Loading...
HomeMy WebLinkAboutPlansa I LOT 1 LOT 2 LEGAL DESCRIPTION m BEING ALL OF LOT 3 AND THE NORTH 90 FEET OF LOT 4, BLOCK 33. ACCORDING TO THE PLAT OF INDIAN RIVER ESTATES UNIT FOUR, AS RECORDED IN PLAT BOOK _ OE_ _ _ _ _ OE- _ 30' ALLEY INDIAN RIVER ESTATES 10, PAGE 49, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. --OE-_-_-°E--- ___ UNIMPROVED UNIT 4 PLAT BOOK 10, OE- _ _ - _ � OE oE- _ _ _ _ pE_ _ _ _ - _ CONTAINING 0.960 ACRES, MORE OR LESS. °E - - - of _ _ PAGE 49 - OE- _ _ - _ PROPERTY ADDRESS N89'51'47"W 220.00' °E---"0 - FND 5/8" IR 4606 MAGNOLIA DRIVE, PORT ST. LUCIE, FLORIDA 34952 m LOT 3, BLOCK 33 a NO ID FND 1/2" IR INDIAN RIVER ESTATES I i 0.42' N, 2.18' W LEGEND & ABBREVIATIONS NO ID UNIT 4 I N I A/C - AIR CONDITIONER O.R. - omaAL RECORDS BOOK ` • FND 1/2" IR PLAT BOOK 10, - I � I P.S.M. - PROFESSIONAL SURVEYOR R YAPPER 0 NO ID PAGE 49 I o C.M.- NEARING SASE m C.- CONCRETE MONUMENT P.L.S. - PROFESSIONAL LAND SURVEYOR 0.15' N, 0.24' W I CONC - CONCRETE (P) - PLATLAT DATA CBS - CONCRETE STRUCTURE P.C.P. - PERMANENT CONTROL POINT C4 SEPTIC y��co ° pyJELi. O I D.E. RADIUS -DRAINAGE EASEMENT R/W - RIGHT OF WAY ,.223 F.F.E - FINISH FLOOR ELEVATION U.E. - UTILITY EASEMENT orO TANK �aOGV I Lam• - IR RATION QUALITY WATER 0 - INCLUDED ANGLE 0 2�p �,�FO�`Q 4' CHAINLINK I I Lac - [RON ROD AND CAP - LICENSED BUSINESS # - LIGHT OLE ROD @ CAP LEE 42s8 � 0 0 1. 3� .16 FENCE TRACT C, BLOCK 33 L - ARC LENGTH e N po> yG� y�' �. INDIAN RIVER ESTATES L.M.E. - LAKE MANAGEMENT EASEMENT � - WOOD POWER POLE i _ _ I UNIT 4 LE. LANDSCAPE EASEMENT TI - FIRE HYDRANT PLAT BOOK 10, (M) - MEASURED DATA a - MALsox fa '� o 'I`/ I PAGE 49 NO L0. - NO HOLE IDENTIFICATION ® - WATER METER CY ?r �0 EXISTING q,�': I VACANT (NR) - NON RADIAL UNE - WATER VALVE I ZI $,. 1 STORY •o I - GUY ANCHORI .COVERED RESIDENCE ry I I �. GRAPHIC SCALE m .-ENTRY.so 15 30 ... ASPHALT \ / 4.19' O 4 DRIVEWAY DRIVEWAY �oo �/ I 0 -- — - - -- - ya-- s -- — — - - - GENERAL NOTES 1 � -- 3 )EL 5p. 9s WOOD _n n3s III 1) The last date of field work was 1-24-2020. CONC AC DECK p' bbb 3 2) Additions or deletions to survey maps or reports by other than the signing party or .moo Sry? &PUMP PAD parties is prohibited without written consent of the signing party or parties. p, 12"x18 �' WELL 3) Reproductions of this map are not valid without the signature and original raised z F: CMP 85; - 6' UE� i seal of a Florida Licensed Surveyor and Mapper. <o i PER PLAT I 4) Lands shown hereon were not abstracted by this office for rights -of -way, I? Z easements of record, ownership, abandonment's, deed restrictions, or Murphy Act In !' NORTH 90.00' OF Deeds. This information should be obtained through appropriate title verification. o e sg; - ,�.' LOT 4, BLOCK 33 I i 5) All above ground fixed improvements, if any have been located and shown hereon. {� •b INDIAN RIVER ESTATES 6) Underground foundations and improvements were not located as part of this survey. UNIT 4 7 Flood Note: B PROPOSED � PLAT BOOK 10, 4' CHAINLINK I ) y graphic plotting only, this property is in Zone X, according to I ®I b METAL BUILDING PAGE 49 FENCE �4 the Flood Insurance Rate Map, Community Panel No. 12111CO193 J, Map Revised Q IL- o •<" 3.2' INSIDE February 16 2012 The exact designation can only be determined by an elevation F.F.EL�100.80' its -E m PROPERTY certificate. No additional search of the public records has been preformed. There Z W 4' CHAINLINK I may be additional map Amendments affecting this property. HO_1 m FENCE 8) The bearings shown hereon are based on Plat information and are referenced :Q m a 1.9' OUTSIDE I xi to the East right-of-way of Magnolia Drive which bears North 00'03'24" West m E( z sUf<a PROPERTY and all bearings are relative thereto. {— dH�d9) No easements are shown hereon other than those depicted on the plat. No f _ 4N8�9*53'21OW 220.00 search of the public records has been performed to find additional easements -� o I , that may exist. o $3�i9 FihO FND 5/8" IR • a o The building setbacks, if shown hereon, although based on the best available m SHQIS _ -__ _ _ _ __- _ __ _-.. NO ID information, are not certified to and must be verified prior to design or construction. LOT 5, BLOCK 33 0.48' N. 0.80' W I 11) Boundary information was provided from a survey by Meridian Associates, Inc., Survey INDIAN RIVER ESTATES -��L�Cc� x UNIT 4 No. MPLC-2117, dated 05/13/04. PLAT BOOK 10, 12) Purpose of site plan is to show the proposed metal building for permitting. I-1`•n 319 "•I'1 PAGE 49 13) Elevations shown hereon are based on an assumed elevation of 100.00' at the ��� CS�41d]� IT{�1 OCCUPIED centerline of pavement, crown of road, of Magnolia Drive as shown. THOMAS P.•KIERNAN DATE Professional Surveyor & Mapper Florida Certificate No. 6199 ADD WELL/SEPTIC AND ELEVATIONS I JDJ 1 2/17/2020 I 6'-3 WINDOW BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THIS STRUCTURE IS DESIGNED AS A NON -HABITABLE UTILITY/STORAGE BUILDING (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS UST, AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNERS RISK. CARPORTS ANYWHERE NOR THE ENGINEERING DESIGN SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION C701.4.2. 4. ALL STEEL TUBING SHALL BE 50 KSI STEEL AND MEETS/EXCEEDS GALVANIZATION PER ASTM A1003/A1003M-15. 5. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 6. ROOF AND WALL SHEATHING SECURED WITH #12-141" SELF -DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 7. FIELD FRAMING CONNECTIONS SECURED WITH #12-14X3/4" SELF -DRILLING SCREWS. B. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. NO WELDING ONSITE. ALL WELDING DONE IN SHOP. 9. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2" DIAMETER & 2,50OLB TENSILE STRENGTH. 10. 12 OR 14GA FRAMING IS 2.5"X2.5" TUBE STEEL NIPPLES ARE 2.25"X2.25" TUBE STEEL. BE TERMRE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION 8 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION INIMUM 2.600 PSI COMPRESSIVE STRENGTH AT 28 DAYS -ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE STRUCTURE GRADE 40 STEEL -REBAR VAPEE-BENT-INSHOP-OR-FIELD PROVIDED: -THE REBAR IS BENT COLD -THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6-BAR DIAMETERS: AND -REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY. -COVER: -2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 1}" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF }" FOR FINE GROUT, AND J" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 11" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY D TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED .Y TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER MESH) AND 12"x12" REINFORCED FOOTER PERIMETER r e m 0 }"44" EXPANSION ANCHOR WITHIN 6" OF EACH POST/TRUSS ALONG SIDES AND EVERY OTHER END -WALL POST 2" MIN. BASE RAIL GRAD 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. OR FIBER MES(2) /MINIMUIM #5 REBAR ®6" O.C. SOIL BEARING CONTINUOUS WITH MINIMUM CAPACITY 2,000 PSF(TYP.) 12" OVERLAP SPLICE CONCRETE FOUNDATION/BASE RAIL ANCHOR DETAIL PLAN VIEW 2 6" DOOR FRAMING RECESS i ^ DOOR WIDTH—-i ELEVATION VIEW DOOR FRAMING RECESS .75"T-DOOR WID OPTIONAL ROLL -UP DOOR CONCRETE SPLASH -GUARD RECESS -118 12"x12" REINFORCED FOOTER I � m `c iv:��yp�sop.pp• 1 '�r� �' y@ i'.. I i i I i i i � I i I i ROLL-FUP DOOR i i i i I O I � o O BUILDING TYPE UTILITY STRUM CONSTRUCTION TYPE II-B RISK CATEGORY 1 FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED ult-165mph EXPOSURE B ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFF. + - 0.18 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD 20PSF OR 30011 FLOOR DEAD LOAD 10PSF FLOOR LIVE LOAD 5OPSF 'R"RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 1840 S0. FT. REwsroNs REV DESCRIPTON DATE DRAWN er: MTB DAME' 2/2/20 LOCanaN: 4606 Magnolia Dr., Ft. Pierce su�- 35'L X 24'W X 1O'H NG Mile REVIEWED FOR ,ODEp ,C/�OMPLIA�►{N��C�E a7T" L�1ClE C®ylyB BOCC /1 7 T 0) L ) ^•^ LLJ 2/4/20 Z MattheW T. BaldWln P.E. Florida License #64608 Sheet CA-1 OF 4 12 Q3 3-441* 3'-44'' [3'-4;1'— CODE INFORMATION 10'-OCODE VERSION FBC 2017 6th Edition ASCE-7-10 •-L°MANUFACTURER CARPORTS ANYWHERE T BUILDING TYPE UTILITY STRUCTURE b b CONSTRUCTION TYPE 11-B RISK CATEGORY I ROLL -UP DOOR FIRE PROTECTION NONE SWINGING FIRE SUPPRESSION SYSTEM NONE DOOR OCCUPANCY UTILITY, U WIND SPEED Vult-165mph EXPOSURE B 7._0• ENCLOSURE ENCLOSED q q INTERNAL PRESSURE COEFF. +/- 0.18 1' 1'- 3'- 3'- `----3'-11{�• 3'-11{5' 3'-11 3'-11 3'-11�0• 3'-11{s' IMPORTANCE FACTOR 1.0 24'-O• 24'_0• ROOF DEAD LOAD 1OPSF FRONT END WALL REAR END WALL ROOF LIVE LOAD 20PSF OR 3001b P.L FLOOR DEAD LOAD IOPSF FLOOR LIVE LOAD 50PSF WRATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE IND SQUARE FOOTAGE 1840 SO. FT. REVISIONS 3'-1C�• 3'-10�' 3'-10�'' REV DESCRIPTON DATE BY -0' ' O.C. MAX o ROLL -UP � DOOR m SWINGING.I OWN W. DOOR MTB mm. 2/2/20 LaGnON: 4606 Magnolia Dr., FL Pierce ,3 10'-0'A - -�• 35'L X 24'W X 10'H 3'_1„8• 3-10� _ 4-� 1'_"f6• 3'_7„3. 3_103. 3_1�.-1 �. 35'-0• LEFT SIDE WALL w ' Q.C. MAX. WINDOW mom( O Q O w 6'-3 Z Lu �e Cop 2/4/20 3-10�' 3'-10�• 3'-1C�• 3-10�' 3'-1Cj• 3-1 Gj' 3.-10j• 3'-10�' w FlotridaWLice Bsed (j64608 31 RIGHT SIDE WALL [Sheet- CA-2 OF 4 DOOOROR Sli' CARPORTSANYWHEM CODE INFORMATioN CODE VERSION FBC 2017 6th Edition CE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II—B RISK CATEGORY I FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY UTILITY, U WIND SPEED Vult-165mph EXPOSURE B ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFF. +/— 0.18 24'-0' I FRONT END WALL I 24'-0' REAR END WALL IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1OPSF ROOF LIVE LOAD OPSF OR 3001b P.1— FLOOR DEAD LOAD 10PSF 0 0 FLOOR LIVE LOAD 5OPSF °R°RATING OF WALLS,FLOOR,ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 840 SO. FT. REVISIONS REV DESCRIPTION DATE BY I ROLL —UP SWINGING DOOR DRAWN H''' MTB DArz: 2/2/20 LOrGOON: 4606 Magnolia Dr., Ft. Pierce ' 35'L X 24'W X 1O'H LEFTSIDEWALL b WINooW 1 o ---------------- RIGHT SIDE WALL bi W_ Z W e C®/4/20 Matthew T. Baldwin P.E. Florida License #64608 Sheet: CA-3 OF 4 f MINIMUM 6' Ts NIPPLE. NIPPLE SECURED O WALL POST WITH (4)#12-14)3' SELF—DRIWNG SCREWS NIPPLE TO BASE RAIL POST TO BASE RAIL CONNECTION MINIMUM 6" Ts NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)y12-144' SELF —DRILLING 2'x2'x2' 16 GA ANGLE CUP SECURED WITH (4) #12-14x1- SELF—DRIWNG SCREWS END POST TO BASE RAIL CONNECTION A. ANGLE CUP SCREWS-14X�" NON—STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL i" SELF—DRIWNG a 10" O.C. MAX., FROM CORNERS TALLY/ 4" MAX. INTERIOR DOOR FRAME TO POST CONNECTION 2"x2"XO 16 GA ANGLE CUP SECURED WITH (4) #12-14)4" SELF—DRIWNG SCREWS 2"x2"x2" 16 GA OR DOUBLE 'IS INTERMEDIATE POST TO HEADER/BASE RAIL/OR HEADER CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1 2"x2"x2" 16 GA. ANGLE CUP SECURED I (44) #12-14)4' SELF —DRILLING SCREWS VARIES STD. MAX. SPACIN 3" MIN. TD. MAX. SP CING VARIES of SIDE WALL ROLL —UP 1 DOOR/FRAME OUT 1 HEADER DETAIL INSTALL PER MANUFACTURERS INSTRUCTIONS #14x1" SELF —DRILLING SCREWS 6 6" O.C. MAIL & 6" MAX. FROM CORNERS ROLL —UP DOOR TO POST CONNECTION DESIGN PRESSURES — 165 Mph ROOF +22.0/-48.4 WALLS +22.8/-25.4 DOORS +22.8/-25.4 WINDOWS +22.8/-25.4 1 2 1 3 4 1 5 ZONE +11.7 —25.8 +14.3 —39.1 +22.0 —48.4 +20.1 —23.8 +22.8 —25.4 26 GAUGE ROOF SHEATHING SECURED WITH (1)k12-14xt' SELF—DRIWNG SCREWS '2-1-2-1' (6' O.C. (9" O.C. MAX.)) 1" 16 GAUGE FURRING CHANNEL 48' O.C. MAX. SECURED WITH SCREWS TO EACELF�NG ROOF PANEL CONNECTION VERTICAL SHEATHING OPTION TO 16 GA U—CHANNEL BRACE, MIN. 24' UP 7' POST, MIN. 48" O\ 7' POST. MIN. 46 TO MAX. 60' FROM HORD MINIMUM 6' Ts NIPPLE NIPPLE SECURED TO WALL POST WITH SC)REWS 144' SELF—DRIWNG BOX EAVE RAFTER TO POST CONNECTION DETAIL 412—MINIMUM 6" TS NIPPLE. NIPPLE SECURED TO WALL POSE WffH /"j MRS A,`n/� MEM —SC)REWS 14x{' SELF—DRIWNG V'�IV�,/ ICI\ 1 j�I�I CLIP ISIM11fl11•AW E'1 HEADER CONNECTION DETAIL occuar C OPTION 2 WIND SPEED rvoncuoc TO MINIMUM 6' Ts NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14X4' SELF—DRIWNG SCREWS POST TO TRUSS APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carports Anywhere FL27402.1—R1 Hampton Rib Roof Panel WALL SHEATHING Carports Anywhere FL27403.1 Hampton Rib Wall Panel SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR ROLL —UP DOOR JANUS INTERNATIONAL CORPORATION FL12765.3—R5 SERIES 3100 WINDOW POCOHONTAS ALUMINUM COMPANY, INC. FL12940—R5 MODEL 100VS IINTERNAL PRESSURE COEFF. I+/— 0.18 1 PER Emi 4606 Magnolia Dr., Ft. Pierce I I� 35'L X 24'W X 10'H m (n 2/4/20 J Q Matthew in P.E Us . Florida License nae 1#64608 Sheet CA-4 OF 4