HomeMy WebLinkAboutExtreme 1 Inch Nail Strip1/4/2018
Florida Building Code Online
w+e
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Se
b -r
a
Product Approval
USER: Public User
Product Aoproval Menu > Product or Apelication Search > Application List > Application Detail
FL # FL17022-R7
Application Type Revision
Code Version 2017
Application Status Approved
Comments 08/18/2017v. date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
richard@emfab,net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Flc
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE -49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
httl)s://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv2aBQpHpOOe6rMZMkUEOR%2bGxH GxFe5QkCHzEgvOQveeg%3d%3d
114
1/4/2018
Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
08/18/2017
Date Validated
08/25/2017
Date Pending FBC Approval
08/28/2017
Date Approved
10/10/2017
of Products
Ft # Model, Number or Name I Description
17022.1 1 1 - "5V Crimp" (R6)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions. install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022,2 12 - "5V Crimp" (R6)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions. Install the
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3 13 - "1,5" Mechanical Seam" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report For conditions and
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.4 4 - "1.5" Mechanical Seam" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.5 15 -'"i in. Nall Strip" (R5)
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck wil
fasteners
Installation Instructions
FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.1 5 V CRIMP ssrodf
Created by Independent Third Party: Yes
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof pa
mechanically attached to 15/32" plywood or Wood Deck wii
exposed fasteners
Installation Instructions
FL17022 R7 II FL 17022.2 SCRIMP 0.032 ALUM ssr.o
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssrl
Created by Independent Third Party: Yes
1.5" rib height, 16" wide, 24 gauge steel, standing seam rc
panel mechanically attached to 15/32" plywood or wood de
with clips and fasteners.
Installation Instructions
FL17022 R7 II FL 17022.3 1.5 MECHANICAL
sem ?4 r. df
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.31.5 MECHANICAL
rpm 24oa ssr odf
Created by Independent Third Party: Yes
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Woe
Deck with clips and fasteners.
Installation Instructions
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssr_pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
EL170 2 R7 AE l 7022.4 MECHANCIAL SEAM
ALUMINUM ssr,
Created by Independent Third Party: Yes
1" rib height, 16" wide, 26 gauge steel, standing seam roof
1/4/2018 Florida Building Code Online
panel mechanically attached to 15/32" olvwood or wood de
I
i with fasteners.
Limits of Use
Installation Instructions ry
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL17022 R7 II FL 17Q22.5 1.0 NAILSTRIP ssr.pd
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
I Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions and
Evaluation Reports
F�022 R7 AE FL 17022.5 1.0 NAILSTRIP ssrpdf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
j
instructions.
p
17022.6 16 - "1 in. Nail Strip" (R5)
1" rib height, 16" wide, 0.032" aluminum, standing seam n
panel mechanically attached to attached to 15/32`° plywooc
Wood Deck with fasteners,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032
ALUM ssr.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with the
I FL17022 R7 AE FL 17022.6 1,0 NAIL STRIP 0.032
ALUM ssrpdf
Created by Independent Third Party: Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
1.5" rib height, 19" wide, 26 gauge steel, standing seam rc
17022.7
17 - "1.5 in. Nail Strip" (R5)
panel mechanically attached to 15/32" plywood or wood de
with fasteners.
Limits of Use "
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.7 1.5 Nail Strii) 26GA ssr.odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.8 8 - "EMAX Rib" (115)
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL17022 R7 II FL 177022.8 EMAX Rib ssr.odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 177022.8 EMAX Rib ssr.odf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.9 ! 9 - " Pl3R MAX" (R5) 726
gauge steel, lapped roof panel mechanically attached to
Limits of Use
115/32" plywood or wood deck with exposed fasteners.
installation Instructions
I Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL17022 R7 II FL 17022.9 PBR RIB ssrodf
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A I
Other: Refer to evaluation report for conditions and
Evaluation Reports
FL17022 R7 AE FL 17022,9 PBR RIB
limitations of use. Install the assembly in compliance with the
Created by Independent Third Party: Yes
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions. f
F 0 M
Contact Us :: 7601 Blair Stone Roagi, Tallahassee FL 32399 Phone: 850-487-19z4—
The State of Florida is an AA/EEO emplover. Conyrinht 2Q(17-2013 State of Florida.:: Privacy Stat ent :: Accessibility stent :: Refund Statement
httos://www.floddabuildinq.orgfprlpr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 3/4
2160 SW Poma Drive
Palm City, FL 34990
(.772)B72-8034
Compliant with Florida Building Code 2017 (61" ed.)
Compliant with Florida Product Approval Rule # 61G2O-3
Compliant: Keystone Certifications
Product: l" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support.
Adhesive/Sealant : Bostik 91ST1" Chem -Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads METHOD 1 METHOD 2
DESIGN PRESSURE* -86 PSF Main field -97.25 PSF Perimeter
FASTENER SPACING _ 6" O.C. 6" O.C.
SEAM ADHESIVE Not required 3/16" continuous bead
(see details)
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
EQUIVALENCY: UL1897-04 is equivalent to Test Standard UL1897-12. -Design Pressure mar in of safe 2:1
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial iglVeiting9yrcompany manufacturing or distributing products
under this evaluation. ``4- • g�vy rr
Locke Bowden, P.E. is not owned, operated, or cantralle r,opi phan.Vfpcturer, or distributing products under this
,� ... • r i
report. �r
- -
> f /-2
4 1
seal
r
ms's STATE OF
r� 0 • r y`av
ORO
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t, ed..
2. Minimum slope to be compliant with Florida Building Code 2017 6''' ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 61° ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
16"
314"
i
Panel Profile
16" o.c.
fA
Deck:
-15132" or greater Plywood, or
- Wood plank
Integral Snap Lock
For METHOD 2:
Apply 3116" Bead Bostik 915 TM Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 X 1" Min. per Table "A"
Pancake Head Wood Serew
(Typical Fastening Pattern Across Width)
1"
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
Foefanar
_'-- heck:
- 15132" or greater Plywood, or
- Wood plank
Isometric View
For Method 2
Apply 3116" Bead Bostik 915Tm Sealant
Continuous Along Male Rib Vertical Flange
(Refer to Table "A")