HomeMy WebLinkAboutPLAN- REVISEDVAC LINE
3.5' DEEP
6' DEEP
SKIMMER
TILED STEP
EDGES
TILED BENCH
EDGE
DECO DRAIN TO DRAIN AWAY FROM THE HOUSE. DECO DRAIN TO BE ATLEAST 1'
FROM HOUSE. DECO DRAIN EXACT LOCATION TO BE DETERMINED IN FIELD.
C O L O R L E D COLOR LED
4 ft.
TRUSSED ROOF PATIO
FLOCRETE AND STAIN
TO MATCH FUTURE ADDITION BY
OWNER. DO NOT
FLOCRETE
4 f t .
2" SUPPLY LINE FOR
FUTURE WATERFEATURE
SET JUST OUTSIDE DECK
AND CAPPED WITH
SEPARATE VALVE
OUTSIDE ANGLE OF REPOSE
6' AND FURTHER = 4" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY
3' TO 6' = 6" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY
0' TO 3' = 8" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY
4 " w a l l s
6 "
5 f t .
3 ft.
6 ft.
9 ft.
8 " w a l l s
EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED:
* SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE SUFFICIENT
TO SECURE SOILS FROM EROSION OR SETTLEMENT
* NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES
* COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDED AT C.O. OF THE
SWIMMING POOL
A N G L E O F R E P O S E
FROM
POWER
SUPPLY
POOL FINISH
APPROVED
GROUND CLAMP
CONTINUOUS BOND WIRE
COMMON TO POOL STEEL,
RAILS & EQUIPMENT
1" LIGHT
CONDUITMINIMUM
WATER LEVEL
POOL PATIO
UNDERWATER
LIGHT DETAIL
(NO SCALE)
UNDERWATER
LIGHT
1 8 "TO MAIN SERVICE PANEL IN
APPROVED CONDUIT (SIZED
PER LOAD)
WIRING TO POOL LIGHT IN
APPROVED CONDUIT
UL APPROVED DECK BOX
FOR DIRECT CONNECTION
TO WET NICHE
UNDERWATER
LIGHT
NOTE: POOL PUMP MOTOR LOCATED ABOVE
GRADE. PROVIDE SEPARATE CIRCUIT FOR
PUMP MOTOR(S)AND HEATER(S) ETC
ELECTRICAL DIAGRAM AND GFI
OUTLET PER 2017 NEC
RAIN TIGHT OUTDOOR
ELECTRICAL PANEL
(SIZED PER LOAD)
APPROVED WIRING IN 1"
SCH 40 PVC W/ #8
BONDING CONDUCTOR
POOL LIGHT SWITCH
EITHER INDOOR OR
OUTDOOR
G.F.I
OUTLET
NOTE: INSTALL 125V 15
AMP WEATHERPROOF
DUPLEX RECEPTACLE AT
LEAST 10' AWAY AND
NOT MORE THAN 20'
FROM THE INSIDE WALL
OF THE POOL
· NOTES:
· (1) POOL PANEL AND SWITCHES MUST BE AT
LEAST 5' FROM THE INSIDE WALL OF THE POOL
·
· (2) ALL ELECTRICAL WIRING AND EQUIPMENT
MUST INSTALLED IN ACCORDANCE WITH THE
2017 EDITION OF THE NATIONAL ELECTRICAL
CODE
·
· (3) PROVIDE PROPER WORKING CLEARANCE
SPACES FOR ELECTRICAL EQUIPMENT AS PER
HO-26 OF NFPA 70
OUTDOOR TIME-CLOCK
PUMP
MOTOR
RETURN LINE
WASTE
SKIMMER
PIPING SCHEMATIC
(NO SCALE)
HAIR & LINT
CATCHER
(COMPONENT OF PUMP)
MUST HOLD 35 PSI FOR AT
LEAST 30 MIN.
PRESSURE
GAUGEFILTER
(2) SEPARATE
DRAINS 36"
APART
PUMP NO
NICHE
(NO SCALE)
CONCRETE DECK
BEND INTO DECK @ 48" O.C. MAX.OVERPOUR
(OR CAP TILE,
WHERE
APPLICABLE
6"X6" TILE
INTERIOR
FINISH
4 "
4 1/2" TYP.
WALL
4" SLAB
2500 FIBER MIX
STEEL-TEX FORM
OR KRAFT WALL
#3 @ 12" O.C.B.W.
NOTE: FOR DEPTHS
GREATER THAN 6' ADD
1- #3 COVE BAR @ 6"
O.C.TO PUMP
6" TYP.
FLOOR
THREADED
PLUG
GRATE SHALL
BE SECURED
IN PLACE SO
THAT TOOLS
ARE
REQUIRED
FOR REMOVAL
GRAVEL BED
NOTE: REMOVE GRATE &
WELL POINT PLUG FROM
MAIN DRAIN & ATTACH AUX.
PUMP LINE WHEN EMPTYING
POOL
TYPICAL WALL
SECTION &
WELL POINT(NO SCALE)
SPECIFICATIONS
POOLS, INC.
CONCRETE
· APPROVED WITH THE 2017 FLORIDA BUILDING CODE
6TH EDITION FOR RESIDENTIAL
AARON H. ALLEN PE, FL REG. NO. 86620 FL
MAX. WIDTH
MIN. DEPTH
15'
SHAPE
FILL FROM EXCAVATION
TILE FILTER
PUMP HP:
TIMER
LIGHTS
TRNFORM:
MAIN DRAIN:
SKIMMER
RETURNS:
VALVED VAC LINE
DISCHARGE LINE
CHLORINATOR JANDY TRU CLEAR SALT SYS
HANDRAIL
DIVING BOARD
HEATER NA
VACUUM HEAD
VACUUM HOSE
LEAF SKIMMER
TREE / STUMP REMOVAL
REMOVE EXISITING CONCRETE
SCREEN ENCLOSURE NA
ELECTRICAL
POOL PATIO CONCRETE FLOCRETE
EXISTING PATIO FLOCRETE
DECK DRAIN INC
GALLON CAPACITY-POOL 13,360GAL.
GALLON CAPACITY-SPA NA
TURN-OVER RATE
TERMITE TREAT BARRIER
MAX. LENGTH 30'
3.5'MAX. DEPTH 6'
CUST
HAUL
ELEVATION T.B.D
INTERIOR FINISH GEM CS200
PUMP MAKE PER FBC 4501.20 JANDY 1.65HP VS FLO PRO
POOL 2.7HP VS FLO PRO SPA NA
INCL
POOL 2CLR LED SPA NA
POOL 300 WATT SPA NA
POOL 2 SPA NA
(1)
POOL 3 SPA NA
JETS:POOL 0 SPA NA
INCL FILL LINE NA
TO GROUND
NA LADDER NA
NA SLIDE NA
INCL
INCL
INCL
POLE
BRUSH
TEST KIT
INCL
INCL
INCL
NA
INCL
6 hrs
INC INC
NA
SKIMMER MIN. FLOW 25 GPM
SURFACE AREA OF POOL – 366SQ. FT 76LN FT
MAX. WATER VELOCITY - 6 ft./s FROM TRUNK LINES
TO 8 ft./s SUCTION LINES, 10fps MAX RETURN LINE
FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011
GENERAL NOTES:
1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS.
2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN-PLACE
CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH.
3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING
CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN.
4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40.
5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL.
6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES.
7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY
LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR.
8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR
WATER DISPOSAL SYSTEM.
9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE
10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE.
11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL
ELECTRICAL CODE- LATEST EDITION.
12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS,
DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE
SMALLER THAN #8 COPPER.
13. NO OVERHEAD OPEN WIRE OVER POOL WATER.
14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA. NO BACK-WASH REQUIRED.
15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL
VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY.
16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING.
JOB NAME: GOEDEKE
ADDRESS: 5814 MYRTLE DR FT. PIERCE
FL 34982
PERMIT NO.:
DATE DRAWN:MARCH 24TH 2020
DRAWN BY: BOBBY AUSTIN
CHECKED BY AARON H. ALLEN
DESIGNER APPROVAL:
CUSTOMER APPROVAL:
SCALE: 1/4" = 1'
A. ALLEN ENGINEERING LLC, CA NO. 33042,
2367 7TH STREET, LA VERNE, CA, 91750
TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND
SPECIFICATIONS COMPLY MINIMUM BUILDING CODES.
STEP DETAIL
1. TREAD IS MIN. OF 10" WIDE.
2. RISER NOT GREATER THAN 12" EXCEPT IF MORE
THAN (3) TREADS ARE USED.
3. ALL STEPS TO BE SOLID GUNITE 3000 PSI.
MISC. NOTES
1. ALL STEPS AND SWIMOUT BENCH EDGES
WILL HAVE 2X6 CAPTILE BORDER OF
OPPOSITE COLOR OF GEM FINISH FOR
VISIBILITY
2. HAND HOLD TO BE INSTALLED AT ARE
WHERE DECK RAISED +6"
ABOVE POOL
N.T.S.
12" MAX.
10" MIN.
STEPS
#8 GROUND WIRE
HANDRAIL BONDING DETAIL
WHERE APPLICABLE
PER NATIONAL ELECTRICAL CODE48" MAX WATER
DEPTH
W.L.
18" MIN.
( ENTIRE PERIMETER)
#8 SOLID COPPER BOND
WIRE W/ APPR. CLAMPS
(ONE ON EACH SIDE OF
POOL 4 TOTAL )
8 GAUGE SOLID COPPER WIRE
EQUIPOTENTIAL BONDING GRID DETAIL
PER N.E.C. 2017 SEC. 680.26
(WHERE ADOPTED)
SOIL
MINIMUM 18" (MAXIMUM 24") FROM EDGE OF POOL
AROUND ENTIRE POOL PERIMETER BURIED 4" TO 6"
DEEP
PAVER DECK OR CONCRETE DECK
LOCATION OF WATER BOND
BY POOL EQUIPMENT
PB-2008
WATER
BONDING WIRE
TO GRID
POOLBOND PB-2008
IN ACCORDANCE WITH 680.2 C POOL WATER SHALL BE IN DIRECT CONTACT
WITH AN APPROVED CORROSION-RESISTANT CONDUCTIVE SURFACE THAT
EXPOSES NOT LESS THAN 9 INCHES (5800 MM) OF SURFACE AREA TO THE
POOL WATER AT ALL TIME.
FOOTER DETAIL
8"
NO SCALE
(1) #5 REBAR
OR (2) # 3 REBAR
8"
REBAR SHALL BE COVERED BY A
MINIMUM OF 2.5"
N.T.SN.T.SN.T.S
N.T.S
N.T.S
0
003'
30'
3.5'
6'
27'
CYCOLAC MAIN DRAIN
LIGHT
1 ROW OF WATERLINE TILE
1' R
#3 STEEL @ 12" O/C E.W.
6" THICK
WATERLINE
DECK
WALLS
SHALL
NOT
SLOPE
GREATER
THAN 11
FLOOR SLOPES
FLOOR SLOPES SHALL BE
REASONABLY UNIFORM AND
COMPLY WITH ARTICLES 5.6.1
THRU 5.6.3
THE SLOPE OF THE FLOOR FROM
THE SHALLOW END WALL
TOWARDS THE DEEP AREA SHALL
NOT EXCEED 1 FOOT IN 7 FOOT
4 ½” THICK
TYPICAL SECTION THRU POOL
(NO SCALE)
N.T.S.
N.T.S
N.T.S
N.T.S
CHILD BARRIER BY OWNER THROUGH 6' WOOD
PRIVACY FENCE WITH SELF LATCHING SELF
CLOSING GATES. LATCHES TO BE ATLEAST
54" TALL AND DOOR AND WINDOW ALARMS
EQUIPMENT
PAD
PER FBC
R4501.22
VERIFY
EXACT
LOCATION IN
FIELD WITH
SUPERVISOR
*LOCATION OF GFI
RECEPTACLE
TO BE DETERMINED IN
FIELD PER NEC 680
SAFETY BARRIER PER FRC R4501.17.1-
R4501.17.3 & ASTM5034-95, ASTM D3787-
89, ASTM 653-96
POOL BARRIER PER FRC R4501.17.1-
R4501.17.3 AND ANSI/NSPI-5-1995
LEGEND
1. 2" VACUUM LINE
2. 3" POOL MAIN DRAIN
3. 2" SKIMMER LINE
4. 2.5" POOL RETURN LINE TO FIRST TEE, 1.5" TO POOL
5. JANDY TRUE CLEAR SALT SYSTEM
A. 1.5" TO WASTE OR DISCHARGE TO GROUND
B. 1HP JANDY VARIABLE FHPM PUMP WITH W/APPR HAIR AND LINT STRAINER
C. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE
D. VALVES (TYPICAL)
E. INSTALL PERMA-CAST WATER BOND OR APPROVED EQUAL TIED TO PUMP
GROUND W/ #8 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA
EXPOSED TO WATER) PER MFGR’S SPECS (FIELD VERIFY LOCATION)
MANUAL MOTOR STARTER SWITCH
2.7HP VARIABLE SPEED JANDY PUMP
MOTOR WITH BUILT-IN OVERLOAD
SWITCH W/3- #10 THHN CU WITHIN ½”
MIN. CONDUIT (GFCI PROTECTED)
TIME CLOCK
W. P. DISCONNECT
12 VOLT TRANSFORMER
JUNCTION BOX
(2) POOL LIGHTS
(GFI NOT REQUIRED)
S.P.S.T. TOGGLE SWITCH
POOL PANEL W/ 40 AMP
BRKR & (2)-#6 & (2) #10 GND
THHN CU IN 1" RPVC CONDUIT
ELECTRICAL DIAGRAM N.T.S.
1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR TO VERIFY
ADEQUATE CAPACITY AT POINT OF CONNECTION
2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT(S)
3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/#8 SOLID, BARE COPPER.
4. PROVIDE W.P.G.F.I. OUTLET 10' MIN. -20' MAX. FROM WATER’S EDGE.
5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B)
ELECTRICAL DIAGRAM AND
GFI OUTLET PER 2017 NEC
PUMP BONDED
BACK TO POOL
JANDY TRUE CLEAR SALT
SYSTEM
ELEVATION DROP TO BE DETERMINED
IN FIELD. 1 STEP IF DROP IS LESS
THAN 8". 2 STEPS IF DROP IS LESS
THAN 16". IF 2 STEPS ARE REQUIRED
THEY ARE TO BE UNIFORM.
HIGH SPEED
LOW SPEED
JANDY PRO SERIES VS FloPro Series Pump
VS-FHP2.7 Performance Curve
POOL RETURN LINES 2.5" TO FIRST TEE
POOL DETAIL
MINIMUM (2) SUCTION LINES PER PUMP 3 FT. SEPARATION
OR SEPARATE PLANES
3 FT. MIN.
8 FPS MAX
6 FPS MAX
2.5" SUCTION LINE TO PUMP
MAX 117 G.P.M.
3" PLUMBING LINES FROM
SUMP W/ 3" TEE
APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B.
ASME/ANSI 112.19.8-2007
TO FILTRATION PUMP
· APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL WITH
THE 2017 SUPPLEMENTS AND THE ANSI/APSP-7 2006 FOR SUCTION
ENTRAPMENT AVOIDANCE
REC PUMP = 2.7HP JANDY VARIABLE FLO PRO VARIABLE SPEED
LOW SPEED – 36 GPM MAX
HIGH SPEED = 117 GPM @ 20 TDH
3" SUCTION PIPE @ 117 GPM = 5.63 FT/SEC.
(8 FT./SEC. MAX. – SUCTION LINES)
3" BRANCH PIPE @ 60 GPM = 4.13 FT./SEC.
(6 FT./SEC. MAX. – PRESSURE LINES)
2.5" PRESSURE PIPE @ 117 GPM = 8.43 FT./SEC.
(10 FT./SEC. MAX. – PRESSURE LINES)
200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM
BACKWASH VALVE NO
N.T.S
SWIMOUTS
WHEN PROVIDED SHALL BE
AT 20" MAX. BELOW THE
WATERLINE
18"
N.T.S.
Per F.R.C. 4501.18 AND ANSI/NSPI-5-
2003
20" max.
STOCKPILE FILL AS NEEDED
FOR FINISHED GRADE
ANSI-7/ANSI-15
A
4
B
1
23
EQUIPMENT LAYOUT N.T.S.
5
PIPING SCHEMATIC
E
D C
18 ft.16 ft.
2.5" RETURN LINE TO
FIRST TEE
DOOR AND WINDOW ALARMSX
X X
X
X
X X
2"
R
R
1"1.5"1"
1.5"
1.5"
2"
3"
3"
2.5"
OVERHEAD POWER
LINE
1 8 f t .
BUBBLER
R1.5"
1.5"
1.5"
4
f
t
.
1
3
f
t
.34 ft.
BUBBLER
5
f
t
.
5
f
t
.
11 ft. 9 in.
1 8 f t .
2"