HomeMy WebLinkAboutCompaction Soil DensitySoil Nuclear Gauge
Report Date: 4/10/2020
Test Method: ASTM D 6938
Port St. Lucie
FBPE CA 0 4930
607 NW commodity cove
Port St. Lude. FL 34886
Phone: 772-924-35751 Fax: 772-924-3580
Client:
GHO Homes Corporation
590 NW Mercantile Place
Port St. Lucie, FL 34986
Project:
15-0338.00
Meadowood Golf & Country Club
Fort Pierce, Florida
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
%
Maximum
Dry Density
(PC')
In Place
Moisture
(%
In Place
Dry Density
(pc
Probe
Depth
to
Percent
Compaction
Min/Max
Comp.
N
Remark
145
4/10/20
P-1
NIA
10.4
120.2
8.1
117.1
12
1 97
95 / 105 1
Pass
146
4/10/20
P-1
N/A
10.41
120.2
8.4
116.5
12
97
95 / 105
Pass
147
4/10/20
P-1
N/A
10.4
120.2
8.0
117.7
12
98
95 / 105
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
145
Above Stripped Surface: Lot 69, Conifer Dr, NW Comer
0-1
Troxter / 3430135058 /
Stone, Brent
146
Above Stripped Surface: Lot 69, Conifer Dr, Center
0-1
Troxrer 13430 / 35058 /
Stone, Brent
147
Above Stripped Surface: Lot 69. Conifer Dr, SE Comer
0-1
Troxler / 3430 / 35058 /
Stone, Brent
Remarks
Comments
Pass: Tests results comply with specifications
108ackscatter*.
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
Gauge calibration data on fie with the testing agency.
'\GENS$
No 63 8
;P'�ebn"-.Kent,
020
P ipion@hftiwer * f E
//ZONAL
s
//Jrrtll�
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1