Loading...
HomeMy WebLinkAbout35 Sovereign Way window_ CD 1.1_ signedGSPublisherVersion 0.0.100.100 ............................. .. .. .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F F LOO E RTI DAT AS R T E C G EISTITHERCER D A AR97108 A-1 Layout 4/15/20 ID DA T E CO M M E N T FL De s i g n Bu i l d In s p e c t Co n s t r u c t i o n + Ar c h i t e c t u r e + Ho m e In s p e c t i o n CR C 13 3 1 2 6 3 | AA 26 0 0 3 1 4 2 | HI 10 7 7 6 77 2 .32 1 .45 0 0 fr a n k .li e b l e r @ gm a i l .co m ww w .FL D e s i g n B u l i d I n s p e c t .co m © AL L ID E A S , DE S I G N S , PL A N S AN D AR R A N G E M E N T S IN D I C A T E D ON TH I S SH E E T AR E TH E PR O P E R T Y OF FL DE S I G N BU I L D IN S P E C T , AN D WE R E CR E A T E D , EV O L V E D AN D DE V E L O P E D FO R TH I S SP E C I F I C PR O J E C T . NE W WI N D O W OP E N I N G 35 So v e r e i g n Wa y , Fo r t Pi e r c e , FL 34 9 4 9 S H E E T A-1 GN-1 Layout gen notes ID ACTUAL  PRESSURES W H B.O.  LINTEL  LINTEL TYPE RENO STATUS W1 +35.7,‐38.7 8‐11 4‐2 6‐8 NEW H.SLIDER NEW OPENING WINDOW/ LINTEL SCHEDULE SEE GEN NOTE 26 W1: MODIFY EXTG 3-0x4-2 WINDOW OPENING TO BE 8-11x4-2 EXTG EX T G TYP EXTG 2x6 BRG EXT WALLEXTG 2x6 BRG INT WALL EXTG 2x4 NON BRG INT WALL EXTG OFFICE ITEM TYPE ID 1 BUILDING DP 2 PRODUCT DP GLASS  TYPE 5 MFR MODEL APPROVAL # FASTNERS 6 WINDOW H. Slider ALL 59,‐59 IMPACT PGT HR 7710A NOA 18‐0627.01 FRANK LIEBLER, ARCHITECT (AR97108) PRODUCT APPROVAL AFFIDAVIT 1. 'ID' as per door & window schedule, or all meaning worst case of all similar items of that type. 2. If building dp are left blank‐ see door & window schedule or design pressure chart. 3. This affidavit is only to verify product's compliance with wind loads. 4. Unless products are specifically submitted for verification by contractor, they are assumed. 5. If glass type is not specified more than 'impact', may use any of the impact glass type in the install instructions to achieve the stated building design pressures. 6. If fasteners is left blank, may use any of the specified attachment methods in the install instruction matching structure provided to achieve the stated building design pressures. 7. I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. 8' 1' - 4 " 8' 4' - 2 " 8'-11" NEW SILL: (2) 2x6 NEW LINTEL: 3 PLY 5-1/4"W x 11- 7/8"H 1.9E LVL, LAMINATE W/ 2 ROWS OF 16D @ 12" OC EXTG WALL: STUCCO OVER WRB OVER 1/2" PLY OVER 2x6 @ 16" OC W/ R13 BATT. MATCH THESE SPECS FOR MODIFIED AREAS AS NEEDED. SEE GEN NOTE 34.2 FOR NEW LATH, SEE GEN NOTE 22.3 FOR NEW PLY. NEW WINDOW W1, FLASHING AND SEALING AS PER GEN NOTE 26.7 KING TO EXTG FTG W/ S. HDU4-SDS2.5, 5/8" AB W/ 12" EPOXY EMBED LINTEL TO EA JACK POST W/ S. MSTA18 EXTG ROOF: ASPHALT SHINGLE OVER PE TRUSS EXTG FLOOR: CARPET OVER PLY OVER 16" PE TRUSS LINTEL TO EXTG TP W/ SPH6 @ 16" OC KING TO TP W/ SPH6 @ 16" OC SILL TO END W/ (2) S. A23 EXTG 2ND LEVEL EXTG 1ST LEVEL (INTERIOR) NEW JACK POST: (3) 2x6 #2 SYP. LAMINATE W/ 2 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. SHEET INDEX FLOOR PLAN SCALE: 1/4"= 1'-0" WALL SECTION SCALE: 1/2"= 1'-0" WALL FRAMING ELEV SCALE: 1/2"= 1'-0" PROJECT DESCRIPTION ENLARGE EXTG WINDOW OPENING IN 1ST LEVEL FRAME WALL. ZONING INFORMATION: parcel id: 1414-701-0072-000-1 RS-4 unincorporated St Lucie County DocuSign Envelope ID: 816A7E3C-1D54-43AC-9784-11D9A408860D 4/21/2020 GSPublisherVersion 0.0.100.100 ............................. .. .. .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . F F LOO E RTI DAT AS R T E C G EISTITHERCER D A AR97108 GN-1 gen notes 4/15/20 ID DA T E CO M M E N T FL De s i g n Bu i l d In s p e c t Co n s t r u c t i o n + Ar c h i t e c t u r e + Ho m e In s p e c t i o n CR C 13 3 1 2 6 3 | AA 26 0 0 3 1 4 2 | HI 10 7 7 6 77 2 .32 1 .45 0 0 fr a n k .li e b l e r @ gm a i l .co m ww w .FL D e s i g n B u l i d I n s p e c t .co m © AL L ID E A S , DE S I G N S , PL A N S AN D AR R A N G E M E N T S IN D I C A T E D ON TH I S SH E E T AR E TH E PR O P E R T Y OF FL DE S I G N BU I L D IN S P E C T , AN D WE R E CR E A T E D , EV O L V E D AN D DE V E L O P E D FO R TH I S SP E C I F I C PR O J E C T . NE W WI N D O W OP E N I N G 35 So v e r e i g n Wa y , Fo r t Pi e r c e , FL 34 9 4 9 S H E E T COMPONENT AND CLADDING LOADS… FROM TABLE FBC R301.2(2) EFFECTIVE WIND AREA (SF) 4 10.0 35.7 ‐38.7 4 20.0 34.1 ‐36.1 4 50.0 31.9 ‐34.8 4 100.0 30.3 ‐32.3 4 500.0 26.6 ‐28.4 5 10.0 35.7 ‐47.7 5 20.0 34.1 ‐43.9 5 50.0 31.9 ‐40.0 5 100.0 30.3 ‐36.1 5 500.0 26.6 ‐28.4 1.29 adjustment factor used Wall ZONE 160 WIND PRESSURES (asd) BASIS OF STRUCTURAL DESIGN: SOIL BEARING: 2500 psf (assumed) WIND: 160mph (ultimate), risk category 2, exposure C, wind borne debri region, .18 enclosed design FROST DEPTH: 12" - THE STRUCTURAL DESIGN APPROACH FOR MASONRY, ROLLED STEEL, AND LIGHT WEIGHT STEEL IS WORKING STRESS DESIGN. THE DESIGN APPROACH FOR REINFORCED CONCRETE IS ULTIMATE STRENGTH DESIGN. THE DESIGN SERVICE LOADS ARE AS FOLLOWS: ROOF LIVE LOAD 20 PSF(slope<4:12), 15 PSF(slope≥4:12) ROOF DEAD LOAD 10 PSF TC ROOF WIND LOAD (SEE DRAWINGS) CEILING DEAD LOAD 10 PSF BC WALL WIND LOADS (SEE DRAWINGS) FLOOR DEAD LOADS 15 PSF TC, 5 PSF BC FLOOR LIVE LOADS SEE BELOW FLOOR LIVE LOADS: Uninhabitable attics without storage 10 psf Uninhabitable attics with limited storage 20 psf Habitable attics and attics served with fixed stairs 30 psf Balconies (exterior) and decks 40 psf Fire escapes 40 psf Guardrails and handrails 200 lb Guardrail in-fill components 50 plf Passenger vehicle garages 50 psf Rooms other than sleeping room 40 psf Sleeping rooms 30 psf Stairs 40 psf 1. CODE COMPLIANCE: 1.1. This project was designed under the following codes. The construction documents cannot reference all of the codes require for the construction of this building. By submitting these construction documents for permit or commencing work, the contractor, hereby agrees to comply with all local, state, and federal regulations having jurisdiction over this project, and to comply with all governing codes, including but not limited to, the most current editions as adopted by the state of Florida, of the following: 2017 FBC: RESIDENTIAL, 6th ed 2017 FBC: ENERGY CONSERVATION, 6th ed 2014 NATIONAL ELECTRIC CODE 2. ALL GENERAL NOTES 2.1. THE FOLLOWING SPECIFICATIONS ARE MINIMUM REQUIREMENTS TO SUPPLEMENT THE DRAWINGS. IN CASE OF CONFLICT, NOTIFY ARCHITECT. THESE DRAWINGS, IN CONJUNCTION WITH OTHER SUBMITTALS, REPORTS, OR WRITTEN INSTRUCTIONS BY ARCHITECT OR CONSULTANTS, SHALL BE CONSIDERED THE COMPLETE CONSTRUCTION DOCUMENTS. 2.2. THE FOLLOWING GENERAL & SPECIFIC NOTES SHALL APPLY EQUALLY TO ALL CONTRACTORS , SUBCONTRACTORS, AND SUPPLIERS ENGAGED IN EXECUTION OF WORK ON THESE PLANS. 2.3. GENERAL CONTRACTOR SHALL FURNISH A COMPLETE SET OF DRAWINGS AND ADDENDUM'S TO ALL SUBCONTRACTORS ON THE JOB AND COORDINATE THEIR WORK. ANY DISCREPANCIES AND/OR CONFLICTS IN THE DRAWINGS SHALL BE NOTIFIED TO THE ARCHITECT BEFORE PROCEEDING WITH ANY INSTALLATION. FAILURE TO DO SO WILL BE THE ENTIRE RESPONSIBILITY OF THE GENERAL CONTRACTOR. ANY COSTS ARISING TO CORRECT THE DISCREPANCY AND/OR CONFLICT SHALL BE BORNE BY THE RESPONSIBLE PARTY. 2.4. NO DEVIATION OF THE APPROVED SET OF DRAWINGS WILL BE MADE IN THE FIELD WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT AND BUILDING OFFICIAL. IN SUCH CASE THE ARCHITECT SHALL PREPARE A REVISION IN ACCORDANCE WITH THE CHANGE. APPROVAL FROM THE BUILDING OFFICIAL SHALL BE OBTAINED BY THE CONTRACTOR BEFORE PROCEEDING WITH ANY WORK. 3. ARCHITECT & CONTRACTOR RELATIONSHIP 3.1. UNLESS CONTRACTED DIRECTLY BY CONTRACTOR, THE ARCHITECT AND CONTRACTOR ARE NOT IN A CONTRACTUAL RELATIONSHIP, THE ARCHITECT IS AN AGENT OF THE OWNER. BY SUBMITTING THESE CONSTRUCTION DOCUMENTS FOR PERMIT, THE CONTRACTOR ACKNOWLEDGES THAT THEY ARE COMPETENT, UNDERSTAND THE DOCUMENTS, AND ARE BOUND BY THE TERMS OF THE DOCUMENTS. IF THE CONTRACTOR VEERS FROM THESE PLANS, THEY ARE ACCEPTING LIABILITY THAT MAY ARISE DUE TO CHANGES. ARCHITECT IS NOT LIABLE FOR THE CONTRACTOR’S INCOMPETENCY TO UNDERSTAND THE CONSTRUCTION DOCUMENTS. IT IS NOT THE ARCHITECT'S ERROR OR OMISSION IF THE ARCHITECT DOES NOT SPECIFY/REFERENCE SOMETHING THAT IS REQUIRED BY THE CODES MENTIONED, THE CONTRACTOR AND SUBS ARE REQUIRED TO UNDERSTAND AND ADHERE THE BLDG CODES NO DIFFERENT THAN THE ARCHITECT. 4. WORKMANSHIP: 4.1. ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY CRAFTSMEN SKILLED IN THEIR RESPECTIVE TRADES. 5. COORDINATION: 5.1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF WORK FOR ALL TRADES. 5.2. A DRAWING MAY INADVERTENTLY OMIT SOME RELATED ITEM FROM ANOTHER DRAWING. THIS DOES NOT MEAN THAT THE SECONDARILY OMITTED ITEM IS NOT REQUIRED IN SO FAR AS IT AFFECTS THE TRADES. ALL TRADES SHALL INCLUDE EVERYTHING NECESSARY FOR A COMPLETE AND PROPERLY FUNCTIONING CODE - ACCEPTABLE PROJECT, UNLESS CERTAIN ITEMS ARE SPECIFICALLY INDICATED AS BEING PROVIDED BY OTHERS AS "NIC" (NOT IN CONTRACT). 6. ABBREVIATIONS: 6.1. SEE ABBREVIATION LIST FOR DEFINITIONS WHICH ARE USED IN THESE DRAWINGS AND SPECIFICATIONS. 7. CONDITIONS NOT DETAILED: 7.1. CONSTRUCTION DOCUMENTS CANNOT DETAIL EVERY CONDITION OR INSTRUCT THE CONTRACTOR ON HOW TO PERFORM THE WORK. EVERY CONNECTION, CORNER, FLASHING, ETC. MUST BE RESOLVED. NOTIFY ARCHITECT IF A CONDITION NEEDS ADDITIONAL DIRECTION OR DETAIL. ARCHITECT IS NOT LIABLE FOR WORK THAT IS NOT DETAILED/SPECIFIED BY ARCHITECT. IF DRAWINGS HAVE A DETAILED SPECIFICATION FOR A CERTAIN PRODUCT , CONTRACTOR MAY REQUEST A SUBSTITUTION APPROVAL BY ARCHITECT . IF DRAWINGS HAVE A GENERIC SPECIFICATION CONTRACTOR IS FREE TO USE ANY PRODUCT THAT MEETS WHAT IS SPECIFIED WITHOUT APPROVAL BY ARCHITECT. 8. VERIFY SITE INFORMATION: 8.1. CONTRACTOR IS TO VERIFY ALL SITE INFORMATION AND ASSUMPTIONS, ESPECIALLY SUBTERRANEAN CONCEALED CONDITIONS INVOLVING HIDDEN UTILITIES AND SOIL CONDITIONS. SHOULD ANY CONDITIONS AFFECTING THE WORK BE DISCOVERED BY THE CONTRACTOR, HE IS TO NOTIFY THE ARCHITECT IMMEDIATELY. CONTRACTOR SHALL VERIFY THAT EXISTING SOILS MEET THE MINIMUM CAPACITY PER THE STRUCTURAL DESIGN. 9. PRIOR TO ANY EXCAVATION WORK : 9.1. THE CONTRACTOR IS REQUIRED TO LOCATE ANY AND ALL UTILITIES IN OR UNDER CONSTRUCTION, AND MAKE ARRANGEMENTS FOR THEIR LEGAL RE-ROUTING, AS ACCEPTABLE TO GOVERNING AGENCIES, AUTHORITIES, UTILITIES AND OWNER. CONTACT ALL AFFECTED UTILITY COMPANIES AND INFORM THEM OF THE IMPENDING CONSTRUCTION, AND OBTAIN THEIR ASSISTANCE IN LOCATING THEIR UTILITIES. 10. DIMENSIONS: 10.1. DIMENSIONS ON ARCHITECTURAL DRAWINGS MAY BE "ROUGH" OR "FINISH." SEE PLANS FOR REQUIREMENTS. ARCHITECTURAL DIMENSIONS SHALL TAKE PRECEDENCE OVER STRUCTURAL OR OTHER DIMENSIONS, IF NO OTHER CONFLICT RESULTS. DOCUMENT ANY SUCH DISCREPANCIES TO ARCHITECT IN WRITING. DO NOT RELY ON SCALED DIMENSIONS. NOTES TAKE PRECEDENCE OVER GRAPHICS. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS FOR WORK TO EXISITING BUILDINGS. 11. HEIGHT ELEVATIONS: 11.1. BUILDING HEIGHT ELEVATIONS TYPICALLY USE THE MAIN FLOOR SLAB AS ELEVATION 0'-0" (BUILDING ELEVATIONS MAY BE NOTED AS "BLDG EL. __" OR "EL. __" OR "AFF. __”) ANY ELEVATION NOT OTHERWISE DESIGNATED AS A SITE ELEVATION IS ON ANY PLANS OTHER THAN THE SITE PLAN IS ASSUMED TO BE A BUILDING ELEVATION. SITE ELEVATIONS MAY BE BASED ON THE SURVEY, WHICH MAY USE MEAN SEA LEVEL, NAVD, OR OTHER HEIGHT AS A REFERENCE DATUM. SITE ELEVATIONS MAY BE NOTED AS: "SEL __" OR "__ NAVD" OR " +X.X' ". CONSULT ARCHITECT FOR ANY QUESTIONABLE LOCATIONS PRIOR TO CONSTRUCTING. 12. AMBIGUITY: 12.1. IN THE EVENT OF ANY AMBIGUITY OR QUESTION WITH REGARD TO THE INTENT OF THE DOCUMENTS, THE ARCHITECT SHALL INTERPRET THE CONSTRUCTION DOCUMENTS. 12.2. IN CASE OF CONFLICTS BETWEEN ARCHITECTURAL AND STRUCTURAL DRAWINGS, CONSULT WITH ARCHITECT. IN CASE OF CONFLICT BETWEEN THE GENERAL NOTES, SPECIFICATIONS, AND DRAWINGS, CONSULT WITH ARCHITECT . 13. FLORIDA PRODUCT APPROVALS / SUBMITTALS / SHOP DRAWINGS: 13.1. THE SUBMISSION OF REQUIRED NOTICES OF ACCEPTANCE (NOA) / PRODUCT APPROVALS ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS REQUIRED TO MAKE THESE AVAILABLE AT TIME OF INSPECTION. EVEN IF THE ARCHITECT PROVIDES THESE THE CONTRACTOR MAY CHANGE TO A DIFFERENT PRODUCT THAT MEETS THE SAME OR HIGHER BUILDING DESIGN PRESSURES, SOME JURISDICTIONS WILL REQUIRE A REVISION. IF THERE IS A DISCREPANCY BETW THE FASTENING OF PRODUCTS, ACCORDING TO MFR INSTALLATION AND ARCHITECT'S SPECS, VERIFY W/ ARCHITECT. 13.2. SHOP DRAWINGS/SUBMITTALS WILL BE REVIEWED FOR DESIGN CONFORMITY AND GENERAL CONFORMANCE TO CONSTRUCTION DOCUMENTS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT JOBSITE FOR TOLERANCE, CLEARANCE, QUANTITIES, FABRICATION PROCESSES /TECHNIQUES OF CONSTRUCTION, COORDINATION OF HIS WORK WITH OTHER TRADES, AND FULL COMPLIANCE WITH CONSTRUCTION DOCUMENTS. 14. GENERAL STRUCTURAL 14.1. ONCE SIGNED & SEALED BY ARCHITECT OR ENGINEER. DESIGN PROFESSIONAL CERTIFIES THAT THE CONSTRUCTION DOCUMENTS MEET THE LOAD REQUIREMENTS STATED IN THE APPLICABLE FBC REFERENCED. 14.2. THE CONTRACTOR IS RESPONSIBLE FOR ALL METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION. PROVIDE APPROPRIATE SUPERVISION THROUGHOUT THE PROJECT. CONSTRUCTION SITE SAFETY, INCLUDING ALL ADEQUATE TEMPORARY BRACING AND SHORING, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY THE NECESSARY PROFESSIONAL SERVICES TO DETERMINE THE NECESSARY METHODS AND SUPPORTS REGARDING FORMING AND CONSTRUCTION LOADS. TEMPORARY BRACING AND SHORING SHALL BE DESIGNED TO RESIST ALL CONSTRUCTION LOADS INCLUDING THE WEIGHTS OF ALL SUPPORTED MATERIALS PLUS A LIVE LOAD OF 50 PSF ON HORIZONTAL SURFACES. MAINTAIN TEMPORARY BRACING AND RETAIN IN PLACE UNTIL PERMANENT STRUCTURAL SYSTEMS ARE CAPABLE OF RESISTING ALL CONSTRUCTION PHASE LOADS. 14.3. THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND START OF CONSTRUCTION. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ALL CONSTRUCTION AND ITS CONTENTS. 14.4. SPECIFIC PRODUCT DATA MUST BE PROVIDED TO ARCHITECT FOR APPROVAL OF HEAVY FINISHES SUCH AS TILE ROOFS OR STONE ON RAISED FLOORS. 26. EXTERIOR DOORS AND WINDOWS: 26.1. INSTALL OVERHEAD DOORS (INCLUDING BUCKS), EXTERIOR DOORS, AND WINDOWS AS PER MFR'S SPECIFICATION/ PRODUCT APPROVAL. 26.4. CONTRACTOR TO VERIFY THE FOLLOWING WITH MFR/SUPPLIER PRIOR TO CONSTRUCTION: -ROUGH OPENING DIMS, EGRESS COMPLIANCE (FBC R310), SAFETY GLASS COMPLIANCE (FBC R308.4) 26.5. CONTRACTOR TO FIELD VERIFY OPENINGS BEFORE ORDERING DOORS/WINDOWS. 26.7. FLASHING AS PER FBC R703.4 AND REFERENCED FMA/AAMA DOCUMENTS. 26.8. GLASS TO HAVE: LOW-E, U-FACTOR ≤ 0.4, SHGC ≤ 0.25 31. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: 31.1. FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX: 31.2. FINISHES TO COMPLY WITH THE BELOW FIGURES AS PER FBC R302.9 - 302.10 31.3. INSULATION FLAME SPREAD: <25, INSULATION SMOKE DEVELOPED: <450 31.4. WALL/CLG FLAME SPREAD: <200, WALL/CLG SMOKE DEVELOPED: <450 34. FINISHES: 34.1. GWB: MOISTURE RESISTANT GWB @ ALL WET AREAS, CEMENT BOARD INSIDE SHOWER COMPARTMENTS. USE 5/8” TYPE X GWB ON GARAGE CEILING IF CONDITIONED/HABITABLE AREA ABOVE . GARAGE SEPARATION WALL TO HAVE A MINIMUM OF ONE 1/2" LAYER OF GWB ON THE GARAGE SIDE OF WALL AS PER FBC R302.6. SEE DOOR GEN NOTE 26.6. 34.2. EXTERIOR LATH AS PER FBC R703.7.1/ASTM C1063-11A. FOR EXTERIOR CEILINGS/SOFFITS USE MIN. 5/8" STUCCO ON RIBBED LATH. ATTACH TO BOTTOM OF WOOD FRAMING W/ 11GA NAILS W/ 3/8" HEAD @ 6" OC W/ 1-3/4" EMBED INTO WOOD. TYP TRANSITION FROM WOOD TO CONC (I.E. @ GABLE END) TO HAVE A VINYL CONTROL JOINT IN STUCCO. 21. WOOD FRAMING 21.1. ALL STRUCTURAL (LOAD BEARING) LUMBER SHALL BE S.Y.P. OR DOUGLASS FIR, GRADE #2, KD 19% (Fb FOR LUMBER SIZES NOTED TO BE IN CONFORMANCE WITH VALUES LISTED IN THE NATIONAL FOREST PRODUCTS ASSOCIATION NATIONAL DESIGN STANDARD SUPPLEMENT TABLE 4B), AND SHALL CONFORM TO THE NATIONAL GRADING RULE FOR DIMENSION LUMBER, THE SOUTHERN PINE INSPECTION BUREAU AND THE SOUTHERN FOREST PRODUCTS ASSOCIATION. ALL NON-LOAD BEARING FRAMING LUMBER (INTERIOR WALLS) TO BE #2 S.P.F. OR BETTER. 21.2. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE AND/OR MASONRY TO BE PRESSURE TREATED. ALL WOOD EXPOSED TO THE WEATHER OR IN CONTACT WITH THE GROUND TO BE PRESSURE TREATED TO 0.80 CCA. 21.3. SPLICING FOR MULTI-PLY HEADERS /BEAMS/COLUMNS: -2x4- 10d COMMON NAIL @ 6" OC EACH LAYER STAGGERED. -2x6- 2 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x8- 3 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x10- 4 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -2x12- 5 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER. -LOCATE SPLICES OVER BRG SUPPORTS. GLUE BETW LAYERS. USE 16D IF 1/2" PLY SPACER USED 21.4. LAMINATED TIMBER ELEMENTS (BENTS, BEAMS, DECK, ETC., AND ANCILLARY ACCESSORIES, FASTENERS, ETC.: -FABRICATOR TO SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR ALL ELEMENTS OVER SIGNATURE AND SEAL OF FLORIDA ENGINEER (SPECIALTY ENGINEER ) -SPECIALTY ENGINEER MAY SUBMIT CONNECTION DETAILS FOR BENTS AND BEAMS AND FASTENING MODE AND INTERVALS FOR DECK. (CONNECTIONS FOR BEAM-ENDS TO RESIST ROTATION.) 21.5. GLUE-LAMINATED BEAMS (GLULAM) SHALL BE DOUGLAS FIR COMBINATION 24F-V4 AT SIMPLE SPANS AND 24F-V8 AT CANTILEVER SPANS HAVING THE FOLLOWING MINIMUM PROPERTIES: Fb = 2,400 PSI, Fv = 190 PSI, Fc (PERPENDICULAR) = 650 PSI, E = 1,800,000 PSI, FABRICATION AND HANDLING SHALL CONFORM TO THE LATEST AMERICAN INSTITUTE FOR TIMBER CONSTRUCTION (AITC) AND ASTM STANDARDS. BEAMS SHALL BEAR AN APPROPRIATE GRADE STAMP CLEARLY NOTING ITS DESIGN PROPERTIES. UNLESS CAMBER AND TOLERANCE IS SPECIFICALLY NOTED ON THE DRAWINGS, BEAMS SHALL BE MANUFACTURED WITH INDUSTRY STANDARD MINIMUM CAMBER OR UPWARD TO SPAN/200. ERECT WITH CROWN OR CAMBER UP. IN HEADER CONDITIONS (BEAM BUILT INTO WALL) CRIPPLE FRAMING ABOVE HEADER SHALL MAINTAIN CAMBER. HEADER BEAMS MAY HAVE ZERO CAMBER, PROVIDED CRIPPLE FRAMING ABOVE HEADER IS BUILT WITH MINIMUM CAMBER STATED ABOVE. 21.6. LAMINATED LUMBER AND "I" JOISTS AND RAFTERS SHALL BE INSTALLED AS PER MANUFACTURER'S INSTRUCTIONS. 21.7. END STUDS OF EXTERIOR FRAME WALL OR DESIGNATED INTERIOR SHEAR WALLS TO ATTACH TO CONC WALL W/ .25” x 3.25” TAPCON @ 16” OC/8" ENDS. FOR INTERIOR BRG WALLS USE 1/4" x 2.75" TAPCON @ 32" OC/8" ENDS. 21.8. ALL WOOD NAILING AS PER FBC R 602.3 UNO. 22. PLYWOOD SHEATHING: 22.1. ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING. INSTALL PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, PROVIDE BLOCKING AT PANEL EDGES WHERE INDICATED ON THE PLANS. 22.2. UPPER PANELS TO BE ATTACHED TO THE TOP MEMBER OF THE UPPER DOUBLE TOP PLATE AND TO RIM JOIST AT BOTTOM OF WALL. PROVIDE BLOCKING FOR ALL EDGE NAILING OVER LENGTH OF PLYWOOD 22.3. FOR EXTERIOR AND INTERIOR SHEAR WALLS USE 1/2" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 6" EDGE, 4" EDGE WITHIN 4' OF CORNERS. 22.4. FOR ROOF USE 5/8" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 6" EDGE, 4" EDGE WITHIN 4' OF EAVES/RIDGES/GABLES. 22.5. FOR SUBFLOOR USE 3/4" PLYWOOD AND 2.5" #8 SCREWS & GLUE OR 8d RINGSHANK GALV NAILS & GLUE. SPACE FASTENERS 6" FIELD, 6" EDGE. 22.6. FOR ATTIC FLOOR USE 5/8" PLYWOOD AND 6d RINGSHANK GALV NAILS. SPACE NAILS 12" FIELD, 12" EDGE. ONLY ALLOWED WHERE TRUSS ENGINEERING SPECIFIES. GENERAL NOTES- residential ABBREVIATIONS: AB ANCHOR BOLT A/C AIR CONDITIONER AHU AIR HANDLING UNIT AT ACOUSTICAL TILE B.M. BENCH MARK BM BEAM BC BOTTOM CHORD BLK BLOCK BO BY OWNER BOTT BOTTOM BP BOTTOM PLATE CJ CONTROL (CONSTRUCTION) JOINT CL CENTER LINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT CO CONNECTOR COL COLUMN CONC CONCRETE CONT CONTINUOUS CU CONDENSING UNIT OR COPPER CW COLD WATER CXN CONNECTION D NAIL SIZE (PENNY) DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DISP DISPOSAL DN DOWN DR DRYER DTL DETAIL DW DRIVEWAY 'E' EXISTING EA EACH EJ EXPANSION JOINT EL BUILDING ELEVATION ELECT ELECTRICAL ELEV ELEVATOR OR ELEVATION EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXP EXPOSED EXT EXTERIOR EXTG EXISTING F1 FOOTING #1 FA FASTENER FD FIELD (FLOOR) DRAIN FE FIRE EXTINGUISHER FF FINISH FLOOR FIN FINISH FLR FLOOR FP FIRE PROTECTION EPS EXPANDED POLYSTYRENE FTG FOOTING FT FOOT (OR FEET) GALV GALVANIZED GFI GROUND FAULT INDICATOR GSF GROSS SQUARE FEET GWH GAS WATER HEATER GWB GYPSUM WALL BOARD HB HOSE BIB HC HOLLOW CORE HDG HOT DIPPED GALVANIZED HORIZ HORIZONTAL HW HOT WATER HWH HOT WATER HEATER IN INCH INT INTERIOR JT JOINT MAX MAXIMUM MEP MECH/ELECT/PLUMB MFR MANUFACTURER MIN MINIMUM MO MASONRY OPENING MW MICROWAVE NIC NOT IN CONTRACT NTS NOT TO SCALE NSF NET SQUARE FEET L-1 LINTEL #1 LF LINEAL FOOT OA OVERALL OC ON CENTER OAS OR APPROVED SIMILAR PL PROPERTY LINE OR PLATE PLY PLYWOOD PT PRESSURE TREATED PVC POLY VINYL CHLORIDE R RADIUS R/A RETURN AIR RCB REINFORCED CONCRETE BEAM RCC REINFORCED CONCRETE COLUMN RD ROOF DRAIN REF REFRIGERATOR REINF REINFORCING REQ REQUIRED R/W RIGHT-OF-WAY RTU ROOF TOP UNIT S. SIMPSON (MFR) SBS STYRENE BUTADIENE STYRENE SEL SITE ELEVATION SF SQUARE FOOT SIM SIMILAR SK SINK SOG SLAB ON GRADE SS STAINLESS STEEL STAG STAGGERED TBD TO BE DETERMINED TC TOP CHORD TME TO MATCH EXISTING TOB TOP OF BEAM TOB TOP OF COLUMN TOS TOP OF SLAB TP TOP PLATE TPO THERMO PLASTIC OLEFIN TYP TYPICAL UG UNDER GROUND UNO UNLESS NOTED OTHERWISE VB VAPOR BARRIER VERT VERTICAL VTR VENT THRU ROOF W/ WITH WA WASHER MACHINE WP WATER PROOF WD WOOD WWF WELDED WIRE FABRIC/MESH # POUND OR NUMBER DocuSign Envelope ID: 816A7E3C-1D54-43AC-9784-11D9A408860D 4/21/2020