HomeMy WebLinkAboutConstruction PlansGeneral Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, 93 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 300D PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. 8. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE L- ASTM C 150). AGGREGATES - N6 STONE, ASTM C 33 SIZE NO. 67 LESS THAN 3/4". AIR ENTRAINING +/- 1%- ASTM C 2% WATER REDUCING AGENT -ASTM C 494. CLEAN POTABLE WATER _ OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: LCONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. z.ALL MORTARS E OF TYPE M OR S. 3.ALL GROUTS L BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS Y-O" IN HEIGHT. C. ALUMINUM: 1. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-TS FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN" OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN' OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. THE FLORIDA BUILDING CODE 61h EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN 9I0 SMS 6" FROM THE ENDS AND IT ON CENTER, IF USING N 12 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. 1"X2"X0.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & 9IOX 1/2" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. D. FASTENERS: I. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD. 2. HEX BOLTS HAS TO BE AST ' , .` 25, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON,REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MR4IMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER FASTENERS SHALL BE A MINIMUM OF SAE GRADE N5 OR BETTER ZINC PLATED. S. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE 30D I9-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM A153. to. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 11. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 314" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. ASTM E 119 ASTM E 1300 CURRENT ASCE7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART I -A, & 1-13 ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLOEIDA BUILDING CODE 6th EDITION (CHAPTERS 16,20 & 23). F. ABBREVIATIONS: THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP-TYPICAL z. SIM - SIMILAR 3. UON- UNLESS OTHERWISE NOTED 4. CONT -CONTINUOUS S. VIF - VERIFY IN FIELD G. RESPONSIBILITY: 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOMROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. H. MISCELLANEOUS: I. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FLORIDA BUILDING CODE 6th EDITION R 4501.17 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST. SCREENING MATERIAL SHALL BE 18X14X0.0I3 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2. i. PLEASE NOTE: 2x2 (typ) DIAGONAL BRACING SHALL BE 2"X2"XO.055" MATERIAL, UNLESS OTHERWISE NOTED ON S-2. DESIGN DATA: 1. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED Vasd: 2. RISK CATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: SCREEN ROOF: 9 PSF SCREEN WALLS: 31 PSF SOLID ROOF(MWFRS): N/A COMPONENTS AND CLADDING LOAD: N/A 150 MPH 116 MPH 1 B 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18XI4X0.0I3 SCREEN MESH: 0.88 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 3001b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 2001b. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. _ 10 PSF VERTICAL DOWNLOAD ON SOLID ROOF. 8. 8"X8" W/ (1) k 5 REBAR W/ 25" OVERLAP ON 3" CHAIRS W/ 4" MONILITHIC SLAB W/ FIBERMESH FILLED W/ 3000 PSI SHALL BE ADEQUATE TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: HOPED GABLE 10. SOLID ROOF TYPE: N/A ALUMINUM STRUCTURAL MEMBERS HOLLOW SECTIONS 2 x 2:------------------------------------2" x 2" x 0.044„ 2 x 3:---------------------------------------2" x 3" x 0.050„ 2 x 4:-------------------------------------2„ x 4" x 0.050„ 2 x 5----------------------------------------2" x 5" x 0.050„ 3 x 3---------------------------------------3" x 3" x 0.125" OPEN BACK SECTIONS 1 x 2:--------------------------------------- I" x 2" x 0.040„ 1 x 3:--------------------------------------1" x 3" x 0.045. SNAP SECTIONS 2 x 2 SMS:----------------------------------2"x 2" x 0.045" 2 x 3 SMS---------------------------------2" x 3" x 0.072" 2 x 4 SMS:--------------------------------- 2„ x 4" x 0.045" 3 x 3 SMS:-------------------------------- 3" x 3" x 0.090" SELF MATING ISMS x MB----- 2" x 4" x 0.044" x 0.100" ----------------- 2 x 4 SMB:----- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:---------------------- Z" x 6" x 0.OSO" x 0.120" 2 x 7 SMB:---------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB:--------------------- 2" x 8" x 0.072" x 0.224" 2 x 9 SMB:---------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB:------ ------------ 2" x 10" x 0.092" x 0.374" TUBE SECTIONS 2 x 2----------------------------------------2" x 2" X 0.090„ REVIEWED FOR CODE COMPLIANCE ST. LUCAE COUNTY ROCC File COPY ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P, FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 ' Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 AbbottStation Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb @fbcplahs.com W ebsite-www.fbcplans.com C.O.A. #29054 DATE: 02/04/2020 DRAWN BY: BM REVISION: DATE: RO 1 RO 2 RO 3 RO 4 PROJECT ADDRESS: BONGIORN13 8836 FIRST TEE RD PORT ST LUCIE, FL 34986 ;ONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 NOTES S-1 2x2/DJ 1x2 � I F 2x5/DJ s-3 Cd X C1. cU X 1 4' CU cu 1x2 PROPOSED 8"X8" W/ (1) #5 REBAR LINEAL FOOTING W/ 4" MONOLITHIC SLAB \\ V) \ x X \�I N 2x2(t )N / O / I LX, S-3 / M 2+2---- ------ :0 I i N 5' — 0" 1x2 CU Z2x2(typl) / X CO / O (\ (U \ X \�VD P��(�X () V) X(U lD �D (U X X (U (LI O H S-4 c° 2x2(t ) 2X2(t I N 1x2 6'-3" (tYp) S 4 c-a 1X2 2x2/DJ j g2x2/DJ C 2x5SMB (U X_ cU 1x2 cu ,\4b :Z= ate. �o OF¢:CD ' o OFESS\ =% PROFESSIONAL ENGINEER SEAL ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.1 FLORIDA LICENSE: 38654 i�) Myron Max Neal P.E. FLORIDA LICENSE:86663 �N Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-www.fbcplans.com C.O.A. #29054 DATE: 02/04/2020 DRAWN BY: BM REVISION: DATE: RO 1 RO 2 RO 3 RO 4 )JECT ADDRESS: 3IORNO FIRST TEE RD F ST LUCIE, FL 34986 K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 FLOOR PLAN S-2 Y ALUMINUM GUSSET 2" x _PORLINS (SEE A-1 PLATE FOR SIZE)ATTACHED TO B #12 BEAM w/MIN (4) #10 x 1" SMS C� o m e e A \ N f ° • \ aye m m \ 'y�O q"e J �� a S3 y1'At'CPg�6i `SgB BEAM "B" "N" "S1" "S2" "S3" "S4" 2X4 12 4 3/4" i 16" 3.75" 2X5 12 4 3/4" 1 16" 4.75" 2X6 16 5 1" 1 Z" 19" 5.75" 2X7 20 6 1" 14" 22" 6.75" 2X8 24 7 1" 182" 23" 7.75" 2X9 24 7 1" 1-�" 23" 8.75" 2X10 28 8 i" 1 4" 24" 9.75" SMS NOTES: 1."N" NUMBER OF SCREWS IN ANY DIRECTION. 2. TOTAL NUMBER OF SCREWSPER JOINT EQUALS 4 TIMES "B". 3. PLATE WIDTH SHALL BE DETERMINED FROM ANGLE OF BEAM AND MIN. SPACE REQUIRED. 4. GUSSET PLATES MAY BE INTERNAL OR EXTERNAL. 5. INTERNAL SCREWS FOR PURLIN CONNECTION MAY BE INCLUDED IN TOTAL NUMBER OF SCREWS. 6. GABLE SPLICE WILL HAVE THE SAME �\ PATTERN. ( \ BEAM SPLICE GUSSET DETAIL TYPICAL S'3 SCALE: NTS HAVE (1) 3/8"0 THEO BOLT W/ NYLON LOCKING NUT OR THREAD LOCKING MATERIALAPPLIED )PTIONAL Z-BRACKET 0.250" 5" OR T'X 6" WIDTH X 0.250" EXTRUDED GUTTER BRACKET @ EA. BEAM W/ (4) 412 X 3/4 SMS INTO GUTTER LIP 1" x 2"x 0.045" OPEN BACK W/ (4)#14X 1-1/2" INTO GUTTER & (1)#14X 1-1/2" @ 24" O.C. ° BEAM ° Ili NOTE: 2X4 SMB BEAM ONLY REQUIRES 4" WIDTH GUTTER BRACKET W/ (2) 3/8" LAGS (4) 3/8" LAG SCREWS @ 1-1/2" SPACING PEA GUTTER BRACKET & @ 12" O.C. MAX- MIN EMBEDMENT SHALL BE 2" 2"x2"x%"XALUMINUM THE HOST STRUCTURE SHALL ANGLEw/ (4) #14 x3/4" HAVE AT LEAST 2"X4" SMS INTO BEAM ON EA SIDE SUPER GUTTER FASCIA AND ROOF TRUSS EA LEG (5" OR 7") SYSTEM. CONTRACTOR SHALL VERIFY THIS AND IF 2"X2"XO.062" RECEIVING (4) #12 x 3/4" SMS SMALLER- CONTRACTOR CHANNEL W/ (2) #10X 3 4" / INTO GUTTER EA SIDE SHALL BRING STRUCTURE UP EA SIDE TO COVER EXPOSED TO A 2"X4" FASCIA AND BEAM ENSURE LESS THAN A 2'-0" OVERHANG. �\ GUTTER BRACKET & BEAM ATTACHMENT DETAIL S' 3 N.T.S. •� 4. c�; oy . vl PURLIN ••• '�� Q.';V UPRIGHT WEB LAPPED OVER PURLIN P ,-` r W/ (2) #12X3/4" SMS EACH SIDE y�P Q• v ; ✓ ' 0 ' THRU UPRIGHT & PURLIN t+' •' ``Q BPl � •• T• \O\ ,a 2"X2"MEMBER ATTACHED TO F1'f� FES �,• UPRIGHT W/ (3) #10Xi-1/2" SMS PROFESSIO6fA17 ENGINEER SEAL INTO SCREW BOSS G 0 ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE:, 53608 1"X2"XO.045" OPEN BACK NDTCH POST Thomas L. Hanson RE _/ ATTACHED TO PURLIN W/ (2.) ASNEEDED #10Xi-1/2" SMS INTO SCREW FLORIDA LICENSE: 38654 Boss Myron Max Neal P.E. 1"X2"XO.045" OPEN BACK ATTACHED TO 2"X2" 0.045" UPRIGHT FLORIDA LICENSE: 86663 EAVERAIL MEMBER Joel Falardeau P.E. MS #lOXl9 Z4 50.0 7 FLORIDA LICENSE: 70667 "f Erik Stuart P.E. FLORIDA LICENSE: 77605 C SLOPED OR FLAT PURLIN UPRIGHT LAP DETAIL S'3 SCALE: N7S BEAM SCREWS 2"X4"SMB 6 2"XS"SMB 6 2"X6"SMB 8 2" X 7" SMB 8 2"X a' SMB 10 2"X9"SMB 10 2"X 10" SMB 12 HINGE LOCATION CZ) #IOX3" SMS CROSS FOR SLOPED BEAMS; SCREWING BRACE TO BEAM OR 2" x 2" EXTRUSION MAINTAIN ALL SCREW SPACING HAVE MEMBER (.125" BACKING 2" x 2" EXTRUSION FROM EDGE OF BEAM PLATE USED) HINGE LOCATION DOOR 2" x 2" EAVE RAIL SECTION (UNLESS OTHERWISE SHOWN ON S-2) ROOF -ATTACHED TO BEAM W/' / (3)1UX 2" SMS INTO SCREW BRACE BOSS / 1"X2"OPEN BACK HAVE RAIL ATTACHED TO OPRIGHTw/(2) HINGE LOCATION #10 x 1 K" SMS INTO SCREW 2"x"Z"x.125" FLAT BOSS A / BAR (typ)j__ #10 X 1 j2" SMS 24" C/C NOTES: 1. HINGES SHALL BE ATTACHED TO STRUCTURE W/ (3) #10 x 5/8" SMS MINIMUM. 2. DOOR SHALL BE ATTACHED TO ENCLOSURE w/(2) HINGES MINIMUM. 3. HINGES SHALL BE ATTACHED TO DOOR WITH (3)#10 x S/8" SMS. FASTEN A 1" x 2" x 0.044" TO UPRIGHT W/#12 x 1" SMS @ 12" O.C. AND WITHIN 3" FROM �\ END OF THE UPRIGHT. ( j ROOF BRACING CONNECTION DETAIL S'3 SCALE:N.TS. (TYPICAL SCREEN DOOR CONNECTION DETAIL SCALE: NTS #14X 3/4" SCREWS (SEE TABLE ABOVE) i i i i'ELF-MATING BE, rSHALL BE NOTCL of FOR UPRIGHT i i 001I 9 oil NOTCH OF INSIDE BEAM I SLIDE OVER UPRIGHT (MIN) UPRIGHT D UPRIGHT TO BEAMCONNECTION-ALL WIND ZONES S-3 SCALE: NTS FBC Plans & Engineeril Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com W ebsite-www.fbcplans.com C.O.A. #29054 DATE: 02/04/2020 DRAWN BY: BM REVISION: DATE: RO 1 RO 2 RO 3 RO 4 PROJECT ADDRESS: 8836 FIRST TEE RD PORT ST LUCIE, FL 34986 K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S-3 OPTIONAL r5" OR 7"-X 0.250' EXTRUDED GUTTER Z-BRACKET 0.250" BRACKET 2" GUTTER BRACKET REQUIRED AT PURLIN ATTACHMENT POINTS w/ (2) #12 X 3/4" SMS INTO GUTTER LIP 1" x 2" x 0.045" OPEN BACK W/ (2)#14X 1-1/2" @ ANGLE & (1)#12X 2-1/2" @ 24" O.C. OR OPTIONAL 2"X2"XO.045" PURLIN (1) 3/8" LAG SCREWS @ EA. GUTTER BRACKET & (1) @ 12" O.C. MAX- MIN EMBEDMENT SHALL BE 2" I THE HOST STRUCTURE SHALL 2" x 2"x Y," X ALUMINUM HAVE AT LEAST A 2"X4" ANGLEw/ (4) #12 x3/4" FASCIA AND ROOF TRUSS SMS INTO PURLIN ON EA SYSTEM. CONTRACTOR SHALL SIDE VERIFY THIS AND IF & (4)12X1-1/2" INTO SMALLER- CONTRACTOR GUTTER SHALL BRING STRUCTURE UP TO A 2"X4" FASCIA AND ENSURE LESS THAN A 2'-0" OVERHANG. Al GUTTER BRACKET & PURLIN ATTACHMENT DETAIL S 4 N.TS. OPTION #1 (4)#10x1X"SMS INTO OPTION#2 SCREW BOSSES-7 . 2"XZ" OR 2"X3" 0.062" ALUMINUM INTERNAL OR MEMBER I EXTERNAL W/(4) 10X3 CEIVING CHANNEL /4"INT0 INTO BEAM OR UPRIGHT. (2) #14X 3/4" EA. LEG INTO GIRT OR PURLIN - (0.062' ANGLE CLIPS / (2) 14x3/4" SMS EA LEG) UPRIGHT OR BEAM -SNAP OR SELF MATING OR HOLLOW I H PURLIN OR GIRT TO BEAM OR POST DETAIL S'4 SCALE:NTS (4) #10 X 3/4" SMS FASTENING SECONDARY ANGLE TO COLUMN (TY EACH SIDE) (B)- CONCRETE SCREW ANCHOR INTO SECONDARY ANGLE('FYP EACH SIDE) (SEE O c TABLE) 0 O ANCHORSPA (MIN) (TYP)(SEE TABU) Column Size 1/4"& 3/8" 0 Concrete Screw Anchor B Min. Spa 2x3-1/4" 0 0" 2x4-1/4" 1 3" 2x5-1/4" 1 3" 2x6-3/8" 1 4" 2x7-3/8" 1 5" 2x8-3/8" 2 3 2x9-3/8" 2 4" 2x1 U-3/8" 2 4.5" SECONDARY ANGLE MIN 0.125" THICK (NOT REQUIRED FOR 2X3 PRIMARY 2" X 2" X 0.125 ANGLE [2) #10 X 3/4" SMS FASTENING COLUMN TO PRIMARY ANGLE (TYP EACH SIDE) 1" X 2" BASE MEMBER (T'_ EACH SIDE) (1)- CONCRETE SCREW (SEE "6 TABLE) ANCHOR INTO PRIMARY ANGLE AND @ 1/4" 0 CONCRETE 3"(MIN) SCREWANCHOR@ 24" O.C. BETWEEN COLUMNS NOTES: MP EACH SIDE) I. NUMBER OF ANCHORS"B" IS EACH SIDE INTO THE SECONDARY ANGLE AND DOES NOT INCLUDE THE ANCHOR INTO THE 1X2. 2. MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4" AT AT ALL UPRIGHT LOCATIONS. ALL SCREW LENGTHS AT UPRIGHT CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. 3. CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON THOSE LISTED ON S-1, D.FASTENERS, OTHER BRAND& TYPE SHALL BE APPROVED BY ENGINEER \' 4. 2X3W/1XZ CORNER POST SHALL REQUIRE SAME BASE �1 CONNECTIONS AS ZX4 SHOWN IN TABLE. 1" PER FT. MAX FOR 2'-O" NOTE: WHEN USING OPTION 5" MIN BEFORE STEEPER CONNECTION CABLE MUST BEE MIN. SLOPE OPTION #1-A-36 STEEL WITHIN 6" OF CORNER OR o o a GRADE CLIP MAY BY PLACED ON PRIMARY MEMBER. 1/8" ALUMINUM DOUBLE COMPRESSION S. TOP OR SIDE OF DECK W/ 1" X 2" X 1/8" ANGLE PLATE @ 45' SLEEVES (2) 3/8"X 3" SLEEVE ANGLE W/ 1" TOP OF ANUOR CONCRETE (4) #12 X 3/4" SMS BREAK @ 90° W/ y 4" NOMINAL SLAB ® ® (TYP TOP AND SIDE) 5/16"EYE BOLT TYPE 1 MINIMUM ® ® FLAT SLOPE NO FTG ZF m d WASHER EA SIDE <2:12 0 Z d 1/8" DIA. STAINLESS (9) 414 X 3/4 SMS OPTION #1 a• "' a G ' STEEL CABLE @1" O.C. a e GRADE 3/8" 0 x 3" MASONRY 2500 PSI CONCRETE W/ 3/8" WELDED STAINLESS m ANCHOR ANCHOR (MIN 3-3/4" OPTION #1 WELDED WIRE OR STEEL EYE BOLT OPTION #3 'a. EMBEDMENT) 4" SLAB ONLY) ( FIBERMESH (8) #14 X 3/4 SMS W • ReeaR coenrvuous w/zE^ IOVERLAPATALLIOINTS ON 3- Side View ~8,CHAIRS&CENTERED (1) #5 CONT ON 3" 0.125" STAINLESS 1" 0 (MII� WASHER / _ 8" CHAIRS STEEL CABLE 2500 PSI CONCRETE W/ BENEATH NUT B"x8" TYPE II MONOLITHIC SLAB vo in TOPOF WELDED WIRE OR LINEALRIBBON MODERATE SLOPE FTG CONCRETE FIBERMESH ® ® a a FOOTING SLOPE: 2":12"-3":12" C o a OPTION #2 OPTION #3 4" NOMINAL SLAB d ' Top View 3/8" OADJUSTABLE EYE NOTES FOR ALL FOUNDATION TYPES: MINIMUM A o d O ®I e BOLT FOR CABLE TENSION I. THE FOUNDATIONS SHOWN ARE BASED ON A MINIMUM SOIL BEARING PRESSURE OF 1,500 o OPTION#2 a 1/8"0$TAINLESS PSF. THE BEARING CAPACITY OF THE SOIL VERIFIED BYALICENSED CONTRACTOR PRIOR TO I STEEL CABLE ANY POURING OF CONCRETE. 2. THE SLAB/FOUNDATION MUST BE CLEARED OF ALL DEBRIS, AND COMPACTED PRIOR TO 1-1/2"X5-1/2"ALUMINUM OPTION#2 POURING OF ANY CONCRETE. X 3"(USE ST�MASONRY WITH FOOTING) 3. CONCRETE MEET THE SPECIFICATIONS IN THE S-1 NOTES PAGE. ANCHOR PERIMETER FRAMING (MIN 3-3/4' BEDMENT) 2"X2'X 1/8" EXTRUDED ANGLE K CONTINUOUS LINEAL FOOTING/ OR FOOTING W/SLAB O 1 J CABLE TO FOUNDATION CONNECTION DETAIL Side View ON 45"ANGLE S-4 TTss� OPTION #1 S_4 SCALE:NTS JZ CABLE CONNECTION AT CORNER S'4 SCALE:NTS „11111i13f I'`/ w�UpRT °O GJ �! LI o • Z u py� ES ''•�� V 01 PROFES91ONALI ENGINEER SEAL ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE:53608 Thomas L. Hanson P. FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 /Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.tb cplans.com C.O.A. #29054 DATE: 02/04/2020 DRAWN BY: BM REVISION: DATE: RO 1 RO 2 RO 3 RO 4 PROJECT ADDRESS: BONGIORNO 8836 FIRST TEE RD PORT ST LUCIE, FL 34986 CONTRACTOR: K & S INDUSTRIES, INC. 1379 SW BILTMORE ST. PORT ST LUCIE, FL 34983 DETAILS S4