Loading...
HomeMy WebLinkAboutExtreme 1 Inch Nail Strip1/4/2018 Florida Building Code Online w+e SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Se b -r a Product Approval USER: Public User Product Aoproval Menu > Product or Apelication Search > Application List > Application Detail FL # FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 richard@emfab,net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Flc Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed LOCKE BOWDEN the Evaluation Report Florida License PE -49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 UL1897 2012 UL 580 2006 Equivalence of Product Standards Certified By httl)s://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv2aBQpHpOOe6rMZMkUEOR%2bGxH GxFe5QkCHzEgvOQveeg%3d%3d 114 1/4/2018 Florida Building Code Online Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/18/2017 Date Validated 08/25/2017 Date Pending FBC Approval 08/28/2017 Date Approved 10/10/2017 of Products Ft # Model, Number or Name I Description 17022.1 1 1 - "5V Crimp" (R6) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022,2 12 - "5V Crimp" (R6) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 13 - "1,5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report For conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.4 4 - "1.5" Mechanical Seam" (115) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.5 15 -'"i in. Nall Strip" (R5) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck wil fasteners Installation Instructions FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.1 5 V CRIMP ssrodf Created by Independent Third Party: Yes 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof pa mechanically attached to 15/32" plywood or Wood Deck wii exposed fasteners Installation Instructions FL17022 R7 II FL 17022.2 SCRIMP 0.032 ALUM ssr.o Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssrl Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 24 gauge steel, standing seam rc panel mechanically attached to 15/32" plywood or wood de with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.3 1.5 MECHANICAL sem ?4 r. df Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.31.5 MECHANICAL rpm 24oa ssr odf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Woe Deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr_pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports EL170 2 R7 AE l 7022.4 MECHANCIAL SEAM ALUMINUM ssr, Created by Independent Third Party: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof 1/4/2018 Florida Building Code Online panel mechanically attached to 15/32" olvwood or wood de I i with fasteners. Limits of Use Installation Instructions ry Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL17022 R7 II FL 17Q22.5 1.0 NAILSTRIP ssr.pd Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No I Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and Evaluation Reports F�022 R7 AE FL 17022.5 1.0 NAILSTRIP ssrpdf Created by Independent Third Party: Yes limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation j instructions. p 17022.6 16 - "1 in. Nail Strip" (R5) 1" rib height, 16" wide, 0.032" aluminum, standing seam n panel mechanically attached to attached to 15/32`° plywooc Wood Deck with fasteners, Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.pdf Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for conditions and Evaluation Reports limitations of use. Install the assembly in compliance with the I FL17022 R7 AE FL 17022.6 1,0 NAIL STRIP 0.032 ALUM ssrpdf Created by Independent Third Party: Yes installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 1.5" rib height, 19" wide, 26 gauge steel, standing seam rc 17022.7 17 - "1.5 in. Nail Strip" (R5) panel mechanically attached to 15/32" plywood or wood de with fasteners. Limits of Use " Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.7 1.5 Nail Strii) 26GA ssr.odf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Created by Independent Third Party: Yes limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 8 - "EMAX Rib" (115) 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Limits of Use Approved for use in HVHZ: No Installation Instructions FL17022 R7 II FL 177022.8 EMAX Rib ssr.odf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and FL17022 R7 AE FL 177022.8 EMAX Rib ssr.odf Created by Independent Third Party: Yes limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.9 ! 9 - " Pl3R MAX" (R5) 726 gauge steel, lapped roof panel mechanically attached to Limits of Use 115/32" plywood or wood deck with exposed fasteners. installation Instructions I Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL17022 R7 II FL 17022.9 PBR RIB ssrodf Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A I Other: Refer to evaluation report for conditions and Evaluation Reports FL17022 R7 AE FL 17022,9 PBR RIB limitations of use. Install the assembly in compliance with the Created by Independent Third Party: Yes installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. f F 0 M Contact Us :: 7601 Blair Stone Roagi, Tallahassee FL 32399 Phone: 850-487-19z4— The State of Florida is an AA/EEO emplover. Conyrinht 2Q(17-2013 State of Florida.:: Privacy Stat ent :: Accessibility stent :: Refund Statement httos://www.floddabuildinq.orgfprlpr app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 3/4 2160 SW Poma Drive Palm City, FL 34990 (.772)B72-8034 Compliant with Florida Building Code 2017 (61" ed.) Compliant with Florida Product Approval Rule # 61G2O-3 Compliant: Keystone Certifications Product: l" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min. 15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Adhesive/Sealant : Bostik 91ST1" Chem -Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads METHOD 1 METHOD 2 DESIGN PRESSURE* -86 PSF Main field -97.25 PSF Perimeter FASTENER SPACING _ 6" O.C. 6" O.C. SEAM ADHESIVE Not required 3/16" continuous bead (see details) Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 EQUIVALENCY: UL1897-04 is equivalent to Test Standard UL1897-12. -Design Pressure mar in of safe 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial iglVeiting9yrcompany manufacturing or distributing products under this evaluation. ``4- • g�vy rr Locke Bowden, P.E. is not owned, operated, or cantralle r,opi phan.Vfpcturer, or distributing products under this ,� ... • r i report. �r - - > f /-2 4 1 seal r ms's STATE OF r� 0 • r y`av ORO Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t, ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 6''' ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 61° ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details 16" 314" i Panel Profile 16" o.c. fA Deck: -15132" or greater Plywood, or - Wood plank Integral Snap Lock For METHOD 2: Apply 3116" Bead Bostik 915 TM Sealant Continuous Along Male Rib Vertical Flange Fastener #10 X 1" Min. per Table "A" Pancake Head Wood Serew (Typical Fastening Pattern Across Width) 1" FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details Foefanar _'-- heck: - 15132" or greater Plywood, or - Wood plank Isometric View For Method 2 Apply 3116" Bead Bostik 915Tm Sealant Continuous Along Male Rib Vertical Flange (Refer to Table "A")