HomeMy WebLinkAboutManualsBOARD OF COUNTY COMMISSIONERS GAS PIPING SCHEMATIC [A4] TANK SIZE PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation FEB 14 2020 ST. Lucie County, Permitting ST. LUCIE COUNTY BUILDING DIVISION [Al] [A3] [A REVIEWED FOR CC M C6 REVIEWED BY DATE TANK SIZE: � GALS. PLANS A P RMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE APPLICANCE - TYPE/SIZE /, Z vp L . Al �IeflPl FZ BTU A2 BTU A3 BTU© A4 BTU A5 BTU A6 BTU PIPING LENGTH 8r SIZE L1 5b FT. 3 "INCH DIA. L2 FT. INCH DIA. L3 FT. INCH DIA. L4 FT. INCH DIA. 1-5 FT. INCH DIA. L6 FT. INCH DIA. L7 FT. INCH DIA. L8 FT. INCH DIA. 1-9 FT. INCH DIA. L10 FT. INCH DIA. 1-11 FT. INCH DIA. L12 FT. INCH DIA. Revised 7/22/14 (PIPE SIZE WAS TAKEN FROM THE 2014 FBCFUEL GAS CODE - TABLE 402 L_--)) Websile: www.stlucieco.aov 2300 Virginia Avenue - Fort Pierce, FL 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578 •.r , •'r 's 1 (1) 1 C J • ON, ■ ■1 o e♦ Designed to reduce first stage pressure of 5 to 20 PSIG down to bumer pressure, normally 11' w.c. Ideal for medium commercial installations, mulfiple cylinder installations and normal domestic loads. • Large vent helps prevent blockage and has i° F.NPT for vent piping. • With 15 PSIG inlet pressure, regulator Is designed to not pass more than 2 PSIG with the seat disc removed. Incorporates integral relief valves. • Replaceable valve orifice and valve seat disc. • Straight line valve closure reduces wear on seat disc. Unique bonnet vent profile minimizes vent freeze over when property installed. Large molded diaphragm is extra sensitive to pressure changes. Built in pressure tap has plugged 1r6" F.NPT outlet Plug can be removed with a 3/16" hex alien wrench. ' Batlu�wunr design • Mmdmum 0mv pried w 10 PSIG inlet and a-w.c delivery PM. . Body _............. _........ ......... ........ .............. 0............. Die Cast Zinc Bonnett_.............................................................. Die Cast Zinc Nozzle Office ...... ................. ......................_............_._._._.... Brass Spring ...... _.... ....... .............. .............. _............_..............:. Steel _.... Valve Seat Disc ..... __..............................._......0..... Resilient Rubber Diaphragm .._.._................... integrated Fabric and Synthetic Rubber. LISTED LV44038Seafes A qG 100 RnO Oc P.O. Rox 247 Fran. NC 2n" Ua1 x .Mgopmduels.com PMne (336) "9-TrO7 Fax (336) 4n9-6594 M—Effel Application Materials Ideal for use as a first stage regulator on any domestic s¢e ASME or DOT container in propane gas installations requiring up to 1,500,000 BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. Features • Compact design can be connected to a service valve using either a POL adapter or a Rego product pigtal. • Large threaded Ye RNPT bonnet vent can easily be pIPed-away underground installations without the need of glue Idfs or extra adapters. • Non Adjustable • Large How orifice resists freeze ups due to water concentration in LPG vapor. • Design provides for good How regulation at both high and law container pressures. • Built in relief valve and travel stop comply with NFPA 58 over pressure requirements. • Incorporates %• F.NPT downstream pressure tap for an easy inline check of the regulators delivery pressure. • Molded diaphragm provides an o-ring type seal between the body and bonnet • Body and bonnet are assembled in the USA using the unique, patented RegUlok seal system. Fully painted in brilliant red for complete oortosion protection. Mounting bracket available as an accessory: part number 2302-31. Body._.................._.—....._.._......_...............----- ........ 7MG sonnet .... ..... .... ................ _......_._ _._.............__..._. _ . Steel spring ._..__........._.._................................ arj Rubber Seat Disc ..... ........ .....-.-._._.._ .............. ....._......_Rest etic Rubber Diaphragm ............... -.... Integrated Fabric and Syn u pO Ordering information FLOW PNOPME LV34031RVr ..._ - ui andd, 'Y pre 1MU%lower Nan a"setfirig. ry ,d, nMw b.M an lN.tpm. 20 PSIG hyber Nan lba regutabO' 9a delivery pressure TO%lower Nan the re9 tnstiOn9 A1" 100 Rego Or. P.O. a. 247 Sort NC 2r246115A wwwregopmducts.mm POtte (Si6)149-710T Pax (338I 0d9-654r 07—S - . ,ML Chaplet 15 • pipe and Tubing5bing Tables TABLE 111(0) Polpethvkm PIusfrc P Regmlamrs. Nominal Outside Diameter Cas: Und9drdFwjOe NiktPrasure:. MOO prersweDrap: LOpsl ari�tc Gravity: 1.52 Plarttc ... — — 1'/ n. YA.in 2 in Pipe h in r I I11d gpR 10.00 ll " SDR 1100 SDR 1L00 Lcngt6 SDR 9.33 SDR ILO SDR (ISSN (1943) �) (0.660) (6.860) (7.071I 20260 36402 30 2143 4292 77'4 1.%16 11A81 17340 . 31155 1835 1626 673 fifi 1 10176 15368 13924 27612 25019 60 1473 2 50� 5322 921-0 8483 12810 ?3017 70 - 1355 2714 4896 7691 11918 21413 80 1361 2525 4555 4274 1q4 11M 20091 90 1183 2369 4037 10562 18978 100 1117 2118 3578 -199 9361 16820 L5 990 1983 1797 3242 .5616 SA82 15240 150 997 2983 7803 14020 175 826 1653 neo9 77'9 6811 1a043 — 12238 225 721 1443 2603 4510 6434 11560 250 681 1363 1244 ?336 4D46 6111 10979 275 646 7 3860 5330 10474 300 617 5 ]23_ 1136 2050 3551 5363 8965 300. 567 528 1057 1907 3JOA 4981 4681 8411 400 450 A50 495 992 1789 1690 3100 2928 4422 7945 495 917 1531 2653 4007 7199 600 424 849 781 1409 2441 6623 6623 6161 700 390 363 726 1311 2271 3�29 3217 5791 800 682 1230 1933 2131 5461 1000 644 1616 2-441 4385 1500 258 517 798 1383 2089 3153 ?DDU 271. 4-0 IpS; Jan pipe size. SDI-* Shand= dinhension tzrio. Notes: (11 Capecitirs , in I000 Btu/hc inside diameter. �1 DIIIIensices in paze ad es ure 2014 LP -Gas Code Hmibook auwnlsrm Quality Steel Corporation AG/UG Propane Tanks —L LED .D1 1450 r'q. %46 DP PPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS WATER CAPACITY DIAMETER (OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT . LEG* WIDTH LEG' SPACING WEIGHT (lbs.) **QUANTITY FULL LOAD. PERSTACK * 120 wg. 24" Ellip, 5 -8 3 141/2' 2'-101%2" or 3'•]1" 260 108 (96 16 12 *250 wg. 30" Hem!. 7'-10" 3'-8" 1'-5" 4'-IT' 480 54 9 *320w9. 30" Hemi. 9'-7" 3'-8" 1'-5" 5'1 620 45 9 640 wg 1000w9. 71/2" 41" Hemi. Hemi. 10' 16' 4'-2" 4'-5" 1'-8" 1'-8" 5'1 10�1" 950 1,800 1 37 130' 1 17 115 81 6 61 5 14SO wg. 461/2" Ellip. 17'-4" 4'-11" 1'4" 11'-711 2,650 12 4 1990 wg. 461/2" Ellip. 23'-11" 4'-11" 1'-9" 16' 3,520 8 4 Dimensions and specifications shown are approbmate. Individual vessels may vary. •Legspacing+/-2". Leg widths and spacing mayvary based on mfg.location. check with your salespuson for details. 120,250,320 wg. standard tanks -no holes In legs (one center hole on request(. 500 and 3000 wg. standard tanks - 2 holes 16" on ceder. 1450 wg. and up as shown above. •• Full load and stack quantities vary by shipping location. Check with your salesperson for details. General Specifications Conforms to the latest edition of ASME Rules for Construction of PressureVessels, Section VIII, Division 1. Complies with NFPA 58. - Rated at 250 psig from -20" F to 125" F. All vessels registered with National Board. - Two serviceoptions available: Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane topcoat, supplied with steel AG/UG dome. All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Updated June 30, 2015 1LV. CABLE W/ CLAMPS TO (PULLED ANCHOR STRAP (2) LAYERS OF FELT BETWEEN STRAP AND CLAMPS (PULLED 0 UNDERGROUND TANK HOLD DOWN DETAIL GENERAL NOTES: 1. HEUCAL ANCHORS SHALL HAVE AN ALLOWABLE PULL—OUT CAPACITY AS SHOWN DELANCHORS SHALL BE INSTALLED PER ANCHOR MAflllF�rg jbRER.TO ACHIEVE STATED LOAD CAPACf1Y. CAPACITY VARIES WITH SOIL IL TYPE VERIFY ANCHOR CAPACITY WITH SOIL 7q`P;EbTCOO FlTEftEf): po 350 ` eGCHECK��OR 11NDI`RGROUN.D UTILITIES PRIOR TO ANCHOR INSTALLATION -19 . LOCATION TANK RELATIVE;r„TD ADJACENT STRUCTURES AND FEATURES ARE DEPENDENT UPON LOCAL CODES AND IS THE =RE,sPONSI6ILITY OF OTHERS. :THE., .AS $HQWN HAS. BEEN DESIGNED TO PREVENT FLOTATION, COLLAPSE, OR LATERAL MOVEMENT DURING THE BASE .BLOOD..,% EVENT" ..... .. _ t\J O COP0GHF 2016 — FARLEY ENGINEERING, LLC PA 'DAT� AMERIGAS r 4w Consulting Engineer #40111 — CA28108