Loading...
HomeMy WebLinkAboutProduct approvalGREEK TECHNICAL SERVICES. LLC G4rtiffcate of Authorbatlon Na 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6r" EDITION (2017) Manufacturer: DREXEL METALS, INC. issued September 14, 2017 Stands M 1234 Gardiner Lane Architecture? Testing (TST1668) Louisville, KY 40213 TAS 100 (502)716-7143 Architectural Testing (TST1558) wwwArexmetcom Manufacturing: Drexel Metals Association of Regional Manufacturers (DM -ARM) Quality Assurance: Architectural Testing, Inc. (QUA1844) SCOPE 2006 Category: Roofing Subcategory: Metal Roofing Code Sections: 1604.3 Properties: Wind Resistance REFERENCES Entity Report No. Stands M Year Architecture? Testing (TST1668) 66840.02-122-18 TAS 100 1995 Architectural Testing (TST1558) 58389.01-122-44 UL 580 2006 Architectural Testing (TST1558) 58459.01.122-04 UL 580 2006 Architectural Testing (TST1558) 58461.01.122.44 TAS 125 2003 Architectural Testing (TST1558) 82776.01-10944 UL 580 2006 UL 1897 2012 Architectural Testing (TST1658) 82784.01.109-04 UL 580 2006 UL 1897 2012 Architectural Testing (TST1558) 63296.01.109-04 UL 580 2006 UL 1897 2012 Force Engineering & Testing (TST5328) 178-0054T-12 UL 580 2006 UL 1897 2012 Force Engineering & Testing (7875328) 178-0055T-12 UL 580 2006 UL 1897 2012 Hurricane Test Laboratory (TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0308-07 TAS 126 2003 Hurricane Test Laboratory (TST1527) 0287-0311.07 TAS 126 2003 Hurricane Test laboratory (TST1527) 0287.0313.07 TAS 125 2003 Hurricane Test laboratory (TST1527) 0287-0612-07 TAS 126 2003 Hurricane Test Laboratory (TST1527) 0287-0706-07 TAS 125 2003 PRI ConslNetion Materials Technologies (TST6878) VLS-005-02-01 ASTM 8117 2016 TAS 110 2000 PRI Construction Materials Technologies (TST5878) VLS.004.0201 ASTM G 156 2006a TAS 110 2000 PRI Construction Materials Technologies (TST5878) DMC -004-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST5878) DMC -005-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST6878) DMC -006-02.01 TAS 125 2003 PRI Construction Materiats Technologies (TST5878) DMC -007.02-01 TAS 100 1995 PRI Constmetion Materials Technologies (TST5878) DMC -008.02-01 TAS 100 1895 PRI Construction Materials Technologles (TST6878) DMC -009-02-01 TAS 100 1895 PRI Corstruction Materials Technologies (TST6878) DMC -014-02-01 TAS 126 2003 PRI Construction Materials Technologies (TST5878) DMC -016.02-01 TAS 100 1895 PRI Construction Materials Technologies (TST5878) DMC -017-02-01 Rev 1 UL 560 2006 UL 1897 2012 PRI Consbuction Materials Technologies (TST5878) DMC -018-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies (TST5878) DMC -024.02-01 UL 580 2006 UL 1897 2012 DRX15001.4 FL17678-R4 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20.3, The manufacturer shall nol8y CREEK Technical Services, LLC of any product changes a quality assurance changes throughout the duration for which this report Is valid. This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. PRODUCT DESCRIPTION DMC 100NS Profile: 1 in. snap lock seam; Max.16In. coverage _ Description: Non-structural, snap lack standing seam roof panel with integral perorated nail strip _ DRE%EL METALS, INC. CREEK Metal Rooting TECHNICAL SERVICES, LLC -- v /• Entity Report No Standa Year PRI Construction Materials Technologies (TST5878) DMC -033-02-01.1 UL 580 2006 Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or UL 1897 2012 PRI Construction Materials Technologies (TST5878) DMC -037-02.01 UL 580 2006 DMC 16OSS Profile: UL 1897 2012 PRI Construction Materials Technologies (TST5878) DMC.037-02-02 UL 680 2006 Min. 0.032 In. Flumpon® coated ASTM B209 aluminum; Fy = min. 16 ksl; Shall UL 1897 2012 PRI Construction Materials Technologies (TST5878) DMC -038.02-01 UL 550 2006 r1 UL 1897 2012 PRODUCT DESCRIPTION DMC 100NS Profile: 1 in. snap lock seam; Max.16In. coverage _ Description: Non-structural, snap lack standing seam roof panel with integral perorated nail strip _ _ Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ60, or ASTM A663 G90; F„ = min._ 50 ks); Shall conform wftim FOC Section 1607.4.3 -- v /• DMC 1 60S Profile: 1.5 in. snap lock seam; Max. 16 in. coverage Non-structural, snap lock standing seam roof panel Description: Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90; Fy . min. 60 ksl; Shall conform WM FBC Section 1507.4.3 T— DMC 16OSS Profile: 1.5 In, mechanical seam; Max. 16 in. coverage_ Description: Non-structural, mechanical lock standing seam roof panel Materlai: Min. 0.032 In. Flumpon® coated ASTM B209 aluminum; Fy = min. 16 ksl; Shall conform with FBC Section 1507.4.3 _ Min. 24 ga. FluroponO coated ASTM A792 AZ50, or ASTM A663 G90; Fr = min. 50 k9); Shall conform with FBC Section 1507.4.3 r1 f.6 I, 12 -T 7 FL17678-R4 2 of This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes a quality assurance changes throughout the duration forwhich this report Is valid. This evaluation report does not express nor Imply waranty, installation, recommended use, or other product alhibutes that aro no specl0catly addressed herein. GREEK TECHNICAL SERVICES. LLC DREXEL METALS, INC. Metal Roofing APPENDIX A Component Product Installation Detail DMC 1OONS PANEL - 18 ga. base; 22 ga. butterfly Inseam clip; 120 in. length; top slider 121n. o.c. #10 - 13 PHW DMC 2005 Continuous 1` V Butterfly Clip Clips (Cont'd) DMC 100NS Enhanced 24 ga. Inseam clip DMC 450 Clip e ®� 24 ga. SS Inseam clip DMC 45085 Clip Sealants Soalik 70-05A Shall be applied In continuous beads along the seam Bostik Chem -Calk 815 Fastening Details Nomenclature Attachment DMC 1OONS PANEL - #10 - 13 PHW OMC 700NS Standard 1 DMC 10ONS PANEL BOSTIK 70-05A (2 - 3/16" BEADS) DMC 100NS Enhanced #10 - 13 P H W This evaluation report Is provided for State of Florida product approval under Rule 81G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance charges throughout the duration for which this report is valid. This evaluation report does not express nor imply wananty, installation, recommended use, or other product attributes that are not speci0cally addressed herein. m a Z y Q^, R. N G V J R' Q d _ $ m a i € W o o E�� c Puj �� L 2 o@ (n C U O m a v O59 d C €,fig S e S 3� ,p6 md V 6V doe Q' m jS E' .5 E Z w m e a�C C 3q 7' •p� O J N d gEC 2' W a Hf A HS LLUJY aE �c)ro Eaaaa i f 4� �N �D.OLL LL ill����aaaa'a p �:4 2TO0 � o lZI�z� E M. @ d� @@CEO @@ ��y�y}�'$S&.YvNiEO �m UpLLpNc �C or•�yy��``5bCpCp pp6 3Ney0 02 ooNgiomo� � REimerNNp� V Q aJala/I N N ib ��• � � p UUU U U u Q U UUU •� 24 a � 4 U oo6.z o$^ ff�f f:f��f og of gt LL� vg. „3 cpoc cc0000 C a a �vq � cc -'s � p o1 o1 +y 2 N .N�€ y23JN IwN NO33 �N �3 g3 Y >5S >6 yi> NG NE f o °csng �HQ-raL " N1d £6+ CW@g ��Q1Ym $K X .��{� Nc E y g8 �U �SWo " c E V f�rc`u3 E g ;g i Ix � v�