O.C. • (2)2x4 P.T. W/1/2 DIA. {2) 1od RECOMMENDATIONS AND WITHIN TIME AS SPECIFIED IN "ASTM C94". W/ 10d NAILS UNLESS OTHERWISE NOTED. W 1 j2" CLG. GYP. BD. COUNTERSUNK BOLTS ® 6" O.C. THE FIBERS SHALL COMPLY WITH ASTM DESIGNATION C1116 8"x8" U-BLOCK TIE-BM. FILLED ® 24"��O.C. VERT " TYPE 111 4.1.3 AND WITH APPLICABLE BUILDING CODES. 6. ALL STRUCTURAL LUMBER (EXCLUDING PREENG. WD. TRUSSES) W/ CONC. & (1) #5 REBAR CONT. ALUM. FASCIA AND 2 1/4 MIN EMBEDMENT 3 1/4 CERTIFICATION OF COMPLIANCE SHALL BE MADE AVAILABLE TO BE #2 OR BETTER GROUP II, UNLESS OTHERWISE NOTED. 0 ~ DRIP EDGE UNLESS II WITH 2" SQUARE X 1/8" ON REQUEST. STANDARD ACI 302 PROCEDURES FOR PLACING, 7. STRUCTURAL HEADER SIZES SHOWN ON ROOF FRAMING PLAN W � PRE-ENG'RED PRECAST LINTEL OTHERWISE NOTED II THICK HURRICANE WASHER FINISHING, AND CURING SHALL BE FOLLOWED WHEN USING ARE TO BE #2 OR BETTER, SPECIES GROUP II r, �n '�i SEE SHEET A 4.0 FOR DETAILS ON EXT. ELEV. II DETAIL AT FIBER MESH CONCRETE. 8. MAX. 1" HOLE DRILLED INTO EXTERIOR STRUCTURAL STUDS. CONT. ALUM. II 90° CORNER 5. CONCRETE MASONRY UNITS SHALL MEET ASTM C90. 9, STUDS TO BE DOUBLED AT EACH END OF SHEARWALL VENTED SOFFIT II TOP OF SLAB 6. MORTAR TO BE TYPE 'M' OR 'S': GROUT TO BE 3000 PSI AS PER DRAWINGS. NOTE: 1x4 P.T. • WDW. HDR HT. I AT 28 DAYS. FOLLOW GROUT CONFINEMENT PROCEDURES 10. WHEN ANCHORING (2) WOOD ITEMS TOGETHER, THE LENGTH O SCREWS FOR DRYWALL ON WALLS: PER PLANS L AS DEFINED IN ACI 53-99. f'm = 1500 psi OF HURRICANE STRAP MUST BE EQUALLY HALF ON EA. ITEM. MAX. EDGE SPACING: 7" PLOYCEL SEALANT MAX. FIELD SPACING: 16" RAISED CEMENTITIOUS EXTERIOR FRAME WALL TO 8. REBAR TO BE SIZE #5 GRADE 40 CONT. 11. NAIL PATTERNS: SCREWS FOR DRYWALL ON CEILING: P.T. WOOD BUCK TRIM PER ELEV. TOP OF FILL CELLS AND -DOUBLE PLATE AT 12" O.C. OUTSIDE THE MAX. EDGE SPACING: 7 PER PLANS CON C. B LOCK WALL CONNECTION CHANGES OF DIRECTION WITH MINIMUM LAP OF 30". SPLICE ZONE (SEE NOTE #4). MAX. FIELD SPACING: 12 -DOUBLE STUD NAIL PATTERN AT 12" O.C.ALUMINUM WINDOW (REFER TO 9. OMIT -DOUBLE HEADER NAIL PATTERN AT 6" O.C. AT FLOOR PLAN FOR SCHEDULE) EA. EDGE, 12" O.C. INTERNALLY. r Q 10. UPLIFT CONNECTORS TO PROVIDE CONTINUITY FROM ROOF -HEADER TO STUD- 4" O.C. EA. HEADER MEMBER W MARBLE SILL TRUSSES THRU PLATES TO SLAB AND FOUNDATION PER -STUD TO TOP OR BOTTOM PLATE- (2)16d END RAISED CEMENTITIOUS ENCLOSED DETAILS. NAILED OR (2)16d TOE NAILED EA. SIDE TRIM PER ELEV. 11. EPDXY ANCHOR ALTERNATE: -ALL INTERIOR HEADERS TO BE (2) 2x \ O n 1/2" DRYWALL ON 1x2 P.T. PER PLANS THREADED ANCHOR ROD MAY BE USED IN LIEU OF ANCHOR WITH 1/2" FLITCH GLUED AND NAILED W "y FURRING ® 16" O.C. BOLTS FOR USE AS PLATE ANCHORS OR HURRICANE ANCHORS. WITH 16d AT 8" O.C. STAGGERED. Q) R-4.2 FOIL INSULATION W/ THE FOLLOWING CRITERIA MUST BE MET: n 4 MIL VAPOR BARRIER CEMENTTIOUS COATING OVER ANCHOR SIZE CONC. HOLE SIZE 12. ROOF SHEATHING TO BE MIN. 15/32" CDX 0 8x8x16 CONC. BLOCK 1/2" 3/4" MIN. HOLE DEPTH PLWOOD NAILED PER ROOF NAILING PATTERN 4" 2500 PSI CONC. SLAB W/ WD. BASE 5/8" 7/8" 6„ DIAGRAM. O FIBER MESH ON 6 MIL. POLY " �. VAPOR BARRIER OVER TERMITE 1-#5 VERT. BAR TIED INTO 8" 13. ALL NAILING SPECIFIED TO BE APPLIED BY NAIL GUN N # 7/8" 1 1/8" AND/OR MANUALY. TREATED CLEAN FILL COMPACTED 4 #5 BAR DOWEL W/ STD HOOK AFTER HOLE IS DRILLED ALL CONCRETE DUST MUST BE RKOVED DE A MINIMUM DENSITY OF 95% AS AND RUNNING INTO LINTEL PRIOR TO EPDXY INSTALLATION. THREADED ROD (MIN. A36 14. TRUSS BRACING PER TRUSS MFG. DRAWINGS. DETERMINED BY ASTM D-1557 I (LOCATIONS PER FDTN. PLAN) STEEL) AND REBAR TO BE FREE OF DIRT OR GREASE. LOAD ON _ 0'-0" - ROD OR REBAR CANNOT OR BE APPLIED UNTIL 12 HOURS AFTER 15. AT ALL INTERIOR WALLS THAT ARE NOT LOAD BEARING, APPLICATION. TWO COMPONENT EPDXY RESIN MATERIAL TO BE METAL STUDS MAY BE SUBSTITUTED FOR WOOD STUDS. TOP OF SLAB MIXED PER MFG. DIRECTIONS. - 12. MISSING DOWEL PLACEMENT: 16. ANCHOR BOLTS 8" LONG x 1/2" DIA. WITH A 2" _) FINAL GRADE SQUARE X 1/8" THICK HURRICANE WASHER EMBEDDED 5" Lo I NEW HOLE SHALL BE DRILLED 7/8" TO 1" WIDE AND 10" DEEP. UNLESS NOTED OTHERWISE. Lo III STUCCO STOP AS REQ'D. AFTER HOLE IS DRILLED ALL CONCRETE DUST MUST BE REMOVED PER LOCAL BLDG. DEPT. PRIOR TO EPDXY INSTALLATION. THREADED ROD (MIN. A36 17. ALL EXTERIOR CEILING MATERIAL TO BE 1/2" MIN. EXTERIOR c1li III _ STEEL) AND REBAR TO BE FREE OF DIRT OR GREASE. LOAD ON GRADE GYP. BOARD OR 1/2" MIN. SOFFIT BOARD UNLESS NOTED C>Ir- -jo CONC. FTG. PER ROD OR REBAR CANNOT OR BE APPLIED UNTIL 12 HOURS AFTER w CV FOUNDATION PLAN APPLICATION. TWO COMPONENT EPDXY RESIN MATERIAL TO BE U 1- Mco IXED PER MFG. DIRECTIONS. ALL PLANS, DETAILS, AND NOTES ON THESE o M III III III TYP. EXT. BLOCK WA DRAWING ARE PROPRIETARY AND CANNOT BE _ c 0 Q LL 00 N WALL USED, TRANSFERED, OR OTHERWISE REPRODUCED Z w > � o � WITHOUT THE APPROVAL OF RENAR HOMES LL O c N � 0 Z ILL N U � WF_ ccgQ ZO0 Ill LLJ U) Z 0 5 N 0, O z 3/4" DIA. X 6" DEEP HOLE FOR M d w #5 BAR SET IN EPDXY ADHESIVE w %,D O ROOF EDGE 20 I Ij TOP OF BLOCK WALL - - - - - - - - - - - - - - - � F- GROUT OP OF CELL AT 'I ( ,S/ O O I O ROOF II I '� I EDGE SAWCUT APPROX. 4"W. X 24"H. - - - - - - - - - - - - - - OPENING IN WALL I�I 25" MIN. LAP OF REBARS I 4' PROJECT II O I O lO RIDGE I � I I 2 2 O I � NO. 17-015-001 3,000 PSI CONCRETE FILLED CELL I -W/ #5 BAR - - - - - - I DATE DRAWN 3-22-20 - - s REINFORCED/FILLED I CONC. BLOCK CELL I ��Q 1 1 `<< 1 O I 3 DRAWN BY MCA I 0 � - - � F I O _ - -� - - - - - - - � CAYMAN 1560B1 ALCOA TRADITIONAL "F" CHANNEL W/ 1/2" DIA L-BOLT SAWCUT 1"W. OPENING IN WALL 2 JP�' 3 3 `n O LIVING 1560 SQFT 5/8" CASEHARD "STUB" OR "T" NAILS (8" LONG) W/ 2" I FROM TOP TO BOTTOM FOR FULL O O ® 10" O.C. IN CONC. BLOCK. OR WITH WASHER AT HEIGHT REBAR PLACEMENT INTO O PRE-ENGINEERED 8d NAILS ® 10" O.C. IN WOOD 32" O.C. MAX. 2x6 P.T. CELL - FILL SOLID W. CONCRETE ROOF TRUSS ` JAMB DETAIL OZONE 1-USE 8d RING SHANK NAILS ® 6" O.C. - GARAGE 372 SQFT SAWCUT APPROX. 4"W. X 24"H. I 2X2 NAILED TO EVERY OPENING IN WALL ' ZONE 3 USE 8d RING SHANK NAILS O ZONE 2-USE 8d RING SHANK NAILS O OTHER TRUSS TAIL W/ 2x4 P.T. W/ CONC. 2x6 P.T. FROM BOT. OF I ® 6" O.C. ® 4" O.C. LANAI 144 SQFT (2)-10d NAILS NAILS AT 12" O.C. HDR. TO CLG. LINE CONCRETE 'I „U" BLOCK U r 25" MIN. LAP OF REBARS I' TOP OF SLAB NAILING PATTERN FOR ROOF II TIE-BEAM TOP COURSE ENTRY 86 SQFT ROOF SHAPE REPRESENTS TYPICAL ZONES ONLY. HORIZ. 2X2 NAILED TO 2x6 EQUAL EQUAL m 3/4" DIA. X 6" DEEP HOLE FOR TOTAL 2162 SQFT VERT. 2X2 S W/ (2)-10d P.T. 1/2" DIA L-BOLT 2x6 w #5 BAR SET IN EPDXY ADHESIVE NAILS N ALUM. NAILS 0.12 DIA. (8" LONG) W/ 2" P.T. 10 CUBIC VOLUME OF SEE PL N SHANK 3/8" DIA HEAD WASHER_ 32 O.C. MAX. ADDED R E I N F. FILLED MICHAEL C. ANDERSON CONDITIONED SPACE _ 1-1/2 LONG ® 6 O.C. M GARAGE DOOR BLOCK CELL DETAIL ,�.,-��,���-._ 12,480 CUBIC FEET ALUM. NAILS 0.12 DIA. SHANK OPENING " _ 3/8" DIA HEAD 1-1/2" LONG - N NOTES: (2) PER SOFFIT SEGMENT .- -DRILLED HOLE TO BE CLEANED PRIOR TO DISPENSING ADHESIVE _ SHEET SOFFIT DETAIL ALUM�NUM SOFFIOTN#V-44 VENTEDAL ELEVATION --EPDXY ADHESIVE TO REBAR DOWEL 0 BE BE HIGHEAN ST OIL TH T PE N.T.S. ff It r - MICHAEL C. ANDERSON, ARCHITECT OF RECORD GARAGE DOOR DETAIL FL. LIC. AR0017305A 6mO 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE-RESIDENTIAL (6TH EDITION) FL. UC. AR0017305 PLAN REVIEW REVISIONS MASTER PLAN REVISION SEE PLAN 2-3-19 2x8 RIDGE BOARD CEMENTITIOUS COATING ON 2x6 RAFTERS AT 24" O.C. OR WOOD MASONRY FRAMING MAX. - TOE-NAIL TO RIDGE I I LATH OVER 2 LAYERS 15# BD. W/ (2) 10d NAILS FELT OVER 7/16" OSB ROOF MORTAR JOINTS INSTALL SIMPSON HTSM16 ® 4' 0" O.C. (PLACE OVER GABLE END TRUSS 2x4 — RT. STUDS SHEATHING 1/4" TO 3/8" w I W/ (8) 10d NAILS TO TRUSS ATTACH I GALV. METAL ABOVE TRUSS BELOW) (TYPICAL) STRAP TO LINTEL W/ (4) 1/4" x 2-1/4" I FLASHING SIMPSON STRONG—TIE I PANEL ~, MIN TAPCONS VERIFY NUMBER OF TAPCONS I 2X4'S @ 16" O.C. 'H2.5' OR 'LSTA18' L___ _- -_ -_-J ANCHORS R co WITH CONNECTOR SCHEDULE (4) 10d NAILS 12 AT EA. END OF 2x4 ° s FIBERGLASS SHINGLES PRE-ENG'RED SEE VERT. STUD PRE-ENGINEERED ° OVER 15 FELT ON TRUSSES Z # NOTE #4 J 8" X 8" X 4" Q� ROOF TRUSS L PROVIDE 2X4 BLKG 7/16" OSB W (NOMINAL SIZE) W OQ, q q @ 16 O.C. BEHIND (3) 10d NAILS NOTES: SEE N I GLASS BLOCK UNITS q O GABLE END TRUSS HURRICANE CONNECTORS REQ'D NOTE #4 L_________ ___ ________J 1. _ _TOP OF BLOCK AT 8'-0" O.C. ROOF ~ \ 0 ° PER PLAN 2. PROVIDE H2.5 OR LSTA18 � ----�— rr n " n AT EACH RAFTER END SHEATHING 8" X 8" X 16" -- 3. PROVIDE 2x8 RIDGE BOARD PANEL ANCHORS & CONCRETE LINTEL 2X FASCIA WHEN APPLICABLE REINFORCEMENT I I � W BLOCK FILL WITH 4. PROVIDE 2x4 VALLEY BLOCKING BTWN. TRUSSES EVERY OTHER W/ DRIP EDGE L__ __ __ ___J CONCRETE AND �, ;� AT LOCATIONS WHERE VALLEY FRAMING DOES --- ------ -- COURSE OR 16 O.C. (1) #5 BAR 2X4'S @ 16" O.C. NOT BEAR ABOVE TRUSS WHICHEVER IS LESS I-T, P.T. 2X4 LEDGER BD. HAND FRAMED VALLEY DETAIL EXPANSION W/ 1/4" DIA. TAPCONS 1/2" EXT. GYP. BD. THIS DETAIL APPLIES ONLY WHEN AN INDIVIDUAL 2x6 RAFTER STRIP & SEALANT (2-3/4" MIN. HORIZONTAL SPAN IS GREATER THAN 8'-0" EMBEDMENT) SPACED 2,_Or, SIMPSON HUS24 HEAD j C)OCA11ONS ASPHALT EMULSION \ ALTERNATE TRUSS ANCHOR DETAIL 16" O.C. @EACH JOIST/ (ONLYTHIN MORTAR ® � � LEDGER BD. CONN. SILL LOCATION [� N.T.S. R❑❑F A T SLIDING SPECIFICATIONS GLASS D❑❑R DETAIL-1 STORY GLASS BLOCK UNITS: 8" X 8" X 4" (NOMINAL SIZE) 0 MORTAR: TYPE "S" PER ASTM C 270. REINFORCEMENT: LADDER TYPE, 9-GAUGE, 2" WIDE WITH BUTT-WELDED CROSS WIRES AT 16" O.C., HOTT DIPPED GALVANIZED. PANEL ANCHORS: 20 GAUGE PERFORATED STRIPS, 24" X 1 3/4", HOT-DIPPED GALVANIZED, AT BOTH JAMB AND HEAD LOCATIONS ANCHORED WITH #10 X 1 1/4" LONG PANHEAD SCREWS WITH #10 WASHERS (2 PER PANEL ANCHOR) OR (1)3/16" X 1 1/4" HILTI KWIK BOLT II. " EXPANSION MATERIAL: 3/8" THICK POLYETHYLENE TYPE. Lo EL: 36 ABOVE LINTEL BLOCK TOP COURSE SEALANT: SILICONE TYPE. Vn ADJACENT FLOOR rn FILLED W/ CONC. & 1-#5 BA TOP OF HIGHER c i BLOCK WALL GLASS B LOCK INSTALLATION co 5x5xj" WELDED Z Z _— _F - w to04 FLANGE o Z w I #5 BAR DOWEL N TOP OF LOWER a= I W/ STD. 90° HOOK MLL N Z W > � o BLOCK WALL II 04 1 " --_ _____ -= II CONC. BLOCK WALL _j m p co N Ii 1" 1" 3" 0 x 1/4" STEEL PIPE #5 BAR DOWEL VERTICAL FILLED m W F CD 0 " TAPCON W/ STD. 90' HOOK it CELL W/ 1-#5 BAR Q U O < �i U ti M TYP.4 II wc W 5x5x j" WELDED II In N co ZO 1 " FLANGE BLOCK WALL HEIGHT M a 5" TRANSITION DETAIL ❑ SHEATHING J � ❑VER WOOD TRUSSES Lu BOLLARD DETAIL I STUCCO FINISH ON USE SIX GALVANIZED 11 OR 12 GAUGE ROOFING NAILS METAL LATH WITH HEADS AT LEAST 3/8" IN DIAMETER. ALL NAILS MUST BE DRIVEN FLUSH WITH THE SHINGLE SURFACE AND PENETRATE BOND BREAK THROUGH THE WOOD DECK BY AT LEAST 1/8" PROJECT PLACE NAILS 6-1/8" FROM BOTTOM EDGE OF EACH SHINGLE FELT LAYERS 15# AND 1"ALL NAILS FROM EACH BE PLACEDON 6 61/8" NAIL NAILS LINEFELT NO. 17-015-001 I DATE DRAWN 3-22-20 I MEMBRANE BRIDGE DRAWN BY MCA FLASHING 1" 1'-0" 1'-o" 1" CAYMAN 1560 B1 I LIVING 1560 SQFT FLASHING / CONTROL + + + + + + + + + + + JOINT + + + + + + + + + + + GARAGE 372 SQFT + + + + + + + + + + + + + + + + + + + + + + + + + + + + LANAI 144 SQFT ENTRY 86 SQFT STUCCO FINISH ON BLOCK SHINGLE SIDE VIEW TOTAL 2162 SQFT CUBIC LUME OF SHINGLE NAILING DETAIL MICHAEL C. ANDERSON CONDITIO ED SPACE _ FLASHING DETAIL AT R❑❑F HIGH WIND OR STEEP SLOPE N.T.S. 12,480 CUBIC FEET -r^- FRAMING ON MASONRY SHEET MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 �`,�� �ti�= 6ml (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE-RESIDENTIAL (6TH EDITION) FL. LIC. AR0017305 PLAN REVIEW REVISIONS ROOF SHEATHING TOE NAIL (2) 16d EACH SIDE " 2x4 BLKG. ® 48" O.C. �— 2x4 BLKG. ® 48 O.C. MASTER PLAN REVISION 2-3-19 ALUMINUM DRIP EDGE AND FASCIA PRE-ENG. TRUSSES (2) 16d COMMON NAILS AT ® 24" O.C. FIN EA. 2X4 LADDER FRAMING CORNER — WINDOW TOP _ 2x4 45' CROSS BRACING _ _ _ . GABLE END TRUSS AT TRUSS MID-PT. AND AT CORNER NAILING FIN AIR-INFILTRATION BARRIER 8'-0" O.C. (MAX.) FLASHING TAPE — . — — — — . — — — . OVER EXT. SHEATHING (SEE Q CORNER EXT. ELEV. FOR FINISH MAT'L.) W -.-I- FLASHING �/� r,, cyD TAPE - 1 v TOP TRUSS SETBACK FLASHING PER FRMG. PLAN TAPE 2x4 TRUSS BOTTOM SIDE CHORD BLKG. AT ^�I FLASHING 12 ROOF TAPE SHEATHING PER 4'-0" O.C. REFER TO \ 0 ELEV. FRAMING PLAN SIDE CHECKRAIL HURRICANE STRAP FLASHING — _ — _ — _ - _ _ - ® EACH TRUSS PER (2) 16d COMMONSTAPE FRMG. PLAN TOE NAILED EA. SIDE WINDOW BOTTOM W SILL FLASHING TAPE #1 � Q� N � SILL FLASHING TAPE #2 r^ 1. CUT THE WATER RESITIVE BARRIER (1C) II ATER RESISTIVE BARRIER, WATER RESITIVE BARRIER • I co R' _�-1 ST CUT '� SHEATHING I r, "`I O FRAMING 8x8 U-BLOCK TIE-BEAM FILLED !� O I I I I TH CUT, W/ CONC. & (1) #7 BAR CONT. 1 3RD I I MAKE A 6" CUT UP ---- [� n SCUT I FROM EACH TOP I EXTERIOR , VERT. #5 BAR AT EA. REINF. , CORNER AT A 45sb I I ANGLE TO ALLOW THE I I FILLED CELL PER FDTN. PLAN 450 I I WATER BARRIER TO I I ,,,.-TYPI I BE LAPPED OVER THE I I I I <-2ND, I FIN AT THE' I I THE WINDOW HEAD OF I IO1�- c�T -� ; GABLE END SECTION @ HIP ROOF Y- Y -------------J I I I I I 2. FOLD THE WATER RESISTIVE BARRIER (11)). FOLD SIDE AND BOTTOM FLAPS INTO THE I I OPENING AND STAPLE TO INSIDE WALL. FOLD TOP FLAP UP AND TEMPORARILY FASTEN L___ 3. APPLY SILL FLASHING TAPE #1. CUT A PIECE OF FLASHING TAPE 12" LONGER THAN THE 1 Lo Lo OPENING WIDTH. APPLY AT THE BOTTOM OF THE OPENING AS SHOWN (1E) SO IT OVERHANGS 1" TO THE EXTERIOR. 3 04 NOTE: THE TAPE IS CUT 12" LONGER THAN THE WIDTH SO THAT IT WILL EXTEND 6" UP 6 EACH SIDE OF THE OPENING. it TOE NAIL (2) 16d EACH SIDE PLYWD, DECKING J � ti 4. TAB THE SILL FLASHING TAPE AND FOLD. CUT 1" WIDE TABS AT EACH CORNER (X" FROM i y2" J U) M X EACH SIDE OF CORNER) (1F) FOLD TAPE TO THE EXTERIOR AND PRESS FIRMLY TO ADHERE 2x4 TRUSS TOP CHORD 2x4 BLKG. @ 48' D.C. M _ _j Q a� N IT TO THE WATER RESISTIVE BARRIER. BLKG. @ 48' D.C. W u O N 4 Z O J of C) co 5. APPLY SILL FLASHING TAPE #2. CUT A PIECE OF FLASHING TAPE 12" LONGER THAN THE " J CO N OPENING WIDTH. APPLY AT THE BOTTOM, OVERLAPPING TAPE #1 BY AT LEAST 1". DO NOT 1a-f' PRE-ENG. TRUSSES � Z J � ALLOW THE TAPE TO EXTEND PAST THE INTERIOR FACE OF THE FRAMING (1G). NOTE: THE FLASHING MAY NOT FULL COVER THE FRAMING MEMBERS. I AT 24' ❑.C. / lQ � M Q I I 5 / (2) 16d COMMON NAILS AT Q U w cV U EA. 2X4 LADDER FRAMING Lu Z O Q N. 2x4 45° CROSS BRACING / / 1/2' PLYWD. SHEATHING OVER w U Z AT 4'-0' D.C. / / GABLE END TRUSS FASTEN WITH O W/C2)16d NAILS AT EA. / / 8d NAILS AT 6' D.C. ti _ TRUSS WEB MEMBER / // GABLE END TRUSS cM W .J N❑TE, w I EX�RIOR�\ F- 1. APPLY SIDE FLASHING TAPE. CUT TWO PIECES OF FLASHING TAPE 4" LONGER THAN THE FRAME 1 )IE HOLD FACE OF GABLE END HEIGHT OF THE WINDOW. APPLY ONE PIECE TO EACH SIDE OVER THE NAILING FIN AND ONTO THE I I WATER RESITIVE BARRIER. THE TAPE SHOULD EXTEND 2" ABOVE THE TOP OF THE WINDOW AND 2" I 2x4 TRUSS BOTTOM \ TRUSS IN 3/4' BEYOND BLK, BELOW THE BOTTOM OF THE WINDOW. PRESS THE TAPE DOWN FIRMLY. CHORD BLKG. AT FOR CEMENTITI❑US FINISH \ \EX 1 I I 4'-0' D.C. REFER TO \ \ �RIpR�e FRMG. PLAN \ \ )IE HOLD FACE OF GABLE END I I I I \ \ TRUSS OUT 1/4' BEYOND BLK. PROJECT 2. APPLY TOP FLASHING TAPE. CUT A PIECE OF FLASHING I FOR SIDING FINISH TAPE LONG ENOUGH TO GO ACROSS THE TOP OF THE WINDOW I AND EXTEND AT LEAST 1" PAST THE SIDE FLASHING TAPE ON I 2 I I I \ \ SIMPS❑N HETA20 AT EACH TRUSS NO. 17-015-001 BOTH SIDES. APPLY THE TAPE OVER THE TOP NAILING FIN AS 2U 1 I I I CO MM❑NS TOE \ \ VERT WEB MEMBER (24' D.C. MAX) DATE DRAWN 3-22-20 SHOWN. r�1 I I ��� � NAILED EA. SIDE \\ i6d COMMON NAILS NOT DO NOT TAPE OR SEAL THE BOTTOM NAILING FIN. I �� ; 16 6' ❑ T❑ DRAWN BY MCA 1' I _ 3. FOLD DOWN TOP FLAP OF WATER RESISTIVE BARRIER (3C) I I 1 VIEW�� 2x6 P.T. PLATE I I I CAYMAN 1560 B 1 4. APPLY FLASHING TAPE TO DIAGONAL CUTS. CUT PIECES I I EXPANSI❑N J❑INT AT ' I OF FLASHING TAPE AT LEAST 1" LONGER THAN THE DIAGONAL I CEMENTITI❑US FINISH I I I I 8x8 U-BLOCK TIE-BM. FILLED CUTS IN THE WATER RESISTIVE BARRIER. APPLY THE TAPE \`�'��+ 1 3 1 LIVING 1560 SQFTW/ C❑NC. & Cl) #7 BAR C❑NT. COVERING THE ENTIRE DIAGONAL CUT IN THE WATER RESISTIVE I I 2x6 P.T. PLATE BARRIER AT BOTH UPPER CORNERS OF THE WINDOW. I I NOTE: BE SURE TO OVERLAP THE TOP CORNERS (3D) O I I VERT. #5 BAR AT EA. REINF, C❑NT, W/ 5/8' DIA. GARAGE 372 SQFT I I FILLED CELL PER FDN, PLAN ANCHOR BOLTS 1 1 @ 32' D.C. OR W/1/2' LANAI 144 SQFT I DIA. ANCHOR BOLTS \\ I ENTRY 86 SQFT \\�J GABLE END SECTION X-X @ 24 D.C. SCALE; NTS TOTAL 2162 SQFT CUBIC VOLUME OF MICHAEL C. ANDERSON CONDITIONED SPACE _ 12,480 CUBIC FEET SHEET r MICHAEL C. ANDERSON, ARCHITECT OF RECORD =-� `'�`"�• �li`� � FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953A 6m2 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE—RESIDENTIAL (6TH EDITION) FL. LIC. AR0017305 i PLAN REVIEW REVISIONS MASTER PLAN REVISION OPEN TO W3 12 W3 12 2-3-19 FAMILY RM. W3030 ° ° W2430 ° ° OPEN TO BEYOND BEYOND 010 MICRO ° BAR TOP BAR TOP SINK 0 0 ° w � 0 0 0 0 0 0 0 ~► '�' d' ° ° 0 B 14" SB 36 B18 3/4 MICA TOP w q co B1 B24 ON SHIM SCREWED TO SECURE FILLER D W FILLER RNG REF KITCHEN KIT. AT RNG . KIT. AT SINK DW 1X4 TOP PLATE WOOD Q44 TRIM 2x4 STUDS AT 16" O.C. w � ";I (� wow 1 /2" DRYWALL w \ off WALL M TD. LT. O . WALL M TD. LT. KITCHEN BASE CABINET 0 N 0 TE S : MIRROR N CER. .C. TILE MIRROR 1 . BATHROOM TOWEL BARS AT 54" A.F.F. M.C. M.C. 2. BOTTOM OF MEDICINE CABINETS AT / FILLER FILLER 54" A.F.F. LAV LAV LAV rn 3. TOP OF BATHROOM SHOWER TILE O � = o 0 0 ° � � B A R TO P DETAIL � CDTO CEILING HT. o I— _ I r I ZiZ (� , � J ~ � � �■~ > o IVB24 w i - 4. SHOWER HEADS AT 6'-8" A.F.F. > m _ m_ c, c Q u- 00 N W.C. SH WR. VB 42 VB 42 z o J � o N FILLER $:Zu _jco m w � cNn 1p BATH 2 M . BATH VANITY : C0wNU Z O w � ccl) z ti O cM a_ W J W I— PROJECT NO. 17-015-001 DATE DRAWN 3-22-20 DRAWN BY MCA SOAP CAYMAN 1560 B 1 30" v DISH RAD. Q RECESS LIVING 1560 SQFT OPEN co O GARAGE 372 SQFT TO . H ALL CO a- �`- O Q X LANAI 144 SQFT O ENTRY 86 SQFT Sk Q TOTAL 2162 SQFT H A �� ARCH MICHAEL C. ANDERSON CENTER CUBIC VOLUME OF ON WALL CONDITIONED S ACE 12,480 CUBIC FEET TYP . SOAP DISH RECESS LOCATION SHEET MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305A 7mO 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE—RESIDENTIAL (6TH EDITION) FL. LIC. AR0017305 71 40- 7 - - PLAN- REVISION p � i RIVE 4' - MASTER PLAN REVISION 9. -31 NOTE. ALL lUCTWO K R PENETRATING { r w GARAGE COUNG7 SHALL - BE R- 6 IBERGLASS ,DUST WORK. a w COMPLY 1 6 s 4" J oc r �! 1ox10. ( { x m o 6X6 ..7 5Z A 01 411 1 4X1I- 8„ Eje- tf 1 16X16 Sri a ir.!i�X�.�.R� Cooling System`£ - }'Air Source eat PumpAir Source Heat Pump ? s R/A . i H P ' ' t CH14N13036*i)**B* CH14NB031?*0**B* FB4CNP042L CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING _ - � Air Source Heat Pump Air Source Meat Pump 6X6: " : 10X10 _ ,f' `` 4.5 SEER EXH ',8.2 HSPF 1 BM 0 FAN . . , �33,800 Btuh. 34,200 Btuh ICU - n/a . 25,650 Btuh _ LO s` i h: _ n/a 8,550 Btuh /{ n/a .9162515 _ >, C_ N ` ( O Uj to t� y s x H 1I SINK I a DISP `' Q :� ' z,t i Va t(v! CO W LL,. p N W j 12" I I /::3 �. `o 10X10im' ,, _..l 0.,id0 (�1 04 M CD ` i - $ '.➢:: .. - .ci, — H aux,.: em`ac we- r s .. - _ i' -70. 7 i {�k w 0 14" DRYER VENT 10X10 ' THRU WALL. x: x R/A ;f N 24X24 ' 6X6 _ 4„ 1 RHF PROJECT r+ 7M s I a ;. wH w NO. EXH - 17-015120 FAN `` < DATE DRAWN. 12X12 6X6 R. .'�:LINES DRAWN BY MCA R�/A RUN JU �.� � Preferred Air Conditioning & Mechanical, Inc. Q; fFiEAD <: ::�. .: _ 1643 Donna Road west Palm fieach,Florida 33409 CAYMAN 1560 B'J " 9 �` r F:561-689 9 0931 F:Sf:#-478-U(388 831 S Kings HI hway Fort Fierce,Florida " P:772-878-75771 F:772•978-7510 22"x54" LIVING 1560 SQFT x COND CAC 181,7665 I -� TT ACCESS , GARAGE :372 SQFT. 8X8 ; _, � LANAI �50 SQF 1oX1 _ 4 / Q ENTRY 38 SQFT . " TOTAL AN 7- AIR2020 si r CUBIC VOLUME OF MICHAEL C. ANDERSON CONDITIONED SPACE 12,769.4 CUBIC FEET�:`� SHEET H VAC PLAN MICHAEL C. ANDERSON � ARCHITECTOF RECORD a � FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE FL 34.953 �� - �z (772)418-2118 PLANS DESIGNED "f0 MEET THE REQUIREMENTS OF THE,2017 FLORIDA BUILDING CODE--RESIDENTIAL (6TH EDITION) FL. LiC. AR0017305 TRUSS TO NOTE: ALL TRUSS TO WALL AND/OR NOTE: Trusses are designed for SHINGLE material. LEDGER CONNECTIONS BY BUILDER (UNLESS NOTED OTHERWISE) Notify truss manufacturer if material is other than shingle. to 0 NOTE: ALL CEILING DROPS BELOW BEAM ARE 221011 161011 BY BUILDER (UNLESS NOTED OTHERWISE) 6 F— NOTE: THIS TRUSS PLACEMENT DIAGRAM IS TO SHOW U TRUSS I.D. AND TRUSS LOCATION ONLY. C= THE BUILDING DESIGNER IS RESPONSIBLE FOR THE DESIGN OF STRUCTURAL STABILITY OF THE ENTIRE STRUCTURE. P E CD REFER TO THE INDIVIDUAL TRUSS ENGINEERING DRAWINGS M F FOR GRAVITY AND UPLIFT LOADS. FOR BRACING & ERECTION DETAILS REFER N�\ TO BCSI-03 AND/OR ENGINEER OF RECORD ZA al 13 . CD J2 1AREPRESENTS THE LEFT SIDE OF ' 01 EACH TRUSS DRAWING I All 11 �p 0 & 0 t 1� ( NOTE: REFER TO USP CONNECTOR CATALOG FOR INSTALLATION DETAILS ) 00 HANGER BY BUILDER BEAM BY BUILDER A09 CD CM ROO rO8 INDICATED TO BE USED IN C� CONCORDANCE WITH 11101/211 LOADING ROOF FLOOR WIND LOAD 2. 11 All �_ 0. � Cq 05 cm TOTAL LOAD 37 FBC-2017 Cz REV DATE BY REMARKS CD co CD CM ' 00 ` ' ' ' - '