HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPAC�
Builder Name: WYNNE DEVELOPMENT
Street: ��- 0 R � ,
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL , 1
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: - St. Lucie (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
9. Wall Types(1432.0 sqft.)
Insulation * Area.
2. Single family or multiple family Single-family
a. Concrete Block - Int Insui, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4.. Number of Bedrooms 3
d• N/A
R= ft?
5. Is this a worst case? Yes
to. Ceiling Types. (1783.0 sgft.)
Insulation Area
_
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade.(fF) 1753
b. Knee. Wall (Vented) ,
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2 ,
11. Ducts
R 112
7. Windows(151.4 sgft.) .Description Area
a: Sup: Attic, Rat: Attic, AH: Attic
6 175
a. U-Factor Sgl, U=1.04 111.36 ft2
SHGC: SHGC=0.29
,
b. U-Factor: Sgl, U=101 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27 -
a. Central Unit
34.8 SEER:15.00
C. U-Factor: N/A ft2
SHGC:
18. Healing systems
kBlu/hr Efficiency
d. U-Factor: N/A 112
- a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1753.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1753:00 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.20
PASS
Total Baseline Loads: 53.92
I hereby certify that the plans and specifications covered by
Review of the plans and
� Zt1E57,
this calculation are in compliance with the Florida Energy
specifications covered by this
y a
Cade.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY'.
Before construction is completed
=; C
DATE: 1-9-211
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
G'OD,yVS
OWNER/P��ENT:
BUILDING OFFICIAL:
DATE: rid \\ ��
DATE:
-Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance witht$4p,�gjldeirid�hi iopr eaiirequlres an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2) C�IV CI1J it! f i
CODE COMPLIANCE
ST. LUCIE COUNTY
BOCC
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot#
Owner Name:
Total Stories: 1
Block/Sutidlvlsion:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 0
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No'
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
- New0ilsting: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.6 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire. House
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M. BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREATR
588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1 _
Yes
Yes
Yes
9 BATH
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 ft 0
224-ft-
_
0 1
0
28Iab-On-Grade Edge Insulatio
WIC 1 ft 0
63 ft'
_
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ft'
_
0 1
0
4SIab-On-Grade Edge Insulatio
M. BATH 7 ft 0
61 ft'
_
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft-
—
0 1
0
1/8/2020 4:43 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT. SUMMARY, CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value,
Tile Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 it
0
180 ft2
_
0 1
0
7SIab-On-Grade Edge Insulatio
DINING/GREAT 50 it
0
588 ft2
_
0. 1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN lift
0
209 ft2
_
0 1
0
9SIab-On-Grade Edge Insulatio
BATH 5 ft
0
50 ft2
_.Y
0 1
0
10Slab-On-Grade Edge Insulatio
HALL 1 It
0
25 112
0 1
0
11Slab-On-Grade Edge Insulatio
FOYER 9 it
0
92 ft2
_
0 1
0
129Iab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 It,
_
0 1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Metal 1847 ft2
0 ft2
Light
N
0.4
No 0.9
No 0
18.4
ATTIC
# Type
Ventilation Vent Ratio (1 in),
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63'112
0.1
Wood
_
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
_
4 Under Attic (Vented)
M. BATH
3b
' Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM.2
30
.Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DININGIGREAT
30
Blown.
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood'
9 Under Attic (Vented)
BATH
30
Blown
5o ft2
0.1
Wood
_
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 fN
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 112
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing' Framing Solar Below
Jz_v'Pe0
_ 1
E Exterior Concrete Block-
Int InS01ASTER BE 4.1 16
0 a
0
128.0 ft2
0
0 0.3
0
—2
W Exterior Concrete Block
-. Int Ins81ASTER BE 4.1 7
0 8
0
56.0 112
0
0 0.3
0
_ 3
S Exterior Concrete Block
-int InsOEASTER BE 4.1 14
0 8
0
112.0 ft2
0
0 0.3
0
1/8/2020 4:43 PM EnergyGauge®'USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
• FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing
Solar Below
0
-4
E
Exterior
Concrete Block - Int InsNASTER BA
4.1 - 8
0
8 0
64.0 ft'
0
0
0.3
0
8
E
Exterior
Concrete Block - Int Insul M. BATH
4.1 7
0
8 0
56.0 ft2
0
0 '
0.3
0
-6
E
Exterior
Concrete Block - Int InsBEDROOM 2
4.1 12
0
8 0
96.0 ft'
0
0
0.3
0
_ 7
S
Exterior
Concrete Block- Int InsGIINING/GRE
4.1 30
0
8 0
240.0 ft'
0
0
0.3
0
-8
W
Exterior
Concrete Block- Int InsiDINING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.3
0
_ 9
W
Exterior
Concrete Block- InllnsulKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
_ 10
E
Exterior
Concrete Block- Int Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
_ 11
N
Exterior
Concrete Block- Int Insul FOYER
4.1 8
0
S 0
64.0 ft2
0
0
0.3
0
_ 12
N
Exterior
Concrete Block- Int Insul FOYER
4.1 1
0
8 0
8.0 ft'
0
0
0.3
0
_ 13
W
Exterior
Concrete Block- Int InsBEDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0.3
0
_ 14
N
Exterior
Concrete Block - Int InsBEDROOM 3
4.1 1
0
8 0
8.0 ft'
0
0
0.3
0
15
N
Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.3
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening'
_
1
S 3
Metal Low-E Single Yes
1.04 0.29
N
32.4 ft2
1 it 0 in
1 ft 5 in
Drapes blinds
Exterior 5
2
E 5
Metal Low-E Single Yes
1.04 029
N
6.9 ft2
1 ft.0 in
1 ft 5 in
None
None
3
E 6
Metal Low-E Single Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
_
4
S 7
Metal Low-E Single Yes
1.04 0.29
N
39.8 ft'
1 It 0 in
1 It 5 in
None
None
5
W 8
Metal Low-E Single Yes
1.11 0.27
N
40.0 ft2
8 It 0 in
1 ft 5 in
None
None
6
W 13
Metal Low-E Single Yes
1.04 0.29 '
N
16.2 ft2
1 It 0 in
1 It 5 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 IF
26 It
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH50
1 Wholehouse Proposed ACH(50) .000254 1168.7 64.16
120.66
.0881
5
1/8/2020 47.43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Black
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5
34.8 kBtulhr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
AIr Flow
SHR Black
Ducts
1 Central Unit/
Split
Sing[ SEER: 15 34.8 kBtu1hr cfm
0.85 '1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal .120
deg
None
SOLAR HOT WATER SYSTEM
-
FSEC
Collector Storage
Cart# Company Name
System Model# Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
J — Supply —
-- Return—
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic
6 175 ft2
Attic
55 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
ProgramablfCoolingfe ThermostatJan:
CEeilAprlling Fans:
11Y
Venting Jan Feb
fFeb,fX11Mar
Mar
� 11
frX11 JulfrX11AugfrX11f[
May Jul
Aug
1]
Sep Sep
1] ffX11 Nov
f
Dec
ffX11
[ ] [ ]
[X)
[X]Apr [
] [ ]Jun [ ]
[ ]
[X]
X] Oct IX] Nov
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5. 6
7
8
9
10 11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80 80
80
PM
80
80 .78
78 78 78
78
78
78
78 78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78. 78
78
PM
78
78 78
78 78 78
78
78
78
78 78
78
Heating (IND) AM
66
66 66
66 66 68
68
68
68
68 68
68
PM
68
68 68
68 68 68
68
68
68
68 66
66
Healing (WEH) AM
66
66 66
66 66 68
68
68
68
68 68
88
PM
68
68 68
68 68 68
68
68
68
68 66
66 .
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 lbslsq.R.
0 ft2-
0 It
0.3
BEDROOM
Default(8 lbslsq.ft.
' ft2
ft
0.3
WIC
Default(816s/sq.ft.
ft2
It
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
It
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8lbs/sq.ft.
ft2
fl
0.3
BEDROOM 2
Defaull(8lbslsq.ft.
ft2
ft
0.3
ENTRY'
Default(8 lbslsq.ft.
ft2
ft
0.3
LAUNDRY
1/8/2020 4:43 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type Area Thickness Furniture Fraction Space,
Default 8lbsls .R. ft' ft . 0.3 GREAT/DINING
1/812020 4:43 PM EnergyGauge® USA 6.0.02(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, Stale, Zip: FT. PIERCE, FL, Permit Number:
Owner. Jurisdiction:
W
Design Location: FL, Fort Pierce
c=.>
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exteriortherrnal envelope contains a continuous air barrier.
not be used as a sealing material,
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned voth
The Insulatlon1n any dropped ceiling/soffit
the Insulation and anygaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be Insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per Inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be Insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing. cavity insulation shall be Installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and canblevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous Insulation Installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor Insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation,
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shallbeair tight and IC rated.'
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninina and wrina.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxesor air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers. shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
nkler cover nlates and walls or ceflinas.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Groundiwater source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
1753
d) Room unit(PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
151.4
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-fector:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c). Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
1oB2.
16. HVAC credits claimed (Performance. Method)
11. Ceiling type and insulation level a) Ceiling fans
a) Under attic 11a. 30.0 b) Cross ventilation No
b). Single assembly 11b. c) Whole house fan No
c) Knee walls/skylight walls 11d. 19.0 d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: �' Date: a" �A�
Address of New Home: \J� - \ \ JQ\\- City/FL Zip: FT. PIERCE. FL ��cl
1/8/2020 4:43:52 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1