HomeMy WebLinkAboutLetter3931 SW 47 Ave. 4104
Davie, FL 33314
Tel: 954-584-6115
E-mail: =Iertoftoilpmbemet
August 29, 2019
American Foundation, Inc.
10780 NW 138th St. #D6
Hialeah Gardens, FL 330
RE: Pile Installation Certification
Proposed Residence
4500 N Hwy. AlA
Fort Pierce, FL
Soilprobe Engineering & Testing, Inc. has completed field observation of auger cast piles
installation for the above referenced project. Piling operation was conducted by American
Foundation corresponding to the date of August 19, and 20, 2019 and installation witnessed by a
representative of this office. The purpose of this site inspections was to observe and document
pile installation operation only.
A total number of forty seven (47) piles were placed at locations staked in the field by the
owner's representative and to depths as indicated in the attached field inspection logs. Pile
installation data for each pile are presented in the attached field installation logs.
Following our observation of pile installation operation at the, scheduled time, and our
knowledge of project documents we certify that the referenced piles were adequately installed
for achieving an allowable bearing capacity of 40 tons compression and 12 tons tension
respectively.
Sincerely,
SoilpyAe Engineering & Testing, Inc.
_ LIg
l
Enc.
N5.37334
Pile installation logs
Location sketches
File Cop
SOILPROBE ENGINEERING AND TESTING, INC.
1611 Auger Cast Pile Log
PROJECT: PROPOSED TWO-STORY RESIDENCE & Contractor: SION HOMES Grout Spec's Load Bearing (tons)
POOL ILogged By: AO 5000 psi
SOILPROBE ENGINEERING & 40 comp
TESTING, INC. ADDRESS: 4500 N Hwy AIA Misc. Info:
Engineers Sign and Seal: 12 tension
CITY: Fort Pierce, FL
Field Notes: Lot#9
Steel Specs: Auger Cast Pile With (6) #6 full length bars with #3 ties @4" O.C. @ top of pile and @10" O.C. @ balance
Pile I.D.
Auger
Time
MIN.
Depth
(feet)
Theorical
Grout Am't
C.Y.
Strokes Pump
Actual
Grout Amt.
C.Y.
Grout
Factor
Ki s
P
comp tension
Date: August 19, 2019
Notes
1
1
2:43
30
1.50
100
2.15
1.43
80
24
Start 1:18 Arrived 12:50
2
2
2:32
30
1.50
110
2.37
1.58
80
24
ADONEL #7019 9 cy
3
3
2:33
30
1.50
108
2.32
1.55
80
24
4
4
2:38
30
1 1.50 -
100
2.15
1.43
80
24
Stop 1:54
5
5
2:29
30
1.50
99
2.13
1.42
80
24
IStart 2:51 Arrived 2:47
6
6
2:31
30
1.50
100
2.15
1.43
80
24
ADONEL #7018 9 cy
7
7
2:35
30
1.50
98
2.11
1.40
80
24
8
8
2:59
30
1.50
105 -
2.26
1.51
80
24
9
9
2:36
30
1.50
102
2.19
1.46
80
24
Stop 3:30 Start 3:31
10
1 10
3:45
30
1.50
109
2.34
1.56
80
24
ADONEL #7017 Arrived 3:05
11
11
2:50
30
1.50
1 100
2.15
1.43
80
24
9 cy
12
12
2:38
30
1.50
102
2.19
1.46
80
24
13
13
2:37
30
1.50
112
2.41
1.61
80
24
Stop 4:13
14
14
2:31
30
1.50
105
2.26
1.51
80
24
Start 4:21 Arrived 3:53
15
15
2:50
30
1.50
107
2.30
1.53
80
24
ADONEL #8000 9 cy
16
16
3:00
30
1.50
ill
2.39
1.59
80
24
17
17
3:21
30
1.50
98
1 2.11
1.40
80
24
Stop 5:25
18
18
2:24
30
1 1.50
106
2.28
1.52
80
24
Start 5:29 Arrived 5:20
19
19
3:00
30
1.50
102
2.19
1.46
80
1 24
JADONEL #8001 9 cy
20
20
2:50
30
1.50
107
2.30
1.53
1 80
1 24
IStop _ 6:00
Pag.:1/3
SOILPROBE ENGINEERING AND TESTING, INC.
1611 Auger Cast Pile Log
PROJECT: PROPOSED TWO-STORY RESIDENCE & Contractor: SION HOMES Grout Spec's Load Bearing (tons)
POOL ILogged By: AO 5000 psi
S011XROBE ENGINEERING & - 40 comp
TESTING, INC. ADDRESS: 4S00 N Hwy A1A Misc. Info:
Engineers Sign and Seal: 12 tension
CITY: Fort Pierce, FL
Field Notes: Lot #9
Steel Spec's: Auger Cast Pile With (6) #6 full length bars with #3 ties @4" O.C. @ top of pile and @10" O.C. @ balance
Pile I.D.
Auger
Time
MIN.
Depth
(feet)
Theorical
Grout Am't
C.Y.
Pump
Strokes
Actual
Grout Amt.
C.Y.
Grout
Factor
Kips
comp tension
Date: August 20, 2019
Notes
1
21
2:43
30
1.50
100
2.20
1.47
80
24
Start 7:06 Arrived 7:00
2
22
2:32
30
1.50
101
2.22
1.48
80
24
ADONEL #8000 9 cy
3
23
2:21
30
1.50
98
2.16
1.44
80
24
4 1
24
2:27
30
1.50
1 99
2.18
1 1.45
80
24
5
25
2:25
30
1.50
124
2.73
1.82
80
24
Stop 7:56 Start 7:56
6
26
2:43
30
1.50
107
2.35
1.57
80
24
ADONEL #7014 Arrived 7:50
7
27
2:33
30
1.50
112
2.46
1.64
80
24
Test taken 9 cy
8
28
2:50
30
1.50
110
2.42
1.61
80
24
Stop 8:35
9
29
2:34
30
1.50
105
2.31
1.54
80
24
Start 9:16 Arrived 8:24
10
30
2:30
30
1.50
100
2.20
1.47
80
24
ADONEL #4009 9 cy
11
1 31
2:21
30
1.50
1 102
2.24
1 1.50
80
24
12
32
2:30
30
1.50
110
2.42
1.61
80
24
13
33
2:35
30
1.50
140
3.08
2.05
So
24
Stop 10:36 Start 10:36
14
34
3:00
30
1.50
100
2.20
1.47
80
24
ADONEL #7012 Arrived 10:22
15
35
2:46
30
1.50
99
2.18
1.45
80
24
9 cy
16
36
2:48
1 30
1.50
98
2.16
1.44
80
24
17
37
2:40
30
1.50
100
2.20
1.47
80
24
Stop 11:18 Start 11:19
18
1 38
2:58
30
1.50
98
2.16
1.44
80
24
ADONEL #8000 Arrived 10:48
19
39
2:38
30
1.50
100
1 2.20
1.47
80
1 24
1 9 cy
20
1 40
2:46
30
1.50
102
1 2.24
1.50
80
1 24
I
Pag.: 2/3
SOILPROBE ENGINEERING AND TESTING, INC.
16" Auger Cast Pile Log
PROPOSED TWO-STORY RESIDENCE & Contractor: SION HOMES Grout Spec's
PROJECT: Load Bearing (tons)
POOL Logged By: AO 5000 psi
SfIILPROBE ENGINEERING & 40 comp
�TE$TLNG,'INC. ADDRESS: 4500 N Hwy AIA Misc. Info:
Engineers Sign and Seal: 12 tension
CITY: Fort Pierce, FL
= Field Notes: Lot #9
Steel Spec's: Auger Cast Pile With (6) #6 full length bars with #3 ties @4" O.C. @ top of pile and @10" O.C. @ balance
'
Pile I.D.
Auger
Time
MIN.
Depth
(feet)
Theorical
GroutAnn't
C.Y.
Pump
Strokes
Actual
GroutAmt.
C.Y.
Grout
Factor
IO ps
comp tension
Date: - August 20, 2019
Notes
1
41
2:27
30
1.50
98
2.16
1.44
80
24
Stop 12:18 Start 12:18
2
42
2:33
30
1.50
105
2.31
1.54
80
24
ADONEL 97004 Arrived 11:00
3
43
2:34
30
1.50
115
2.53
1.69
so
24
9 Cy
4
44
2:34
30
1.50
110
2.42
1.61
80
24
Stop 12:47
5
1 45
2:28
30
1.50
1 110
2.42
1.61
80
24
Start 1:46 Arrived 1:10
6
46
2:47
30
1.50
98
2.16
1 1.44
80
24
ADONEL #7011 9 cy
7
47
2:43
30
1.50
99
2.18
1.45
80
24
Stop 2:30
8
9
10
11
12
13
14
15
16
17
18
19
20
Pag.: 3/3
sane
I
I
3
\
Y
� M
' p
LOT 9 I
2
.�
14,
zags
4Bf2 P?
I
4
-
�
1T" 9
,tW
I� TfLM
-rash I
8 6� I
9
\1
qtQ
d
d
I
�
27
I
20
LOT 9
tiJ
SOILPROBE ENGINEERING AND
He Location Sketch
TESTING
American Foundation
Lot 99
3931 SW 47" Ave. #104
4500 N Hwy AIA
Davie, Fl, 33314
Fort Pierce, FL
Tel. (954) 584-6115
AUGER -CAST PILE LAYOUT
ryc a V
SOILPROBE ENGINEERING AND
Pile Location Sketch
TESTING
American Foundation
Lot #9
3931 SW 4r Ave. #104
4500 N Hwy AlA
Davie, FL 33314
Fort Pierce, FL