HomeMy WebLinkAboutSite PlanDesign Parameter, 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category I. 2. Basic Wind Speed, Table 1609C, State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed, V"T= 150 MPH 3. Exposure Category, Paragraph 1609A.3: C Applicable Codes, Regulation and Standards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2 AA ASM 35 and Specifications for Aluminum Structure, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2010 Edition 3. ASCE 7-10 General Notes 1. The contractor shall verify all dimensions pdor to construction 2. All work shall comply with all local and regional ordinances. 3. Any deviaflon from this plan shall be reviewed by the engineer of record and is subject to approval. Specifications The following specifications are applicable to this projects 1. Where concrete specification are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable. 1.1. Concrete shall conform to ASTM C04 for following components: 1.1.1. Portland Cement Type 1, -ASTM C 150 1.1.2. Aggregate - Large Aggregate 3/4" max - ASTM C 33 1.1.3. Air entraining +/-1%-ASTM C 260 1.1.4. Water reducing agent-ASTM C 494 1.1.5. Clean Potable water 1.1.6. Other admixture not permitted 1.2. Metal accessories shall conform to: 1.2.1. Reinforcing Bars - ASTM A615, grade 60 1.2.2. Welded wire fabric-ASTM At 85 1.3. Concrete slump at discharge per chute not less then 3" or more than 5". Water added after batching is not permitted. 1.4. Prepare and place concrete per American Concrete Institute Manual o1 Standard Pmcfice, Parts 1, 2 and 3 including hot weather recommendation: 1.5. Moist cure or polyethylene curing required. 1.6. Prior to placing concrete, treat the engre subsurface area for termites in compliance with the FBC. 1.7. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 1.8. Fiber reinforced concrete per ASTSM C1116 is an acceptable alternative to 6X6 W1.4/W1.4 WWF. 2 Aluminum extrusions shall be 6005 T5 Alloy. 3. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plate to ASTM B633, or stainless steel series "300". 4. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from end 24" on center or 012 screws 6" from end 12" on center. 5. Screened enclosures containing swimming pools shall comply with the applicable requirements of FBC R4501.17 Residential Swimming Barrier requirements, 6. Door location shall be determined by contractor In the field. 7. When installing pavers over concrete slab or fooling which are supporting aluminum members, such as continuous screen tracks or upright, the anchors must extend past the pavers and reach proper embedment into the underlying foundation. 8. All flashing and waterproofing shall be provided by the contractor. 9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. 10. Vinyl and acrylic panels shall be removed when wind speeds exceed 75mph Foundation Design: Existing 8"Idl" Footing Existing concrete. No additional concrete footing Is required to resist the loads imposec by the proposed construction if the existing footing Is In sound Condition, free from structural cracking, spelling, or other deterioration. Roof Type Screen Size None 18/14 HOI2AWSECTIONS aev,xa rvb erAml3mnl ,Hero ram 2.a r' 'x0.W tx<SNS: Yxx•%SAH•x Y.tOP irS pFS: Sx3.15• 2x3: Yx r x MOW xx56NS: YxS x0.050•v BdOtl' S.rSPFS, Yx5.75' 2x4: YxPxO.OW 2x5SMS: Yx5•x0AWx01ar CO a 2x5: 7x5•x055(r 2x75Nfi YxrxMrr%(Xa•xrx0.lxr 2xeaMa: Yx Tx0.o7Yx 0.1a• axe: a•xT.0.1IS, OPENBACKSECTIONS 2xp SMa TWXOCO .M124• exa 5•xra0.12S MINIMUM FASTENER SPACING: YP RI REM CHANNe CONCREre SCREWANCHOR: SHEETMATELSCREwS(SMS)' SMPSON TREK He OR EOuNA W MBURDEx OR EOUNA NOTE: THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES. DRAWING NOT TO SCALE, USE DIMENSIONS GIVEN. CABLE BRACING MAY TERMINATE AT SLAB IN DIFFERENT LOCATION. MAINTAIN ANGLE PER DETAIL I 11'-0"-� PLAN VIEW FRONT ELEVATION 00°°u - � gv0000 U. CC8 0 O 0000���®�noa000eo�p°p°O°°°o° I 0 I I 0 C0 C C H J , ■i A 9 M AN �- REVIEWED FOR L y = 2 CODE COMPLIANCE a y 10 a ST. LUCIE CODUN�TY m mLL o BOCC / r,`.' 1 a N l� File CQco-v SHEET —NOTE- NOT ALL DETAILS ARE USED FOR THIS PROJECT. SEE PLAN FOR DETAIL CALL OUTS"' � ^ oOppppppp000Qppe,7 Q �00�0 � oOQQO o00 o ®� o y o O G �e CHAIR RAIL CHcco AIR o ® u 00 o g9 y 00 a y 2'x2'z 113'ANGLE NTIH (2)E1D% QQ QQ a'� QQOoaaOQO��p�ppQQo00 SIDE(TYP) EACHFLANGE, EACH N 612XSI4'SMS EACH FLANGE (4) m N w (4) x 1- 6MSCNTO URLtN f GIRTf CHAIR RAIL CR O SCREW BOSSES (iYP) a � e aB TO 1 0 F�1 MH114-DIA. ONCR O W C T ENDSCONAND2e O. .1.1W MIN. CONCRETE EIVIBE.. ENT.MIN. PAVE R AR EMBEDMENT. DRILL DRILL 001 SNAP OR Y. N THROU HTOGESENT, THROUGH TO GET MIN 0 0 SELF-MATIN BEAM ONLY 1"�1 W �.S EMBEDMENTINTO FOUNDATION. WOOD. o C.7 C BASE BASE 610x3'WOODSCREWDS S'FROM as W EN0.4S1GONC, r, n CONC.VC DW SCREW W Q b d O b � ANCHOR TROM ENDSRETE ANCHOR ®6'FROM ENDS B 24' O.C. W y • t > FRONT VIEW SIDE VIEW (~�/]I W 3 B-4 SUBPOST CONNECTION M-1 PURLIN /GIRT / O.B TO HOST CONNECTION SCALE: NTS� SCALE: NTS 1/e°XVXrANGLE WITH (4)414 x W SMS INTO 0 0 POST O O RICK PAVERS MAY NOT BE PRESENT. FOLLOW ANCHOR MINIMUM d CONCRETEEMSEDMENT C m H N �w C13 a LL �m s m LL m SIDE VIEW PER PI-ANL gr U) V ANCHOR EDTO V O d CONCR. WTHmm.1- ifd° DIA ^ a a ANCHOR (2vo.c. 11 li Q h r0+ EMBED)024'O.C. MBED) m LL s o 4)II14z3/4•SMS INTD d POST . d .. .. d 1)&e"MWNO ANCHOR. EMBED MIN. 21n^ FRONT VIEW DOTING. SEE PLAN FOR DETAILS Miopr- �j- � SHEET DJ-1 DOORJAMB CONNECTION 2 SCALE: NTS2