HomeMy WebLinkAboutBuilding PlansR-J Inverter Type: Enphase PV Panel: (37) Q-Cells 315 W Racking: Everest Total Wattage: 1I,655W Roof Type: Metal Wind Load: 7 to 27 Deg Fastener Type: Use Roof Tech Mini's Sheet Index S-1 Cover Sheet / Site Plan S-2 Detail E-1 One - Line S-lA Mounting Plan General Notes: -Enphase IQ7 Micro Inverter are located on roof behind each module. -First responder access maintained and from adjacent roof. -Wire run from array to connection is 40 feet. \\\\\"-%0 -C.. O�?.�vt;ENgO y/% i �' `✓ `ST OF IOP,• �ONA� Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com 2' Access Pathway R-1 # Modules (37) Pitch: 20' Azimuth: 269' ST•LUCIE COUNTY P= BLDG:_ DATE,; ELE DATH3=t2 PLUMB: DgTE:- MECH: DATE: Access Pathway =RE -TER' n_Y.9 �..d�. Vb. nJ11:'16+.•.PORT IME8 NR S, DE3 EAR NG. I Ea -COGEN Disconnect Located adjacent to Utility meter Utility Meter ®r� FRONT OF BARN System meets the requirements of NFPA 12015 Edition, Chapter l 1.12 Install will be done to Manufacturer Spec Meets All Editions of Florida Fire Prevention Code 6th Edition Legend ® Chimney ® First responder access Q, Satellite 0 Utility Meter o Vent Pipe Represents all Fire Clearance 1st Responder Access EP PV Disconnect includingAlternative methods minimum of 36" unobstructed as per Section R324 of the 2015 IRC 2017 FL Residential Code & FBC ,6th Edition (2015 International Residential Code - 2nd Printing modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015 International Energy Conservation Code, County of Saint Lucie Code, 2014 National Electric Code Customer Info: David Zoerhof 10020 Orange Ave. Fort Pierce, FL 34945 Layout Subject to Change Based on Site Conditions Date: Drawn r-LORI&T ER M A N A G T " 1331 Green Forest Ct, Ste 3 Winter Garden FL, 34787 407-926-0233 2.26.2020 GM I Rev Date: 1 91 Everest General Notes: - Roof Tech Mini's are secured to wooden purlins @ 48" O.C. using (2) M5 x 60mm stainless steel Lag bolts. - Subject roof has One layer. - All penetrations are sealed. Roof Section Pitch Roof Rafter and Spacing Overhang Notes: R1 4/12 211x6" @ 12' O.C. 0" Horizontal Purlins Designed as per ASCE7-10 Modules mounted flush to roof no higher than 6" above surface. Inverter Type: PV Panel: Racking: Total Wattage Roof Type: Wind Load: Fastener Type 3/8-16 X 3/d HEX HEAD BOLT 3/8-16 FLANGE NUT Solar Module 3-5/8" Install will be done to Manufacturer Spec Godwin Engineering an Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com Customer Info: Enphase (37) Q-Cells 315W Everest David Zoerhof Date: 11,655W y: b Metal 10020 Orange Ave. Drawn Drawn b 7 to 27 Deg CheckFort Pierce FL 34945 Rev #: 00 Use Roof Tech Mini's � Rev Date: of- leiyG��syi. ,yam * �' 0 8136p , s� 'r"Ay� of 'PC � a FLO.RIDdWER M A N h G'E• t\1E N T 1331 Green Forest Ct, Ste 3 Winter Garden FL, 34787 407-926-0233 2.26.2020 GM S-2 - SOLAR PV,sYiT[M MUWPEO1Y , RAPIOSKU=OWN - WARNING ([iaP liuscihutpcwi�:.. . SWrTp110.r11E DUAL POWER SUPPLY "aer•rp$noxm+ SOURCES: UTILITY GRID AND sau.ARD R pVSYniH1 PV SOLAR ELECTRIC SYSTEM _lSNM P�RP.11:' _ Figure 690.56(C)(1)(a) Label for PV Systems that Shut down the array and the conductors leaving the array wanruNc: INVERTER OUTPUT CONNECTION: DO NOT RELOCATE THIS OVERCURRENT DEVICE Photovoltaics: (37) Hanwha Q.Peak Duo BLK 315W En a e Cable Inverters: (37) Enphase IQ7 Micro Inverters Circuits: (2) circuits of (12) Modules NEMA 3R (1) circuit of (13) Modules Junction Box Maximum Inverters Per 20A Circuit (16) # 12 AWG THWN for Home runs under 100' Black - Ll Roof # 10 AWG THWN for Home runs over 100' Red - L2 (1) Line 1 Green - Ground (1) Line 2 Per Circuit #8 AWG THWN (1) EGC Inside @ least 3/4" Conduit (tbd on site) Meter ' • 1 • _A ATEOACOUMCURRENii A NOMINAL 1 ow y +._. OPERATINGACYOITAGE '^V, Line Side Ta Manual Disconnect 60A Service Rated Fused Disconnect Enphase Combiner Box Neutral to Ground Bond AC Disconnect 50A Fuse (1)-20A Breaker -------- ---- Per Circuit Disconnect N #6 AWG THWN (1) Line I #6 AWG THWN (1) Line 2 (1) Line I (1)Neutral (1)Line 25Typicafly — — - #8 (1) EGC (1) Neutral= — in @ least 3/4" Conduit Typically in @ least 3/4" Cond (1)#8 AWG EGC & GEC meets the requirements ofNFPA I Including the label below In Case of Emergency Call Florida Power Management at 407-926-0233 11.12 Note: -All wiring to meet the 2014 NEC and Florida electric codes. 60A Disconnect -Type of conduit to be determined on site by contractor. GEC NOTES Provide a grounding electrode system for an ungrounded system per 690.47(C)(3). - GEC must be installed per 250.64 - GEC most be continuous un-spliced or irreversibly spliced from inverter to existing service ground system or continuous from the arrays to the existing service ground system. - If GEC is not continuous from the array to the existing service ground an additional ground system must be provided from the arrays to a grounding electrode per 690.47(D) - GEC must be min #8 AWG and installed in conduit Customer Info: Enphase Output Ckt Per String To Overcurrent Protection Device AC Max Output Current 13 AC Max Output Current * 1.25% 16.3 Overcurrent Protection A 20 No. of Current Carrying Cond <4 Conductor Gauge AWG 10 Enphase Total Output Ckt AC Max Output Current 37 AC Max Output Current * 1.25°/D 46.3 Overcurrent Protection A) 50 No. of Current Carrying Cond <4 Conductor Gauge (AWG) 6 NEC LABEL NOTES: 1. THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH NEC 110.21(B) 2. LABELS SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. S. LABELS TO BE A MIN LETTER HEIGHT OF at8" AND PERMANENTLY AFFIXED. 4. LABELS SHALL ALSO COMPLY WITH THE SPECIFIC REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. Main Distribution Panel 200A Main Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com EA/s���/� 1360 . Z �G_RIoP '��N N ELORIDl1... �1lER Rererto NEC 7128 for MA N A GF„ty1� N T-' Condifions on taps in switcM1 T.�: cad over Eat devices Eaclosares. 1331 Green Forest Ct Ste 3 Ifthe conditions are not s metatabb.a'a ll Winter Garden FL 34787 need to M1e installed. f Date: David Zoerhof I Drawn 10020 Orange Ave. Fort Pierce, FL 34945 1. ,,G"`G" 1 Rev #: Rev Date: Page: 407-926-0233 2.26.2020 GM E-1 Install will be done to Manufacturer 221 71— 1 11 n n n n r n n n 'L IL fl I I 1 kl M (LL, i II U L U U L L U U U 'LI U L LI L L L I U U Unru= — 011 i i r � r r � r a r r r I 1 1 r 1 i r i e r 'L IL �L IL IL �L �L IG �U IL• iL L +L IL +C 'L'L +L �L QL S • • 1 4 • • I 4 'U U L L L U U L L L L L 14' 71 41 Splice Bar p Mounts 76 Mids 48 Ends/End Caps 52 Combiner 1 Ground Lugs 13 25 Inverter Type: PV Panel: Racking: Total Wattage: Roof Type: Wind Load: Fastener Type: Max cantilever is 16" as per manufacturer spec. Max Cantilever = Max Span * 61)=48*61)=16" Enphase (37) Q-Cells 315W Everest 11,655W Metal 7 to 27 Deg Use Roof Tech Mini's Customer Info: David Zoerhof 10020 Orange Ave. Fort Pierce, FL 34945 31-311 51-611 Install will be done to Manufacturer Spec Godwin Engineering and Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com \����1111 I II �►,,, C- 60Nz t FLORID P WER MA N A G T 1331 Green Forest Ct, Ste 3 Winter Garden FL, 34787 407-926-0233 Rev #: 00 Rev Date: 2.26.2020 GM i, gUQi The new Q.PEAK DUO BLK-G5 solar module from Q CELLS impresses with its outstanding visual appearance and particularly high performance on a small surface thanks to the innovative %ANTUM DUO Technology. Q.ANTUM's world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding performance under real conditions - both with law -intensity solar radiation as well as on hot, clear summer days. Q.ANTUM TECHNOLOGY. LOW LEVELIZED COST OF ELECTRICITY m'J Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.3 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QM. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (540OPa) and wind loads (4000Pa) regarding IEC. ® A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance guarantee2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. THE IDEAL SOLUTION FOR: 13 Rooftop arrays on residential buildings QCEUS, liogbwtxo vJ: - - _-- 2018` .r7uatity Testetl i,i .�a� I +.wea+e ±NaYsamil ID.40032587 ' APT test conditions according to IEC/TS 62804-1:2015, method B (-1500V, 168h) 2 See data sheet on rear for further information. Format 66.3 inx39.4 in x 1.26 in (including frame) (1685 mm x 1000mm x 32 mm) n.uaa.w Weight 41.2 lbs(18.7 kg) + + •.e..a�,sue.nmusw y. n„$ El d Front Cover 0.13 in (3.2 mind thermally pre -stressed glass with anti -reflection technology Back Cover compositefilm Frame Black anodized aluminum Call 6 x 20 mgnocrystalline O.ANTUM solar half -cells ]unction box 2.76-3.35 in x 1.97-2.76 in x 0.51-0.93 in (70-85 mm x 50-70 man 13-21 mm), decentralized, I P67 + •...a.:..e.'..•+ "O" �°°' Cable 4mm'Solar cable; (+)a43.3 in(1100 mm), I-) a43.3 in (I 100mm) Connector Multi -Contact MC4, IP68 ELECTRICAL CHARACTERISTICS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCES W /-O W) Power at MPP' P. [W] 300 305 310 315 320 Short Circuit Current' 6 [A] 9.72 9.78 9.93 9.89 9.94 e Open Circuit Voltage' Vor IV]39.48 39.75 40.02 40.29 40.56 E g Currant at MPP IW, [A] 9.25 9.31 9.36 9.41 9.47 Voltage at MPP V. M 32.43 32.78 33.12 33.46 33.80 Efficiency' q [%] 217.8 218.1 z18.4 218.7 219.0 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOV Power at MPP I P,e, DID 224.1 227.8 231.6 235.3 239.1 e Short Circuit Current 1¢ W 7.83 7.88 7.92 7.97 8.01 Open Circuit Voltage V. IV] 37.15 37.40 37.66 37.91 38.17 g Current at MPP I,e, [A] 7.28 7.32 7.37 7.41 7.45 Voltage at MPP V. IV] 30.78 31.11 n i 44 31.76 32.08 'Measurement tolerances P,,, t3%; Lw,Va.5%at STC: 1000W/mr, 25s TC, AM 1.5G acwrdingto IEC 60904 3 - r800 W/m•, NMOT, specWm AM 1.5G -rOCELLS'.PEREORM"bEEW,ARRANTYc _� �PERFORMpNCEAT;LOW IBRADIANC_E -_ tl _al r® At least98% of nominal power during first year, Thereafter .max 1%0.54%poavrdegradation per year. e At least 93.1 % of nominal power up to 10 Years. x10--T----- r----- '----n-----' ---- G 'a -ocros � mua,a""'w.naw.a`a"`�`a . ----------' --------------- At least 85%af nominal power upto 25 years. E : m All data within measurement tolerances. Full warranties in accordance with the warranty I 3 terms of the 0 CELLS sales organization of your respective country. m •m w ass ,ao ImmoumEMw m v a Typical module performance under low mradlance cond itions in .ru!.rae w.r, ieed...�zmn comparison to STC condition(25'C, 1000W/tar). i`lEoMyPERATURECOEfFICIE St. - Temperature Goa i !a of Itt ¢ [%1 +0.04 Temperature Coof iciant of Vo Il [%/10 �~ -0.28 Temperature Coefficient of Pm, y 1%/10 -0.37 Normal Operating Module Temperature NMOT 171 109 x5.4 (43 t3'C) PROPERTIESr• SYSTEM DESIGN Maximum System Voltage V. IV] 1000(IEC) 11000(UL) Safety Class II Maximum Series Fuse Rafing [ADC] 20 Fire Rating C OEC) I TYPE 1 ILL) Max. Dazign Load, Push / Pull (ULY [I mM9 75 (3600 Pal 155 (2667 Pa) Permitted module temperature -40'F up to +185°F on continuous duty (-40'C up to+85*0 Max. Test Load, Push/Pull (ULP [Ibs/89 113 (5400 Pa) / 84 (4000 Pa) 'see installation manual UL 1703; VDE Quality Tested; CE-compliant; IEC 61215:2016; IEC 61730:2016, Application class A OVE C E C 9^ us Number of Modules per Pallet Number of Pallets par 53' Trailer Number of Pallem per 40' High Cube Container Pallet Dimensions (L x W x H) I Pallet Weight NOTE, Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further of this Product. Hamaba O CELLS America Inc. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618, USA I TEL+1 949 748 59 961 EMAIL Inquiry®us.q-cells.com I WEB wwwgcells.us 32 30 26 69.3 in x 45.3in x 46.9 in (1760mm x 1150mm x 1190mm) 1415lbs (642 kid MAR 0 4 2020 Engineered in Germany uS O- ST. Lucie Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ f' and Q , 11 V - To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro'" and Enphase IQ 7+ Micro - dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy"', Enphase IQ Battery'", and the Enphase Enlighten' monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved, lighter two -wire cabling • Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell* modules • More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) -The IQ 7+ Micro is required to support 72-cell modules. 0M ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters - INPUTDATA(DC),i -- _ -ilQ7.60-2_uS./IQ?-6U-a-US;- 'IWPLUSe72-2=US l.IQ7PLUS-72-8-.US- 'Commonly,usedmodulepairrdgs'_ 235W-350ft - �235W 4401W+ Module compatibility, 60-cellpVmodulesanly •60-- cell and 72ceIIP1 odules y xtvlaxl�,mu�miµnpgtDGvoltagr Peak�powertrackingvolts' e 27V-37V� 27V 45-V w0peratingrange• _ MIQ/Max start voltage. _u16,Vy�:'�`�`�`�"- 22.Vy 48 Y ;22�Vl. 60'.V' ,Max DC; port Ic rcui[ Ghent(module_ rJso�'. ';15Q`y j5A`, OveNo0 eclaasDeport _ DG on, baokfeetl currentO Arm-� O A PV array;configu-ragq{j _ �JpRjupgroupdedwray;(boadOltonarpQsjde protectiogregpjrO - `- L �.pCslde"protect(on`requi[¢smax20A+perbfandh circuit_ MiclfolnVertet>-------•.•IQ7tMlaroinv_ettef___ ,Peakoutptitpo+Wer"--- -250VAi _ 4295VA- ,_ 1NaxirnUrncontinGousolJtputpower- �_ -_- 240Va 290VA No[inaf�C L)voZtage`/range' "- -�240X /r- J 208Vii 240V(-. -� `208`- - ' 1B3'229V I2T1264-T iB3.229V - MaximAnngtt tinuqus;ou)put'Current:r _2f1264V S1 0A (241) Vt' 'la$,A:(208V) j!2t A(2481V.). '1:39•A.(20aV) - t�-Jominal f equ y 6D ..P P �.4z • _ _ _ _Eztended.frepgeody_range' - ,, •47 68W 47-AllHz shoitclicuit Paul uri ni over3:syclas., -5 8 Arrri K5$ Armsi- MAximum units pec20-A (LL) branch crrcgiN_I ,_�� 16 (24 AVAC) ,J (20S VAC) T3 C 4i VA• C) — 11 208-VAC)j - �.Y u _ .-- _ _.._.. _ _ A - -.. -.. �bvervoltage'elasgrt •:111 ,III _ "— "' AOporTbackfeedcurrent OA GA fAoW_erfac[orsGttl09f�. ..�.4.,�.ty0 r10 "- _ >~> •Potyerfact`ot adpastable)._ �� 0,71eadmg�,07 agl 91ir9�- ---L071eddlrtg;,.0�.(a991h9-- 9 .EFFTCIENGY;.- _!@240,V- •:@20B�Y •@2411V1 '@20,8;Y'� - - - P�GEG'effici.+en.�->y.:...-^-_�7:6.�'97B.,r�.'.. _--- �'8..«�'.,�.__.�,�..e�...,..__.....�...r..._..�: �.'n9.Ta•�� !CEG;welghtedgt6ce;Opy'97:0.%_ - -- -'97;0`_°G_ _ ,'9710.�- 'MECHAMCAL.DATA - "- - - - - - - --- - - - I mblentterriperat��? n e "a46°Dt10 G� r y - Reat%e'humidhyran9el 4 to100 (cand¢nsin9)• _ :.on,. dtortypLQI_ 60-B.US&'Iq/PLUS72-6=llS):Arendsj;V2'(MC41gt¢pnateahie)., , - Adaptor4'(ormoduleswith,jvlC4orlJTkcgnji�ctots'i .:PV2to MC4:�ard'erliGA-S20?S22" PV2 tti C,IT)(r order. ECA-S20-$2$� Dirnbirssiori's V�I xFiXD} � 212 mm 77$mm 30^2mm Wl u[`6rac�iet)� "� Weight1 _ OBk9.(2/3$dbs) 5Coolrn 1Naturalco ion- 0.ans T Approy�d;forWetlogatrons Yes. Pa(luli no tl g es __'.. 03u ._..___r'__.�,e'...._`� __ ..,...._.__-..n•,_-„ ..,,,_...,.,,,_ Enclosur¢ Classll dgLp)e IRSUlated, cgmosron resistan[polynierlcenc 6 l6sure - EnYi[onmental,'cate�otygyUVexpoSueraUn9i:�,NEMAirypefiJroutdoo[-`-'" FEATURES' Communi6aticn • ` ;Powerllne'Cpmmunleatibn(PL'G)k - - - Monitoring °.Eniigfiten Pie gdget dod NlyEnitghteri monitoring options. ' Both options require Installation of an Enphase IQEnvoy_, 1Disconhecfinms gean`-'-�""-" SheF(CandEOCconne'clois'havefieen ve a(oaee2andapprfaW ovedbyULru-q theloadbree'ks - disconnect [?qulfed 6y; EG690, C6mPl'Ldnce 'CARule.21(UL 174i SA): UL 62169-1, UL17411JEE0547 FCC Pdrt 15 Class B,. ICES 0003 Class B, r`ARI/neA_r9n Qxl(t•1nZ•1.r(T "' This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at hitps,//ennhase.com/en-us/supoon/module-comoat'h'I ty. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings, visit enphase.com @ 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-0-24 ENPHASE. CrossRaif System 'solarsystem 11 10 �P tl �u Item No. 1 Description EverFlash eComp Kit, Silver or Black Product 4000367, 4000366 2 Lacj.Bolt_D745116 k,4": SS- '4000359 3 L-Foot Slotted Set, Mill or Dark 4000630, 4000631 - Crossftail 80.168" Rail;'Mill 4000508 5 CrossRail 80 End Cap, Black 4001221 CrossRa11'48-XC166",'MIII'ori0ark 400069S; 4000205 -___ 7 CrossRail 48-X/48-XL End Cap 4000433 ;8 CrossRail48X:,166 or1.75",Mlll',or:DaPk 900D662;14000675„4000663 9 CrossRail 48-X/48-XL 3" Sleeve 4000583 l0, ___ : GR:MidClamp:Silver.or,Dark- __ - _ ;'01, 40006 4000602_. CrossRail 48-X Mechanical Properties CrossRail 46-A Material 6000 Series Aluminum :,.Ultimate TensileStreiigth 37,7 ksi (260:MP.a) ' Yield Strength 34.8 ksi (240 MPa) j*1ghi• :0.56 lbs/ft (0.833,k9 i). Finish Mill or Dark Anodized Section Properties CrossRail 48-X Sx 0.199 in3 (3.261 cm3) +Sy507•ctri3)`- A (X-Section) 0.467 in2 (3.013 cm2) 1391 84216.401 1.54 � 166 u t 4 [481 b 1.89 Dimensions in (mm] Inches Notes: 0 Structural values and span charts determined in accordance with Aluminum Design Manual and ASCE 7-10 � UL2703 Listed System for Fire and Bonding www.everest-solarsystems.com www.everest-solarsystems.com